Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹18.7 L+₹1.0 L (5.67%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹19.4 L+₹1.8 L (9.92%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹22.4 L+₹4.8 L (26.9%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | Rejected-Technical NEAR MOHANPURA BALAJI ROAD TEH KISHANGARH RENWAL DIST JAIPUR 303603 | JAIPUR | RAJASTHAN | 303603 | - | Rejected-Technical Firm not enlisted in relevant category a i |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
28 Jun 2023, 6:00 pmClosed
Garrison Engineer
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
COMPREHENSIVE REPAIR OF B/R AND E/M NATURE OF WORK FOR ZONE B AT RLT VIHAR MD ACCN UNDER GE (NORTH) AKHNOOR
2023_MES_599861_1
CANO- GE(N)/AKH-19/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
AoR of GE (N) Akhnoor
Class D Category a(i)
9 documents required · 9 mandatory
₹500
GE (North) Akhnoor
₹54,000
Yes
29 Aug 2023
31 May 2023
5 Jul 2023
31 May 2023
28 Jun 2023
14 Jun 2023
Amount
B/R Portion:- Taking down old treatment incl padding, sunken floors ,removing existing bitumen felt treatment incl brushing,cleaning top surfaces of roof slab, broming etc complete all as specified.
Rendering 10mm thick cement plaster with cement mortar(1:4) on fair finishes of brick work or concrete surface of roof slab, complete all as specified.
Sunken Floor treatment :- (a) Apply a coat of biruminous primer conforming to IS - 3384 @ 0.40 Kg/Sqm on prepardd surfaces. (b) After drying of primer apply a coat of hot blown 85/25 penetration grade blown bitumen conforming to (IS-702 @ 1.20 Kg/Sqm of surfaces. (c) Provide APP modified polymeric five layed membrane with central core of 100 micron high molecular high density film. Minium width of APP modified water proofing membrane shall be 3 Kg per Sqm. Product Name Multi p[lus manufactured by M/S STP texa Ltd Gurgoan/Hyper Plus Standard Manufactured by IWL India ltd Chennai, Bengal Acquaflux manufactured by Bengal bitumen New Delhi/Superior plus 310 by STP Lfd and any other product as appproved by E-in-C Br will be used. APP membranne will be laid across the slop from lowest line of slopping roof toward ridge with minimum end lap of 150mm and side lap of 75mm bonded with hot blown. (d) Over the APP membrane apply semi hot blown 85/25 grade bitumen penetration of bitumen when tested as perIS 1203 will not be more than 40/Confiming to IS 702 @ 1.20 Kg/Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bvitumen coat.
(e) Coved fillet in PCC (1:2:4) type BO radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall around opening and treatment mentioned above (except fine sand) shall be applied followed by a cement plaster 20mm thick in CM 1:6. Note :-Concrete for sunken slabs shall be mixed with WP comounds as manufacturdrs instructions before carrying out water proofing treatment the sunken slab slab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested ( Water proof compound rate is not paid seperatly.)
Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
Rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brick work or concrete surfaces and finished the surface even and smooth without using extra cement, complete all as specified.
Rendering 10 mm thick cement plaster with cement mortar(1:6) on other than fair faces of brick or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified
Applying wall care putty of approved make not less than 1-2mm thick on walls as per manufacturar instructions with and including rubbing by means of sand / abrasive paper to have smooth finishing to receive primer / paint, complete all as specified.
Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished the surface even and smooth without using extra cement, complete all as specified.
Complete removal of exising treatment from old vertical surfaces and apply two coat of cement base paint to walls, complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over one coat of approved primer all as speicfied and directed.
Preparation of old plastered surfaces of walls and applying two coat of oil bound distemper, complete all as speicfied and directed.
Peparation of new plastered surfaces and apply two coat of cement base paint to walls over & including one coat of approved primer all as specified and as directed.
Preparation of new plastered surface and apply two coat of Oil bound distemper on ceiling, complete all as speicfied and directed.
Preparation of old treated surface and apply one coat of oil bound distemper on ceiling, complete all as speicfied and directed.
Curtain rail ,20 mm dia Stainless steel ,cromium plated fixed with braket, incl taking down of old curtain rods, complete all as directed.
Providing cement concrete type C-1, 1:3:6 ( using 20mm graded crushed stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified & directed.
Rotational moulded polyethylene water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified & directed.
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified & directed.
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal unsv pipe with all fittings from site, complete all as specified and directed.
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal unsv pipe with all fittings from site, complete all as specified and directed.
Steel water tubing 20mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified.
Steel water tubing 15mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified.
15mm bore Stop valve cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified.
20mm bore Stop valve cast copper alloy screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified.
20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) fixed in repairs, complete all as specified
PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections fixed in repairs, complete all as specified.
Vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'S' trap fixed in repairs complete all as specified and directed. Cat Part No-20042 (ORISSA PAN (ECO)) of Hindware or equivalent cat part of make specified in list make as approved by GE.
PVC connection 15mm size with PTMT nuts on both ends of length 450mm fixed, complete all as specified.
Stainless steel gratings 100mm dia with hole and fixed with cement motar, complete all as specified.
Swivel shower of PTMT any colour for fixing with 15 mm pipe ,with shower arm of size 195 mm long with bend of 54 degree with flange of any colour (minimum weight 40 gm), fixed in repairs complete all as specified.
Plate rack made of stainless steel 0.8mm thick overall size 786mm x 610mm x 254mm complete all as specified and directed.
kitchen sink bowl with drainage board gloss finishing stainless steel 1.00 mm thick sheet for kitchen with plugs, washers and wastes including fixing in reinforcement cement concrete slab and connecting union to pipe overall size 1040mmx510mm, bowl size 510mmx4050mmx203mm fixed in repairs, complete all as specified.
15mm bore Stop valve cast copper alloy chromium plated fancy type with long shank and cup (concealed type) screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified. Make:- Jaquar cat part No CON-069KN or equivalent cat part of make as specified in P.S..
Bib tap 15 mm bore with flange, Brass CP, fancy type. with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed in repairs, complete all as specified. Make:- Jaquar cat part No CON-107KN or equivalent cat part of make as specified in P.S..
Brass cromium plated wall mixture with Telephonic shower arrangement for mixing hot cold water supply screwed down incl connecting legs & wall flanges for iron pipe 15mm dia bore fancy type fixed in repair complete all as specified and directed. Make:- Jaquar cat part No CON-217KN or equivalent cat part of make as specified in P.S..
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified.
Description all as per item No.37 above, but except bricks, all as specified and directed.
Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5Sqm and not exceeding 4Sqm each, complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5Sqm each, complete all as specified.
Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
Steel windows/ventilator (Box type) factory made without glazing bars shutter only complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
Galvanised steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm all as specified and as directed by Engineer in charge.
Sheet glass ordinary quality, 4mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and as directed.
Figured glass pin headed type, 4mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified.
Dismantling of wall and ceiling boards ( fibre ,pulp, insulation,etc,) or insulation boards/slabs/blankets any thickness,including cover fillets, complete all as specified.
GI frame work 605 x 605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre intermediate channel 0.9mm thick having two equal flanges of 15mm each web of 45mm suspended from sofit itat approx x 900mm c/c with GI cleat and steel expansion fasteners with and including celing section (n.exc 1.2m length) of 0.55mm thickness having kruled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 c/c incliding 4mm thick Non absetos desinger board in grid and applying three coats of white wash including preparation of surfaces.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store andd rubbish off the premises
Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with & including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified.
Glazed ceramic tile 450mmx350mmx6-7mm thick (coloured) on vertical surfaces such as dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4, complete all as specified.
Repair to balcony/Facia/parapet and soffit of chajjas etc by taking down old rendering 15 mm thick incl dubbing coat where required to match with the existing thickness in CM 1:4 and hacking clearly the edges and corners smooth and rounded for new plastered including formwork/scaffolding work upto height 3.5mtr above ground level of bldg complete all as specified.
Description all as per srl item No 52 above but ht exc 3.5m but n.exc 7.0m
110mm bore PVC SWR Type B pipes ( pressure not less than 4 kg /cm2) single socketed in vertcal length for Rain water fixed with rubber joints in wall etc. in repairs, complete all as specified and directed.
PVC SWR Type B ( pressure not less than 4 kg /cm2) bends any radius 110 mm bore fixed in repairs, complete all as specified.
Hacking out old broken galss (any thickness, size, quality or description) for metal frames including punching or drilling out old glazing pins/spring clips and provding and fixing new ones Sheet glass ordinary quality, 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and as directed.
Preparation of new or previously untreated steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer, complete all as specified and as directed.
E/M Portion:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:-
One light / fan point / bell point controlled by one way switch 6 Amp complete all as specified.
One 3/5 pin socket outlet 6 amp independent board, complete all as specified.
One 3/5 pin socket outlet 6 amp on same board complete all as specified.
Description all as per srl item No 34 here in before but for one 3 pin socket outlet 16 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 1.5 Sqmm as in continuous earth wire. (Note for item No-59 to 60:- All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used of same make/brand only and shall be deemed in to be included in quoted rate only.)
Modular type switch 6 Amps, single pole,1way,1 module, 240V, ISI Marked Complete all as specified and directed. “Cat part No ACVSXXWO61 of Crabtree (Havells) or its equivalent cat part of make Anchor, Legrand, Schneider as approved by GE”.
Modular type switch 16 Amps, single pole,1way,1 module, 240V, ISI Marked Complete all as specified and directed. “Cat part No ACVSXXW161of Crabtree (Havells) or its equivalent cat part of make make Anchor, Legrand, Schneider as approved by GE”.
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed. “Cat part No CVKSWW063 of Crabtree (Havells) or its equivalent cat part of make make Anchor, Legrand, Schneider as approved by GE”.
Modular type socket 6 Amps /16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and directed . “Cat part No ACVKCWW163 of Crabtree (Havells) or its equivalent cat part of make make Anchor, Legrand, Schneider as approved by GE”.
Fan regulator modular type electronic, stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and directed. “Cat part No ACVRFHW008 of Crabtree (Havells) or its equivalent cat part of make make Anchor, Legrand, Schneider as approved by GE”.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed by Engineer-in-Charge.
Modular Bell push 6A 1 module, 240V, ISI Marked Complete all as specified and directed. “Cat part No ACVSBXW061 of Crabtree (Havells) or its equivalent cat part of make make Anchor, Legrand, Schneider as approved by GE”.
Ceiling rose, 3 phase PVC/poly carbonate, insulated body, compete all as specified.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning fixed in repairs, complete all as specified. Make:- Havells cat part No-DHDPSHODPW08 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
MCB single pole & neutral 6 to 32 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified. Make:-Havells cat part No-DHMGCSNF006-032 or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
MCB single pole and neutral 63 amps 240 volts 10 KA 'C' series, complete all as specified. Make:- Make:-Havells cat part No-DHMGCSNF063 or its equivalent cat part of make-Legrand / ABB / L&T as approved by GE
Metal type exhaust Fan 450mm sweep 900 RPM, 240 volts, single phase including all connecting accessories fixed in position & making electrical connection / testing, complate including Taking down old unsv exhaust fans of any type and size after disconnecting the connections from existing location and deposite in Mes store yard, complete all asspecified.
Taking down old unsv submain wiring and M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as bend,Tee, elbow, short peices etc concealed in wall/roofs/floors including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 metre below normal ground level, connected to and including galvanised iron wire 4mm dia and light grade protection pipe of 15mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20mm dia medium grade, GI funnel with wire mesh, including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45x45x45 CM, RCC cover 1:2:4 type B1 of size 45x45x6 CM with 8mm TMT bar @ 100mm C/C, excavation/earth work in any strata and returing filling, removal of surplus soil and testing/test point for required value including taking down old unsv earthing, complete all as specified and directed.
Surface mounted, decorative hexagon bulk head Back-lit LED luminaire comprising of high brightness LEDs. with & including 10W LED lamp and making connection with copper flexible cable of suitable size to light fitting fixed in repairs, complete all as specified and directed. Make: Havells Cat Part No HEXAFT10WLED857SSYMBOPC or Equivalent cat part of make:-Wipro / Crompton / Bajaj / Philips.
Tube light fitting with universal batten suitable for T8 LED lamps LED 20W tube Rod with end cap complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including 20LED tube rod 4 feet long (Double Side Connection) fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part No:-REGALBATTENT8UPTO1X22WSSBSWH for fittings & CRYSTAL 1213T8DSTL20WLED865SGLASS for LED tube rod or Equivalent cat part of make:-Wipro / Crompton / Bajaj / Philips. Note :- The LED batten and LED tube rod shall be of same make.
harish kumar and co
M/s Kuldeep Kumar Sharma
M/S Mahajan Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .