Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-Finance | ₹16.1 L | L1 | Accepted-Finance ok |
| 2 | L2₹18.5 LAccepted-Finance | ₹18.5 L | L2 | Accepted-Finance ok |
Tender Value
₹20.6 L
EMD Value
₹41,185
Closing Date
30 Jan 2026, 3:00 pmClosed
Executive Engineer (E)
Executive Engineer (E) North West, Elect. Divn., PWD ISBT, Kashmere Gate, Delhi-110006
DTTE/BTTE/KGWP Pitampura,CFDL building Wazirpur, DA Quarters Haiderpur,DC West Rampura under North West Electrical Sub Division-II, PWD,Pitampura Police Lines,Delhi. (SHComprehensive Maintenance of D.G. Set)
2026_PWD_285485_1
173/EE(E)/NWED/PWD/2025-26
Open Tender
Electrical Works
365 days
Rohini
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹41,185
Yes
3 Feb 2026
23 Jan 2026
30 Jan 2026
23 Jan 2026
30 Jan 2026
23 Jan 2026
Routine Maintenance of following capacity D.G.Sets with AMF panels including preventive and periodical maintenance of all connected accessories of D.G.Sets and attending day to day complaints, monthly visit of electrical and mechanical service personals for A-Check, rectification of fault etc. complete as reqd. as per terms and conditions. Including Carrying out of B-Check maintenance/Servicing on Twice in year. a) 500 KVA capacity (Cumins make) - 02 Nos. installed at SSCBS , Sec - 16, Rohini
b) 125 KVA capacity (Cummins make) - 01 No. installed at Kasturba Gandhi Polytechnic, Pitampura
c) 250 KVA capacity (Cummins make) - 01 No. installed at Kasturba Gandhi Polytechnic, Pitampura
d) 125 KVA Capacity - 01 No. installed at Keshav Mahavidyalya
e) 125 KVA Capacity (Kirloskar make) - 01 No. installed at DC Office Kanjhawala
f) 125 KVA DG Set (Kirloskar make) installed at ITI Mangolpuri - 01 No.
g) 125 x 1 KVA DG Set (Cummins make) installed at Sub Registrar Office Kanjhawala- 01 No.
h) 400 KVA DG Set (Kirlosker Make) installed at CFDL Lawrence road - 01 No.
i) 62.5 KVA capacity (Kirlosker make) -01 No. installed at Keshav maha Vidyalaya
j) 79 HP capacity Diesel Engine (Kirlosker make) installed at Keshav maha Vidyalaya - 01 No.
k) 117 BHP Diesel Engine (Kirloskar make) installed at Sukhdev College Rohini, Sec - 16, Rohini - 01 No.
l) 63 KVA DG Set (Kirlosker Make) installed at DC Office Rampura - 1 No.
Supplying and replacement of following part in the existing Different KVA DG Set of i/c dismantling the old one (i/c credit or old deeply discharged batteries)and making connections ,testing etc. as required. a) Lead acid Battery 115 AH
b) Lead acid Battery 150 AH
c) Lead acid Battery 180 AH
e) 12 Volt Static Battery Charger
f) 24 Volt 10 AMP. Static Battery Charger
g) Battery Charger 24V 16 AMP
(DA quarters, Haiderpur) Annual Routine Maintenance of 625 KVA DG Set (Make: - Kirlosker, Model No. - DV12SRI) (DA Quarters Haiderpur) i/c preventive maintenance of Engine And other electrical works including AMF Panel and batteries, pipelines etc on Monthly basis visit or as and when required as per direction of Engineer in Charge and also complaint basis and As per terms and conditions attached & report submitted in JE(E) office inculding carrying out of B-checks/ Servicing on every six month (Twice in year)
Annual Routine Maintenance of 320 KVA DG Set (Make: - Kirlosker, Model No. - 6SL12TARI) (DA Quarters Haiderpur) i/c preventive maintenance of Engine And other electrical works including AMF Panel and batteries, pipelines etc on Monthly basis visit or as and when required as per direction of Engineer in Charge and also complaint basis and As per terms and conditions attached & report submitted in JE(E) office including Carrying out of B-checks/ Servicing of DG Set on every six month. (Twice in year)
Overhauling of existing 79 HP Diesel Engine Pump at service centre workshop incl. dismantling and disconnection of all cables/switchgears at site, drawing out of diesel engine pump from pump room incl. the cost of loading & unloading from site and workshop with the help of chain pulley/crane & heavy labour & to and fro cartage/transportation charges from site to work shop i/c refixing and reconnection the same at site incl. testing, commissioning etc. complete as required. (Keshav Maha Vidyalaya)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx