The DIGP,GC,CRPF,Bhubaneswar
The DIGP,GC,CRPF,Bhubaneswar
Limited Tender for Repair/re-winding of coil of ceiling /exhaust fan, Geyser and Window/Split Air Condition (1.5 Ton -2 Ton) for existing installation at various places in office, residential and non-residential buildings at GC CRPF BBSR, Odisha
2023_CRPF_732651_1
B.V-1/2022-23-GC BBSR Bldg
Limited
Electrical Works
Item Rate
90 days
The DIGP, GC, CRPF, Bhubaneswar
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹9,630
Yes
25 Jan 2023
4 Jan 2023
12 Jan 2023
4 Jan 2023
11 Jan 2023
4 Jan 2023
Amount
Rewinding of ceiling fan/Exhaust fan of following sweep after dismentalling the worn out coil i/c heat vernishing, tapping ,testing and commissing etc. as reqd.i.e Ceiling fan of 1200 mm sweep
Rewinding of ceiling fan/Exhaust fan of following sweep after dismentalling the worn out coil i/c heat vernishing, tapping ,testing and commissing etc. as reqd. i.e Exhaust fan of 300/400 mm sweep
Disassembling the Geyser from existing position, dismentling part by part for cleaning, greasing and Re- assembling in complete shape i/c. testing, commisioning complete as required after repairing/replacement of the following parts by new one in old existing Gyser as reqd.i.e Coil
Disassembling the Geyser from existing position, dismentling part by part for cleaning, greasing and Re- assembling in complete shape i/c. testing, commisioning complete as required after repairing/replacement of the following parts by new one in old existing Gyser as reqd.i.e Thermostat
Disassembling the Geyser from existing position, dismentling part by part for cleaning, greasing and Re- assembling in complete shape i/c. testing, commisioning complete as required after repairing/replacement of the following parts by new one in old existing Gyser as reqd.i.e Indicator
Disassembling the Geyser from existing position, dismentling part by part for cleaning, greasing and Re- assembling in complete shape i/c. testing, commisioning complete as required after repairing/replacement of the following parts by new one in old existing Gyser as reqd.i.e Power cord (Type, 3 Pin. Power, 220V AC 50HZ. Current, 16 Amp)
Disassembling the Geyser from existing position, dismentling part by part for cleaning, greasing and Re- assembling in complete shape i/c. testing, commisioning complete as required after repairing/replacement of the following parts by new one in old existing Gyser as reqd.i.e. Connection Pipe (Suitable for Hot & Cold)
Chemical Cleaning / Servicing of 1.5 TR / 2.0 TR Split A.C i/c dismantling the front and side cover of indoor and outdoor unit, air blower cleaning the finns of cooling coil and condenser Coil with cleaning agent like blue guard and fresh water checking all electrical connection, PCB's & greasing / oiling indoor and outdoor fan motor, reassembling the same complete testing etc. as required.
Dismantling and repairing of the following AC units including replacement of defective parts such as starting / Running capacitors, Repairs and replacements Codensor ,Compressor etc. as required.1.5/2.0 TR capacitor Split Type AC unit
Dismantling and repairing of the following AC units including replacement of defective parts such as starting / Running capacitors, Repairs and replacements Codensor ,Compressor etc. as required 1.5/2.0 TR Condenser Split Type AC unit.
Dismantling and repairing of the following AC units including replacement of defective parts such as starting / Running capacitors, Repairs and replacements Codensor ,Compressor etc. as required 1.5/2.0 TR compressor Split Type AC unit
Supply and laying of 20mm PVC drain piping including binding/clamping etc as required
Providing and fixing of mother board of 1.5/2.0 TR Split A.C/PCBs as per model in complete shape i/c. testing commissioning complete as required
Providing and topping up of refrigerant R-32/410A Gas for 1.5/2.0 TR capacit Split Type AC unit in complete shape i/c. testing commissioning complete as required.
Providing and full filling of refrigerant R-32/410A Gas for 1.5/2.0 TR capacit Split Type AC unit in complete shape i/c. testing commissioning complete as required
MAA TARA ENTERPRISE
M/S HASIBUL & CO.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .