Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.2 L+₹48,286.36 (2.22%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.6 L+₹2.8 L (13.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹24.7 L+₹3.0 L (13.8%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹25.3 L+₹3.6 L (16.6%)Rejected-Finance H NO 411 SECTOR 4 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU | J K | 180015 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
23 Feb 2021, 6:00 pmClosed
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
REPAIR/REPLACEMENT OF JOINERY, PANELING, PATH AND INTERNAL ELECTRIFICATION AND PETTY REPAIR INTERNAL ELECTRIFICATION AT PAO LSRC UNDER GE 865 EWS AT LEH
2020_MES_402652_2
138WE/L-59/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹60,000
Yes
16 Mar 2021
2 Feb 2021
25 Feb 2021
2 Feb 2021
23 Feb 2021
9 Feb 2021
Amount
Demolition of cement concrete in ground floor and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of precast concrete block walling built in cement mortar including all quoins, arches , pillars etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (But not backing ) and removing serviceable tiles to stone and rubbish of premises, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as directed by Engr-in-charge..
S&F in repair 19 mm dia mild steel, chromium plated curtain rods with bracket, end bulbs of suitable size, complete all as specified & directed.
Dismantling wall/floor and ceiling boards (fiber, pulp, inlsulation,etc) or insulation boards/slabs/blankets, any thickness including covered fillets complete all as specified and directed.
Dismantlng framed work in wooden fillets, rails, posts, rafters, purlins, grids for ceiling & wall panelling etc under 40 Sq.cm in secton, complete all as specified and directed.
Plain fillets of 2nd class soft wood, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 & not exc 25 sq.cm, complete all as specified & directed.
Plain fillets of 2nd class soft wood, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 6 & not exc 13 sq.cm, complete all as specified & directed.
Decorative cover fillets of standard hard board, 6mm thick, 40mm wide, and fixing with screws, complete all as specified and as directed by Engineer-In-Charge.
M&L for 6mm thick (5 ply) plywood grade BWR type BB as in walling/ panelling fixed with nails to timber frame work, complete all as specified and as directed.
All as per description of item No 11.00 above but in ceiling, complete all as specified and directed.
Prelaminated particle board, 9mm thick, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with nails to timber frame work, fixed in wall panalling/ cupboard shutters and partition, complete all as specified and as directed.
Prelaminated particle board, 9mm thick, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with nails to timber frame work, in ceiling, complete all as specified and as directed.
M&L for pre cast block masonry in cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) and set in set in CM 1:6, complete all as specified and directed.
Taking down cement plaster / raised pointing on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors aprons laid bedded and pointed in any mortar, complete all as specified.
M&L for sheet glass 5.5mm thick ordinalry quality and glazing with aluminium beeds in square exc 0.50 sqm in each pane complete all as specified and as directed.
M&L for 15mm thick rendering on other than fair faces of brick works finished even and smooth (without using extra cement) in cement mortar 1:6 complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick works finished even and smooth (without using extra cement) in cement mortar 1:4 complete all as specified and as directed.
75mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed.
M&L machine pressed precast concrete interlocking paver block any shape and size polished with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickiness M-35 grade complete all as specified and as directed by Engr-in-Charge.
M&L sand filling (50 mm average thickness) under floors in foundations and for laying Interlocking paver blocks including watering and consolidation complete all as specified and as directed by Engr-in-Charge.
100 mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregates) as in path/hardstanding complete all as specified and directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in floor finishes, surface finished even and fair to receive top finish complete all as specified and directed.
Dismantling roof tiles or roof treatment of any description including cement mortar, bedding (but not backing ) and rubbish of premises complete all as specified and as directed.
Cutting out cracks to V section in existing roofs or terracing ,cleaning out ,wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed
Cutting out cracks to V section in existing roofs or terracing ,cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1, complete all as specified and as directed
Cutting grooves in concrete / wall surface ,75mm wide and 65mm deep and shaping horizontal/vertical face of groove with cement mortar 1:3 finished even and smooth all as specified.
M&L for brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified and as directed.
M&L for priming surfaces and applying heavy treatment (for severe conditions), using glass fibre base bitumen felt, grade 2 complete all as specified and as directed.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforment with polyster non woven fabric (weught not less than 150 gms/sqm) laid on primed surfaced application including removing old dameged existing roof treatment complete all as specified and as directed.
2nd class hard wood (Sal/Hollock) plain, solid, straight chowkats/frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, with one or more rebates, complete all specified.
S&F mild steel work as in hold fasts and similar work confirming to Fe-290 or Gde-E-165 complete all as specified and as directed.
M&L for treating wooden chowkats surface of any description n exc 10 cm in width or girth with black bituminus paint in two coats, complete all as specified and directed.
M&L for preparing surfaces and treating small articles of buliders hardware such as MS hold fasts , MS butt hinges etc, with two coats of synthetic enamal paint over a coat of primer when un connected with other painting or when painted in a defferent tint , complete all as specified and directed.
Material & labour PCC 1:3:6 type C-1, (using 20 mm graded crushed stone aggregate) as in hold fast , bed block and like, complete all as specified and as directed by the Engr-in-Charge.
35mm thick factory made 2nd class hardwood (Sal/Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified.
2nd class hardwood (Sal/Hollock) , glazed and skeleton shutters, 35mm thick, open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I for door shutters, complete all as specified.
S&F Galvanised mild steel wire cloth ,0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and as directed.
S&F mild steel butt hinges, medium weight cold rolled 100mm size, complete all as specified and as directed.
S&F 150mm long aluminium anodized, barrel tower bolt of extruded section, complete all as specified and as directed.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized, complete all as specified and as directed.
S&F in repair 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed.
S&F in repair 250mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed, complete all as specified and as directed
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 Sqm and not exc 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match the tiles over and including screed bed with cement mortar (1:6) 15mm thick laying floor tiles complete all as specified and directed. Shade/Colour of tile shall be approved by the GE.
M&L for Glazed ceramic coloured tiles in vertical surfaces 350 x 250 x 7mm /450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match the colour of tiles over 10mm thick cement mortar (1:4) in dado/skirting tiles complete all as specified and directed. Shade/Colour of tile shall be approved by the GE.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper including a coat of primer over 3mm thick wall care putty complete all as specified and as directed.
M&L for preperation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer(chalk whiting) complete all as specified and as directed.
M&L for preperation of new wood or wood based surface of any description over 10cm width or girth and applying two coat of synthetic enamal paint over a coat of pink primer, complete all as specified and as directed.
Taking down steel tubing 20mm bore of pipe and connections in any position including cleaning for refixing or removal to store complete all as specified and as directed .
Taking down steel tubing 25 to 32 mm bore of pipe and connections in any position including cleaning for refixing or removal to store complete all as specified and as directed .
3 layer PP-R Polypropylene random copolymer pipes 20 mm dia SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors etc complete all as specified and as directed .
3 layer PP-R Polypropylene random copolymer pipes 25 mm dia SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors etc complete all as specified and as directed .
3 layer PP-R Polypropylene random copolymer pipes 32 mm dia SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors etc complete all as specified and as directed .
Dismantling water tanks and removing to store Exc 250 and not exc 500 ltrs capacity complete all as specified and as directed .
Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe including taking down old unserviceable tank, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PUF water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity hoisted and fixed in position all as specified in SSR Part I including dismantling of existing water tanks & removing to store complete all as specified and as directed .
Taking down carefully aluminium / copper point wiring light/fan/socket or power complete including unscrewing from board fitting and fixture such as switches, sockets, ceiling roses, lamp holders, brackets, pendent holder , light fittings , regulators, distribution/ Meter boards, MCBs etc and making good the distturbed surface matching with existing specifications complete all as specified and directed.
Point wiring for one light point or fan point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, FRLS single core, multi-stranded, copper conductor cable, 1100 Volts, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed surfaces of walls and ceilings, terminated in and including rectangular PVC board for mounting fitting/ switches/ sockets and 1.50 Sqmm, copper conductor, multi-stranded, FRLS as earth continuity wire connected to earth terminal, including making good to disturbed surface as matching to existing descriptions/ specifications, complete all as specified and as directed.
Description all as per serial item No- 61.00 here-in-before but for 5 Amps 3 Pin Socket outlet on same board, complete all as specified and as directed.
Description all as per serial item No- 61.00 here-in-before but for 5 Amps 3 Pin socket outlet on independent board, complete all as specified and as directed.
Description all as per serial item No- 61.00 here-in-before but one bell point controlled by one bell push the independent board, complete all as specified and as directed.
Point wiring on independent board with 4.00 Sqmm, PVC insulated, unsheathed, FRLS single core, multi-stranded, copper conductor cable, 1100 Volts, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed surfaces of walls and ceilings, terminated in and including rectangular PVC board for mounting fitting/ switches/ sockets and 4.00 Sqmm, copper conductor, multi-stranded, FRLS as earth continuity wire connected to earth terminal, including making good to disturbed surface as matching to existing descriptions/ specifications, complete all as specified and as directed.
Taking down care fully sub main wiring of any description, complete all as specified and as directed.
Supply and Fixing lamp holder, PVC/ Polycarbonate type with back plate, complete all as specified and as directed.
Supply and Fixing 9 watt LED Bulb complete all as specified and as directed.
Supply and Fixing switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed.
Supply and Fixing switch socket outlet 5 pin, 5 Amps, 230 Volts flush type complete all as specified and as directed.
Supply and Fixing switch socket outlet multi purpose 3 pin, 5/15 Amps, 230 Volts flush type complete all as specified and as directed.
Supply and Fixing ceiling rose, surface bakelite 65 x 50 mm two or three terminals complete all as specified and directed.
Supply and Fixing of bell push single pole 230 Volt complete all as specified and as directed.
Supply and Fixing in repairs of bell ding-dong push single pole complete all as specified and as directed.
Supply and Fixing of modular switch one way 6 Amps 230 volts 1 module, complete all as specified and as directed.
S&F Switch modular switch socket combination out let 5 pin & 5 Amps, flush type universal complete all as specified and as directed.
S&F Switch modular switch socket combination out let multi purpose 3 pin & 5/15 Amps, flush type universal complete all as specified and as directed.
S&F Switch of modular white cover plate with frame 3 module suitable for 3 pin 5 Amps and 15 Amps switch sockets 230 volts complete all as specified and as directed.
S&F Switch of modular white cover plate with frame 6 module suitable for 3 pin 5 Amps and 15 Amps switch sockets 230 volts complete all as specified and as directed.
S&F Switch of metal flush box 3 module suitable for 3 pin 5 Amps and 15 Amps switch sockets 230 volts complete all as specified and as directed.
S&F Switch of metal flush box 6 module suitable for 3 pin 5 Amps and 15 Amps switch sockets 230 volts complete all as specified and as directed.
Supply and fixing in replacement Endura Slim Pro Plus 2' x 2' recess mounting warm white LED luminaries white powder coated sheet housing LED front frame with translucent cover fixed to the housing fixed in front frame 36 x 1 watt LED extruded aluminium heat sink projected in false ceiling complete all as specified and as directed .Make: Havells/ Bajaj/ Crompton
Supply and Fixing LED Light fitting including LED tube light batten type 1x20 watt, mounted on integrated sleek extruded polycarbonate LED channel with white accrylic cover suitable for 230 Volts, 50 Hz cool white colour bipin holder, connector block etc complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper concuctor cable of suitable size complete all as specified and as directed. Make Havells Cat Part No. STOUTPLUS600BS20WLED857SPCWH HSN Code 9405 or Equivalent model of Make: Crompton/ Bajaj/Philips
Supply and Fixing in replacement Round Edgepro range of slim fit low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology. An ideal solution where ceiling voids are limited but high lumen output is required of 15 Watt, complete all as specified and directed. make:- Havells/Crompton/Bajaj
LED bulk head light fitting 1 x 10 watt , 230 volts, attractive wall/ ceiling mounted any type with white reflactor complete with all accessories prewired and includeing connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make: Havells cat part No LHEOAOP7UZ6W010 or equivalent in Bajaj/ Crompton Greaves/ Philips/ Wipro/GE.
Supply and Fixing of Air Circulator any type and size with plastic body 300 mm sweep including taking down existing and making necessary arrngements of fixing and connectioning with flexible three core cable from the ceiling rose, complete all as specified and directed. make:- Usha/Crompton/Bajaj
Supply and Fixing modular AC Box with 20 Amp SP plastic enclouser abd unbreakable heavy duty with ISI plug top, complete all as specified and directed.
Supply and Fixing modular AC Box with 25 Amp SP plastic enclouser abd unbreakable heavy duty with ISI plug top, complete all as specified and directed.
Supply and fixing in replacement of LED single tube light rod only 20 Watt 4' length 220 Volts suitable to fixing existing tube light fitting surface/ pendent mounting, complete all as specified and as directed. make:- Havells/Crompton/Philips/Bajaj
Supply and Fixing of heating element suitable for water storage heater vertical type 220/240 Volt AC, 1500 watt and making connection and testing, complete all as specified and as directed.
Supply and Fixing of heavyb duty PVC connection armoured type with brass union, nut, heat resistence type rubber washer for hot water, complete all as specified and as as directed.
Supply and Fixing of thermostate switch for water storage heater suitable for Racold type 220/240 Volt, 50HZ, AC temperature range 32-88 degree centigrade, complete all as specified and as directed.
Supply and Fixing of sheet metal enclosures for distribution box for MCBs, Single pole and neutral,4 way with, 240 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
Supply and Fixing of sheet metal enclosures for distribution box for MCBs, Single pole and neutral,8 way with, 240 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
Supply and Fixing of sheet metal enclosures for distribution box for MCBs, Single pole and neutral,12 way with, 240 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
Supply and Fixing of MCB, single pole and neutral, 63 Amps, 240 Volts , 10 KA C series, complete all as specified and directed.
Supply and Fixing of MCB, single pole, 6 to 32 Amps, 240 Volts, 10 KA C series, complete all as specified and directed.
Supply and Fixing of plug top hard PVC type, 3 pin, 5 Amp, complete all as specified and directed.
Supply and Fixing of plug top hard PVC type, 3 pin, 15 Amp, complete all as specified and directed.
Sub main wiring for circuit/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of FRLS, PVC insulated copper conductor, single core cable, multi stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed on surfaces of walls/ ceilings, complete all as specified and directed. Note: two run of 4 sqmm and one run of 4 sqmm wire cable and PVC conduit pipe shall be measured and paid as one run unit.
Supply and fixing in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
Repair of DG Set. (i) Note No 1 : Spare parts required to be replaced under BOQ Ser Item Nos 103.00 to 114.00 should be of make as per manufacturer's recommendations. Details of DG Set 250 KVA for which spare parts required as under :- (a) Manufactured by : Sudhir Gen Sets Ltd. (b) Product Model : S.G.I 250 KVA (c) Engine : Cummins. (d) Alternator : Stamford (ii) Note No 2 : Tenderers are advised to visit the site befor quoting their rates.
Labour charges for servicing the DG sets including replacement only of B check kit of DG set 250 KVA, complete all as specified and as directed.
Supply distilled water for batteries, complete all as specified and as directed.
Supply and fixing battery terminals all as specified.
M&L for replacement of fuel filters complete all as specified.
M&L for replacement of Lub oil filter complete all as specified.
Supply and fixing Hose pipe suitable for 250 KVA DG Set complete all as specified.
Supply & fixing Fan belt suitable for 250 KVA DG Set complete all as specified.
Supply & filling engine oil of suitable grade for 250 KVA DG Set complete all as specified.
Supply & fixing Gas Kit set suitable for 250 KVA DG Set complete all as specified and directed.
M&L for replacement of By Pass filter complete all as specified.
M&L for replacement of Air cleaner filter complete all as specified.
M&L for replacement of Self Starter suitable for 250 KVA DG Set complete all as specified.
M&L cleaning of radiator for 250 KVA capacity DG sets by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/brezzing and Re-assembling after painting of the same complete all as directed.
Supply and fixing of ON Load Change over switch 415 Volt in sheet metal enclosure 4 Pole of capacity 400 Amps with connecting accessories complete all as specified and directed. Make: Havells Cat Part No. IHCNFE0400, L&T/Indo Asian.
Supply & topping up of best quality anti freezing, Inhabitor Corrosion (Coolant) liquid for DG Set at various capacity and locations complete all as specified and directed. Make: Castrol/Veedol/Valvoline.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanized iron wire 4.0mm dia as earth lead means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15 mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1(using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt, 15mm dia, medium grade, GI pipe as protection to earth lead and earth lead as 4.0mm dia GI wire (main earthing lead from earth electrode to test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing.
SUMEET TRADING CORPORATION
M/s. Gee Gee Enterprises
VIJAY ENTERPRISES
Mehar Enterprises
Rampal Singh Contractor
M/S MUNEER HASSAN AKHON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .