Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.3 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹6.5 L+₹19,200 (3.06%)Rejected-Finance | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹6.6 L+₹32,100 (5.12%)Rejected-Finance 3 NEW TRIMURTY CO OP HOUSING SOCIETY INGOLE NAGAR WARDHA ROAD NAGPUR 440005 MAHARASTRA | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹7.7 L+₹1.4 L (22.0%)Rejected-Finance B 248 BASEMENT BLOCK B CHITTARANJAN PARK NEW DELHI 110019 11 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | 4 | Rejected-Finance Not Lowest | |
| 5 | 5₹8.3 L+₹2.1 L (32.8%)Rejected-Finance | 5 | Rejected-Finance Not Lowest |
Tender Value
₹8.4 L
EMD Value
₹16,900
Closing Date
27 Apr 2022, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
PROVN OF DETAILED STRUCTURAL AUDIT AND NDT TESTING OF OHR NO. 01, 08, 12, 16, 18 and 19 AT DIFFERENT LOC UNDER GE (U) BATHINDA AT BATHINDA MIL STATION
2022_MES_514117_1
CWE BTD 8198/E8
Open Tender
Civil Works
Item Rate
90 days
Bathinda
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (U) Bathinda
₹16,900
Yes
13 May 2022
17 Mar 2022
29 Apr 2022
17 Mar 2022
27 Apr 2022
24 Mar 2022
17 Mar 2022 - 24 Mar 2022
Amount
M&L for detailed structural audit and Non destructive type testing to be carried out by any of IIT/NIT or any Specialist agency approved by E-in-C Branch for over head reservoirs No. 01, 08, 12, 16, 18 & 19 at different locations as specified in following steps and testing procedures:-
Rebound hammer test : Conducting rebound hammer test as per IS 13311 (Part-2), ASTM C 805. The rebound hammer test shall be conducted at all those points where UPV test has been performed.
Cut and Pull out (CAPO) Test - as per ASTM C 900.
Ferro scanning: To measure the cover of the structural member.
Physical condition Assessment: This shall include physical condition of OHSR such as painting , accessibility for cleaning, conditions of stairs, manhole cover, ventilation, all pipes with sizes , material of pipes, valves with sizes, whether pipes and valves are functional etc. Reason for non usage of the OHRs should also be evaluated and documented. (Format should be developed and shall be submitted to GE for approval prior to the survey)
Reporting: Preparing and submitting comprehensive report consisting of test data, interpretation of results, conclusions and recommendations for remedial measures, methodology of repairs, rehabilitation and retrofitting of structures, the draft costed schedule, target enhanced life of building/structure and including the details from S No. 1.01 to 1.07 . The recommendations for structural repairs and rehabilitation to the structures to make it fit for use shall have detailed technical specifications and materials to be used complete all as specified and as directed.
Note:- (i) Cost for providing transportation to Bathinda and back and visit of OHRs during testing procedure and Boarding & lodging to testing team is deemed to be included in quoted rates. (ii) Cost of surface preparation for testing at OHR and providing of machinery like Hydra, Crane etc is deemed to be included in quoted rates
KBP CIVIL ENGINEERING SERVISES
M/S. BECQUEREL INDUSTRIES PVT. LTD.
Cortex Construction Solutions Pvt. Ltd.
S P BAGWE CONSULTANTS PRIVATE LIMITED
Epicons Consultants Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .