Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹19.5 L+₹4.2 L (27.6%)Rejected-Finance H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹19.7 L+₹4.4 L (29.0%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹20.2 L+₹4.9 L (32.0%)Rejected-Finance | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | L5₹20.3 L+₹5.0 L (32.9%)Rejected-Finance 64 250 2 COD ROAD HASTINAPURI MADHU NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
14 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST AGRA
Garrison Engineer East Agra, Gwalior House, 62 Taj Road Agra Cantt
REPAIR REPLACEMENT OF LT DISTRIBUTION PANEL IN KB LINE 509 ABW WITH CONNECTED WORKS UNDER GE EAST AGRA
2021_MES_424288_1
9333/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGRA CANTT
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹50,000
Yes
5 Jul 2021
22 Feb 2021
21 Jun 2021
22 Feb 2021
14 Jun 2021
8 Mar 2021
60 days
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
–do- but depth exc 1.5 mtr but not exc 3.00 mtr
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
Laying only Sub class ‘B’ bricks old size retrieved against srl item 1 here in before laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc.
M&L for cement concrete 1:3:6 type C1 ( using 20mm graded stone aggregate ) in coping of poles studs including form work etc complete all as specified
Taking out from trenches or wall/ pole or pipe cable LT 1100 volts grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size upto 25 Sqmm , any core , for rectification of faults or replacement. Seggregating serviceable cable and unserviceable lenght by meggering or any other suitable and recommended method. Removing unserviceable from site and keeping aside serviceable for reuse at same location or any other location under AGE E/M all as rquired at site or directed. (Earth work will be measured and paid separately under respective item).
All as per Srl Item 10 here in above but of size 35 Sqmm to 95 Sqmm
Laying only in trenches or fixed to wall/pole or passing through pipe cable LT 1100 Volts grade heavy duty, armoured with aluminium conductor of any size upto 25 Sqmm any core. (Serviceable cables retrieved against srl item No 10 above will be used).
All as per Srl Item 12 here in above but of size 35 Sqmm to 95 Sqmm
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 16 Sqmm 2 cor including taking out old unserviceable LT cable complete all as specified and directed.
–do- but of size 25x 3.5 sqmm
–do- but of size 35x 3.5 sqmm
–do- but of size 50x 3.5 sqmm
–do- but of size 95x 3.5 sqmm
–do- but of size 120x 3.5 sqmm
–do- but of size 185x 3.5 sqmm
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ core with working voltage 1100 volts make: Raychem/Denson/ M Seal.
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 sqmm 3½ core with working voltage 1100 volts make: Raychem/Denson/ M Seal.
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 185 Sqmm to 300 sqmm 3½ core with working voltage 1100 volts make: Raychem/Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 Sqmm3½ core with working voltage 1100 volts make: Raychem/Denson/ M Seal.
21. M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 Sqmm3½ core with working voltage 1100 volts make:Raychem/Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 185 Sqmm to 300 Sqmm3½ core with working voltage 1100 volts make: Raychem/Denson/ M Seal.
Fixing Only cable jointing kit termination end , heat /cold shrinkable type suitable for XLPE/ PVC cables of size 95 Sqmm to 300 Sqmm3½ core with working voltage 11000 volts complete all as specified and as directed. Note : Material will be issued under Sch 'B' store.
Fixing Only cable jointing kit straight through, heat/cold shrinkable type indoor/outdoor type suitable for XLPE/ PVC cables of size 95 Sqmm to 300 Sqmm3½ core with working voltage 11000 volts complete all as specified and as directed. Note : Material will be issued under Sch 'B' store.
M&L for detucting the pin point fault of defective HT/LT UG cable 95 Sqmm to 185 Sqmm by using HT/LT megger detecting device and inculding testing using HT/LT megger to clear the fault complete all as specified and as directed.
Supplying, laying, jointing & testing 11 KV (Earthed), aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having cross sectional area 95 Sqmm 3 core includig taking out old unserviceable cable complete all as specified and directed.
Material and labour in replacement for GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
Taking down carefully aluminium conductor of any size from LT OH Lines after unbinding from insulators for replacement of multijointed / undersize conductors.
M&L for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
Restringing and restretching aluminium conductor reterived under item srl 32 above including necessary binding with insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and directed.
Restretching aluminium conductor or GI wire on existing over head lines without removing including unbinding from insulator and rebinding to insulator using aluninium binding wire , connections of incoming and out going cables, binding with spacers where required, complete all as specified. (Note ;- For measurement length of each conductor shall be taken seperately.
M&L in replacement for GI wire 4mm dia drawn straight horizontal as continuous earth wire on poles or fabrication of cradles complete all as specified and directed.
M&L in replacement for aluminium strip of any size cut to length as required at site including drilling holes, bend to shape for repairing of LT panels/GOD'S all as required or directed by Engr-in-Charge.
M&L in replacement for copper strip of any size cut to length as required at site including drilling holes, bend to shape for repairing of LT panel/ GOD switches all as required or directed by Engr-in-Charge.
M&L for shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
M&L for pin insulators 75 mm height and 90mm dia size porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
M&Lin replacement for stay assembly using GI stay rod 20mm dia complete with stay plate mild steel of size 300x300x6.00mm thick, stay bow complete all as specified and shown in Electrical Plate No 1 . (Necessary earth work, stay wire, loop insulator,clamps and PCC shall be measured and paid seperately) complete all as specified and directed.
M&L in replacement for Galvanised stay wire of size 7/4mm all as specified and directed.
M&L in replacement for loop type insulator large size porcelain vitirious of size 90 x 140 mm clearence of hole 16mm complete all as specified and directed.
M&L for steel tubular swaged pole 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm width upto 1.5 mtr above ground level, balance lenght to be painted with two coats of aluminium paint externally including taking out old steel pole complete all as specified and directed.
Supply and fixing in replacement MCCB having current ratings 63 Amps with rupturing cap 16 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make Legrand/C&S/L&T/Siemens
Supply and fixing in replacement MCCB having current ratings 100 Amps with rupturing cap 16 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make Legrand/C&S/L&T/Siemens
Supply and fixing in replacement MCCB having current ratings 160 Amps with rupturing cap 25 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make Legrand/C&S/L&T/Siemens
Supply and fixing in replacement MCCB having current ratings 250 Amps with rupturing cap 25 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make Legrand or equivalent of make /C&S/ABB/Siemens
Supply and fixing in replacement MCCB having current ratings 400 Amps with rupturing cap 36 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make or equivalent of make Legrand /C&S/ABB/Siemens
Supply and fixing in replacement MCCB having current ratings 630 Amps with rupturing cap 50 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections & all as required at site or directed by Engr-in-charge. Make or equivalent of make Legrand /C&S/ABB/Siemens
Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice. ( U/S items will be provided against respective items separately.
Removing all connections from LT panel having feeders above 04 Nos upto 08 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice. ( U/S items will be provided against respective items separately.
Supply and fix in replacement epoxy based post insulators LT 440V for mounting bus bar all as required or directed.
Supply, installation , Commissiong and Testing of feeder pillar box, Kisok outdoor type, as per IS/IEC 61439-182 tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of following : Incoming : (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip of size (50 x 6) mm. PVC sheathed with colour coding. (b) MCCB having current ratings 400 Amps with rupturing cap 36 KA , AC 415 Volts four pole with Thermal release complete with spreader links. Make Legrand or equivalent of make /C&S/L&T/Siemens- 01 No Outgoing : (a) MCCB having current ratings 250 Amps with rupturing cap 36 KA , AC 415 Volts three pole with thermal release complete with spreader links. Make Legrand or equivalent of make /C&S/L&T/Siemens- 04 No (b ) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A, Make L&T or equivalent of make Schneider or AE:-01Nos All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
Supply, installation , Commissiong and Testing of feeder pillar box, Kisok outdoor type, as per IS/IEC 61439-182 tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of following : Incoming: (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip of size (50 x 5) mm. PVC sheathed with colour coding. (b) MCCB having current ratings 630 Amps with rupturing cap 36 KA , AC 415 Volts four pole with thermal release complete with spreader links. Make Legrand or equivalent of make L&T/C&S/Siemens- 01 No Outgoing :(a) MCCB having current ratings 400 Amps with rupturing cap 36 KA , AC 415 Volts four pole thermal magnetic release complete with spreader links. Make Legrand or equivalent of make /C&S/L&T/Siemens- 02 No (b) MCCB having current ratings 250 Amps with rupturing cap 36 KA , AC 415 Volts four pole thermal magnetic release complete with spreader links. Make Legrand or equivalent of make /C&S/L&T/Siemens- 02 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A, Make L&T /Schnieder/Legrand-01 Nos All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
Disconnecting electrically, dismantling from foundation LT panel any type and removing from site.
H.S.Kochhar n Sons
MISHRA CONSTRUCTION COMPANY
8M/S TIWARI and SONS
Allied Builders
M/S RAJENDRA KUMAR AGARWAL
AUTOMATION AND SWITCHGEAR PANELS
Balaji Associates
Jain Traders
M/S LN ASSOCIATES
3Krishna Enterprises
ENVIRO TECH SERVICES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .