| 1 | L1₹3.5 CrAdmitted-Finance | ₹3.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.0 Cr+₹1.5 Cr (42.5%)Admitted-Finance | ₹5.0 Cr+₹1.5 Cr (42.5%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Work Exp. / Completion Certificate and Turnover not as per Tender Specification. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Work Exp. / Completion Certificate and Turnover not as per Tender Specification. |
| 5 | Rejected-Technical | - | - | Rejected-Technical G.S.T. Cancelled, Work Exp. / Completion Certificate and Turnover not as per Tender Specification. |
| Sl No | Description | Qty | Unit | KHAN ENTERPRISES L2 | GANGA ELECTRICALS L1 |
|---|---|---|---|---|---|
| 0.00(Part-A) Supply of Materials as per RESSPO Technical Specification & Drawing. (Technical Specification & Drawing attached for materials not available in RESSPO) | |||||
| 1.00 | Steel Tubuler Pole 11 Mtr Long SP 55. | 271 | No. | 54,20,000 ₹63,95,600 | 40,64,729 ₹47,96,380.22 Lowest |
| 2.00 | Steel Tubuler Pole 9 Mtr Long SP 33. | 115 | No. | 16,10,000 ₹18,99,800 | 13,33,885 ₹15,73,984.3 Lowest |
| 3.00 | Mild Steel (MS) Earthing Complete | 326 | No. | 3,26,000 ₹3,84,680 | 1,62,674 ₹1,91,955.32 Lowest |
| 4.00 | 11 KV XLPE Alluminium Cable size 3x120 sq mm | 17,450 | Mtr. | 1,43,09,000 ₹1,68,84,620 | 1,31,04,775.5 ₹1,54,63,635.09 Lowest |
| 5.00 | 11 KV VCB for O/G CTR 400/200/5 A 350MVA | 3 | No. | 15,00,000 ₹17,70,000 | 11,99,997 ₹14,15,996.46 Lowest |
| 6.00 | 11 KV VCB for O/G CTR 200/100/5 A 250MVA | 1 | No. | 5,00,000 ₹5,90,000 | 3,50,999 ₹4,14,178.82 Lowest |
| 7.00 | Top Channel 125x65x2240 mm | 52 | No. | 1,04,000 ₹1,22,720 Lowest | 1,35,148 ₹1,59,474.64 |
| 8.00 | Dropper Channel (Technical Specification & Drawing attached) | 59 | No. | 1,77,000 ₹2,08,860 | 94,341 ₹1,11,322.38 Lowest |
| 9.00 | Heat Shrinkable 11 KV Outdoor Cable Jointing Kit for 3x120 sq mm. XLPE cable Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI STD. 09-13 and all other relevant standards complete with all accessories. | 93 | No. | 2,79,000 ₹3,29,220 | 1,20,807 ₹1,42,552.26 Lowest |
Tender Value
₹4.1 Cr
EMD Value
₹8.2 L
Closing Date
16 Aug 2022, 2:00 pmClosed
Superintending Engineer
E.U.D.C.-1, 57, George Town, Prayagraj
Mahewa Ghat, Shastri Bridge and Mavaiya Nala, Arail and Sewage Treatment Plant at Chhatnag Uparhar and Ganjiya Jahagirabad, Arail on Turn-Key Basis
2022_PVVNV_716274_3
22/SE/EUDC-I-Pra/2022-23
Open Tender
Electrical Works
Turn-key
75 days
E.U.C.D.-I
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
Yes
Account Number 0012002100504911
₹8.2 L
Yes
20 Aug 2022
8 Aug 2022
16 Aug 2022
8 Aug 2022
16 Aug 2022
8 Aug 2022
(Part-A) Supply of Materials as per RESSPO Technical Specification & Drawing. (Technical Specification & Drawing attached for materials not available in RESSPO)
Steel Tubuler Pole 11 Mtr Long SP 55.
Steel Tubuler Pole 9 Mtr Long SP 33.
Mild Steel (MS) Earthing Complete
11 KV XLPE Alluminium Cable size 3x120 sq mm
11 KV VCB for O/G CTR 400/200/5 A 350MVA
11 KV VCB for O/G CTR 200/100/5 A 250MVA
Top Channel 125x65x2240 mm
Dropper Channel (Technical Specification & Drawing attached)
Heat Shrinkable 11 KV Outdoor Cable Jointing Kit for 3x120 sq mm. XLPE cable Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI STD. 09-13 and all other relevant standards complete with all accessories.
Heat Shrinkable 11 KV Outdoor Cable Jointing Kit for 3x70 sq mm XLPE cable Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI STD. 09-13 and all other relevant standards complete with all accessories.
Heat Shrinkable 11 KV Indoor Cable Jointing Kit for 3x70 sq mm XLPE cable Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI STD. 09-13 and all other relevant standards complete with all accessories.
Heat Shrinkable 11 KV Straight Thourgh Cable Jointing Kit for 3x120 sqmm XLPE cable Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI STD. 09-13 and all other relevant standards complete with all accessories.
Stay Set Complete
Stay Wire (7/10 SWG)
Service Clamp for STP
Clamp for MS channel
M.S. Nut & Bolts of size 5/8" x 6" Half threaded with washer, suitable for 100x115 mm Insulator.
G.I. Pipe dia 5 Inch, Length 20 ft. (Technical Specification & Drawing attached)
G.I. Pipe 6”dia Galvanized Mild steel ‘B’ class continuous welded tubes manufactured by high class frequency indication welded process as per ISI mark screwed on both side and pipe threaded one and fitted with socket in Standard cut length of 6 meter, 5 mm. (Technical Specification & Drawing attached).
Stone Pad
Alluminium Paint (Technical Specification attached)
Red Oxide Paint (Technical Specification attached)
Danger Board (Technical Specification & Drawing attached).
Barbed wire (Technical Specification & Drawing attached)
LT Cross Arm 18 inch
11 KV Pin Insulator
11 KV Pin with nut
11 KV Disc. Insulator (45 KN)
11 KV Disc. Fitting (45 KN)
MS Angle 75x75x6x2028 mm
Top Channel 100x50x2240 mm
MS Channel 100x50x6x2250 mm
G.I. Strip size 50x6 mm complying with the requirements of IS:1897-2008: Copper strips for Electrical purposes, or latest amendments (if Any) (Technical Specification attached).
140 mm HDPE pipe as per IS 49841 (Length 6 mtr.) (Technical Specification attached).
HDPE Cable support Clamp
Aluminium Binding wire 10 SWG made of best quality Aluminium as per IS 739:1992. (Reaffirmed 2001)
11 KV Triple Pole Manually Operated (TPMO) Switch.
11 KV Drop Out Fuse set.
Sub Station Base Angle
33 KV Bus Isolator
Structure for 33 KV Isolator
33 KV Post Insulator & Lightning Arrester (L.A.)
Structure for 33 KV Post Insulator & Lightning Arrester L.A.
90 lbs Rail pieces for Power T/F 44.64 Kg/mtr.
33 KV VCB alongwith structure complete 200/100/5 A (1 No. Control panel I/C for 33 KV Single T/F, 3 No. C.T. 200/100/5 Amp. , 1 No. C.T. Structure & 1 No. 33 KV VCB Structure)
ACSR DOG Conductor
33 KV 3x300 sqmm XLPE Cable.
Heat Shrinkable 33 KV 3x300 sqmm outdoor cable jointing kit. Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI Std. 09-13 and all other relevant standards complete with all accessories.
Cable supporting structure for 33 KV XLPE cable.
11 KV 3x300 sqmm XLPE cable
Heat Shrinkable 11 KV 3x300 sqmm outdoor cable jointing kit. Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI STD. 09-13 and all other relevant standards complete with all accessories.
Heat Shrinkable 11 KV 3x300 sqmm indoor cable jointing kit. Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI STD. 09-13 and all other relevant standards complete with all accessories.
Copper Control cable 4x2.5sqmm
Copper Control cable 2x2.5sqmm
Earth Mat (for 33/11 KV S/S outdoor equipment)
Chemical pipe earthing as an additional earthing for Power T/F, L.A., C.T.
11 KV 3x185 sq mm XLPE cable
11 KV Disc. Insulator (70 KN)
11 KV Disc. Fitting (70 KN)
11 KV Cross Arm
Galvanised Iron (G.I.) Wire (6 SWG)
Heat Shrinkable 11 KV 3x185 sqmm outdoor cable jointing kit Conforming to VDE-0278/1EEE-48-1975/IS–13573-1992 and ESI STD. 09-13 and all other relevant standards complete with all accessories.
Cross Arm Holding Clamp
F-Bracket (Technical Specification & Drawing attached)
Round Clamp for STP (Technical Specification & Drawing attached)
T-Off Channel 100x50x6x1300 mm
Parallel Grooved (P.G.) Clamp made of good quality of Alluminuim Alloy suitable for Dog to Dog Conductor along with 3 Nos Nuts & Bolts.
Cable supporting angle 50x50x2020x6 mm
Angle for cable hanging 50x50x6x300 mm
11 KV XLPE Alluminium Cable size 3x70 sq mm
(Part-B) MOUNTING, FITTING & ERECTION OF WORK AS PER RESSPO NORM.
Carriage,Loading,Unloading,Installation & commissioning of new 33/11 kv 5 MVA T/F (with Oil) at 33/11 KV Arail S/S alongwith all HT connections properly Complete in all respect.(5 MVA T/F alongwith accesories will be provided by the Department).(Carriage will be done from Store Centre Naini, Prayagraj to 33/11 KV Arail Substation).
Erection And commissioning with all respect of the following line material at Arail sub-station.
33 KV lighting arrester with structure
33 KV Bus/Line isolater with structure
33 KV VCB complete with CT
33 KV Post Insulator with structure
Construction of T/F plinth of size 3x3x1 mtr on a padding 0.75 deep in the ground in the ratio 1:2:3 cement, sand and brick ballast on the top of padding brick work of Ist class bricks of 0.95m height and 0.35 meter thick wall will be constructed. Rest wall should be 0.23 mtr thickness, brick work will be in ratio 1:4 cement and sand. In the hollow portion the sand should be filled from ground level upto 15 cm below from the top of plinth, cement, sand and ballast should be placed in ration 1:24 and 2 No. Rail Pole Pieces be grouted in the concrete. The T/F plinth should be plastered on all sides by 12 mm thick in 1:6 cement and mortar.
Erection and grouting of 11kv cable support gentry with fabrication of MS channel.
Erection and grouting of 33kv cable support gentry with fabrication of MS Channel.
Erection and grouting of netural support gentry with fabrication of MS channel.
Special earthing of 5 mva power transformer neutral/body by 03 no g.i pipe and 20 feet deep to make delta point and connect with 50x8 mm GI strip.
Special earthing of LA. 03 no g.i pipe and 20 feet Long to make erthing and connect with 50x8 mm GI strip.
Making Proper connection through Copper Control cable (4x2.5 sqmm and 2x2.5 sqmm from transformer, 33kv VCB, 33kv CT to 33 kv double T/f control panel and all 11 KV VCB Switchgear.
Mat Earthing of newly constructed structure in switchyard at Arail Sub Station (GI Strip size 50x6 sqmm.)
Erection of S.T.P. complete with its all accessories at the requirement of site condition.
9 Mtr. Long STP
11 Mtr. Long STP
Grouting of ST pole 9/11 meter, Grouting in ratio 1:4:8, Cement, Stone Grit & Coarse Sand.
9 Mtr. Long S.T.P.
11 Mtr. Long S.T.P.
Erection, grouting, plinthing & earthing of 11 Mtr. long D/P at working site for cable hosting including fixing of all necessary clamps, other accessories like Top channel and its grouting in ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr. with cement, coarse sand & brick blast in ratio 1:4:8 and 12 mm thick plastring around the plinth in ratio 1:2:4 with 12 mm thickness curing of plinth should be done properly for 11 KV line.
Earthing of ST pole 9/11 Mtr.
Painting of ST pole 9/11 Mtr with the help of one coated red oxide & alluminium paint.
Laying, Proper Connection in all respect and hoisting of 33kv 3x300 sq. mm XLPE cable from 33kv bus to bus isolator.
Fixing H.S. type 33 KV 3X300 sqmm O/D, Cable Joints & End Terminations.
Hanging of XLPE 3X120/3X185/3x70 sq mm existing & Newly Constructed 9/11 Mtr. Long STP/ Rail pole with the help of Turn-buckle & stay wire at each pole.
Errection of 11 mtr S.T.P. for 11 kv overhead line complete with its all accessories at the requirement of site condition.
Stringing of ACSR Dog conductor for 11 kv overhead line.
Fixing H.S. type 11 KV 3X70/3X120/3X185 sq mm S/T cable joints & end terminations.
11 kv 3x70 sqmm S/T
11 kv 3x120 sqmm S/T
11 kv 3x185 sqmm S/T
Fixing H.S. type 11 KV 3X70/3X120/3X185 sqmm O/D, I/D cable joints & end terminations.
11 kv 3x70 sqmm outdoor box
11 kv 3x120 sqmm outdoor box
11 kv 3x185 sqmm outdoor box
Hoisting of 11 KV 11 KV 3X70/3X120/3X185 sq mm XLPE cable by providing GI pipe of size 6” dia 3 M long on single pole support including its jumpering, complete with clamps, nut & bolts.
Installation & commissioning of 11 kv TPMO & DO fuse set. On Already erected DP.
Installation, Testing , Commissioning & Earthing with g.i. strip(50x6 sqmm) of 11 KV VCB (O/G 200/100/5A) & 11 KV VCB (D/G 400/200/5) in all respect of related Sub-Station.
Trimming of Tree Branches.
Laying of 11 kV 3x70/3x120/3x185 sq. mm XLPE cable in by digging of trench 1050 mm deep, 750 mm wide including supply of required material, Ist class bricks, stone pad. The cable shall be laid between two continuous row of bricks River sand packing on all side of cables shall be done. The stone slab shall be laid on top of rows of the bricks parallel to the ground in such manner so that channels is formed covered in either direction.
Laying of 11 KV 3x70/3x120/3x185 sq mm XLPE cable by HDD Machine Drill method after braking of footpath/road. The cable shall be laid below the depth of 1050 mm from the surface of road.
Erection & grouting of stay Rod with Cement, Sand and Bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nozzling.
Restoration Charges
Road Restoration
Telephone, Sewer Line etc.
LT/HT Line
KHAN ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .