Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 44 1 3 VILL RITHANI DELHI ROAD WEST RITHANI MEERUT UTTAR PRADESH 250103 | MEERUT | UTTAR PRADESH | 250103 | Accepted-Technical Qualified |
| 2 | Accepted-Technical | Accepted-Technical Qualified |
| 3 | Accepted-Technical | Accepted-Technical Qualified |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹8.6 L
Closing Date
3 Mar 2026, 2:00 pmClosed
Executive Engineer STD I JPDCL Jammu
Office of the Executive Engineer STD-I, JPDCL, Jammu
Construction of 33/11 KV, 1x6.3 MVA Receiving Station alongwith allied works for e-Buses Charging Port at Bhagwati Nagar in respect of Sub Transmission-I, JPDCL, Jammu
2026_PDD_302807_1
e NIT 28 of 2025
Open Tender
Electrical Works
Turn-key
90 days
Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Executive Engineer, STD-I, JPDCL,Jammu
₹8.6 L
Office of the Executive Engineer STD I JPDCL Jammu
30 Apr 2026
10 Feb 2026
4 Mar 2026
10 Feb 2026
3 Mar 2026
10 Feb 2026
10 Feb 2026 - 14 Feb 2026
13 Feb 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Sub Transmission Division-I, JPDCL, Jammu
Name of Work:- Construction of 33/11 KV, 1x6.3 MVA Receiving Station alongwith allied works for e-Buses Charging Port at Bhagwati Nagar in respect of Sub Transmission-I, JPDCL, Jammu
Contract No: e-NIT No: STD-I/JPDCL/Tenders/2025-26/28/6642-45 dated:10-02-2026.
Sl. No. Item Description * Bidders are requested to quote the rates for all items which must be inclusive of Supply, Erection, Testing and commissioning of all items including Taxes, Labour charges, Overhead Charges etc. ** Before quoting the rates bidders are requested to visit the site *** Material should be in accordance to latest IS and IEC Standards Dismantalled material will be write back to Divisional store on no cost Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Part-A-Supply & Erection of Equipments for 33kv line bay & transformer bay SUB‐STATION MAIN EQUIPMENT 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) 2 No. Excess(+) Full Conversion INR
2 33kV C&R Panel along with O/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port-SCADA Compatible (For Line Bay) 16 No. Signal 8 DI and 8 DO 2 No Excess(+) Full Conversion INR
3 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port -SCADA Compatible (For Transformer Bay) 2 No. Excess(+) Full Conversion INR
4 33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 Poles, 25 kA) 2 set Excess(+) Full Conversion INR
5 33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 Poles, 25 KA) 2 set Excess(+) Full Conversion INR
6 33 kV Current Transformer (Ratio 600/300/5 Amps, Outdoor) (1 No. per Φ) 2 Set Excess(+) Full Conversion INR
7 33 kV Voltage Transformer (33 kV/Ö3/110 V, Outdoor), (1No. per Φ) 2 Set Excess(+) Full Conversion INR
8 Lightening Arrestors 33 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) Gap Less 2 Set Excess(+) Full Conversion INR
9 11kV, Gapless Surge Arrestor,9 kV, 10 kA, LA with Polymer housing, Stn. Type (8/10 Sets) 2 Set Excess(+) Full Conversion INR
10 33 kV Polymer Post Insulator 36kV, 235 kV Impulse, creepage distance 1224m 6 Nos. Excess(+) Full Conversion INR
11 Pipe Structures i) Nominal Bore 200, 5.9 mm thick 1.77 MT Excess(+) Full Conversion INR
12 ii) Galvanized Steel Structures 4 MT Excess(+) Full Conversion INR
13 iii) Galvanized Nuts & Bolts of Sorts 0.5 MT Excess(+) Full Conversion INR
14 CONTROL CABLES i) 12 Core 2.5 mm² Control cable copper Armored , 1.1 kV Grade, ISI, FRLS 400 M Excess(+) Full Conversion INR
15 ii) 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS 400 M Excess(+) Full Conversion INR
16 iii) 4 Core 2.5 mm² Control cable copper Armored , 1.1 kV Grade, ISI, FRLS 400 M Excess(+) Full Conversion INR
17 iv) 2 Core 2.5 mm² Control cable copper Armored , 1.1 kV Grade, ISI, FRLS 400 M Excess(+) Full Conversion INR
18 iv) Lugs, Ferrules etc. 3 Item Excess(+) Full Conversion INR
19 11 kV XPLE Power Cables‐ i) 11 kV 630 mm² Single Core XLPE Power Cable (with one spare length) armoured, FRLS 500 Mtr Excess(+) Full Conversion INR
20 ii) 11 kV 3-Core XLPE 185 mm² armoured power cable 800 Mtr Excess(+) Full Conversion INR
21 120 mm² PVC LT Cable 4 Core, armored, FRLS 100 Mtr Excess(+) Full Conversion INR
22 11 kV Heat Shrinkable Cable Termination Kit for incoming Cable i) 11 kV Indoor Heat Shrinkable Cable Termination Kits 630 mm 8 Set Excess(+) Full Conversion INR
23 ii) 11 kV Outdoor Heat Shrinkable Cable Termination Kits 630mm 8 Set Excess(+) Full Conversion INR
24 11 kV Heat Shrinkable Cable Termination Kit for Outgoing Cable i) 11 kV Indoor Heat Shrinkable Cable Termination Kits 185 mm2 7 Set Excess(+) Full Conversion INR
25 ii) 11 kV Outdoor Heat Shrinkable Cable Termination Kits 185 mm2 7 Set Excess(+) Full Conversion INR
26 CONDUCTOR & HARDWARE i) 200 mm² ACSR Conductor Panther 300 M Excess(+) Full Conversion INR
27 ii) T Clamps for 200 mm² ACSR Conductor Panther 30 Nos. Excess(+) Full Conversion INR
28 iii) Single Tension Fittings for 200 mm² ACSR Conductor Panther 18 Nos. Excess(+) Full Conversion INR
29 iv) Polymeric composite Disc Insulator 33 KV 36KV, minimum falling loud 70 KN, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 18 Nos. Excess(+) Full Conversion INR
30 v) Earth wire 7/4.00 mm sq. 58 Kg Excess(+) Full Conversion INR
31 vi) GI flat for earthing 50x6 mm 125 Kg Excess(+) Full Conversion INR
32 Part-B: Supply, Transportation & Erection of 33/11 KV, 6.3 MVA Power Transformer and 100 KVA Distribution Transformer i) 33/11kV, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Bimetallic Terminal connectors for Panther Conductor (6.3 MVA) 1 No. Excess(+) Full Conversion INR
33 ii)12 core 2.5mm² control cable copper Armoured 1.1 kv Grade,ISI, FRLS 250 mtr Excess(+) Full Conversion INR
34 iii) 6 core 2.5mm² control cable copper Armoured 1.1 kv Grade,ISI, FRLS 200 mtr Excess(+) Full Conversion INR
35 iv) 2 core 2.5mm² control cable copper Armoured 1.1 kv Grade,ISI, FRLS 300 mtr Excess(+) Full Conversion INR
36 v) 100 kVA,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminum wound) 1 No Excess(+) Full Conversion INR
37 vi) Servo Transformer 11/0.433kV 100 KVA 1 No Excess(+) Full Conversion INR
38 vii) GI Plate Earthing with GI Flat and GI pipe with earth enhancement material 1 No Excess(+) Full Conversion INR
39 Part-C- Supply & Erection of 11 KV Indoor Switchgear 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port compatible for SCADA 8 (16 Signals) For 6.3 MVA (1 Incomer Panel + 5 Outgoing Panels) 1 Set Excess(+) Full Conversion INR
40 11 kV Bus Coupler with Adaptor Panel 1 Set Excess(+) Full Conversion INR
41 11 kV Isolator, double break,3-pole, 600Amp, horizontal mounting Type, with Earth Switch. 6 Set Excess(+) Full Conversion INR
42 11 kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 1 No Excess(+) Full Conversion INR
43 9 Mtr. Long Pole (ST-410 SP33) 14 Nos Excess(+) Full Conversion INR
44 Galvanized iron of sorts 660 kg Excess(+) Full Conversion INR
45 Pipe Structures i) Nominal Bore 200, 5.9 mm thick 1.77 MT Excess(+) Full Conversion INR
46 ii) Galvanized Steel Structures 4 MT Excess(+) Full Conversion INR
47 iii) Galvanized Nuts & Bolts of Sorts 0.5 MT Excess(+) Full Conversion INR
48 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 14 Nos Excess(+) Full Conversion INR
49 Earthing of 100kVA substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip 50x6mm for neutral earthing, transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover. (3 No. Earthings) 1 Job Excess(+) Full Conversion INR
50 Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI strip 12 Nos Excess(+) Full Conversion INR
51 LT-DB Box with MCCB ‐ 4 P 200 Amps alongwith single pole 160 Amps MCCB for each face 1 Nos Excess(+) Full Conversion INR
52 Part-D: Erection of Tap line 13 Mtr. Long Pole(ST-410-SP69 26 Nos Excess(+) Full Conversion INR
53 GI channel /Angle X-sarm including clamps 2000 Kg Excess(+) Full Conversion INR
54 200 mm2 ACSR conductor 3 Km Excess(+) Full Conversion INR
55 11kv Polymeric composite Disc insulator 12 kv, min failing load 45kn,lighting impulse 75kv positive and 80 kv negative, creepage distance 320mm 24 Nos Excess(+) Full Conversion INR
56 Suspension fitting 12 Nos Excess(+) Full Conversion INR
57 Tension fitting 12 Nos Excess(+) Full Conversion INR
58 Galvanised Nuts and Bolts 300 Kg Excess(+) Full Conversion INR
59 Danger plates with Clamps 20 Nos Excess(+) Full Conversion INR
60 Anti-climbing Device with clamps 20 Nos Excess(+) Full Conversion INR
61 Earting complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip 20 Nos Excess(+) Full Conversion INR
62 Red oxide 20 Ltr Excess(+) Full Conversion INR
63 Aluminium Paint 20 Ltr Excess(+) Full Conversion INR
64 Cement bottoming 1:2:4 mix as per REC standards 0.7cum per pole 20 Nos Excess(+) Full Conversion INR
65 Aluminium jointing sleeves 4 Nos Excess(+) Full Conversion INR
66 Pin Insulators with Pins 48 Nos Excess(+) Full Conversion INR
67 Galvanised stay set with 50 x 8mm stay clamp,guy insulator(2Nos.),anchor plate(300x300x8mm),nut-bolts, 2 Nos turn-buckles ,1.8m long, 20 mm diameter solid GS stay rod &7/4.00 mm dia GI stranded wire complete 8 Nos Excess(+) Full Conversion INR
68 Guard netting 8 Span Excess(+) Full Conversion INR
69 Part-E- Miscellaneous Works Compound walling of identified land by way of Mass Concrete in Foundations and 228 mm Brick Wall of 2 M height including excavation and disposal of un-wanted soil. 300 RM Excess(+) Full Conversion INR
70 Chain link Fencing of 33 kV Yard of Substation by way of Mass Concrete in Foundations and chain link fencing of 6 ft height using angle of size 65x65x6mm And flat iron 50x6 mm 120 RM Excess(+) Full Conversion INR
71 RCC Cable trench (1:2:4) for laying of 11 KV XLPE Power Cable and control cable from power transformer, VCB and other equipments to control room and for outgoing cables from control room to outgoing structures including cable duct covers (cable duct covers should be framed using angle 50x50x6 mm and 8 mm Tar Steel including excavation and disposal of un-wanted soil. 100 RM Excess(+) Full Conversion INR
72 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Standard complete job (2 No foundations) 1 Job Excess(+) Full Conversion INR
73 33 kV RCC (1:2:4) Equipment Foundation & Gantry foundation as per REC Standard (VCB, Isolators, CTs, PTs, LAs, PI etc) complete job Job Excess(+) Full Conversion INR
74 Earthing Mat with GI Flat 75 mm x 8 mm (1 M x 1 M Mesh) inclusing back filling of good earth Job Excess(+) Full Conversion INR
75 Earthing Electrode ( GI Rod 32 mm 3 Mtr Long) through GI Strip. 60 No. Excess(+) Full Conversion INR
76 33 KV yard concreting and metalling providing supply and laying 100 mm thick PCC1:4:8 using 20 mm normal course aggregating and spreading 100 mm three layer of 20 mm single size crushed / broken stone 500 Mtr2 1 Job Excess(+) Full Conversion INR
77 Bore well with submersible pump (complete job) 1 No. Excess(+) Full Conversion INR
78 Design, Engineering and construction of Control Room building consisting of RCC Slab including trenches, comprising of Battery room, panel room, toilet complete in all respect with aluminum doors and windows, stair case, underground sewage tank, under ground water tank, overhead water tank, Motor pump for water lifting as required of overall building or as per electrical requirement ( single storey including all internal services like water supply including supply and fixing of pipes, water taps etc., electric fitting including wiring with fans, lights & switches, sewerage system, finishing plinth protection including supply of construction material, labour, cement, reinforcement steel, frame work etc complete in all respect 200 sqm Excess(+) Full Conversion INR
79 Shift Quarters for JE and SBA including washroom, pantry room, verandah above control room building (First Floor) 150 sqm Excess(+) Full Conversion INR
80 Yard Lighting of the new Receiving Sub Station using 4 No, 12 Meter Long, GI High Mast Poles, continuously tapered of octagonal of cross-section; including suitable shallow raft foundation using 8 Nos non integral flood light luminaries with single die cast aluminum housing and pot optic reflector and toughened glass cover, conforming to IP-66 complelete with all accessories bearing Cat No SGP 438 1xODM-II 250 watt GLA/HPI-T 250 W repeated make and suitable control feeder panel 1 job Excess(+) Full Conversion INR
81 Supply and installation of Split AC's in control room building along with Stabilizers (2 Tons) (5 Star rating) 5 No Excess(+) Full Conversion INR
82 Part-E- Battery Back & Battery Chargers a) Battery Bank 36 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type, High impact Polyprophelene copolymer container, flame retardant. b) 36V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 1 Set Excess(+) Full Conversion INR
83 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double bus bar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 1 No. Excess(+) Full Conversion INR
84 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnect or for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular bus bar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 1 No. Excess(+) Full Conversion INR
85 Telecommunication Facilities with internet & wifi facilities 1 Job Excess(+) Full Conversion INR
86 Rubber Mat 1mx2m 19mm thick 6 No Excess(+) Full Conversion INR
87 Fire Extinguisher Co₂ Type of 4.5 kg capacity for control room 6 No Excess(+) Full Conversion INR
88 3 Sand Bucket Fire Extinguisher 1 Set Excess(+) Full Conversion INR
89 Helmet 4 No Excess(+) Full Conversion INR
90 Rubber Gloves for 33 kV level 2 Set Excess(+) Full Conversion INR
91 Rubber Gloves for 11kV level 2 Set Excess(+) Full Conversion INR
92 Safety Belt 4 No Excess(+) Full Conversion INR
93 Safety Shoes 4 No Excess(+) Full Conversion INR
94 Earthing rod (set of 3 rods) 1 set Excess(+) Full Conversion INR
95 HV Detectors all voltages 1 No Excess(+) Full Conversion INR
96 Part-F Installation of Capacitor Bank 12 kV, 2.4 MVAr Capacitor Bank with VCB Panel with complete arrangement for connection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Power Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 1 set Excess(+) Full Conversion INR
97 Part- G RMU Works 33 kV, 3 core 400sq.mm XLPE insulated Roundwire armoring cable for RMU 400 Mtrs Excess(+) Full Conversion INR
98 33KV Isolator with earthing blade 2 Nos Excess(+) Full Conversion INR
99 11kV indoor cable termination kit 1 Nos Excess(+) Full Conversion INR
100 3Cx400 sqmm touch proof cable termination of C-type bushing (conforming as per EN50180/EN50181) Termination kit shall be strictly screened separable cable connector termination (touch-proof)/ inner cone push on type (touchproof) (Raychem make) for 33kV RMU 5 Nos Excess(+) Full Conversion INR
101 33kV RING MAIN UNIT : 3 way Outdoor type RMU,SF6 Insulated, extensible type, at 33kV system voltage and breaking capacity 25kA for one second, with SF6 circuit breaker / VCB self powered with O/C + E/F Relay system comprising of a) One (1) Nos. 33kV, 630 Amp. motorized Isolators including earthing switches with making capacity 62.5kA, having mechanical ON/OFF b) Two (2) No. 33kV, 200Amp motorized, spring operated, Circuit Breakers (CB) with earthing switches c) Cu Bus - Bar of 630 Amp. rating d) One (1) No. Numerical Aux. self powered relay having non-directional 0/C and E/F protection (for each Circuit Breaker feeder). Relay should have minimum 7-DI & 8- DO. The relay shall also interface via an RS 232/485 port in order to send, as a minimum, real-time readings using the MODBUS protocol. e) Incoming Isolators shall have FPI with electrical reset contact / facility. f) All necessary potential-free contacts for indications relevant to RMU monitoring and control. g) Capacitor Voltage Dividers serving live-line cable indicators in each Breaker & Isolator. 1 unit Excess(+) Full Conversion INR
102 33 KV 3 phase indoor terminating kit to be used with cables - 400 sq.mm. 3 set Excess(+) Full Conversion INR
103 33 kV 3 phase outdoor terminating kit to be used with cables - 400 sq.mm. 3 set Excess(+) Full Conversion INR
104 Cable route Markers. 3 No. Excess(+) Full Conversion INR
105 Excavation in any type of soil including hard laterite soil. 12.49 cub mtr Excess(+) Full Conversion INR
106 Refilling of excavated soil 9.5 cub mtr Excess(+) Full Conversion INR
107 Sand for cushioning of the cables in the trench. 1.72 cub mtr Excess(+) Full Conversion INR
108 Cement Tiles of size 300mm length x250mm width x 37mm thick as a protective cover for underground cables. 25 No. Excess(+) Full Conversion INR
109 Earthing of RMU --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mmx10 mm & 50 mmx6 mm for connection of rmu body as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonry with RCC slab cover. 3 no Excess(+) Full Conversion INR
110 Cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations) Cu.mtr Excess(+) Full Conversion INR
111 Centering and shuttering including struttings, propping etc and removal of formwork. Sq.mtr Excess(+) Full Conversion INR
112 15 mm cement plaster 1:4 (1 - cement: 4 -fine sand) for foundations. Sq.mtr Excess(+) Full Conversion INR
113 Wire mesh boundary fencing around the RMU 1 lump sum Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
SBD28of2025.pdf
Tender Documents • 0.88 MB
GTP28of2025.pdf
Other Document • 0.45 MB
BOQ_982858.xls
BOQ • 0.30 MB
GTPPOWERTRANSFORMER.pdf
PDF • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .