Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.8 LAccepted-AOC VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | ₹6.8 L Quoted ₹7.0 L | 1 | Accepted-AOC BEING LOWEST |
| 2 | 2₹7.5 L+₹47,488 (6.78%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | ₹7.5 L+₹47,488 (6.78%) | 2 | Rejected-Finance BEING NOT LOWEST |
| 3 | 3₹7.6 L+₹55,421 (7.92%)Rejected-Finance MOH HATHITHAN NIGOHI ROAD SHAHJANPUR UP 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | ₹7.6 L+₹55,421 (7.92%) | 3 | Rejected-Finance BEING NOT LOWEST |
| 4 | 4₹7.7 L+₹70,266 (10.0%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | ₹7.7 L+₹70,266 (10.0%) | 4 | Rejected-Finance BEING NOT LOWEST |
| 5 | 5₹8.8 L+₹1.8 L (26.2%)Rejected-Finance | ₹8.8 L+₹1.8 L (26.2%) | 5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
3 Apr 2023, 6:00 pmClosed
AGE(I) Fatehgarh
AGE(I) Fatehgarh
REPAIR/MAINT OF CEILING FANS, EXHAUST FANS AND WALL MOUNTED FANS AND OTHER CERTAIN MISC WORKS AT FATEHGARH CANTT UNDER AGE (I) FATEHGARH.
2023_MES_584489_1
AGE(I)/FAT/ET-40 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE(I) Fatehgarh
PLEASE REFER TO TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Fatehgarh
₹20,000
Yes
29 Apr 2023
6 Mar 2023
10 Apr 2023
6 Mar 2023
3 Apr 2023
21 Mar 2023
6 Mar 2023 - 20 Mar 2023
Amount
Taking down ceiling fan any size from fan hook and disconnection from ceiling rose and dismantling of ceiling fan parts i e. down rod and connector/condenser nut bolts, split pins, rubber bush (garari) condenser carrier clip (PVC) in build connector two way complete servicing by cleaning greasing/oiling before in side surface by CTC with sand paper and repair and re - fitted the same position and testing complete all as specified and directed on site. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately under supply only items.
Taking down Exhaust fan any size and disconnection from ceiling rose and dismantling i.e connector/condenser nut bolts, condenser carrier clip (PVC) in build connector two way complete servicing by cleaning greasing/oiling before in side surface by CTC with sand paper and repair and re - fitted the same position and testing complete all as specified and directed on site (Note: - condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately under supply only items.
Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm (collected from MES fan store) any make / model except old vintage, dismantled its stator,rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish as aproved by Engineer - In - chargee cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and deposited to MES store after testing complete all as specified and directed by Engineer -In - charge.
Ditto as above but for sizes 400/450mm sweep Ac single phase 230/240 volts….ditto….
Ditto as above but for sizes 300/380mm sweep Ac single phase 300/380mm….ditto….
Ditto as above but for sizes 230/250mm sweep Ac single phase 230/250mm sweep ….ditto….
S&F condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F upper set of clips for down rod with rubber Bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F rubber bush ( Garari ) for mounted at upper side of down rod clip all as specified and directed
S&F gun metal bush self lubricated, any size ,suitable for ceiling and wall fans complete all as specified and directed
S&F flexible copper conductor stranded 1100 Volt PVC insulated cable three core, complete all as specified and directed.
Supply only Fan condenser of 2.5 MFD capacity , 230 Volts complete all as specified and directed.
Supply only Fan condenser of 3.15MFD capacity , 230 Volts complete all as specified and directed.
S&F ball bearing of size NBC/ SKF - 6201'ZZ'
S&F ball bearing of size NBC/ SKF - 6202'ZZ'
S&F ball bearing of size NBC/ SKF - 6203'ZZ'
Supply and fixing Exhaust fan blade duly painted suitable for 450 mm/380mm sweep complete all as directed .
S&F of fan blade suitable for 1200mm sweep ceiling fan complete similar to original make with new screws Complete all as specified and directed.
Supply and fixing outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as directed .
Supply and fixing in repair to PCB for BLDC Ceiling Fan of capacity 1200mm sweep complete all as directed .
Supply & Fixing modular fan regulator Fan step regulator, 120W - 2 module,
S & F Five Stepped type electronic fan regulator flush type 120 watt 240 Volt on the existing phenolic laminated sheet 50hz AC complete all as specified and directed,
Dismantling of wall mounted Fan of any sweep and rewinding the stator with super enameled Copper Winding Wire of suitable size including oiling & greasing, cleaning of all components of fan reassembling , testing, commission complete all as specification and directed.
S & F in repair of down rod for ceiling fans duly painted with synthetic enameled paint 300 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specification and directed.
S/F in repair PVC canopy of suitable size for 1200/1400mm sweep ceiling fan complete all as specified and directed.
Removing unserviceable bearing shaft welding broken area and threading in lathemachine at appropriate size and refixing in ceiling fan any type complete all as specified and directed.
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and as directed .
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) not less than 20 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc for the One light/ holder/fan/exhaust fan point controlled by one switch controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
…...ditto as above….but one 5 pin 5 Amp switch socket combination point on an independent board complete all as specified and as directed.
..…ditto as above…. but one 5 pin 5 Amp socket point controlled by one switch on same board complete all as specified and as directed.
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed.
S&F switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
S&F of square slim surface mounted LED down lighter of capacity 15 watts, 240 volts, white powder coated pressure die cast aluminium housing and bottom frame with high transmitive LGP technology, high efficiency non yellowing PMMA diffuser, complete with LEDs driver and accessories pre-wired upto terminal block lumens wattage not less than 15 watts, luminaire lumen output >1500 Lm, ingress protection IP-20, ambient temperature 0-450 C driver efficiency more than 85% power factor above 0.95, Surge protection 3 KV multi stage isolated constant current and variable working votlage 150-270 Volts complete all as specified and directed.
M & L lamp holder PVC/Polycarbonate type insulated body with back plate angle type for batten fittings incl LED lamp of 9 W and colour temp 6500K suitable to fix in angle holder complete all as specified & directed.
Supply and fixing of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and as directed.
S&F in repair MCB SPN 40-63 Amp 240 volt 'C' 10 KA curve complete all as specifed and directed.
S&F in repair MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
MS. BK BROTHERS AND CO
avon electric engineering woks
M/S CHAUHAN ELECTRIC WORKS
M/S J.B.AND SONS
LARSEN AIR CONDITIONING & REFRIGERATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .