SUPPLY AND INSTLN BATTRYBANK VVPL
GEM/2022/B/2468282
GEM/2022/B/2468282
Open Tender
Unknown (Unspecified Location)
₹0
₹2 L
1 Sept 2022
18 Aug 2022
1 Sept 2022
1 Sept 2022
17 Aug 2022 - 1 Sept 2022
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | VRLA battery Bank,360 AH Telec 11986-VVPL-PIPELINE | VRLA battery Bank,360 AH Telec 11986-VVPL-PIPELINE — PART NAME:VRLA SEALED MAINTENANCE FREE BATTERY; INCLUDING BATTERY STAND/CABINET AND ACCESSORIES AS PER SCOPE OF JOB AND TECHNICAL SPECIFICATION ATTACHED Supply of Battery banks of VRLA 48Volts 2 Volts- 24 nos., 360 AH at CP stations under VVPL.Supply and installation of 2V -24 Nos, 360AH batteries as per technical specifications. Please note that transportation, loading and unloading of new battery bank is also in the scope of vendor. Manpower, tools and tackles required for entire job i.e., inserting the batteries in the existing tray, connections/termination to the batteries circuit is in the scope of vendor.Installation shall include Positioning of Stand, Stand Insulators, Cell Insulators, Leveling, Fixing of Cell number Plates as advised by Engineer-In charge, Interconnection of Cells ( Links Shall be supplied by the Battery Supplier), First Charging, Discharging and Recharging of Battery Bank as recommended by the Manufacturer, Interconnection of Battery Bank with existing Battery Charger as advised by the Officer- In charge.Carry out the charge /discharge cycles at the site using his own Load. HPCL shall not supply the loads etc. Alternatively, vendor may carry out the same at his work location and supply the Battery Bank in fully charged condition. Party has to take a note of the same and the conformance of the same to be given along with the un-priced bid.Capacity test (C10 discharge test) of the battery bank to be carried out at site after installation as part of commissioning. Performance testing shall include Two no of Capacity Testing of each Battery Bank at Eleventh month from the date of installation and Another after six months from the date of warranty completion. Batteries shall be tested under constant discharge current for 10 hrs. of discharge time(C-10) to establish the AH capacity. Replacement of batteries that are not meeting the minimum criteria of IS-1651 & IS- 8320 immediately. AH capacity recorded shall be greater than or equal to the rated AH capacity test. Vendor shall replace all such cells having EDV value less than 1.75 V, free of cost. | - | Each |
| 2 | VRLA battery Bank,720AH CPsta 11986-VVPL-PIPELINE | VRLA battery Bank,720AH CPsta 11986-VVPL-PIPELINE — PART NAME:VRLA SEALED MAINTENANCE FREE BATTERY; INCLUDING BATTERY STAND/CABINET AND ACCESSORIES AS PER SCOPE OF JOB AND TECHNICAL SPECIFICATION ATTACHED Supply of Battery banks of VRLA 48Volts 2 Volts- 24 nos., 720 AH at CP stations under VVPL.Supply and installation of 2V -24 Nos, 720AH batteries as per technical specifications. Please note that transportation, loading and unloading of new battery bank is also in the scope of vendor. Manpower, tools and tackles required for entire job i.e., inserting the batteries in the existing tray, connections/termination to the batteries circuit is in the scope of vendor.Installation shall include Positioning of Stand, Stand Insulators, Cell Insulators, Leveling, Fixing of Cell number Plates as advised by Engineer-In charge, Interconnection of Cells ( Links Shall be supplied by the Battery Supplier), First Charging, Discharging and Recharging of Battery Bank as recommended by the Manufacturer, Interconnection of Battery Bank with existing Battery Charger as advised by the Officer- In charge.Carry out the charge /discharge cycles at the site using his own Load. HPCL shall not supply the loads etc. Alternatively, vendor may carry out the same at his work location and supply the Battery Bank in fully charged condition. Party has to take a note of the same and the conformance of the same to be given along with the un-priced bid.Capacity test (C10 discharge test) of the battery bank to be carried out at site after installation as part of commissioning. Performance testing shall include Two no of Capacity Testing of each Battery Bank at Eleventh month from the date of installation and Another after six months from the date of warranty completion. Batteries shall be tested under constant discharge current for 10 hrs. of discharge time(C-10) to establish the AH capacity. Replacement of batteries that are not meeting the minimum criteria of IS-1651 & IS- 8320 immediately. AH capacity recorded shall be greater than or equal to the rated AH capacity test. Vendor shall replace all such cells having EDV value less than 1.75 V, free of cost. | - | Each |
| 3 | 120AH tbular LA battrybank' | 120AH tbular LA battrybank' — PART NAME:VRLA SEALED MAINTENANCE FREE BATTERY; INCLUDING BATTERY STAND/CABINET AND ACCESSORIES AS PER SCOPE OF JOB AND TECHNICAL SPECIFICATION ATTACHED IGNORE THE ABOVE MENTIONED DETAIL(i.e., VRLA SEALED MAINTENANCE BATTERY). REQUIRED BATTERIES ARE TRANSPARENT TUBULAR LEAD ACID BATTERIES NOT VRLA. PLEASE BE GUIDED BY THE DETAIL MENTIONED BELOW:Supply of 2volt 155 nos. Transparent Tubular lead acid batteries of 120AH for UPS purpose. : Supply and installation of 2V -155 Nos transparent tubular lead acid batteries as per technical specifications. Please note that transportation, loading and unloading of new battery bank is also in the scope of vendor. Manpower, tools and tackles required for entire job i.e., inserting the batteries in the existing tray, connections/termination to the batteries circuit is in the scope of vendor.Carry out the charge /discharge cycles at the site using his own Load. HPCL shall not supply the loads etc. Alternatively, vendor may carry out the same at his work location and supply the Battery Bank in fully charged condition. Party has to take a note of the same and the conformance of the same to be given along with the un-priced bid. The newly installed Battery Banks shall be tested on site for full voltage output for a period of 24 hrs after installation. The delivery period shall include the above activity. Capacity test (C10 discharge test) of the battery bank to be carried out at site after installation as part of commissioning. Replacement of batteries that are not meeting the minimum criteria of IS-1651 & IS-8320 immediately. | - | Each |
| 4 | 350AH tbular LA battrybank | 350AH tbular LA battrybank — PART NAME:VRLA SEALED MAINTENANCE FREE BATTERY; INCLUDING BATTERY STAND/CABINET AND ACCESSORIES AS PER SCOPE OF JOB AND TECHNICAL SPECIFICATION ATTACHED IGNORE THE ABOVE MENTIONED DETAIL (i.e., VRLA SEALED MAINTENANCE BATTERY). REQUIRED BATTERIES ARE TRANSPARENT TUBULAR LEAD ACID BATTERIES NOT VRLA. PLEASE BE GUIDED BY THE DETAIL MENTIONED BELOW:Supply of 2volt 24 nos. Transparent Tubular lead acid batteries of 350 AH . : Supply and installation of 2V -24 Nos transparent tubular lead acid batteries as per technical specifications. Please note that transportation, loading and unloading of new battery bank is also in the scope of vendor. Manpower, tools and tackles required for entire job i.e., inserting the batteries in the existing tray, connections/termination to the batteries circuit is in the scope of vendor.Carry out the charge /discharge cycles at the site using his own Load. HPCL shall not supply the loads etc. Alternatively, vendor may carry out the same at his work location and supply the Battery Bank in fully charged condition. Party has to take a note of the same and the conformance of the same to be given along with the un-priced bid. The newly installed Battery Banks shall be tested on site for full voltage output for a period of 24 hrs after installation. The delivery period shall include the above activity. Capacity test (C10 discharge test) of the battery bank to be carried out at site after installation as part of commissioning. Replacement of batteries that are not meeting the minimum criteria of IS-1651 & IS-8320 immediately. | - | Each |
| 5 | Instlltn&Cmmsng 360AH | Instlltn&Cmmsng 360AH — INSTALLATION, TESTING AND COMMISSIONING OF VALVE REGULATED LEAD ACID (VRLA) BATTERY BANK AS PER ATTACHMENT. Installation and commisioning of Battery bank VRLA , 48Volts: 2V-24 Nos at CP stations, 360AH at various locations of VVPL stations as mentioned in tender attachments | - | Each |
| 6 | Instlltn&Cmmsng 720AH | Instlltn&Cmmsng 720AH — INSTALLATION, TESTING AND COMMISSIONING OF VALVE REGULATED LEAD ACID (VRLA) BATTERY BANK AS PER ATTACHMENT. Installation and commisioning of Battery bank VRLA , 48Volts: 2V-24 Nos at CP stations, 720 AH at various locations of VVPL stations as mentioned in tender attachments | - | Each |
| 7 | Instlltn&Cmmsng 120AH LA bnk | Instlltn&Cmmsng 120AH LA bnk — INSTALLATION, TESTING AND COMMISSIONING OF VALVE REGULATED LEAD ACID (VRLA) BATTERY BANK AS PER ATTACHMENT. IGNORE THE ABOVE MENTIONED DETAIL (i.e., VRLA ). REQUIRED BATTERIES ARE FOR TRANSPARENT TUBULAR LEAD ACID BATTERIES NOT VRLA . PLEASE BE GUIDED BY THE DETAIL MENTIONED BELOW:Installation and commisioning of Battery bank Transparent tubular Lead acid type , for UPS purpose, 2V-155 Nos at CP stations, 120AH at Vijayawada Booster station as mentioned in tender attachments | - | Each |
| 8 | Instlltn&Cmmsng 350AH LA bnk | Instlltn&Cmmsng 350AH LA bnk — INSTALLATION, TESTING AND COMMISSIONING OF VALVE REGULATED LEAD ACID (VRLA) BATTERY BANK AS PER ATTACHMENT. IGNORE THE ABOVE MENTIONED DETAIL (i.e., VRLA ). REQUIRED BATTERIES ARE FOR TRANSPARENT TUBULAR LEAD ACID BATTERIES NOT VRLA . PLEASE BE GUIDED BY THE DETAIL MENTIONED BELOW:Installation and commisioning of Battery bank Transparent tubular Lead acid type , for UPS purpose, 2V-24 Nos at CP stations, 350 AH at Rajahmundry Booster station as mentioned in tender attachments | - | Each |