Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 13TH FLOOR DN18 SALTEE TECH PARK SECTOR V SALT LAKE BIDHAN NAGAR KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹91.4 L
Closing Date
5 Dec 2019, 5:30 pmClosed
CE (Procurement)
O/o CE(Procurement) Block No.3 Shakti Bhawan Jabalpur
Design, testing, supply and complete erection of Multicircuit and double circuit steel monopoles with all line materials required for modification/shifting of existing 220kV and 132kV Transmission lines due to Metro Rail Project at Indore on turnkey
2019_MPPTC_56730_1
TR-49/2019
Open Tender
Electrical Works
455 days
Any where in MP
As per Tender document
7 documents required · 7 mandatory
₹22,400
RAO MPPTCL
₹91.4 L
Yes
22.10.19
27 Jan 2020
8 Oct 2019
7 Dec 2019
9 Oct 2019
5 Dec 2019
13 Nov 2019
22 Oct 2019
Amount
Galvanised Steel Monopoles including Foundation Bolts, Anchor plate,Template, Ladders, U-Bolt, D-shackles, Hangers, Bolts/Nuts etc.
Conductor, OPGW:
ACSR Zebra
ACSR Panther equivalent ACSS Conductor
ACSR Panther
OPGW 24 fiber wire
Long Rod Polymer Insulators:
Single Suspension string for ACSR Zebra Conductor (equivalent to 13 disc of 70kN)
Double Tension string for ACSR Zebra Conductor (equivalent to 2x14 disc of 160kN)
Single suspension string for ACSR Panther Conductor (equivalent to 9 disc of 70kN)
Double tension string for ACSR Panther Conductor equivalent ACSS Conductor (equivalent to 2X10 disc of 90kN)
Single suspension string for ACSR Panther Conductor equivalent ACSS Conductor (equivalent to 9 disc of 70kN)
Double suspension string for ACSR Panther Conductor equivalent ACSS Conductor (equivalent to 2X9 disc of 70kN)
Double tension string for ACSR Panther Conductor equivalent ACSS Conductor (equivalent to 2X10 disc of 90kN)
H/W Fitting for Conductor
Single Susp.with AGS Assembly for Zebra
Double Tension for Zebra
Single Susp.with AGS Assembly for ACSR Panther equivalent ACSS Conductor
Double Susp.with AGS Assembly for ACSR Panther equivalent ACSS Conductor
Double Tension for ACSR Panther equivalent ACSS Conductor
Single Susp.with AGS Assembly for ACSR Panther
Double Tension for ACSR Panther
Accessories for Conductor
Midspan joints for Zebra
Vibration dampers for Zebra
Repair Sleeve for Zebra
Midspan joints for ACSR Panther equivalent ACSS Conductor
Vibration dampers for ACSR Panther equivalent ACSS Conductor
Repair Sleeve for ACSR Panther equivalent ACSS Conductor
H/W fittings and Accessories for OPGW:
Suspension Assembly
Tension Assembly with Joint box
Tension Assly pass through type
Down lead clamp
Vibration damper
Splice enclosure
Earth bond and PG clamp
Miscellaneous:
Enamelled Danger Boards
Enamelled Number Plates
Enamelled Phase Plates
Earthing Set for Monopole
Anti climbing devices
Total value
Total cost of Supply Schedule (8+9):
Total cost of Services Schedule (BoQ2):
Description of Work / Item(s)
Amount
Soil Investigation charges
Detail Survey
Check Survey*
Foundation work for Monopole including Excavation,base padding, reinforcement, setting of monopole, backfilling, curing and Earthing etc.
Tangent type Double Circuit Monopole (0-2° deviation angle)
Bottom Cross Arm upto 24M from GL
Bottom Cross Arm above 24M from GL
Deviation type Double Circuit Monopole (0-15° deviation angle)
Bottom Cross Arm upto 24M from GL
Bottom Cross Arm above 24M from GL
Dead End type Double Circuit Monopole (0-15° deviation angle)
Bottom Cross Arm upto 24M from GL
Bottom Cross Arm above 24M from GL
Deviation type Double Circuit Monopole (0-30° deviation angle)
Bottom Cross Arm upto 24M from GL
Bottom Cross Arm above 24M from GL
Deviation type Double Circuit Monopole (0-60° deviation angle)
Bottom Cross Arm upto 24M from GL
Bottom Cross Arm above 24M from GL
Deviation type Double Circuit Monopole (90° deviation angle)
Bottom Cross Arm upto 24M from GL
Bottom Cross Arm above 24M from GL
Deviation type Multi Circuit Monopole (0°-15° deviation angle)
Deviation type Multi Circuit Monopole (0°-60° deviation angle)
Deviation type Multi Circuit Monopole (60°-90° deviation angle)
Erection work for Monopole Anchor plate & Template, Ladders & Bolts/Nuts etc. including tightening and Punching etc.
Fixing of pole accessories like Danger Board, Number plate, Phase plate and Anticlimbing device.
Stringing of conductor & OPGW/EW including jointing & hoisting of insulator strings, armour rods dampers and other accessories and final jumpering of for complete route kM with :
On Double Ckt. Pole ; Double Strung with ACSR Panther equivalent ACSS Conductor & OPGW
On Four Ckt. Pole; Double Strung with ACSR Panther Conductor & OPGW
On Four Ckt. Pole; Double Strung with Zebra & OPGW
Dismantling:
Dismanlting of Towers
De-stringing: 220 kV/132kV MC Line
Dismanlting : DCDS line
Dismanlting 220 kV/132kV MC Line
Transportation of dismantled material
MISCELLANEOUS WORKS :
Protection of Tower footings
Excavation (for tower site leveling and revetment work).
Dry soil
Wet soil
Soft rock
Cost of concrete 1:3:6 mix required for base padding including all material including cement.
Cost of building revetment with stones with 1:5 cement mortar per Cum of stone masonry including pointing by Ration 1:3
Cost of top seal cover of revetment wall with 1:2:4 mix concrete.
Back filling and levelling of the volume enclosed by revetment walls in Cum.
Providing and fixing 100mm dia A.C. pipe for weep holes (Average length of per pipe 1.0 Meter)
Counter Poise Earthing:
Erection of counterpoise earthing including all material, excavation and back filling.
Cost of providing additional earthing at the each counterpoise wire incl.cost of material.
Provision towards Sheilding of Gas Pipe lines for protection against Erath Potential Rise
Charges for Design of Double Circuit "Mono Ploes" and their foundation, alongwith Design Vetting of all catagories of poles with foundations for construction of 132kV line in accrodance with the revised IS:802-1995 and subsequennt ammendments with factor of safety 1.5.
Charges for Design of Composite Multi Circuit "Mono Ploes" and their foundation, alongwith Design Vetting of all catagories of poles with foundations for construction of 220kV/132kV multi circuit line in accrodance with the revised IS:802-1995 and subsequennt ammendments with factor of safety 1.5.
Total value
Bajaj Electricals Limited
Unique Structures And Towers Ltd
Unique Structures And Towers Ltd
SKIPPER LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid