GE Jammu
GE Jammu PIN-180003
PROVISION OF COVER SHED, GYM, JAFRI WALL AND OTHER MISC WORKS AT PCDA COMPLEX UNDER GE JAMMU
2025_MES_738118_1
GEJC-66/2025-26
Open Tender
Civil Works
Item Rate
180 days
AOR of GE Jammu
As per NIT
8 documents required · 8 mandatory
₹500
GE Jammu
₹86,400
Yes
21 Nov 2025
1 Nov 2025
24 Nov 2025
1 Nov 2025
21 Nov 2025
14 Nov 2025
Excavating in post holes (or for similar work) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed.
Cement concrete Type B2 1:2:4 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Cement concrete in foundations, filling and mass concrete, PCC 1:3:6 type C2 (40mm graded aggregate) complete all as specified and directed.
GI tubular sectiones cut welded and moulded to any shape , trusses, posts, rafters purlins etc complete all as specified and directed.
Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 MPs as in roof covering fixed with self tapping screws or L-type or J-type or cranked hook bolts complete all as specified and directed.
Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 MPs as in ridge of roof fixed with self tapping screws or L-type or J-type or cranked hook bolts complete all as specified and directed.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including shop coat of primer complete all as specified and directed.
Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed.
Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
Mild steel bolts.purpose made with hexagonal orsquare head one end and screwed the other, orscrewed both ends;each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long (dia of necxk exe 12 but n exe 20 mm) compolete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm all as specified and directed.
Removing excavated material exc. 50m & depositing where directed at a level nexc. 1.5m above the starting point.
PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in mass concrete in foundation) complete all as specified and directed
Brick work with sub class 'B' old size brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:6 complete and fixed all as specified and as directed.
RCC 1:2:4 Type B-1 ( using 20 mm graded stone aggregate as in foundations/ plinth beams complete all as specified and directed.
RCC, type B1, 1:2:4 mix (20mm graded aggregate) as in lintel beams, roof beams supported on walls as for roof slabs, lintel etc complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Rendering 15mm thick on fair faces of brick/ concrete surfaces built in cm (1:4) , finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 15 mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Prepartion of new surace and applying two coat of oil bound distemper new plaster surface over 1 mm thick putty complete all as specitied and directed.
1mm thick wall care putty over external wall/ceiling surfaces and smoothing/preparing wall surfaces for exterior emulsion paint complete all as specitied and directed.
Preparation of new steel surface and applying 2 coat of epoxy paint over a coat of primer complete all as specitied and directed.
Applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specitied and directed.
Powder coated aluminium three track sliding type glazed window,shutter with 5mm thick plain sheet glass fixed open track section 100x38mmx1.2mm having three track (two of glass & one of stainless steel wire cloth of 0.36mm nomina dia if wire and average width of aperature 2mm) with members of window shutters of section 38x12mm including,wire gauge and grill shall be fixed with the help of 40 mm aluminium flat and other standard Bombay sliding section incl all necessary fiber wheel rollers suitable handle to facilitate sliding and all necessary jointing cleats glazing clips,rubber packing, aluminium snap beeding etc complete all as specified and directed .
Preparing surface of new steel material of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint complete all as specified and directed.
Powder Coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed.
5.5mm thick frosted/tinted glass ordinary quality and glazing with oil putty / beads in squares exe 0.5 sqm each pane complete all as specified and directed.
Dismantling Stone slabs laid dry and tiles of any description or thickness in floors, aprons etc. and rubbish off the premises complete all as specified and as directed.
Demolition cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
100mm thick PCC type D-2, 1:4:8 (40mm aggregate) in floor as sub base complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and providing necessary hangers/ suspenders for the frame work all as directed by Engg in Charge.
Providing and fixing gypsum board 12mm thick in ceiling fixedwith screw as per manufacturers instruction complete all as specified and directed.
Providing and applying plaster of paris putty of 1 mm thickness over gypsm board to prepare the surface even and smooth complete all as specified and directed.
Finishing ceiling with textured paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of primer applied @ 2.20k
g/10 sqm complete all as specified and directed.
M&L for 16 mm thick rubber tile flooring suitable for heavy industries and equipment usage, gyms etc complete all as specified and directed.
RCC Type B-1 (1:2:4) using 20 mm graded stone aggregate as in coping, bond stone etc. complete all as specified and as directed.
Providing precast cement concrete of mix 1:3:6 using 12.5 mm graded aggregate louvres and jallies, 25mm thick (measured solid), ncluding all mouldings but excluding frame set in CM 1:6 complete all as specified and directed.
E/M Portion-: Point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including medium grade PVC conduit 25 mm dia concealed, with cutting chases and making good disturbed surface complete including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn same conduit with modular CI / pressed steel sunken terminal boxes of required size with modular cover plate with frame for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note :1) Wiring shall be done in proper colour coding. 2) Rates are inclusive of cutting / chasses withsuitable PCC works and making good to disturbed surfaces.
Use and waste form work to side and soffit of floor or roof beam , beam hanching, girders, bressummers, lintels, cantilevers, shelves including spport, over hangs also splays between floors and beams complete all as specified and directed.
All as per item No 48.00 above but for multi 5 pin 5 amp socket outlet on same board without inverter wire complete all as specified and as directed.
All as per item No 48.00 above but for multi 3 pin socket outlet 5 amp socket on independent board with inverter wire complete all as specified and as directed.
All as per item No 48.00 above but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 sqmm copper conductor multistrand cable pvc insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 25 mm dia and unsteathed copper conductor multistrand cable 2.5 sqmm as earth wire FRLS pvc insulated in green color all as directed by engr-in-charge.
Modular Socket, 6A - 5 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Modular switch 1 way 6A,1 module , 240 volts ISI marked complete all as specified and directed.
Ceiling rose, 3 Phase/PVC/polycarbonate isolated body complete all as specified and as directed.
Modular switch 1 way 16A, 1 module , 240 volts ISI marked complete all as specified and directed.
Modular Socket 6A/16A - 6 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed.
Socket outlet 2 in 1 , 3 pin , 5 Amps , 240 volts complete all as specified and as directed.
Socket outlet 5 pin, 15 Amps , 240 volts flush type complete all as specified and as directed.
Switch piano , flush type, single pole one way 5 Amps , 240 volts complete all as specified and as directed.
Switch piano , flush type, single pole one way15 Amps , 240 volts complete all as specified and as directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
LED lights fitting 1x 20W, 220V, AC decorative type complete with LED tube rod 20 watts driver, holder and power factor >0.95 , 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz. complete all as specified and as directed.
XLPE Insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium con
LED flood light fitting of capacity 170 watt incl inbuilt surge protection as per requirement LED flood light fittngs along with IP 65/66 protection complete all as specified and as directed.
LED light fitting 1x9 watt/1x10 watt bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
ductor 1100 V grade cross sectional area 16 Sqmm, 2 core in and incl taking out old unsv all as specified and directed.
Excavating in trenches, n.exc. 1.50m wide and n.exc. 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes pier holes, etc. n exc. 10 sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete as specified and as directed.
Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 4 Sqrmm for phase and neutral and one run of 4 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length incl taking down old wiring complete all as specified and as directed. Note : Wiring shall be done in proper colour coding.
Ceiling fans complete with blades, hanging hooks and accessories, Fan regulators, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). Incl checking of electric supply to the fan point and hanging of new fans on new hooks with down rod as per site requirement complete all as specified and directed.
Distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as directed by Engr-in-Charge. Note:- Distribution board and MCBs should be same make.
MCB SPN 40 to 63 Amp rating 240V, 10KA 'B' curve complete with connection testing and commissioning complete all as specified and as directed.
MCB 240V, 10 KA 'B' curve of single pole and current carrying capacity 6 to 32 AMP Complete with connection testing and commissioning complete all as specified and as directed.
Hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary of capacity 1.5 Ton complete all as directed by Engr-in-Charge.
Double pole and neutral enclosure with a two pin and earth plug and socket complete with 25 Amp MCB Modular type for split type Air conditioner complete all as directed by Engr-in-Charge.
Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 2.5 Sqrmm for phase and neutral and one run of 2.5 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length incl taking down old wiring complete all as specified and as directed. Note : Wiring shall be done in proper colour coding.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and desigend for input variation between 110 V to 250 V with out put voltage stabilized at 230 V with accuracy of +/- 2.5 % and of capacity 5 KVA complete all as directed by Engr-in-Charge.
Sand coushioning with dry and clean over and under the cable for protection of cable , 180 mm sand laid before laying the cable & 150 mm sand after laying the cable and filling the sand in cable duct inside the sub station building complete all as directed by Engr-in-Charge. Note-: Punned thickness shall be measured.
Bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
Modular fan step regulator, 120W-2 module complete all as specified and as directed.
GI tubing light graded 32 mm dia incl all accessories for encasing cables for mechanical protection, laid under plinth/floors/path culverts with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed.
LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Cutting of existing road/floor/plinth/drain for taking out /laying of UG cable throgh GI pipe inclding necessary earth work , excavation and making good to match with existing surface complete all as specified with PCC 1:3:6 type- C1 (using 20mm graded crushed stone aggregate ) complete all as specified.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.17 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_826509.xls
BOQ • 0.45 MB
TENDER66.pdf
Tender Documents • 1.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .