Superintending Engineer Electricity Distribution Circle-Unnao
SCHEDULE OF RATES AND QUANTUM OF WORKS INVOLVED FOR (INCREASING CAPACITY OF DISTRIBUTION TRANSFORMER, REPLACEMENT OLD JARJAR BATTREY CHARGER SET) UNDER THE SPECIAL BUSINESS PLAN YEAR 2023-24 IN THE AREA OF E.D.S.D.-II, HASANGANJ UNDER E.D.D.
2023_MVVNL_854670_1
165/E.D.C./Unnao/2023-24
Open Tender
Electrical Works
Fixed-rate
180 days
Unnao
AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
A/C-No.3355002101008374,IFSC-Code-PUNB0335500
₹18,000
Yes
4 Nov 2023
21 Oct 2023
28 Oct 2023
21 Oct 2023
27 Oct 2023
21 Oct 2023
Amount
Carriage of following materials from Elec. Store Center Unnao to work dump site along with loading unloading and propoer stocking.
PCC Pole 8.5 mtr long
ACSR Weasel Conductor
ABC conductor (3x50+1x35+1x16)
L.T. Cable 1x400 sq mm
11 KV XLPE cable of size 3x185 sq mm
33 KV XLPE cable of size 3x300 sq mm
11 KV jointing Kit of size 3x185 sq mm
33 KV jointing Kit of size 3x300 sq mm
Other loose line materials with including conductor, Single and double Pole accessories, complete stay & earthing, insulator, x-arm, etc.
Carriage of following materials from Elec. Store Center Unnao to work dump site along with loading unloading and propoer stocking.
Battery Set
Charger Set
Carriage of following Transformer from Elec. Store Center Unnao to diff. work dump site along with loading unloading and propoer stocking.
T/F 25 KVA 11/0.4 KV
T/F 63 KVA 11/0.4 KV
T/F 250 KVA 11/0.4 KV
T/F 400 KVA 11/0.4 KV
Dismantling of following Transformer from Plinth / Double Pole with Safe Carriage from work site to dump site along with loading unloading and propoer stocking.
T/F 10 KVA 11/0.4 KV
T/F 16 KVA 11/0.4 KV
T/F 25 KVA 11/0.4 KV
T/F 100 KVA 11/0.4 KV
T/F 250 KVA 11/0.4 KV
Mounting of following Transformer on double pole including its cartage and dragging from dump site to pit site.
T/F 25 KVA 11/0.4 KV
T/F 63 KVA 11/0.4 KV
Placement of 11/0.4 KV T/F from dump site to newly constructed T/Fs Plinth & installation and commissioning of 250/400 KVA T/Fs of T/F Plinth and including jumpering with the system. (All the required materials as Al. Lugs Crimping Type for 250/400 KVA T/F Copper L-piece 62x225x12 mm etc for above job shall be provided by contractor except T/Fs and LT PVC Cable)
Construction of T/F Plinth of size 2x2x1.5 m on a padding 0.25 M deeo in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr height & 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick, brick work in ration 1:4 cement & cores sand in the hollow portion the sand should be filled from the ground level up to 15 centimeter below from the top of wall, cement, sand & brick ballasts should be filled up to 15 centimeter. Two nos. of channel 100x50 in length 1500 mm will be grouded, 0.35 CM. RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4. The T/Fs plinth should be plastered on all sides 12 mm thick in ratio 1:6 by cement and cores sand. (All the material will be arranged by the contractor)
Earthing of Neutral of Transformer, Transformer body and double pole by way of boring and lowering of ‘B’ class G.I. Pipe 1.5” dia from ground up to the water level (Minimum 20 Mtr. Deep) with a solid cone at the lower end of G.I. pipe. Connecting and bringing out contineous G.I. Strip size 32X6 mm. from the cone to the ground surface where it will be connected with G.I. pipe clamp from which Transformer neutral, Body & D.P. connection being done by G.I. Strip.(All the materials will be arrangement by the contractor)
Erection of PCC pole (for making double pole) including digging of pits, fitting of all accessories along with cartage & dragging from dump site to pit site.
Grouting of PCC Pole as per RESPO Norms with grouting materials.
Earthing of pole as per RESPO Norms.
Digging of pits, fixing nuzzling and grouting of stay rods as per RESPO Norms with grouting materials.
Laying stringing and sagging of following type HT/LT Lines including all associated work with joint/jumpers and binding of insulator as required.
11 KV Line Three Phase
L.T. Line by ABC Three Phase
Fixing of 3-Phase Distribution Box with clamp, N&B (Only D.B. Box Provided By Department)
Laying of 11 KV XLPE cable underground including cost of laying material as per RESPO Norms.
Laying of 33 KV XLPE cable underground including cost of laying material as per RESPO Norms.
Making and fixing of 11 KV jointing kit
Making and fixing of 33 KV jointing kit
Safe Carriage of following T/F from work dump site to Electricity store center Unnao with loading, unloading and proper stocking.
Recevied back old T/F 10 KVA 11/0.4 KV
Recevied back old T/F 16 KVA 11/0.4 KV
Recevied back old T/F 25 KVA 11/0.4 KV
Recevied back old T/F 100 KVA 11/0.4 KV
Recevied back old T/F 250 KVA 11/0.4 KV
Installation of Battery & Charger Set
Dismantling of old Batter Set
Dismantling of old Charger Set
Installation of new Battery Set with complete all work as required
Installation of new Charger Set with complete all work as required
Carriage of Old Battery & Charger Set from dump site to ESC Unnao with loading, unloading and proper stacking.
Received Back Old and Jarjar Batter Set
Received Back Old and Jarjar Charger Set
M/S EVERGREEN TRADERS
M/S RATHORE ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .