| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹18.2 LAccepted-AOC | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹19.7 LRejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹22.2 LRejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FORTH₹23.4 LRejected-Finance SAI VARENYA PARK VIEW FLAT NO 110 GROUND FLOOR 9TH MAIN 6TH CROSS TURAHALLI BANGALORE 560 061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | FORTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹24.7 LRejected-Finance | FIFTH | Rejected-Finance BEING NOT LOWEST |
| Sl No | Description | Qty | Unit | GKR and CO L3 | kamadhenu Electricals L5 | Pacific Enterprises L1 | PRANATHI DEVELOPERS L4 | navreet construction L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | De-scaling of Flat type collector with suitable water softening agent or by circulating mild acidic solution through the collector pipes and drain out the scaling materials from the collector all as directed and specified. | 5 | Each Job | 950 ₹4,750 | 900 ₹4,500 | 500 ₹2,500 Lowest | 1,100 ₹5,500 | 650 ₹3,250 |
| 2.00 | Maintenance & servicing of 150/200 capacity solar water heater , including material and Labour for tracing & identifying the leakage portion of insulated alluminium clading pipe line up to 25mm by cutting and taking out damaged portion , and arresting the leakage by threading and connecting short piece of same size and type of pipe (Galvanised pipe or HDPE Pipe) and insulating the same using glass wool and alluminium cladding. testing after completion of work completely all as specified and as directed. | 8 | Each Job | 1,520 ₹12,160 | 1,600 ₹12,800 | 1,000 ₹8,000 | 2,000 ₹16,000 | 600 ₹4,800 Lowest |
| 3.00 | All as per Sl item No 2 above, but , GI pipe 32 mm to 40mm size.
Note Item No 2 & 3 : The quoted rates are deemed to be inclusive of necessary accessories required for completion of work. | 5 | Each Job | 1,620 ₹8,100 | 1,800 ₹9,000 | 1,500 ₹7,500 | 2,100 ₹10,500 | 600 ₹3,000 Lowest |
| 4.00 | Dismantling/ taking out the solar street light pole with connected items complete with battery box, refixing the pole with complete accessories taken from the pole and testing and commisioning complete all as specified and as directed. | 5 | Each | 2,520 ₹12,600 | 1,800 ₹9,000 | 1,600 ₹8,000 Lowest | 2,600 ₹13,000 | 3,500 ₹17,500 |
| 5.00 | Taking down old unservicable pipes and supply and fixing Hot water pipe (GI Pipe) duly insulated with glass wool and alumimium cladding of 25mm dia complete all as specified and directed. | 40 | RM | 710 ₹28,400 | 900 ₹36,000 | 700 ₹28,000 Lowest | 800 ₹32,000 | 700 ₹28,000 Lowest |
| 6.00 | All as per Sl item No.05 above, but , 32 mm dia complete all as specified and directed. | 50 | RM | 1,150 ₹57,500 | 1,200 ₹60,000 | 800 ₹40,000 Lowest | 900 ₹45,000 | 800 ₹40,000 Lowest |
| 7.00 | All as per Sl item No.05 above, but , for 40 mm dia complete all as specified and directed. | 50 | RM | 1,250 ₹62,500 | 1,300 ₹65,000 | 500 ₹25,000 Lowest | 1,100 ₹55,000 | 800 ₹40,000 |
| 8.00 | Taking down old unservicable pipes and supply & fixing 3- layer PPR(Polypropylene random coplymer) pipes SDR 11 UV stablise and antimicrobial welding having thermal staility for hot & cold water supply including all PPR plain & brass threaded polyproplyne random fittings fixed of size 20 MM dia complete to wall/ceiling/ floor all as directed at site. | 60 | RM | 520 ₹31,200 | 700 ₹42,000 | 500 ₹30,000 | 500 ₹30,000 | 300 ₹18,000 Lowest |
| 9.00 | Taking down old unservicable pipes all as per Sl item No.8 above, but , size 25 mm dia complete all as specified and directed. | 30 | RM | 590 ₹17,700 | 750 ₹22,500 | 500 ₹15,000 | 550 ₹16,500 | 400 ₹12,000 Lowest |
| 10.00 | Taking down old unservicable pipes all as per Sl item No.8 above, but, for size 40 mm dia complete all as specified and directed. | 35 | RM | 610 ₹21,350 | 800 ₹28,000 | 600 ₹21,000 | 650 ₹22,750 | 500 ₹17,500 Lowest |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
10 Oct 2025, 6:00 pmClosed
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIRS TO SOLAR LIGHT, SOLAR HEATERS AND ALLIED WORKS AT VARIOUS LOCATIONS UNDER GE AF MARATHAHALLI
2025_MES_730817_1
8793/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹52,000
Yes
26 Dec 2025
13 Sept 2025
15 Oct 2025
13 Sept 2025
10 Oct 2025
27 Sept 2025
Amount
De-scaling of Flat type collector with suitable water softening agent or by circulating mild acidic solution through the collector pipes and drain out the scaling materials from the collector all as directed and specified.
Maintenance & servicing of 150/200 capacity solar water heater , including material and Labour for tracing & identifying the leakage portion of insulated alluminium clading pipe line up to 25mm by cutting and taking out damaged portion , and arresting the leakage by threading and connecting short piece of same size and type of pipe (Galvanised pipe or HDPE Pipe) and insulating the same using glass wool and alluminium cladding. testing after completion of work completely all as specified and as directed.
All as per Sl item No 2 above, but , GI pipe 32 mm to 40mm size. Note Item No 2 & 3 : The quoted rates are deemed to be inclusive of necessary accessories required for completion of work.
Dismantling/ taking out the solar street light pole with connected items complete with battery box, refixing the pole with complete accessories taken from the pole and testing and commisioning complete all as specified and as directed.
Taking down old unservicable pipes and supply and fixing Hot water pipe (GI Pipe) duly insulated with glass wool and alumimium cladding of 25mm dia complete all as specified and directed.
All as per Sl item No.05 above, but , 32 mm dia complete all as specified and directed.
All as per Sl item No.05 above, but , for 40 mm dia complete all as specified and directed.
Taking down old unservicable pipes and supply & fixing 3- layer PPR(Polypropylene random coplymer) pipes SDR 11 UV stablise and antimicrobial welding having thermal staility for hot & cold water supply including all PPR plain & brass threaded polyproplyne random fittings fixed of size 20 MM dia complete to wall/ceiling/ floor all as directed at site.
Taking down old unservicable pipes all as per Sl item No.8 above, but , size 25 mm dia complete all as specified and directed.
Taking down old unservicable pipes all as per Sl item No.8 above, but, for size 40 mm dia complete all as specified and directed.
Taking down , Supply in repair stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm?92gms)complete all as specified and directed.
Disconnecting existing tanks of capacity 250 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed.
Taking down ,Supply and fix in repair ball Valves high pressure of PTMT 20mm dia with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed, all as specified and as directed at site complete all as specified and directed.
Taking down ,Supply and fix Ball Valves high pressure of PTMT 25mm dia with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed, all as specified and as directed at site complete all as specified and directed.
M&L for Painting, welding and repairing of steel structures of Solar Water Heating System complete all as specified and directed.
Repair /servicing of outdoor type LED solar street light fitting any watts removing the electrical connection and taking out the integrated driver, charge controller any Volts and Amp , operating DC voltage 12 to 24 V , complete with solar panel ,batteries, cleaning with water to eliminate dirt from the surface of the solar PV module, complete all as specified and directed. Note : Material shall be measured and paid separately under relevant item of this schedule
Supply only for outdoor type LED solar street light fitting of 12 watts comprising of integrated driver, charge controller 12V /5A , operating DC voltage 12V , enclosed with Aluminium die cast hsg, with IP-65 protection complete all as specified and directed.
Supply only in repairs solar MPPT charge controller 12V, 10 Amps complete all as specified and directed.
Supply only in repairs solar MPPT charge controller 12/ 24V, 20 Amps complete all as specified and directed.
Supply and fix in repairs 12V, 75AH ,SMF Battery complete all as specified and directed.
Supply and fix in repairs 12V, 100AH ,SMF Battery complete all as specified and directed.
Supply and fix in repair solar PV panel 12 volt/125 Wp complete all as specified and directed.
Supply and fix in repair solar PV panel 12 volt/75 Wp complete all as specified and directed.
Taking down unserviceable flexible wire and Supply material and labour for PVC insulated sheathed copper conductor flexible cable of size 2.5 sqmm,Two core including making connections from solar panel to battery , with suitable lugs , bolts ,nuts and to solar light fitting complete all as specified and directed.
Top up the distilled water to the battery and cleaning the battery terminal applying petroleum jelly complete all as specified and directed.
Dismantling the solar hot water storage tank, stop the leakage of container by welding/Brassing carefully without damaging the inner parts and refixing the same after painting the existing colour complete all as specified and directed.
Taking down ,Supply and fixng in repair heating element suitable to existing model and make 2 KW Dual clip type/tri angle type / round type with rubber gasket suitable for solar water 100 ltr to 200 ltr LPD complete all as specified and directed. Make: Theeta /Elteck or equivalent
Taking down ,Supply and fixng in repair heating element suitable to existing model and make 3 KW Dual clip type/tri angle type / round type with rubber gasket suitable for solar water 200 ltr LPD complete all as specified and directed. Make: Theeta /Elteck or equivalent
Taking out the unserviceable HPSV /CFL street light fitting any watts , Supply and fixing 1x60 W LED street light fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection complete all as specified and directed.
Taking down battery box supply and fix metal battery box for existing size gauage with door opening on top side with locking arrangements with two coats of enamal paint with existing colour complete all as specified and directed.
Taking down ,Supply,Fixing ,Testing & Commissioning Smart ,Solar LED street light (All in One)(24 W)with following specifications Battery Lithium ion of capacity 28.6AH 11.1 V ,Autonomy 42 Hrs ,LED 48 ,pole height 8 mtrs ,solar charging time 5-6 hrs ,Lighting time 24 hrs ,Body fibre reinforced plastic,Protection IP 65,Sensor PIR motion ,Work temperature -10 degree celsuis to +55 degree celsius ,Light Source W-LED ,Cplour temperature 5500-6500 K,Light Output 180 lm/watt ,Duty cycle dusk to dawn,PV Module (Wp)under STC 55 Wp,PV module chemistry -monocrystalline ,PV module efficiency 17 %, etc complete all as specified an as directed by EIC
Taking down electrical chimney supply fixing electrical chimney of width 90 cm suitable for 4 to 5 burners ,1500 CMH ,filterless facility alongwith autoclean facility (uses water to auto clean the collection chamber )complete all as specified and as directed by Engr-in-Charge.
Taking down , Supply and fix electric water heater,storage type ABS body with SS inner tank and heating element upto2 KW capacity 25 litre, BEE 5 Starrated complete with all accessoriessuch as safety valve, thermostate,NRV, connection piece etc.
Taking down ,Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of 250 mm sweep complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
Supply ,Fixing,Installation,testing & commissioning of RO water purifier Kent 8 L RO +UV+UF+TDS suitable for all borewell water,tanker,muncipality water with accessoriees complete all as specified and as directed by EIC .Make :Kent
Taking down ,Supply & fix Water dispenser with 3.2 storage capacity ,with heating cooling,normal function,ABS plastic material ,power requirement AC 230V,50 Hz with hot water storage capacity 0.9 Ltr complete all as specified and as directed with Engineer in Charge .
Taking down , Supply Installation ,testing & commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. Make- VINITEC/V GUARD/VOLINA
Taking down , Supply & Fix automatic swing gate operator full kit roller type-DC motor with 2 remote manual key autolocking system with stoppers for gates compete all as specified and as directed by EIC
Taking down ,S&F inverter emergency LED batten 20 W which provides the uninterrupted back up of upto 3hrs during power cut,with guarantee of more lumens with 4 KV surge protection to keep the product safe in any condition ,color temperature 6500 K,brightness 2000 Lm connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells/Orient
Taking down , Supply and fix bldc motor ceiling fan 5 star rating 1200 mm sweep remote control 100 percent copper white colour compete all as specified and as directed by EIC Make : Havells/Orient /CG
Disconnection and removing, Supply Controller Kit Set Consist of :- a). Single Channel Controller - 01, b). 7 Ah SMF Battery - 01, c). Sukam Surge Protector - 01, d). Fence Live Indicator - Flashes for every pulse ,high visibility upto 1 KM ,Water & UV resistant - 01,e). Super Earth Kit - Earth Kit must comprise of non rusting 304grade stainless steel rod inserted in moisture absorbant chemical mixture. The earth kit must weigh min 4kg and must be of 4ft length.T he fastening assembly must be hot dip galvanized and made of stainless steel. - 03 f). External horn - Alaram device operating at 12V having audibility of 90db level,alaram must turn ON automatically at CMS when fence is damaged or voltage on the fence is <3KV - 01,g). Battery 65 AH (AMF) - 12V SMF for use as external power source for fence controller & accessories - 01 h). Solar PV Module 37W with charge regulator , stand and pipe-01- 01
Disconnection and removing ,Supply Intermediate Post kit set - 1.2m, 12 lines-140 Nos, Each Intermediate Kitset consists of below :- a).1.2m + 0.3m grouting - Intermediate post T Profile 25x25x3mm - 01, b). Intermediate T post Insulators-12 Nos
Disconnection and removing, Supply End post kit set - 1.2m, 12 lines Each End Post Kitset consists of below :- a). Main Pipe - 2mm thickness- 40NB HDG to 60 microns - 1.2m height-01 Nos,b). Support Pipe -2mm thickness - 25NB HDG to 60 microns - 01 Nos ,c) Spl End Strain hooks with HDG of 30 microns,d). Spl End Strain hooks with HDG of 30 microns - 12 Nos,e).End Insulator made of virgin polycarbonate material UV resistant and with stand a BD of 15KV-12 Nos,f). Spin galvanized joint clamps - The joint clamps must be of spin galvanized MS material. The fastener must facilitate firm connection of fence strand size upto 4mm (3/16'' 8auage) - 12 Nos,g). Link - Link must be made of galvanized wire and must facilitate looping fence strand connection for completing the configuration in each section and zone.-06 Nos
Disconnection & Removing ,Supply corner post kitset. Each Corner Post Kitset Consists of below:- a). Main Pipe - 2mm thickness - 40NB HDG to 60 microns - 1.2m height - 01 No b).Support Pipe -2mm thickness - 25NB HDG to 60 microns - 02 Nos,c). Spl End Strain hooks with HDG of 30 microns - 12 Nos, d). End Insulator made of virgin polycarbonate material UV resistant and with stand a BD of 15KV - 24 Nos,e). Spin galvanized joint clamps - The joint clamps must be of spin galvanized MS material. The fastener must facilitate firm connection of fence strand size upto 4mm (3/16'' 8auage ) - 24 Nos,f). Link - Link must be made of galvanized wire and must facilitate looping fence strand connection for completing the configuration in each section and zone - 12 Nos
Disconnection and removing,Supply and fixing of Permanent wire tightner-wire tightners are of LM6 grade aluminium alloy .They must facilitate tensioning of fence strands in both directions and must have firm locking mechanism.
Disconnection and removing,Supply and fixingSuper earth kit earth kit must comprise of non rusting 304 grade stainless steel rod inseted in moisture .The earth kit must weight min 4 kg and must be of 4 ft length .The fastening assembly must be hot dip galvanized and made of stainless stee l.
Disconnection and removing,Supply and fixing Warning sign boards -warning sign board must be in bright yellow colour and must have legible information in both sign language .It must be installed on the fence lines suitable height for visibility .Warning sign boards must be printed in hindi ,english and kannad directions .
Disconnection and removing,Supply and fixing Corflute sign board -corflute sign board must have legible information in both sign and languages.It must b einstalled on the fence lines suitavble height for visibility ,corflute sign board is installed every 100 mtrs on the perimeter .
Disconnection and removing,Supply and fixing High tensile 2.59 mm galvanised wire in kgs.
Disconnection and removing,Supply and fixing Double inserted cable should be made of two layers of installation ,outer insulation should be abrasion resistant HDPE and inner insulation made of polypropelene .The core should be 13 g wire .
Disconnection and removing,Supply and fixing HDPE Pipe 20 mm ISI brand.
Disconnection and removing,Supply and fixing Lightening divertor-capable of diverting stray lighting from fence to earth shall have the provision for adjusting spark gap .
Disconnection and removing,Supply and fixing Joint clamps for earth kit ,warning sign board ,corflute sign board-the sign board -The joint clamps mut be of spin galvanised MS material .The fastener must facilitate firm connection of fence strand size upto 4 mm (3/16 "gauge )
Taking down Supply intallation,testting and commissioning of HP laserjet tank MFP 2606dn mutifunction monochrome laser printer (Toner cartridge ) with print copy scan feature along with supporting of supported OS,macOS,ios,Linux,windows for complaint detailing at power house complete all as specifed and as directed by EIC.
Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sq.mm, 4 core including taking down existing cable complete all as specified. NOTE : Excavation & Earthwork, Sand Cushioning & Cable protecction shall be measured & paid seperatly
Taking down Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sq.mm, 4 core including taking down existing cable complete all as specified. NOTE : Excavation & Earthwork, Sand Cushioning & Cable protecction shall be measured & paid seperatly.
Taking down Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sq.mm, 2 core including taking down existing cable complete all as specified. NOTE : Excavation & Earthwork, Sand Cushioning & Cable protecction shall be measured & paid seperatly
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, not exceeding 10 sq m on plan and getting out in soft/loose soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils.
Removal of surplus soil to a distance not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Taking down S&F 50 mm bore GI tubing light grade including necessary fittings such as bend, tee, elbow etc complete in trenches/ on wall complete all as specified.
Taking down Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250 x 150 x 40 mm for cable protection
Supply and spreading fine river sand in trenches for cushioning of under ground cable all as directed by Engr-in-Charge at site Note:- Only punned thickness 18 cm will be measured and paid.(NOTE: Punned thickness shall be measured & paid)
navreet construction (BID ID -3441558)
GKR and CO (BID ID -3437644)
PRANATHI DEVELOPERS (BID ID -3439007)
kamadhenu Electricals (BID ID -3441135)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .