Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹9.8 L
EMD Value
₹19,520
Closing Date
4 Mar 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER-ELE.
UDA Office Udaipur
Repair and Maintenance Work of Street Light, Electrical Maintance Work at Khelgeon. (ARC) 8104
2026_UITUD_538350_1
NIT_81_04
Open Tender
Electrical Works
Percentage
365 days
Udaipur
Please Refer Tender Document
2 documents required · 2 mandatory
₹590
Refer Tender Document
₹19,520
Yes
13 Feb 2026
13 Feb 2026
5 Mar 2026
13 Feb 2026
4 Mar 2026
13 Feb 2026
Item Code [Highmast Light Maintance-]:Item Type [Electrical] ::All in all comprehensive operation and maintenanceof existing high mast lights(LED/sodium) including watch and ward (Contractor has to keep the lighting system in perfect working condition by repairing/replacement of Main control panel, feeder panel,fuse box, timer, contractor, MCCB, front handle operator switch, MCB, Isolator, Igniter, blast, SPD,driver, bulb, LED, various size cables, CRCA sheetetc. by material given in Bsr-2023. BSR as per direction of Engineer Incharge, Complete Rate.
Item Code [Led Street Light Maintanc]:Item Type [Electrical] ::All in all comprehensive operation and maintenance of existing street/road lights(LED/sodium) including watch and ward (Contractor has to keep the lighting system in perfect working condition by repairing /replacement of Main control panel, feeder panel, fuse box, timer, contractor, MCCB, front handle operator switch, MCB, Isolator, Igniter, blast,SPD, driver, bulb, LED, various size cables, CRCA sheet etc. by material given in BSR-2022.BSR as per direction of Engineer In-charge, Complete Rate.
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Item Code [11.2-2022]:Item Type [Electrical] :: Sub Item Code [11.2-2022 + 11.2.4.3]: Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 16.0 Sq. mm 4 Core
Item Code [25.9]:Item Type [Electrical] :: Sub Item Code [25.9 + 25.9.3]: Providing experienced and Highly skilled/skilled/ semi-skilled/Un Skilled labour for electric repair/ maintenance / operation of Air conditioning/Air cooling/Fire fighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as per requirement (one shift of 8 Hrs per day for 26 Working Days in a month) Semi skilled labour
Item Code [26.74-23]:Item Type [Electrical] :: Sub Item Code [26.74-23 + 26.74.4]: Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enameled wire E class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. Above 7.5 HP To 10.0 HP
Item Code [26.75-2023]:Item Type [Electrical] :: Sub Item Code [26.75-2023 + 26.75.4]: Repairing of submersible pump of with replacement of broken impellers ,diffuser, bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. Above 7.5 HP To 10.0 HP
Item Code [4.1-2022]:Item Type [Electrical] ::Sub Item Code [4.1-2022 + 4.1.2]: Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 1.5 sq.mm
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
Conditions_04.pdf
Tender Documents • 16.44 MB
BOQ_959495.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .