Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.6 L+₹15,939.98 (2.49%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹6.6 L+₹16,286.78 (2.54%)Rejected-Finance LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹6.9 L+₹48,180.30 (7.52%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹7.5 L+₹1.1 L (16.9%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
6 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF Memaura
AGE (I) AF Memaura
SPECIAL REPAIR TO STATION WORKSHOP BATTERY CHARGING ROOM AND MT WASHING BAY INCLUDING DRAINAGE SYSTEM AT AF STN MEMAURA
2023_MES_602226_1
8311/E8
Open Tender
Civil Works
Works
183 days
AGE (I) AF Memaura
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) AF Memaura
₹19,000
Yes
4 Aug 2023
9 Jun 2023
8 Jul 2023
9 Jun 2023
6 Jul 2023
22 Jun 2023
Amount
Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins arches pillars etc complete all specified and directed
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
M&L PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed
M&L for providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) in coping,kneelers, apex, bed plates, kerbs not provided, water troughs and like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work in cement 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed
Ditto Add or deduct for each 25mm girth or part thereof over or under 30cm
Taking down of wooden chowkats or frame with shutters (without taking off shutters from the frames) n exc 1.5 Sqm each complete all as specified and directed.
Taking down of wooden chowkats or frame with shutters (without taking off shutters from the frames) exc 1.5 Sqm & n.exe 4 Sqm each complete all as specified and directed.
Supply & Fixing pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fitting lugs, hinges, lock strike plates etc complete all as specified & directed.
M & L PCC 1:2:4 type B-0 (using 12.5mm graded agg) for hold fast,coping,pressed steel frame,benching roof kerbs etc. complete all as specified and directed.
Cutting holes exc half brick but not exc one brick in brick walls build in cement mortar or cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed
S&F facotry made PVC moulded door shutter 30mm thick (stiles) with solid particle board core laminated with 2mm thick termite proof, water proof and fire resistance moulded PVC sheet with 2,4, or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face etc complete all as specified and directed.
S & F 30mm thick "Rajshree Brand" Factory made Plain wiremesh PVC door shutter cosisting of frame made of MS Tubes of 19 guage thickness and size of 19mmx19mm for stiles and 15mmx15mm for top, lock and bottom rail. MS frame shall have a coat of metal primer of approved make and manufacturer. 19mmx19mm MS square tubes shall be covered with heat moulded plain sheet 'c' channel made from 5mm thick pvc sheet of density 600 kg/cum manufactuered by ISO-9001-2015 certified company of size 30mm thickness, 115mm width out of which 100 mm shall be flat and 15mm shall be bent in 90 degree angle on either side forming stiles, one of 90 degree bend edge is cut from stiles as well as rails to nails from inner side of door to hide wiremesh fixing steel screws. 5mm thick 140mm wide pvc sheet out of which 125mm shall be flat and 15mm shall be bent in 90 degree on inner side from top to bottom rail and 155mm wide pvc sheet out of which 125mm shall be flat and 15mm shall be bent in 90 on both side to from lock rail. An additional 5mm thick pvc strip of 20 mm width is to be stuck on exterior side of the C channel using PVC solvent cement adhesive . Panel will be of SS wire mesh of 24 guage to be fitted inside area of stiles and rails. The wire mesh of Top Bottom & lock rail is sealed with 15 mmx15mm tube with steel screw of size 13/16mm. 10mm (5mmx2 nos) thick pvc strip of 25 mm width is to be stuck and nail on both side of SS wiremesh interior at the top,bottom&lock rail. 10mm thick (5mmx2nos) thick, 20mm wide cross pvc sheet as gap insert for top rail & bottom rail door to be fitted to frame with 3 nos MS powder coated butt hinges size 100mmx25mmx2mm and 32mm long screw drilled suitable to pass through both the wall of MS tubes. other hardware should be fixed with 19mmx6mm size steel screw complete as specified and as dirction by Engr-IN-Charge.
Supply & fixing aluminium anodized barrel tower bolts 200mm long of extruded section complete all as specified and directed
Supply & fixing 300mm long ISI mark aluminium anodized sliding door bolt, plate type, stove enamelled black, with bright bolt not less than 12mm dia with including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed
Supply and fixing ISI mark aluminium handles 150mm long, cast type, anodised complete all as specified and directed
S & F powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Enginner-in-charge, Section 44mm x 47mm x 1.50mm thick, Wt. @ 0.94Kg/RM or as per site requirment complete all as specified and directed by Engineer-in-Charge.
S & F powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section 44mm x 47mm x 1.50mm thick weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. Note: Glass and other fittings material shall be measured & paid separately.
Supplying and fixing 5.5 mm thick sheet glass ordinary quality, tinted, not exceeding 0.50 Sq m in each pane fixed to aluminium frame work with necessary glazing clips/rubber packing/gasket, screws etc complete all as specified and as directed by Engineer-in-Charge.
S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed withstainless steel wire staples complete all as specified and as directed by Engineer-in-Charge.
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
S&F of Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, wal ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing aluminium anodized barrel tower bolts 100mm long of extruded section complete all as specified and directed
Supply and fixing ISI mark aluminium handles 100mm long, cast type, anodised complete all as specified and directed
M&L for oof treatment with polymeric water proofing membrane with certain specification given below as under complete all as specified and directed (a) cleaning and brooming the surface of roof. (b) M&L for 15 mm thick screed bed in CM 1:3 mixed with water proofing compound as per manufacturer instruction, laying over green concrete surfaces, finishing the surface even and smooth with out using extra cement (WPC measured separately). (c) After the concrete fully dried it shall be cleaned free from dust and shall be painted with a coat of bituminous primer @ 0.40 litre/Sqm (d) After primer, the entire roof surface shall be applied with hot blown bitumen grade 85/25 conforming to IS-702 @ 1.2 Kg/Sqm (e) Over hot bitumen, polymeric water proofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film with standard weight not less than 3Kg/Sqm shall be laid with 100mm side lap/end lap on prepared surfaces as of manufacture's technical representation with fusing the joints with blow torch application. (f) Applying a tack coat of hot blown grade 85/25 @ 0.30 Kg/Sqm
Supply only Liquid waterproofing compound complete all as specified and directed
Renewing tiles glazed in patches, area n.exc 5 Sqm including removing old tiles, preparing beds and laying or setting, jointing and pointing new tiles in required shade, colour and size matching with existing tiles complete all as specified and directed
Dismantling floor, hearth or wall tiling including, cement mortar bedding (but not backing), removing tiles from site and rubbish off the premises complete all as specified and directed.
M&L for acid resistant tiles, 10mm thick, vetreous ceramic unglazed, set, jointed and pointed in chemical resistant mortar in floors, coloured dark shade double charged and joint free (square/rectangular) polished, area of each tile not exceeding 0.36 Sqm laid over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
All as per above item No 31 above but over 10 mm thick plaster in CM 1:4 as in dado / skirting
Taking down of cement plaster of any description including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 as in ceilings, on RCC surfaces of facia to be finished even and smooth (without using extra cement) including necessar scaffolding etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work in cement 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered ceiling surfaces properly and applying 3 coats of white wash etc complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces properly and applying 3 coats of white wash etc complete all as specified and directed.
M&L for preparation of newly plastered concrete surfaces properly and applying 2 coats synthetic enamel paint (solvent based) over a coat of primer as in chajjas , facia etc including necessar scaffolding complete all as specified and directed.
M&L for preparation of old painted concrete/wall surfaces properly and applying 2 coats of synthetic enamel paint (solvent based) over a coat of primer as in chajjas, facias etc including necessar scaffolding complete all as specified and directed.
M&L for preparation of old plastered ceiling surfaces properly and applying 2 coat of white wash etc complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exe 15cm thickness (below or above ground level) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L of broken bricks for hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface etc complete all as specified and directed.
M&L for 100mm cement concrete type B1 1:2:4 (20mm graded aggregate) as in floor complete all specified and directed
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade "A" complete all specified and directed
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound complete all specified and directed
Dismantling of plain or corrugated steel sheeting, any guage, thickness, including Nanital or similar parttern roof coverings, ridge complete all as specified and directed .
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M & L for rendering 15 mm thick on fair faces of brick work in cement mortar 1:4 with mixing WPC,, finished even and smooth without using extra cement complete all as specified and directed (WPC measured separetely)
Material and labour for point wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic ISI PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / fan point controlled by one, one way switch 06 Amp including taking down carefully existing copper/aluminium point wiring such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc.
All as per serial item No 48 here-in-before one Fan/ exhaust fan point.
All as per serial item No 48 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
All as per serial item No 48 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per Serial Item No 48 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
Supply and fix switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
Supply and fix socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
Supply and fix socket outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
Supply and fix in replacement of industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix electronic ceiling fan regulator with rotary step, two module, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete all as specified & directed.
S & F Wall/surface mounted type LED light fitting batten type complete with LED 1x 20 watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable complete all as specified and as directed.
Supply and fix in replacement of LED security light fitting 20 watt, 3500 lumen, 5700K with IP 65 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as directed.
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Supply and fixing of sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 and IK 09 protection alongwith cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following: (a) Incoming MCCB, 100 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) Outgoing MCB, SP, AC, 240 volt of 06 to 32 Amp, 'c' curve, 10 KA breaking capacity - 12 Nos.
Supply and fix in replacement of sheet metal enclosure distribution board, single pole and neutral, AC, 240 volt, 4 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of MCB, TPN, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing MCB SP 6-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying capacity in the MCB DB complete with connection testing and commissioning,including providing copper lugs and thimble as required on site all as specified and directed.
S & F MCB SPN 240 volts, 'C' curve of rating 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, ISI mark medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
All as per serial item No 67 here-in-before but with 2.5 Sq mm nominal cross sectional area wire.
Taking down carefully ceiling fan/ exhaust fan of any sweep complete with all accessories, dismantling blades and kept in safe custody including painting complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and hanging and connecting up with provn of 3 core copper flexible cable of size 1.5 Sq mm from ceiling rose to fan complete all as specified & directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Supply anf Fix Ceiling Fans, complete with three blade, down rod, accessories,230 v, 1200mm sweep with BEE 5 Star rated BLDC motor including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable all as specified and as directed.
M/S KAUSHIK CONSTRUCTION
NAVSURAJ CONSTRUCTION AND INFRADEVELOPERS
M/s Shri krishna Constrcutions
m/s pal associates
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .