| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹6.9 L+₹881 (0.13%)Rejected-Finance | L2 | Rejected-Finance bidder is not L1 | |
| 3 | L3₹6.9 L+₹1,196 (0.17%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹13,879
Closing Date
5 Nov 2024, 2:00 pmClosed
Executive Engineer-I,PWDte.
Office of the EE-I,CKHED,PWDte P12 CIT Road 1st floor Kol 14
Replacement of Concealed type Air conditioning Machines at Blood Centre and Burn Unit of Surgical Block under the campus of Calcutta National Medical Collage and Hospital Kolkata
2024_WBPWD_737929_1
WBPWD/EE/CKHED/eNIT-27/ 24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Calcutta National Medical Collage and Hospital Kol
As per NIT
4 documents required · 4 mandatory
₹13,879
Office of the EE-I,CKHED,PWDte
9 Apr 2025
22 Aug 2024
11 Nov 2024
22 Aug 2024
5 Nov 2024
29 Aug 2024
27 Aug 2024
Amount
Supply & Delivery of 7.5-TR capacity concealed type Split Air Conditioner of following specification : rated cooling capacity : 90,000 BTU/Hr. compressor : 3 Nos Rotary type. refrigerant : R- 410A, IDU : 3no. of 230V,50Hz,1-Ph. ODU : 1no. of ,415V,50Hz,3-Ph. Air-flow/per IDU:-1000CFM. Casing size of IDU : (1130mm x280mm x532mm)(WxHxD) approx, Casing size of ODU : (1350mm x600mm x840mm)(WxHxD) approx, (Make : Hitachi/O-General/Voltas/Daikin). [At Blood Centre]
Supply & Delivery of 5-TR capacity concealed type Split Air Conditioner of following specification : rated cooling capacity : 60,000 BTU/Hr. compressor : 2 Nos Rotary type. refrigerant : R- 410A, IDU : 2no. of 230V,50Hz,1-Ph. ODU : 1no. of ,415V,50Hz,3-Ph. Air-flow/per IDU:-1000CFM. Casing size of IDU : (1130mm x280mm x532mm)(WxHxD) approx, Casing size of ODU : (1150mm x500mm x795mm)(WxHxD) approx, (Make : Hitachi/O-General/Voltas/Daikin). [Attached Store With Blood Centre & Burn Unit]
Lifting,Shifting,Installation,Testing & Commissioning of IDU & ODU of following capacities concealed type Split Air Conditioners machines,after making hole in ceiling /wall on mending good the damages to the original finish as required & necy. scaffolding arrangement,labour cost etc.on both side(IDU & ODU Installation), and also connecting rod/rope from the ceiling must be attached into the machine by nuts,bolts etc. as per recurement with incl. Supply of required Refrigerant R-410A ,S&F of necy. fixing arrangement for indoor & Outdoor duly painted etc. as per direction of EIC if required. i). 7.5Tr.
Supplying fabrication & fixing of 2nos U-Channel (TATA Make) of size (75 mm x 50 mm x 50mm x 6mm thick) for making platform for instalation of outdoor unit of 5/7.5 TR Concealed type split AC incl. drilling 2nos holes in each channel as per site condition & as per direction of EIC. incl. cutting holes into the wall & grouting the same with cement concrete (1:1 %1/2: 3) etc incl. mending as orginal and fabricated with horizontal angle of 25 mm x 25 mm x 6mm including supporting angle 50 mm x50mm x 6mm in each platform in outer edge for transmitting the load centrally through 2Nos (50 mm x50 mm x 6 mm) Angle inserted to the exiting wall The entire structure should be baricated & safe for ODU maintenance Area of the platform is 2Mx1.2M. incl. scaffolding arrangement,labour cost etc.(Structural design should be approved from EIC.)
Supply and fixing of AI powder coated continuous Grill (Make- Premier, Dynacraft/ EIC approved.)
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets etc. (Make- Ryoku/Totaline/Jobu/ Nippon) a) Suction Line (5/8 OD with 0.7mm thick)
b) Liquid Line (3/8" OD with 0.6 mm thick)
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Supreme/Accoflex/Armacell/EIC Approved) a) Suction Line (5/8 OD with 0.7mm thick)
Liquid Line (3/8" OD with 0.6 mm thick)
Supply and laying Control copper Cable (PVC insulated & unshethed,un-armoured) from Condensing Unit to IDU control panel (Make: Havells/RR Kable /finolex ) 4 core 2.5 sq mm communication cable.
Supply and laying of Drain Water piping work out of PVC/HDPE hard pipes of following sizes incl. fiting accessories bends, elbows, tees flanges, tapings, wall sleeves hangers, supports, anchors etc. as required.(Make : Supreme / Astral). a) 25 mm dia.
Modification of window grill for accessing outdoor unit of Concealed Air conditioning Machines by cutting the grill and making Necessary arrangement by welding , grinding inch. S/F Hinge and Lock & key , as per direction of EIC.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/ RR) in 25/30mm size PVC Rigid Conduit 'FR' (Precision make-HMS/MMS) incl. necy. fittings as required. 4 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC. [E14:1b(v)]
Finishing of the PVC insulated wire ends by socketing with pin/ ring type copper sockets and insulated tapes etc.,including supplying sockets, tapes. i)6sq mm. [F5:9(iii)]
ii)4sq mm. [F5:9(ii)]
Supply and fixing 4-way MCB SS enclosure with IK-08 protection, powder coated & S&F of 63A,4pole Isolator in DIN channel, concea-led in wall after cutting the wall & mending good the damages to the original finish or total establishment on flat iron frame in wall incl. inter-connection with suitable size of copper wire, necy. painting,& provision for earthing attachment etc. as required. [Legrand 507793] D-9/11 & D-5/6
Supply & Fixing Moisture proof,water-proof (outdoor type IP-65) PVC ( Sintex make, GSJB-3425)looping cable box size 300x250 x150 mm deep having 2/3 mm thick body enclodure comprising of one no.415 V,63Amp FP Isolator on din channel ('C'-curve,legrand make ), with 4way copper terminal and having lined with rubber gasketed top cover should be fixed on wall by screws,nuts, washers etc, necy. socketting, rubber gasketted entry and exit as mending the good damages as original with proper finishing at terminal is required.
Supplying & fixing of 415V, Timer DB Fixed on Wall by flat iron/Angle frame or as per direction of EIC . The Box should comprising following accessories......... A).Double-door SPN-MCB Distribution Board with IP-42/43 protection 2+10 way make Legrand/Eqv. EIC Approved. B). 1No. 250V ,50Hz,16 Amp Digital daily & weekly time switches(Make L&T-67DDT0/Eqv. legrand) C)1No 415V,40A FP-Contractor(Make-L&T/Eqv. legrand). D)1No. 415V,40A FP-MCB(Make-L&T/Eqv. legrand). E)1 No. Toggle Switch(Pass & Seymour) should be fixed inside the box. F)1Nos LED Indication Lamp for running condition. G)The complete arrangement must be wiring by suitable size of PVC insulated Cu wire with suitable socket/lugs as per requirement & direction by EIC .
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
SUPARNA REFRIZARATION (BID ID -5732821)
SKY DECORATIONS PRIVATE LIMITED (BID ID -5738825)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .