| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹42.5 L+₹4.2 L (10.9%)Rejected-Finance NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L2 | Rejected-Finance Being Not L1 Bidder | |
| 3 | L3₹61.9 L+₹23.7 L (61.9%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 Bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
1 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DSSC
GE DSSC WELLINGTON BARRACKS-POST, WELLINGTON, THE NILGIRIS, TAMIL NADU,PIN-643231
AUGMENTATION OF ELECTRIC SUPPLY AT PRODUCTION DEPT SUB-STN AND SUB-STN NO-05 (GH) INCL CONNECTED WORKS UNDER GE DSSC WELLINGTON.
2021_MES_479558_1
8199/E8
Open Tender
Civil Works
Item Rate
120 days
WELLINGTON
PLEASE REFER TENDER DOCUMENTS AND NIT
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹78,000
Yes
13 Nov 2021
4 Oct 2021
4 Nov 2021
4 Oct 2021
1 Nov 2021
18 Oct 2021
60 days
Amount
Supply, install, testing & commissioning of transformer platform/plinth mounted of capacity 250 KVA step down, BEE 5 Star Rated (Energy Efficiency Level 2), outdoor type 11.0/0.433 KV, 50 Hz, AC double wound core type, copper wound, oil immersed type, naturally air cooled with external cooling tubes, transformer delta connection on HT side & star connection on LV side in accordance with vector symbol DyN 11 (vector group - 4) with off-load tap changer on HT side to vary secondary voltage +/- 7.5% in equal steps of 2.5% as per IS – 1180 (Part-I) - 2014. The voltage regulation shall be as per IS incl first fill of transformer oil upto appropriate level all as per IS-335 all as specified & as directed. Make : Vol Amp Vadodara /ABB /Siemenss /CG /BHEL /Bharat Bijilee /Essner Transformer or technocommercially equivalent comprising with & incl the following specifications :
(a) 01 No cable end box on HT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers & cable glands suitable for reception of HT 11000 V grade XLPE insulated heavy duty cables incl glands complete. (b) 01 No cable end box on LT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers & cable glands suitable for reception of LT 1100 V grade XLPE insulated heavy duty cables incl glands complete. (c) Oil conservator with filter type drain valve & oil level gauge. (d) Explosion vent with double diaphragm & sight glass. (e) Thermometer pocket. (f) Two earthing terminal on tank body to facilitate fixing of 32 x 6 mm GI strip etc. (g) 01 No thermometer dial type, vapour pressure type having range 0 to 120'C with maxm temperature indicator, re-setting device & marked maxm temp reading point. (h) Rating plate with terminal marking plate.
(j) Oil level gauge. (k) Oil drain filter valve. (l) Oil filling port on top cover with plug. (m) Air release valve / plug. (n) 04 Nos plain solid cast steel detachable rollers. (o) First fill of transformer oil confirming to relevant IS & tested upto 60 KV dielectric strength. (p) Inspection cover. (q) Lifting lugs & jack lifting pad & support. (r) Silica gel breather without / with connecting pipes, first fill of dehydrating agent. (s) Cover lifting eyes. (t) Oil temperature indicator of approved range, incl shut off valve between conservator & main tank. (u) Additional / Extra bushing for neutral outside of LV side.
Note: (i) Design / drawing / BOM of the Transformer showing the dimensions is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-in-Charge before placing final order to the manufacturer. (ii) Quoted rate is deemed to be inclusive of Factory Inspection/Testing of the Transformer before dispatch by an E/M Officer nominated by the Accepting Officer. (iii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. (iv) Contr/Firm is required to visit the site of work for any doubts/clarifications w.r.t. specifications/qty etc. before quoting of the Tender. Any query/clarifications etc. after conclusion of the Contract shall NOT be entertained & decision of the AO shall be final & binding.
Supply, install, commissioning and testing of Outdoor Type with Motorized mechanism, right side extensible Ring Main Unit comprising of 2 I/C + 2 O/G with Vacuum Circuit Breakers of Nominal Voltage - HT 11 KV, 630 A, 50 Hz, 21 KA rms for 3 Sec, rated lightning withstand voltage - 75 KVp, rated power freq withstand voltage - 28 KV rms for 1 Min, rated peak current - 50 KA all as specified & as directed. Make : SCHNEIDER/ABB/SIEMENS with & incl the following items/specifications :
(a) Each Module of HT Compartment function unit must comprise of a Vacuum Circuit Breaker in combination with a three-position-switch. The three-position-switch must fulfill the operations of disconnector function & earthing function. (b) Details of items/eqpts in each Module of HT Compartment function is as follows : (i) Vacuum Circuit Breaker, 11 KV, 630 A, 21 KA of make SCHNEIDER/ABB/SIEMENS. (ii) Integrated manually operated earth-switch. (iii) Self powered Electronic Numerical Protection Relay providing Over-Current & Earth-Fault Protection of Make C&S (CSPR or CSDPR Relay) or techno-commercially equivalent. (iv) 03 Nos of Ring Core type CTs of protection ratio 50-25/1+1A, AC of Class : 10P10-5P10, Burden : 2.5VA. (v) Capacitive Voltage Indication, fixed type : LED Display. (vi) ON, OFF, Earth Indication on the front mimic of the panel. (vii) Cable Box for termination of HT 11 KV (E) UG Cable upto 1 x 3C x 300 Sqmm. (viii) Standard cable cover. (ix) Shunt Trip Coil - 24V DC. (x) Set of 2 NO + NC Contacts. (xi) Emergency Trip Push Button. (xii) Set of 11 KV Boots.
Note: (i) Design/drawing/BOM of the RMU showing the dimensions is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer. (ii) Quoted rate is deemed to be inclusive of Factory Inspection/Testing of the Transformer before dispatch by an E/M Officer nominated by the Accepting Officer. 3) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. (iii) The complete installation, commissioning & testing of the RMU Panel is to be got done from the OEM or their auth Rep/Sister Concern/Channel Partners only. (iv) Necessary PCC foundation/plinth shall be as per the recommendations of OEM & cost of the same is deemed to be included in the quoted rates.
Supply, laying, jointing & testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade (Earthed), of size 95 Sqmm, 3 core in trenches / through GI pipe / fixed along with pole structure etc complete all as specified & as directed. Make : HAVELLS/GLOSTER/POLYCAB. Note: (i) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. (ii) Rate quoted per RM is deemed to be inclusive of provn of HT 11 KV (E) cable route indicators at an internal of every 50RM including every corners/bends. Decision of GE wrt type/size and provn/installation of subject HT cable route indicator shall be final and binding. Cable route indicator to be got approved before incorporation at site of work.
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core in trenches / through GI pipe / fixed along with pole structure etc with all fixing & connecting accessories complete all as specified & as directed. Make : HAVELLS/GLOSTER/POLYCAB. Note : Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work.
Description all as per Item Sl No - 04 here in before but of size 300 Sqmm 3.5 core complete all as specified and as directed.
S & F cable jointing kit for 11 KV (Earthed) grade cable for OUTDOOR termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 Sqmm complete all as specified and as directed. Make : DENSON/3M/YAMUNA/CABSEAL.
S & F cable jointing kit for 11 KV (Earthed) grade cable for OUTDOOR straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 Sqmm complete all as specified and as directed. Make : DENSON/3M/YAMUNA/CABSEAL.
M & L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) for transformer platform / plinth etc. & finishing the surface even & smooth using extra cement incl necessary formwork & plastering/ rendering work complete all as specified & as directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed. Make of GI Pipe : TATA/JINDAL/PRAKASH.
M & L for earthing complete with Copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed. Make of GI Pipe : TATA/JINDAL/PRAKASH
Notes for Item Nos 9 & 10 : On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.
M & L for GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 80 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. Note : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates.
M & L for cutting the existing hardstanding /PCC / WBM road at a depth of not less than 75 cm & 30 cm in width for passing of HT/LT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard/dense soil complete all as specified and as directed.
Note for Item Nos 12 & 13 : Any damages made to the existing services of MES/WCB/TNEB/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/ITRC/Signal communication cables etc. during the excavation/road cuting etc. progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-in-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding in this matter.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick with excavated soil complete all as specified and as directed.
Removing of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed.
M & L for providing sand cushioning for protection of UG cable in trenches with Coarse River Sand/ Riddled Earth of approved quality as approved in writing by GE including filling, spreading and punning down to desired thickness complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300 x 180 x 40 mm in trenches for protection of UG Cable with width equal to length of PCC cover, laid dry & flat complete all as specified & as directed. Make : Mehtab /Lucky Cement Block Works /Sukhi Enterprises.
M & L for shifting of 200 KVA Transformer from Sub-Stn No-05 to Gorkha Camp Sub-Stn or any other location under GE DSSC using Hydra/Crane/JCB etc. by disconnecting the electrical connections from existing location & making electrical/earthing connections incl commissioning of the Transformer at new location & making good the disturbed/damaged surfaces etc. complete all as specified & as directed.
M & L for shifting of 100 KVA Transformer from Gorkha Camp Sub-Stn to Sub-Stn No-05 or any other location under GE DSSC using Hydra/Crane/JCB etc. by disconnecting the electrical connections from existing location & making electrical/earthing connections incl commissioning of the Transformer at new location & making good the disturbed/damaged surfaces etc. complete all as specified & as directed.
Supply, install, testing & commissioning of gang operated device (GOD), tripple pole, current rating 400 Amps, HT 11 KV vertical, mechanically operated mounted on insulators and steel frame with operating mechanism operated from ground with and including jumper connections with suitable size & type ACSR conductor along with PVC pipe covering with colour code between main supply and GOD complete all as specified and as directed. Make : BHEL/PACTIL/JAIPURIA BROTHERS.
M & L for swing out expulsion fuse single pole (Drop Out Fuse) with fuse carrier , fuse element mounted on insulator & fitted on steel frame etc for 11000 volts of capacity 25 amps complete all as specified and as directed. Make : BHEL/PACTIL/JAIPURIA BROTHERS.
S & F lightening arrester non-linear metal oxide type, complete with all fittings, transmission/distribution class, discharge capacity 65 Kilo amps suitable for 11 KV out door type including necessary connection and fittings all as per IS-3070 Part-III and IEC 1994 including strap bolts, nuts and washers etc. complete all as specified and as directed. Make : ELPRO /OBLUM/ JAIPURIA BROS /PACTIL Note for Item Nos 20 to 22 : Channels, cross-arms, bracings, nuts, bolts, washers etc. shall be measured & paid separately under relevant items of work.
M & L for cross arms bracings supports, clamps and back plates fabricated from structural steel sections incl nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts in any shpae or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint incl preparation of surfaces complete all as specified and as directed.
S & F danger notice plate of size 25 x 20cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for HT conforming to IS-2551 complete all as specified and as directed.
LAKSHMI ELECTRICAL ENTERPRISES
Saket Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .