Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10 LAccepted-Finance 10 10 K S ROY ROAD 10 KIRAN SHANKAR ROY ROAD DALHOUSIE KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-Finance Quoting Lowest Rate | |
| 2 | L2₹13 L+₹3 L (30.0%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹13.0 L+₹3.0 L (30.2%)Rejected-Finance | L3 | Rejected-Finance Quoting Higher Rate |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
3 Jan 2024, 3:00 pmClosed
Superintending Engineer,Western El.Circle,PWD
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Electrical Installation and allied works for the construction and foundation for judicial Officers at Asansol .SITC of Passenger Lifts at 4 storied type-II quarters.
2023_WBPWD_625771_1
WBPWD/SEWEC /AED /NIQ-129/2023-24-2nd Call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Asansol
Please refer Tender documents.
5 documents required · 5 mandatory
₹28,000
Office of the Superintending Engineer, Western Ele
24 Jan 2024
18 Dec 2023
5 Jan 2024
18 Dec 2023
3 Jan 2024
21 Dec 2023
18 Dec 2023 - 20 Dec 2023
20 Dec 2023
Amount
SITC of 6 Passenger Lift (Simplex System operation) with MRL, Gearless Machine, Stainless steel body with VVVF Control Panel with ARD (with Exide maintenance free Battery) and the main following spec. Make :Category 1 : Make : OTIS / KONE / SCHINDLERs Category 2 : Make : Electromec / LT Elevator/United Elevator /Escon / Thyssen Krupp /Bharat Elevator Co. Ltd/ Engineers Vertical Services/Escon/Mukherjee Service Agency/ Johnson / Other makes those have credential in Govt. Sector. (i) Capacity-406 Kg (6 Passenger). (ii) Speed-1.00m/s. (iii) No. of stops/openings : 4 stops/ 4 opening ( all openings on the same side)
(iv) Travel height(Rise) - 12 mtrs (approx), GF to 3rd floor. (v) Power Supply-415 V±5%, 3 Phase., 50 Hz. (vi) Control system - Microprocessor based AC V3F Drive with Full collective Simplex control. (vii) Machine- Permanent Magnet AC Synchronous Motor-Eco-Disc Gearless Drive. (viii)Head room height -4500 mm.(Approx) (ix) Pit Depth-1600 mm.(Approx)
(x)Indicators(a).Full height Car operating panel with combined luminous micro stroke hall hattot with 7 segment digital hall position indicator at all landings with up & down arrow (b). Overload warning indicator in car and COP(7 Segment display). (xi) Car encloser & Panel -Stainles steel in hair line finish with false ceiling with LED downlighter & fan arrgement with rear side hand rail(18SWG). (xii) Lift Well/Hoistway available:(1500mm wide X 1500 mm deep appx.)
(xiii) Car Size (WxD) :1150 mm(depth) x 900 mm(width) & 2200 mm Height(approx.),(size should be fix by the OEM before the Installation & must be approved from EIC) (xiv) Car door - Stainless steel SS4 hairline finish two panel Telescopic auto power door (700 mm. X 2000 mm.) (xv) Landing doors Stainless steel SS4 hairline finish centre opening power door (700) mm. X 2000 mm.)
(xvi) Clear door opening (700) mm X 2000 mm). (xvii) Over Load Protection Audio & visual indication in car.The lift will not start when over load actuate and door keep open at that time and bypass the landing call when full loaded. (xviii)Door Operation: ACV3F operated automatic two panel Telescopic with Multi-Beam full height infrared detector auto power door protection system.
(xix) TRACTION MEDIA: Flat Coated Steel Belt with V groove/ Steel Rope, (xx) Fire Rated Door for 60 mins.(Rate should be quoted after inspection and verification of actual & specific site). (xxi) Emergency light & Emergency alarm - Battery operted emergency alarm and emergency light inside the car. (xxii) Intercommunication System(3Way) -By pressing the emergency alarm buttom inter cum will work and the attendent shall alarted in need.
(xxiii) Ventilation Cross Flow/standard size fan as per I.S specification. (quantity as per site requirement/OEM design) (xxiv) Car lighting:With 2/4 nos. LED down lighter as required. (xxv) False ceiling. Stainless steel hair line finish. (xxvi) Car flooring Granite Matfinish. (xxvii)Should provide Fireman Drive with switch- Fireman Switch to be provided at ground floor landing or at main lobby.
(xxviii) HALL FIXTURES: As per manufacturer design (xxix)HALL FIXTURE FACE PLATE:Stainless Steel #4(Hairline). or Touch sensitive Glass Panel or Seven segment Display. (xxx) HALL BUTTON ARRANGEMENT: As per manufacturer design). (xxxi) Auto rescue device(ARD) Battery oprated automatic rescue device for automatic evacution to the nearest floor in case of power failure. xxxii)Auto power light & Fan OFF.
SAFETY FEATURES : a) Over Speed Protection b) Single Phase Protection c) Over load Protection d) Phase Falure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Interlocking Switch h) Reverse Phase Protection i) Delocking arrangement from landing j) Thermal protection of motor Cost for all massonary & fabrication work for installation of Lift & allied accessories, patch modification, temporary or related make shift arragement regarding lift installation, minor civil work, wall/floor cutting, pocket cutting on wall and mending good the damages properly is to be included.
Term & Condition : i). The agency must procure the meterials from the OEM/ manufacturer or from their authorized sales channel, so that the standard warrenty /support of the manufacturer/OEM becomes applicable to the products to be delivered and install by them. ii). Documents that authenticates such procurement from the manufacturer/OEM or from their authorized sales channel and standard warrenty/support should be sent to the e-mail of the EIC and hard copy of it to be submitted during execution of work/submission of bill...
iii). If any refurbished meterial is supplied or installed,penal action will be taken as per existing govt. rules. *Defect liablity period 1year.
Escon Elevators Pvt. Ltd.
L. T. ELEVATOR PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .