Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC OK | |
| 2 | L2₹48.0 L+₹47,734.40 (1.00%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹55.1 L+₹7.6 L (16.0%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹89,900
Closing Date
3 Nov 2020, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-10
PROVN OF SERVO VOLTAGE STABILIZER ALONGWITH HT TRIPPING SYSTEM FOR GE CENTRE, PROVN OF 30 KVA ONLINE UPS SYSTEM AT GASTRO AND ENDOCOPY CENTRE AND REPAIR/ MAINTANACE OF UNSERVICEABLE LT UG CABLE ETC AT BASE HOSPITAL UNDER GE E/M BHDC-10
2020_MES_382432_1
GE/BH-46/2020-21
Open Tender
Electrical and Maintenance Works
Works
180 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D, Category b(ii)
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT
₹89,900
Yes
11 Jan 2021
1 Oct 2020
5 Nov 2020
1 Oct 2020
3 Nov 2020
21 Oct 2020
Amount
Supply, installation, testing and commissioning 315 KVA, 11/0.433KV, AN, Oil Type Transformer with corrugated off circuit tap links of rating +5 to - 5% @2.5 %.by means of hand operated off load tap changing gear 315 kVA capacity transformer copper wound step down outdoor type, 11000/433 Volt (at no load), double wound, oil immersed naturally cooled with external cooling tubes, core type delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol Dy-II (vector group) with neutral brought on secondary side (LV side) and having tapping changing at + /-7.5% in step of +/- 2.5 %, to be changed and the maximum temperature rise shall not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be comprised with the following standard fittings including necessary foundation with block masonry work complete all as specified and as directed with following specifications specified in Srl No 1.01 here-in-after:- Note:- Transformer shall be double copper wound (Level -02) as per IS : 1180 (Part -1) 2014 with HT, LT cable Box.
(i) Pressure Release Valve (ii) Thermometer pocket on tank cover (iii) Oil temperature indicator with 2 contacts alarm & trip (iv) Rating plate with terminal marking (v) Two earthing terminals on tank and cover to facilitate fixing of GI earth strip (vi) Oil level gauge (vii) Oil drain filter valve (viii) Lifting lugs (ix) Oil filter hole with cap/plug including connection complete (x) Four plain solid cast steel detachable rollers (xi) First fill of transformer oil confirming to relevant IS and testing up to 60 KV di-electric strength (xii) PCC Foundation with block masonry & Plaster work as per manufacturer's instruction and as directed.
Supply, installation, testing and commissioning Diesel Engine driven generating set of 62.5 KVA capacity, 3 phase, 4 wire, 415 V, 1500 RPM, AC power supply, with power factor 0.8, coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shall have salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application/ installation, integrated design thereby facilitating/ easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer including necessary earth work, PCC foundation with Block Masonry & Plastering work as required at site complete all as specified and as directed including following parts & specifications, specified in Srl No 2.01 to 2.06 here-in-after:-
(A) ENGINE- Water cooled diesel engine of 1500 RPM capacity to match the 62.5 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002. The Engine shall consist of the following :- (i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Radiator fan (Blower type ) with guard (ix) Mechanical governor (x) Fuel filter (Mounted) (xi) Lubricating oil filters (mounted) (xii) 12 v self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resistor /scale inhibitor (xv) Starter 12 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump (Gear type) (xviii) Turbo charger (xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet. (xx) Instrument panel complete with the followings :- (a) Auto manual Starting switch with key (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge (d) Water temperature gauge (e) Battery charging ammeter (f) Battery charging indicating lamp (g) Hour meter with RPM indicator (h) Safety control against high temperature of water. (j) Safety control against low lubricating oil pressure . (k) Over speed stop with double driven adopter.
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364 (ii) Type:- Self excited self regulated with automatic voltage regulator. (iii) Rating:- 62.5 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed:- 1500 RPM (v) System:- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection:- 4 wire star connected . (vii) Enclosure:- Screen protected drip proof . (viii) Ventilation:- Self ventilated. (ix) Insulation:- Insulation class H
(C) CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it shall display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 62.5 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS complete all as specified and as directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF:- (a) Fuel tank - One No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features :- (i) Level indicator. (ii) drain plug . (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (b) Fuel PUMP: Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel. (c) Sealed maintenance free Battery :- Heavy duty battery two Nos 24 plates 12 V 180 AH (01 No) connected to the system fully charged including lead and Battery terminal's complete. (d) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set complete all as specified by the manufacturer.
E) AMF PANEL:- Auto main failure (AMF) panel 15 SWG, 62.5 KVA DG Set Cubical consist of sheet steel enclosure of 2.00 mm thick totally enclosed dust and water proof duly painted with powder coated, ( shade No. 7032 Siemens gray ) fully wired up and ready to connect load & control lines in comprising the followings:- (a) Under Voltage relay 415V AC for main - 01 No. b) Under voltage relay 415 V AC for DG – 01 No. c) AC Timer 230 Volt, 2 No. +2 NC - 01 No. d) DC Timer 12/24 V - 01 No. e) Engine Start relay 12/ 24 V - 01 No. f) Control MCB SP 6 Amp. 230 V – 01 No. g) Transformer 12 / 24 V – 01 No. h) Rectifier suitable size – 01 No. i) LED Indicating Light for Main & DG - 06 Nos. j) LED Indicating Light for Main & Gen. ON – 02 Nos. k) LED Indicating Light for battery Charger – 01 No.
Supply, installation, testing and commissioning 30 KVA, online UPS, with inbuilt isolation transformer and connected Battery Rack and links, Battery circuit Breakers & Accessories including battery bank suitable for 15 Minutes back up with 1 Set of 34 Nos, 12V/42AH Batteries and terminal link with Battery fuse box and including connected accessories along with Mod Bus Card for connecting the UPS to BMS through Rs 485 as per Manufacturers standards complete all as specified and as directed. Note: The detail specification for UPS specified in PS.
Supply, installing, testing and commissioning Outdoor type Feeder Pillar Box, floor mounted, suitable for 415 Volt, 3 phase, 4 wire, 50 Hz, AC supply system, having bus bar chamber with duly insulated Aluminium Bus bars of rating 500 Amps mounted on epoxy/SMC type insulator and the minimum inside depth of panel is not less than 500mm. The panel shall be dust and vermin proof, IP 54 class protection and made out of 14 SWG CRCA sheet and 50 mm x 50 mm x 6mm thick angle iron frame work, 90 cm height and grouted 45 cm in PCC, powder coated finish outside and inside, both side (front and rear) openable type for cable entry, with double door shutter and locking arrangement, internal wiring with PVC insulated flexible copper conductor FRLS cable, IS 694 marked, of adequate size but not less than 1.5 Sqmm complete all as specified and as directed with and inclusive of the following incoming and outgoing feeders:- (a) Incoming :- (i) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 200 Amps rating and 35 KA rupturing capacity : 01 No. (b) Outgoing:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,100 amps rating and 25 KA rupturing capacity - 02 Nos (ii) MCCB 4 pole, LT 415 volts, 50 Hz AC grade, 63 amps rating and 25KA rupturing capacity - 03 Nos Note:- Earthwork and PCC foundation/Platform as per Directions of Engineer in Charge shall deemed to be included in quoted rates.
Supply, laying, connecting and testing cable XLPE insulated, screened, PVC inner sheathed, armoured with galvanised steel strip or wire, electric power cable, heavy duty with stranded aluminium conductor 1100 Volt grade, laid in trenches/ duct, passing through pipe/ duct or fixed on pole, of following size complete all as specified and directed: -
95 Sqmm 3.5 Core
70 Sqmm 3.5 Core
240 Sqmm 3.5 Core
120 Sqmm 3.5 Core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil complete all as specified and as directed.
Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. Note: for measurement purpose punned thickness of sand only shall be considered.
Supply and Laying burn brick size 230 mm X 115 mm X 75 mm etc complete all as specified and as directed.
Supply, laying, connecting and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable, heavy duty with stranded aluminium conductor 11000 Volt grade of size 3 Core, 95 Sqmm earth system complete all as specified and as directed.
S&F cable jointing kit for 11 KV earth grade cable for outdoor type termination, Hot shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm, 3 Core complete all as specified and as directed.
S&F cable jointing kit for 11 KV earth grade cable for Indoor type termination, Hot shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 Core complete all as specified and directed.
M&L Earthing complete with galvanised Iron earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 32X6 mm GI earth strip electrode welded and revetted to earth plate up to a distance of 7.5 metre long, GI earth strip encased in and including 40mm bore GI light grade pipe, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Supplying, installation, testing and commissioning 200 KVA Servo controlled voltage stabilizer in sheet steel ventilated natural oil cooled construction (complete with first filling of transformer oil) having construction is in such a manner that all the 3 units of single phase line voltage stabilizers connected in star. The set shall cater for unbalanced load and unbalance supply provided the input voltage between any phase and neutral and output current in any phase shall be with in limits as specified below including necessary foundation with block masonry work complete all as specified and as directed: - I/P Voltage : 320V-480B 3 Phase unbalance I/P Frequency : 47-53 Hz O/P Voltage : 415V ± 1%, 3 Phase,50 Hz O/P should be star connected as per is 9815 O/P Adjustment : ± 5% of Rated O/P O/P Voltage accuracy : Better than + 1% Rating : 200 KVA at UPF Load : Unbalance Speed of correction : 70V / Sec (Ph-Ph) Efficiency : Better than 96% Waveform distortion : Nil Effect of load : Nil Environment : Indoor tropical use Ambient : 0-50 Deg. C. Material for windings : Copper The Servo controlled voltage stabilizer shall also have following additional features: Full solid state control circuit, No effect ON load Power factor, Auto/manual operation facility, Tripping indication : High/Low I/P voltage tripping with overload /short circuit tripping facility, By pass arrangement with changes over switch, Audio visual alarm circuit, Indicator for I/P/O/P Volt O/P Amp frequency meter Digital/Analog.
Supply, installation, testing and commissioning 11 KV, 630 Amps, Indoor type Compact switch gear Ring Main unit (RMU) Extensible type CVV+ having 01 No. Load Break Switches and 02 Nos Vacuum circuit breaker all Motor Operated modules (total number of modules 3 pcs) with IP class as IP 54 for indoor separately, inside the RMU there shall be an additional cable door with IP3X and Mimic of IP2X and necessary PCC foundation work as recommended by manufacturer along with bottom cable entry and front cable termination complete all as specified and directed with following specification & accessories, specified in Srl 19.01 to 19.06 here-in-after:-
(A) 630A motorised Load Break Switch module for making of fault current along with Earth Switch of full making capacity - 01 No. Short time withstand current - 21KA/ 3 sec Making Capacity - 52.5kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38KV Impulse withstand voltage - 95kVp Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable up to 3 core 300 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots - 01 Set (R,Y,B) Set of 03 Nos. Ring Core Metering CTs 150-300 - 01 No as per feeder load, 2.5VA, Class 1.0 - 01 No.
(B) 630A Motorised VCB module for making & breaking of fault current along with Earth Switch of full making capacity - 02 Nos. Motorised operated 630 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec Making Capacity - 52.5 kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38KV Impulse withstand voltage - 98kVp Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Green(ON)/ Red(OFF) push buttons to operate VCB. 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Mechanical ON/OFF/EARTH/Spring charge Indication Cable boxes should be Arc Proof interlocked with respective Earthing Switches. Right angle non-touch proof Termination boots - 01 Set (R,Y,B)
Stored energy mech. for Motor operation - 01 No. Control Voltage, motor operation 24V DC - 01 No. Self powered OC+EF Protection Relay - 01 No. Set of 03nos. Ring Core Protection CTs of ratio 40-80A - 01 No as per feeder load, 2.5VA, 10P10 - 02 Nos Set of 03 Nos. Ring Core Metering CTs of ratio 40-80A - 01 No as per feeder load, 2.5VA, Class 1.0 - 01 Set Capacitive voltage indication fixed type VPIS 6-12 kV - 01 No.
(C) Set of 03 Nos. single-phase potential transformers having ratio 11kV/rt3:110V/rt3, 25VA, Class 1.0 with HRC fuses for protection on primary side and MCBs for protection on secondary side. - 01 Set Space Heater (230VAC) - 01 No. Low Voltage Box containing • Multifunction Meter for each module showing kV, A, kVAR, kW, Hz etc, in the same. • R-Y-B Phase Indication Set of Coupling bus bars along with suitable coupling kit. - 01 No. Manometer - 01 No. Operating handle - 01 No.
Notes for Item No 19.00: - (a) RMU shall be IAC AFLR 20 KA/1S tested with gas release from top of the Switchgear to ensure utmost operator and pedestrian safety. Test report (from an STL member Lab) shall be submitted along with drawings of the RMUs. In case the test report is not found suitable, the RMU shall stand liable to be rejected. (b) The Vacuum Bottle shall be of same make as that of RMU to ensure better lift cycle optimization for the RMU. (c) Additional items like Operating handle etc, shall be delivered with the RMU. (d) RMU shall be completely Motorised with all SCADA contacts for monitoring of LBS/VCB(control not required)terminated on a designated Terminal Block for easy take off by the SCADA team for integration in future. Also, motorization of RMUs shall be possible at a later date, if required .Same contacts shall be clearly mapped in the Engineering drawings for approval with designated TB nos. for easy identification and integration. (e) RMU tank shall be of 304 grade, Non-magnetic, Non-ferrite Stainless Steel. Inferior Grade of Steel shall not be acceptable. (f) RMU shall have site replaceable bushings for ease of trouble shooting at site and quick repair and restoration at site.
Notes for Item No 19.00 (Contd...): - (g) Earth switch should be on line side and should have making capacity. (h) Contractor shall purchase RMU directly from OEM and necessary factory inspection shall be arranged before dispatch RMU from OEM premises. The testing officer shall be nominated by accepting officer after written confirmation received from contractor for RMU is ready for testing with all respect as per CA provision. All testing and inspection shall be carried out in OEM premises in presence of testing officer and contractor. The joint inspection report shall be submitted after completion of testing. All expenditure in this respect shall be bore by contractor and inclusive in quoted rate. No other charges admissible to contractor in this respect after ward. (j) The rates inclusive of making Platform as per OEM recommendation made with bricks and necessary PCC at Bottom and Top and plastering complete all as directed.
Supply, laying, connecting and testing in repair cable XLPE insulated, screened, PVC inner sheathed, armoured with galvanised steel strip or wire, electric power cable, heavy duty with stranded aluminium conductor 1100 Volt grade, laid in trenches/ duct, passing through pipe/ duct or fixed on pole, of following size including taking down old cable complete all as specified and directed:-
400 Sqmm 3.5 Core
300 Sqmm 3.5 Core
240 Sqmm 3.5 Core
185 Sqmm 3.5 Core
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
70 Sqmm 3.5 Core
50 Sqmm 3.5 Core
25 Sqmm 4 Core
16 Sqmm 4 Core
16 Sqmm 2 Core
S&F cable jointing kit for 11 KV earth grade cable for straight through Joint, heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 Core complete all as specified and as directed.
M&L in repair sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length).
M&L in repair sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length).
M&L in repair sub main wiring with 2 runs of 10.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 10.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 10.0 Sqmm cable and one run of 10.0 Sqmm earth conductor along with 32 mm PVC conduit with accessories shall be measured as one length).
M&L in repair sub main wiring with 4 runs of 10.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 40 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and 2 run of 10.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Four run of 10.0 Sqmm cable and Two run of 10.0 Sqmm earth conductor along with 40 mm PVC conduit with accessories shall be measured as one length).
S & F in repair distribution board (DB), double door (CRCA sheet), dust and vermin proof SPN, 4 way, with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 10 or equivalent Model of Make mentioned in Appx 'B' to Particular specifications.
S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 8 way, with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 11 or equivalent Model of Make mentioned in Appx 'B' to Particular specifications.
S &F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 12 way, with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 12 or equivalent Model of Make mentioned in Appx 'B' to Particular specifications.
S & F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN, 4 way, with 200 Amps rated copper bus bar, 415 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 45 or equivalent Model of Make mentioned in Appx 'B' to Particular specifications.
S & F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN, 8 way, with 200 Amps rated copper bus bar, 415 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 47 or equivalent Model of Make mentioned in Appx 'B' to Particular specifications.
S & F in repair MCCB TP, 100 Amps capacity, 25 KA, DPX3 thermal magnetic, 420 Volts, complete all as specified and directed.
S & F in repair MCCB TP, 125 Amps capacity, 25 KA, DPX3 thermal magnetic, 420 Volts, complete all as specified and directed.
S & F in repair MCB SPN, 240 Volts, 32 to 63 Amps, C curve, complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 6 to 32 Amps, C curve complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 40 Amps, C curve complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 63 Amps, C curve complete all as specified and directed.
M/s Adhikari construction co.
SANJEEV ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .