Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15 LAccepted-AOC | L1 | Accepted-AOC low | |
| 2 | L2₹22.3 L+₹1.4 L (6.80%)Rejected-Finance | L2 | Rejected-Finance high | |
| 3 | L3₹27.4 L+₹6.5 L (31.1%)Rejected-Finance | L3 | Rejected-Finance high |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
29 Jun 2023, 1:00 pmClosed
deputy commissioner ichalkaranji municipal corpora
deputy commissioner ichalkaranji municipal corpora
SUPPLY, ERECTION AND MAINTENANCE OF IMC AIR CONDITIONING SYSTEM, DISEL GENERATOR SYSTEM, BACKUP/STORAGE SYSTEM FOR ELECTRICAL UTILITIES OF ICHALKARANJI MUNICIPAL COUNCIL for 2023-24 in IMC area.
2023_DMA_916199_2
electrical/01/2023-24
Open Tender
Electrical Works
Item Rate
365 days
Ichalkaranji
please refer attachment
2 documents required · 2 mandatory
₹590
₹15,000
2 Jul 2024
15 Jun 2023
3 Jul 2023
15 Jun 2023
29 Jun 2023
15 Jun 2023
Amount
Supplying and erecting Main Bearing Bush FOR Air Conditioning Plant
Supplying and erecting Connecting Rod Only Air Conditioning Plant
Supplying and erecting Gudgen Pin FOR Air Conditioning Plant
Supplying and erecting Gudgen Pin Bush FOR Air Conditioning Plant
Supplying and erecting Piston Only FOR Air Conditioning Plant
Supplying and erecting Cylinder line FOR Air Conditioning Plant
Supplying and erecting Delivery Valve Assembly FOR Air Conditioning Plant
Supplying and erecting Shaft Seal Assembly FOR Air Conditioning Plant
Supplying and erecting Suction Valve ring FOR Air Conditioning Plant
Supplying and erecting Suction Valve spring FOR Air Conditioning Plant
Supplying and erecting Oil Pump Assembly FOR Air Conditioning Plant
Supplying and erecting VLD Teflon FOR Air Conditioning Plant
Supplying and erecting Gasket set FOR Air Conditioning Plant
Supplying and erecting O Ring set FOR Air Conditioning Plant
Supplying and erecting Aluminum Packing set FOR Air Conditioning Plant
Supplying and erecting Oil Filter FOR Air Conditioning Plant
Supplying and erecting Crankcase Heater FOR Air Conditioning Plant
Supplying and erecting Load Unload Coil FOR Air Conditioning Plant
Supplying and erecting K-5 Valve FOR Air Conditioning Plant
Supplying and erecting Discharging Valve gasket FOR Air Conditioning Plant
Supplying and erecting Pressure Gauge FOR Air Conditioning Plant
Supplying and erecting Safety Valve FOR Air Conditioning Plant
Supplying and erecting DM-032 Driver Both side flare connection 1/4 FOR Air Conditioning Plant
Supplying and erecting Oil FOR Air Conditioning Plant
Supplying and erecting Crank Shaft FOR Air Conditioning Plant
Supplying and erecting Solenoid Coil for Pilot valve FOR Air Conditioning Plant
Supplying and erecting Expansion Valve FOR Air Conditioning Plant
Supplying and erecting Liquid Line Driver FOR Air Conditioning Plant
Supplying and erecting K-5 Valve FOR Air Conditioning Plant
Supplying and erecting Liquid Line Strainer FOR Air Conditioning Plant
Supplying and erecting Piston Ring FOR Air Conditioning Plant
Supplying and erecting Rubber Spider for Coupling FOR Air Conditioning Plant
Supplying and erecting Nitrogen Cylinder FOR Air Conditioning Plant
Supplying and erecting Miscellaneous hardware FOR Air Conditioning Plant
Supplying and erecting star delta contracter FOR Air Conditioning Plant
Supplying and erecting Decaling chemical FOR Air Conditioning Plant
Supplying and erecting Champion Gasket Sheet size 8*4*3mm FOR Air Conditioning Plant
Supplying and erecting Copper pipe 1/4 FOR Air Conditioning Plant
Supplying and erecting MP 55 Differential Pressure Switch FOR Air Conditioning Plant
Supplying and erecting MP 1 Pressure Switch FOR Air Conditioning Plant
Supplying and erecting Refrigeration Gas R22 FOR Air Conditioning Plant
Preventive maintenance includes mechanical faults finding of Decaling of condenser.
Preventive maintenance includes mechanical faults finding of External Cleaning of Evaporating Coil and servicing.
Preventive maintenance includes mechanical faults finding of Lubricating Bearing.
Preventive maintenance includes mechanical faults finding of Replacement of defective gauges.
Preventive maintenance includes mechanical faults finding of Servicing/Overhauling of compressor.
Preventive maintenance includes mechanical faults finding of Reflecting of refrigerant.
Preventive maintenance includes mechanical faults finding of Attending fault Any sudden breakdown will be attended within 48 hours...
Removing existing cooling tower and commissioning of new advance cooling tower with required modification in piping as per quotation work
Providing Manual Operation AC Plant for day-to-day Technical work (O&M) monthly (provided by considering min wages gov.regulation/G.R.)
Supplying and erecting FILLS (1200X 300 X300) (Black-Munters) FOR cooling tower Air Conditioning Plant
Supplying and erecting DRIFTS (1200 x 300 x130) FOR cooling tower Air Conditioning Plant
Supplying and erecting NOZZLES 2 1/2” FOR cooling tower Air Conditioning Plant
Supplying and erecting PVC MATERIAL FOR cooling tower Air Conditioning Plant
Supplying and erecting FRP LINING FOR cooling tower Air Conditioning Plant
Supplying and erecting M.S FABRICATION (with material) FOR cooling tower Air Conditioning Plant
Supplying and Erecting of Piston Ring Set for Disel Generator Set
Supplying and Erecting of Air Filter for Disel Generator Set
Supplying and Erecting of Bearing Conn. Rod for Disel Generator Set
Supplying and Erecting of Cylindrical liner for Disel Generator Set
Supplying and Erecting of Full packing (Upper and Lower) Set for Disel Generator Set
Supplying and Erecting of Water Filter for Disel Generator Set
Supplying and Erecting of Oil Filter for Disel Generator Set
Supplying and Erecting of Fuel Filter for Disel Generator Set
Supplying and Erecting of Fuel Water Seperator Filter for Disel Generator Set
Supplying and Erecting of Turbo Repair Kit for Disel Generator Set
Supplying and Erecting of Engine Oil for Disel Generator Set
Supplying and Erecting of Coolant 10ltr for Disel Generator Set
Supplying and Erecting of Valve Exchanger for Disel Generator Set
Supplying and Erecting of Valve Inlet for Disel Generator Set
Supplying and Erecting of Valve Seat Exchanger for Disel Generator Set
Supplying and Erecting of Guide for Disel Generator Set
Supplying and Erecting of Steam Seal for Disel Generator Set
Supplying and Erecting of Diode kit for Disel Generator Set
Supplying and Erecting of Bearing Alternator for Disel Generator Set
Supplying and Erecting of Main Bearing Set for Disel Generator Set
Supplying and Erecting of Wheel and Shaft Turbo for Disel Generator Set
Supplying and Erecting of Piston Set for Disel Generator Set
Supplying and Erecting of UV Coil for Disel Generator Set
Providing Engine Overhauling charges incl engine R/R, alternator R/R, engine to alternator alignment Fuel tank cleaning and load trial for Disel Generator Set
Providing Labour charges for fuel pump & nozzle repair & calibration for Disel Generator Set
Providing Labour charges for turbocharger for Diesel Generator Set
crane charges and transportation charges of Diesel Generator Set ( From Site to Workshop & Workshop To Site upto 30km)
starter and alternator repair charges along with spares for Disel Generator Set
main alternator dismantling, cleaning, heating and varnishing for Disel Generator Set
rewinding of 75 HP Compresser motor rewinding for AC Plant and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
7.5 HP Pump overhauling (replacement of bearing, bushing, shaft repair) for AC Plant
Providing Labour charges for cylinder head testing, repair & calibration for Disel Generator Set
Supply and Erection of 80 mm sluice valve for AC Plant
Supply and Erection of 80 mm NRV valve for AC Plant
Supply and Erection of 65 mm stop valve for AC Plant
Supply and Erection of Pressure Guage for AC Plant
On/Off emergency Push Botton (Market Rate)
Supplying ,installing , testing and commissioning tower type room AC unit of 3.5TR to 3.9TR capacity suitable to operate on 415V, 50 Hz, A.C. supply having 1 no AHU and 1 no cabinet type floor mounting type condensing unit with refrigerant R32/410A & copper condenser coil with anticorrosive fins copper condenser, hydrophilic evaporator fins powder coated outer body, with scroll/rotary compressor connected with provided refrigerant pipes, electric cables and drain pipe.
Supplying, installing, testing and commissioning tower type room AC unit of 4.0TR to 4.9TR capacity suitable to operate on 415V, 50 Hz, A.C. supply having 1 no AHU and 1 no cabinet type floor mounting type condensing unit with refrigerant R32/R410A & copper condenser coil with anticorrosive fins copper condenser, hydrophilic evaporator Fins Powder coated outer body, with scroll/rotary compressor connected with provided refrigerant pipes, electric cables and drain pipe.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz,2500 VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
Rewinding of electric motor above 7.5 H.P. upto 10 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of electric motor above 20 H.P. upto 25 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Rewinding of electric motor above 12.5 H.P. upto 15 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
Veera Electricals
AARATI ELECTRICALS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .