Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC | ₹2.5 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.7 Cr+₹24.3 L (9.76%)Rejected-Finance H NO 02 SAGAR ROAD OPPO MKD GIRLS SCHOOL TILAK NAGAR BIKANER 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | ₹2.7 Cr+₹24.3 L (9.76%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹2.9 Cr+₹42.2 L (17.0%)Rejected-Finance | ₹2.9 Cr+₹42.2 L (17.0%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹3.4 Cr+₹94.7 L (38.1%)Rejected-Finance | ₹3.4 Cr+₹94.7 L (38.1%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹4.1 Cr+₹1.6 Cr (66.0%)Rejected-Finance WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹4.1 Cr+₹1.6 Cr (66.0%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹3.0 Cr
EMD Value
₹3.8 L
Closing Date
27 Apr 2021, 6:00 pmClosed
CE (AF) WAC PALAM DELHI CANTT
CE (AF) WAC PALAM DELHI CANTT
IMPROVEMENT TO WSA AND ARMOURY AT AF STN NAL
2020_MES_403490_3
CEWAC/NAL/T-02/2020-21
Open Tender
Civil Works
Lump-sum
450 days
GE (AF) NAL
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (AF) NAL
₹3.8 L
Yes
3 Jun 2021
31 Mar 2021
29 Apr 2021
31 Mar 2021
27 Apr 2021
15 Apr 2021
31 Mar 2021 - 8 Apr 2021
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Construction of Armoury building with permanent specifications complete all as specefied as shown on drawings.
NOTE: Schedule ‘A’ Part II to IX under are Prepriced by MES.
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “PCC FIRE BREAK PLINTH" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for “ADDN/ALTRN P-70, PARKING SHED, SHED FOR EXISITING & NEW EOT CRANES" as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-VI
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “LIGHTENING PROTECTION" as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “DEMOLITION & DISMENTLING WORK” as listed in Schedule ‘A’ Part IX
SCHEDULE `A' PART - X MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
INTERNAL ELECTRIFICATION
Supply & fixing Flame proof zone I & II, Gas group II A/ II B Arial flow fan 450 mm sweep (exhaust fans) complete with flame proof motor AC single phase 230/ 240 V of suitable watt including all fixing arrangement in wall by cutting suitable hole in any type of double wall 600 mm deep and providing " Z" shape Gl ducting of size 450x450 x1500 mm including wire mesh at inside and damper at out side with handle for operation complete all as directed by Engr - in - charge.
Supply & fixing Flame proof zone I & II, Gas group II A/ II B ceiling fan 1200 mm sweep complete with flame proof motor AC single phase 230/ 240 V of suitable watt including all fixing arrangement all as required complete all as directed by Engr - in - charge.
Supply & fixing LED 1x20 watt FLAME PROOF zone I & II, Gas group II A / ll B tube light fixture luminaire including integral reflector made of diecastalluminium alloy LM6 , with electronic ballast, bipin holders, .connector block, etc., and all accessories pre-wired and including connecting up with suitable size copper conductor twin core cable complete.Make : Crompton / Bajaj / Sudhir (WSA-18 & DILU Bldg-16) complete all as directed by Engr - in - charge.
S&F in repair Flame proof zone I & II, Gas group II A/ II B LED BULK HEAD light fitting FLP-WP of 40 built in control gear box made of aluminium alloy LM6 , with all accessories, ballast, lamp holders, etc. internally prewired including taking down old fittings complete. Make: Sudir, model BH/124 or equivalent from Crompton / Bajaj ( WSA-24 and DILU- 06) complete all as directed by Engr - in - charge.
S&F Ceiling fan, Copper wound, 5 star rated complete with suitable length of down rod (appx 600 mm) from RCC slope roof , canopy, mounting clamp etc. AC, 230V, 1200 mm Sweep without regulator including 0.50 Sqmm 3 core flexible Copper cable from fan connector to ceiling fan all as directed. Note. Rate quoted shall deemed to be included for suitable length of down rod from roof to false ceiling complete all as directed by Engr - in - charge.
S&F Submain wiring with three single core(for phase and neutral +earth) 4 sq mm wire using multistranded copper conductor PVC (FRLS) insulated unsheathed PVC insulated wire drawn through concealed stove enamelled steel conduit ISI Marked and all accessories of dia not less than 20 mm with and including steel conduit and accessories complete all as specified and directed. . . (Note: Three runs of 4 sqmm wire and one run of steel concealed conduit shall be measured as one run only
S&F Submain wiring with five single core(for three phase and neutral +earth) 6 sq mm wire using multistranded copper conductor PVC (FRLS) insulated .unsheathed PVC insulated wire drawn through concealed stove enamelled steel conduit ISI Marked and all accessories of dia not less than 25 mm with and including steel conduit and accessories complete for 12 way DB complete all as specified and directed. (Note: Five runs of 6 sqmm wire and one run of steel concealed conduit shall be measured as one run only
M&L Flame proof Gas Group IIA/Group-IIB, weather proof point wiring for one light/ fan point controlled by one switch using approved colour coding as per IS with zerohologen flame retardant (HFFR) smoke free nontoxic non corrosive with copper cable 1.5 Sqmm (normal area) single core insulated and unsheathed stranded cable 1100vol!s grade and including (ERW) stove enameled concealed conduit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC unsheathed copper conductor 1.5 Sqmm nominal area as earth wire as earth continuity conductor complete all as specified and directed by Engr-in- Charge. . (a) One light point /fan point controlled by one switch (for existing-44 & DILU Bldg-28)
Ditto but for 3 pin 15 Amps socket outlet independent with cable 2.5 sqmm complete all as specified and directed.
Supply and fix Flame proof - weather proof CMRI approved MCB socket & plug combined 16 A, 500 V(3P+Earth) for EOT crane including taking down old socket & plug complete all as specified and directed.
Supply & fix Flame proof zone I & II, Gas group II A/ II B Sheet metal enclsoure SPN 8 way for fixing MCBs 240 volt including MCB DP 40 A10 KA.230 volt -1 No as incomer & MCBs SP 6 to 32 Amps,10 KA.230 volt 6 Nos as outgoing with as specified . (WSA-04 & DILU-01)
Supply & Fix Switch flame proof ‘rotary type, with termination box in LM6, 16A, single pole 250V Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
Supply & Fix flame proof zone I & II, Gas group II A/ II B Switch socket and plug combined 16 amps 250V 2 pin and earth plug fully interlocked siutable for installation in hazardous zone as per IS 2147/62 all as required and specified.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with the top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts check nuts and washer of galvanised iron or steel incl protection pipe 15mm dia light grade and water ing pipe 20mm bore medium grade, necessary excavation, earth work in any type of soil, 1:3:6 typed PCC chamber, Cl chamber cover, watering pipe, funnel etc all as shown in electrical plate No 5 of SSR part I connected to earthing test point all as indicated including testing on completion
SUMMER APPLIANCES
Supply and install inverter type hi wall split units indoor and outdoor complete with cordless Each remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2 TR complete with all fixing arrangement on wall /floor including refrirerant line from outdoor unit to indoor unit as required at site with out any extra cost. Make :Daikan/ Ogeneral / Hitachi.
Supply and install inverter type hi wall split units indoor/outdoor complete with cordless Each remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2. of capacity of 1.5 TR, BEE 5 star rated complete with all fixing arrangement on wall /floor including refrirerant line from outdoor unit to indoor unit as required at site without any extra cost. Make :Daikan/ O-general / Hitachi Note for Item Ser No 4.01 & 4.02 : (a) Quoted rates include copper suction & discharge line, electric cable from indoor unit to outdoor unit minimum 3 Mtr or above all as per site requirement. (b) Rates include suitable stand for fixing Outdoor unit on wall/ on floor. (c) Rates include initial charging of Refrigent Gas, include testing and commissioning complete and submitted two set of temp test sheets.
Supply and fix refrigerator, electric driven (single phase), capacity 195 Litres BEE 5 star Each rated floor mounted with all fixed accessories as per OEM and PVC stand complete all as specified and directed include initial charge of Refregent Gas complete include testing & commissioning make Samsung model RR2015SSB or equivalent make in LG/Whirlpool/Godrej.
Supply and Install Water cooler MS/stainless steel duly painted, Steel tank, electric driven Each single phase having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour BEE 5 star rating include making Inlet water connection and drain out water connection complete all as specified and directed. Make : Voltas/Blue Star/ Sriram (USHA) Note :Gl pipe line for water in let connection to be measured & paid seperately under relevant item of schedule.
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity minimum 4000 CuM per hour (or nearest size) (Gl sheet body) on equal angle iron frame structure complete with Gl tank capacity 60 Itr approx, including MS angle iron stand made of 50x50x6 mm fixed on wall near window include two coat of synthetic enamel black paint over a coat of red oxide on angle iron frame complete. Note :Gl pipe line for water in let connection shall be measured & paid separately under relevant item of schedule.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA include making connection from power point to Indoor unit complete all as directed. Make : V Guard/Microtek / Volina
All as per item No. 4.06 above but of capacity 4.0 KVA
Supply & Fixing, testing and commissioning of control panel for auto / manual operation of humidifier/ dehumidifier system incl all electronic controls & components, sensors etc to measure parameters such as temperature and humidity of Air conditioning system capacity up to 75 TR and to operate the humidifier / de-humidifier at desired level all as per guide lines given in STEC Pamphlet - 7 to control required humidity inside the conditioned space including all control wiring through PVC conduit from equipment to humidifier / de-humidifier . wiring also extended up to to sprinkler pump, hot water, three way control valves etc. The control unit shall also have provision of manual mode as well as Auto mode for smooth functioning of system complete all as specified and directed.
Note: (i) Rate is inclusive for taking down unserviceable wiring and control panel and shifting to store under sch of credit, (ii) Control valve if any required shall be measured and paid separately. NOTE:- GA drawings for control panel shall be submitted by contractor before commencement of work.
M&L for modification of dehumidification system by dismantling, Taking out cooling coil of existing AHU's capacity 8500 CFM of make EDGETECH and provision of copper tubes rows parallel to existing evoporator and as required to maintain RH 60 +5 % by using hot water system. The hot water copper tubes shall be inserted through authorized agency of original manufacturer of AHU including carryout all connected works such as inserting, soldering copper tube assembly of suitable size , through the AHU's manufacture / authorized dealeras to maintain RH within 60 +1-5 % and Dehumidification of excessive cooling in air condition in grooms, subsequent reheating of air, rearrangement of existing hot water line by cutting, welding and insulating the existing line complete. Modification of hot water line existing required at site shall also be carried out by the contractor under this job without any additional cost.
Note: (i) Control valves required at site shall be measured and paid separaly.(ii) Contractor shall visit site before quoting the item (iii) Design of modifications required will be submitted by the contractor for approval of GE before commencent of modification work at site. (iv) Rate quoted shall also deemwd to be included for testing and commissioning.
All as per item No 4.10 above but for AHU capacity 19000 CFM make ZECO
Supply and fixing Butterfly valve suitable for 80 mm bore pipe, PN 1.6 complete all as specified and directed.
Supply and fixing Butterfly valve suitable for 65 mm bore pipe, PN 1.6, complete all as specified and directed.
S&F Humidifier system, water spray type of capacity suitable for AHU capacity 8500 CFM Make EDGETECH having pump & nozzle combination consisting of Water spray. nozzles of suitable size, submersible pump set, balancing tank, piping, control valve etc floor mounted type made from stainless steel 304L, in welded construction. Inlet, Drain and outlet base & pipe including controls having Low level switch for low level cut out with Nylon ball, float valve with SS ball, site glass, with inlet & outlet pipe line with valves & NRV include tank complete all as specified including taking down old unserviceable humidifier pan type & directed.
All as per item No 4.15 above but capacity suitable for 19000 CFM
Note for Item No 4.15 & 4.16: Contractor shall submit design, make and model of humidifier system to GE for approval before commencement of work. (ii) Rate quoted shall also deemwd to be included for testing and commissioning.
Taking out old unservicable fire damper from the supply air duct by dismantling exisiting duct carefully kept and shifting to store under sch of credit.
Supply and fixing of automatic fire dampers actuated by a low melting alloy /fusible type rating as per UL-555-1995 in main supply air duct & return air duct including control wiring. The dampers shall be made of heavy gauge galvanized steel having multi blade construction. The blades shall be fitted with chrome plated shaft and self lubricated phosphorus bronze bushes. The dampers shall also be provided with jam seal (compression type) on sides to prevent spread of smoke and fire. The blades of the dampers are held in the 'open' position by a high tensile spring and a fusible link. The fusible link should be UL stamped and operates at 60-70'C, causing the damper to close immediately on break fire to prevent the spread of fire through the ducts all as specified and as directed by Engineer-in-charge.
LIGHTENING PROTECTION
M&L for chemical earthing with copper earth plate of size 900x600x5 mm & copper earth strip 32 x 6 mm buried in ground vertically to a depth not less than 3.0 metre below ground level with top edge earth electrode at a depth not less than 2.10 metre deep below ground level including suitable quantity of backfill chemical compound for filling in each pit to cover earth electrode minimum 150 mm all around and electrode shall be jointed with the copper strip of size 32 x 6 mm by exhothermic weld complete with earth pit chamber of size 300 x300 mm and RCC cover for demarking the location of earth electrode location. Make of Back Fill Compound: Tercel (Isogel) (Australia)/ Indelec (Xgel) (France)/ ERICO (GEM) (USA)/ LPF (Reslo) (Australia) (for cat Abldg)
(Note (i) The quantity of Backfill compound and depth of earth pit shall be increased by the contractor without any extra cost to Govt, to ensure earth resistance value within less than 1 ohms on completion and testing. The testing of each earthing shall be carried out in presence of Engr-in-charge and test results shall be submitted duly signed by user concered while claiming payments.) (ii) Earth strip with protection pipe 50mm Gl light grade upto 7.5 meter is deemed to be included in the rates quoted.
Taking down old unserviceable termination rod 20 mm dia complete all as specified and directed.
Taking down old Copper / Alluminium strip of any sizes as down conductor/roof conductor carefully for re-use, shifting unserviceable conductor to store under sch of credit all as directed.
Refixing Copper / Alluminium strip of any sizes as down conductor/roof conductor after soldering between earth strip and refixing the copper / aluminium strip by providing new porciline insulator or burried in ground or drawn in conduit including PVC conduit, fixing apprangements with wall/roof all as per clause SSR part I and as directed.
ADDN/ALTRN BLDG NO. P-70
Supply and fixing for aluminum anodised grills, DG-104 of Deco Grill/Hindal 10 mm thick, diamond shape with aperture 75mm fixed to windows complete all as specified and directed.
Material and labour for applying evenly a coat of bitumen primer @ 0.36 Ltr/Sqm complete all as specified and directed.
Demolition of existing water proofing treatment any type from top surface of roof slab and emove the old material obtained to low lying area as directed by Engg-in Charge to any distace complete all as specified and directed.
Material and labour for preparation of old surfaces of wood/steel exceeding 10 cm girth and applying two coats of Fire resistant paint for complete all as specified and directed.
Material and labour for preparation of new surfaces of wood/or wood based material exceeding 10 cm girth and applying two coats of Fire resistant paint over a coat of primer, complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Supply, installing, testing and commissioning of Indoor type step down transformer, 11KV/433 volts AC three phase 50 Hz, 400 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, oil natural- Air natural (ONAN) , with external cooling tubes/fins, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondary side (LV side) and having tapings on HV side tb vary secondary voltage between ±7.5% be changed by means of • hand operated off load tap changer gear. The maximum temperature risse should not exceed 45 degree celcius in oil and 55 degree celcius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius.
The transformer shall be IS-1180 ,2014 marked and shall comprise of following: (a) Cable box on HV side with three nos porcelain bushing suitable for 11 KV, complete with brass/copper rods, nuts and washer (b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out out of LT 1100 volts grade XLPE, armoured cables including jointing materials complete, (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fill of dehydrating agent (silica gel) (e) Explosive vent, the mometer pocket on tank cover, oil levjbel gauge, oil drain filter valve, lifting lugs/jacks, oil filling hole with cap/plug with connection plate complete, Air release valve plug and-four nos plain solid cast steel detachable rollers
(f) One no dial type thermometer, vapour pressure type, having range 0-120 degree celcius with metal guard having maximum perimeter temperature reading indicator with re-setting device, (g) Two earthing terminals on tank cover to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing of body, (h) Rating plate and terminal marking plate (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral including all other standard accessories. Note: (i) First filling of new transformer oil conf to IS-335 marked (Make- Savita/Power link) filtered and tested upto 40KV dielectric strength at 2.5 mm air gap between electrodes.(ii) rate also inclusive for providing tools & plants required for testing and commissioning of transformer by SEI. NOTE: Rate quoted shall also deemed to be included for making suitable foundation for transformer.
Dismantling .Taking down existing transformer from its original position Each after disconnecting Ht, LT connection carefully and shifting transformer to Job MES store all as directed
Supply, install, testing and commissioning LT panel board outdoor type, factory made with CRCA Sheet of thickness 3.15 mm,angle iron frame of size 5’0x5Ox6mm compartmentalized, platform mounted -to accomodate the following items and built upon PCC Foundation , duly powder coated with gray paint and suitable size of cable glands chromium, plated complete with the following:- (i) Aluminum bus bars 4 Nos, 300 Amps, 433 Volt (ii) MCCB conf to IS/IEC 60947-2,thermal magnetic 200 Amp,4P, 36 kA - 01 (Incoming) (ii) MCCB 4 Pole conf to IS/IEC 60947-2, 100 Amp 25 kA- 02 No (Outgoing) (ii) MCCB 4 Pole 32 Amp 25 kA- 01 No (Outgoing) (iii) Automatic street light Astro Timer switch for automatic switching ON / OFF for street lights.The Timer switch shall be complete with and including power connector, MCB and support terminals, wiring, bus bar suitable for Three phase controlled through power contractor rating 40 Amps, HRC fuse,
M&L for Earthing complete with copper plate electrode 600mmx600mmx 3.15 mm thick buried directly in ground vertically in pit of depth not -less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not tess than 1.5 metre beiow normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to copper earth strip of size 20 x 3mm thick as earthing lead by means of Gl bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment all as shown in electrical plate No. 5 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore
light grade Gl pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
M&L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less-than 2.25 metre below normal ground level with top-edge of the earth prate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm dia as earthing lead by means of Gl bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade Gl pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1
light grade Gl pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Taking down old UNSV light fittings any type and Supply & Fix LED street light 72 Watt operating temp range -20deg.C to +50 deg C SL light fitting 72 Watt fitting ingress protection IP 66 conforming to IS 16107 with photo biological saftey as per IS 16108, type of LED luminarie as per IS and type B , Type of LED modules as per IS 16103 type 3 with luminarie system efficiencey 100lm/watt with adjust mounting brackets. Make Surya Cat part No SLE UL 72W IP66 LXN or equivalent in WIPRO/Crompton Greaves/Bajaj.
M&L for wiring from street light fitting to junction box with two single core 1.5 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through 20 mm dia. Rigid metallic steel conduit fixed on pole with suitable clamps including 1.5 sqmm copper conductor PVC insulated earth continuity wire, accesories and connecting to junction box complete al as specified and directed.
Supply and fix LED 105 W flood light fitting on pole /wall with lense, high luminous rectangular LED flood light with innovative. thermal management and available with multiple optics and equipped with IP 66 protection belter distribution applicable for area lighting including" suitable mounting brackets nuts and bolts and electrical connection complete all as directed. Make :- Surya Cat ref No SLE FL 105W IP65 R FLOOD or equivalent WIPRO/Crompton Greaves/Bajaj
Taking out LT cable XLPE/PVC sheathed 1100 volts grade armored with aluminum conductor carefully of any size up to 50 sqmm from trenches, poles, under floor etc for further use/disposal all as specified and directed. (for Street light poles )
Relaying of serviceable LT cable of size 10/16 Sqmm 4 core intrenches/ Gl Pipe including relaying bricks retrieved under item 11 above. (Note: (i) Earth work will be measured and paid separately under relevant items).
Material and labour for making cross hole suitable for 50 mm dia bore pipe including passing Gl pipe of size 50 mm dia, below the road with the help of pressure pipe/ boring tools for passing the cable and removing of surplus soil to a distance not exceeding 100 mtr from work site all as directed. Note :Gi pipe to be measured and paid separately under relevant items,.
S&F in replacement for kiosk box of minimum size 300x200x100 mm for luminaries control switches, weather proof made out of PVC/HDPE fire retardant, non-fusing, shock&rust proof, single piece moulded/SMC housing and SMC cover with .hinged door, pole mounting type comprising of aluminium busbar TPN of 60 Amps with 6 Amps MCB, SP with base channel , fixed on pole with MS, clamps 30x5 mm with necessary nuts, washer for Street light)
M&L for cable route indicator 15cm dia made out of cast aluminium duly marked with size and type of cable fixed on ISA 40x40x6mm angle iron support embedded including in PCC 1:2:4 type B1 (300x300x400mm) and steel surface painted with two coats of anti-corrosive paint over a coat of red oxide primer including necessary earth work all as specified and directed.
Dismantling, taking out existing HT cable of 3x95 sqmm / LT cable 3.5 c x240 sq mm from transformer/ LT panel and shifting to store under sch of credit
HOT CRANE
Design, manufacture, supply, errection, commissioning Hand operated overhead Travelling (HOT) crane of capacity 3.0 MT single Girder type consisting with chain pully block with geared travelling trolley, two nos long travel I beam, main girder, wheels chain required for cross &longitude movement, end carriage and all accessories suitable for 3 MT capacity HOT crane with the following technical specification and painting complete all as per IS-807 of 2006, IS-3832:- (location: ESH - 5 & ESH - 6 outside application). . . Note: (I) Rate quoted shall deemed to be included for Arranging required load for Testing of crane as per BIS - 14470 of 1997.(11) Contractor shall submit GA drg and design plan of HOT crane and connected items with calculation details for approval by AO before procurement.(iii) contractor shall take actual dimension from site before submitting GA drg. Bldg plan is enclosed for reference
Type- Single Girder HOT Crane Capacity- 3Ton Cross travel Span- 4 meters (approx) Long travel- 7 meters (approx) Lift- 05 Meters(approx) Class- Class - II IS duty – IS 807/3177 location - Outdoor Main host- 3 MT Chain pulley block with chain Speed- Manually operated Brake-Manually with chain and gears chain- Forged with slings Cross travel Speed -Manually gears Wheel - Dia 130-4 nos. . . Long Travel-Manually operated,Speed- Manually operated Brake-Manually, Wheel-Dia 160-4 nos. Long travel rail-40 x 40 M.S. Bright, Long travel Rail and Gantry-suitable for 7 meters LT at both side (approx) Operation- From floor with chain and sprocket No of Falls- 2/4 Falls
Hook- Single shank Forged Swiveling type with safetv latch All Gears-Forged and hardened All wheels-EN -9 , Forged , with 300 BHN Hardness Painting-One coat of rust converter & Two coats of Golden Enamel yellow Girder Type-Beam type Buffers-Provided on CT & LT Bearings-SKF Hook-Karan forging Steel plates-TATA steel /SAIL Oil seals-Rubber equipment manufacturer design
Supply only synthetic rubber mat of size 2mx1mx10mm
Supply only synthetic rubber mat of size 2mx1mx19mm
SHREE GURU NANAK CONSTRUCTION COMPANY
M/s Khanna Enterprises
R.K. CONSTRUCTIONS & EARTH MOVERS
M/S Shiv Shakti Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .