Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.5 L+₹75,744.80 (13.2%)Rejected-Finance | L2 | Rejected-Finance Other then L1 | |
| 3 | L3₹7.8 L+₹2.0 L (35.1%)Rejected-Finance 1000 PUDA MODEL TOWN PHASE 5 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other then L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
20 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
GE (AF) BHISIANA
AS PER BOQ/PRICE SCHEDULE
2022_MES_540249_1
GE/BHI/T-81 of 2022-23
Open Tender
Civil Works
Item Rate
273 days
GE (AF) BHISIANA
AS PER NIT/TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GE (AF) BHISIANA
₹20,000
Yes
1 Oct 2022
22 Jul 2022
23 Aug 2022
22 Jul 2022
20 Aug 2022
7 Aug 2022
1 Aug 2022 - 5 Aug 2022
Amount
Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles complete all as specified and directed by Engineer in Charge.
M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in cement mortar (1:6) complete all as specified and directed by Engineer in Charge.
M&L for Providing precast cement concrete louvres and jallies 25mm thick type B-0 (1:2:4 using 12.5mm graded aggregate), (measured solid), including all mouldings including dismantling existing lovers or jallies of any type, complete all as specified and directed by Engineer in Charge.
Taking down cement plaster on brick or stone masonry Including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed by Engineer in Charge.
M&L for 15 mm thick Cement plaster in CM (1:4) on fair faces of brick work or concrete surfaces and finishing the surface even and fair (without using extra cement) etc including applying two coat of cement base paint over and a coat of primer after preparation of new plastered surfaces, complete all as specified and directed by Engineer in Charge.
M&L for rough cast plaster on brick wall consisting under coat of cement and sand mortar (1:3) not less than 10mm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even, including applying two coat of cement base paint over and a coat of primer after preparation of new plastered surfaces complete all as specified & directed.
M&L for 15mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair (without using extra cement) etc including applying two coats oil bound distemper (OBD) over a coat of primer and after preparation of plastered surfaces complete all as specified and directed by Engineer in Charge.
M&L for 15mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and fair (without using extra cement) etc including applying three coats white wash and after preparation of plastered surfacescomplete all as specified and directed by Engineer in Charge.
M&L for 5 mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces in ceiling and finishing the surface even and fair (without using extra cement) etc including applying three coats of white wash and after preparation of plastered surfaces complete all as specified and directed by Engineer in Charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed by Engineer in Charge.
M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and othe similar bands, plinth courses, bed plates, copings, kneelers, apex stones, chajjas, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed by Engineer in Charge.
M&L for Applying a coat of white wash over and after preparation of existing old decorated plastered/unplastered surfaces of walls, pillars, cornices by brooming down etc, complete all as specified and directed by Engineer in Charge.
M&L for Applying a coat of white wash over and after preparation of existing old decorated plastered/unplastered surfaces of celing complete all as specified and directed by Engineer in Charge.
M&L for Applying a coat of oil bound distemper over and after preparation of old decorated plastered/unplastered surfaces of walls, pillars cornices etc, complete all as specified and directed by Engineer in Charge.
M&L for complete removal of existing treatment from wall plaster surface by sand paper/electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper all as directed by Engr-in-charge.
M&L for applying interior grade wall care putty 1 to 2mm thick to make the complete all as specified and directed by Engineer in Charge
M&L for two coats oil bound distemper any tint on already prepared surfaces of walls over a coat of primer complete all as specified in SSR Part I and directed by Engr-in-Charge.
M&L for applying two coat of premium quality exterior emulsion paint over a coat of exterior primer of same make on old decorated plastered/unplastered surfacescomplete all as specified and as directed by engr-in -charge.
M&L for Applying a coat of cement base paint over and after preparation of old decorated plastered/unplastered surfaces of walls, pillars, cornices by brooming down etc complete all as specified and directed by Engineer in Charge.
M&L for Applying a coat of synthetic enamel paint over old painted wooden surfaces of any description having width/girth exceeding 10cm, all as specified as directed.
M&L for Applying a coat of synthetic enamel paint over old painted steel/iron surfaces of any description having width/girth exceeding 10 cm complete all as specified and directed by Engineer in Charge.
M&L for preparation of old painted surfaces of bricks/concrete over 10 cm width/girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer in Charge.
Hacking out old broken glass any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins / spring clips and providing and fixing new ones complete all as specified and directed by Engineer in Charge.
S&F sheet glass 3mm thick ordinary quality and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 Sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F figured glass 4mm thick, pin head type and glazing with oil putty in square not exc. 0.5 Sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. end with rod end designed complete all as specified and directed by Engineer in Charge.
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including clamps, nut bolts including dismantling of old AC/PVC rain water pipe etc.
S&F in repairs 110 mm bore PVC (SWR) bends any radius complete all as specified and directed by Engineer in Charge.
S&F in repairss stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and directed by Engineer in Charge.
M&L for 15 mm dia tubes medium grade galvanised with all fitting and fixed to walls and ceilings or laid in floors including taking down and cleaning for removal to store etc complete all as specified and directed by Engineer in Charge.
M&L for 20 mm dia tubes, medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors including taking down complete all as specified and as directed.
GUPTA AND ENGINEERS
M/s Kamal Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .