| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹34.5 L+₹70,573.35 (2.09%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹35.5 L+₹1.7 L (4.93%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹38.0 L+₹4.1 L (12.2%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹40.5 L+₹6.6 L (19.6%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
1 Mar 2021, 6:00 pmClosed
GE NASIRABAD
GE Nasirabad Nasirabad cant, Pin 305601 (raj)
PROVN OF SECURITY LIGHTS AT 150 FD REGT, HIGH MAST LIGHT IN MT GARAGE OF B COY OF 5221 ASC BN, RECOVERY ROOM AND DAY CARE ROOM FOR MDC, TOILET WITH BATHROOM AT OFFICE COMPLEX OF 150 FD REGT,EXECUTION OF CERTAIN REVENUE,MINOR WORKS AT NASIRABAD
2021_MES_414250_1
8126/E8
Open Tender
Civil Works
Item Rate
183 days
NASIRABAD
AS PER NIT class D and category a(i) bldg works
6 documents required · 6 mandatory
₹500
GE Nasirabad
₹78,000
Yes
16 Apr 2021
19 Jan 2021
3 Mar 2021
19 Jan 2021
1 Mar 2021
16 Feb 2021
19 Jan 2021 - 3 Feb 2021
Amount
Surface dressing not exc 15cm deep in soft/loose soil.
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in any type of soil (soft or loose/hard & dense), complete, all as specified & directed.
All as per description of serial item No. 2 above but exc 1.5 metre and not exc 3.0 metre in depth.
All as per description of serial item No. 2 above but excavation in soft and disintegrated rock.
M&L for PCC 1:4:8, type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete, all as specified & directed.
M&L for cement concrete (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. (Note: Only Inner girth shall be measured.)
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:6 complete all as specified & as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exc 20mm, lime or sand stone.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
M&L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete, all as specified & directed.
M&L for 40mm thick PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in damp proof course on horizontal surface using water proofing compound including necessary formwork. Note : - Supply only water proofing compound shall be measured and paid separately.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface all as directed.
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic & sand (1:3).
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Earth filling under floors including spreading, leveling, watering and well ramming in layers not exc 25 cm thick. Note :- Soil obtained from excavation under serial item No. 106 here-in-before shall be used for filling under floors.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
M&L for reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete, all as specified & directed.
All as per description of serial item No. 18.00 here-in-before but 6 to 8 mm dia bars.
All as per description of serial item No. 18.00 here-in-before but 6 to 10mm dia in stirrups, spacers and binders.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in foundations including rafts, footings, foundation beams, bases for columns, mass concrete and the like, complete, all as specified & directed. .
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete, complete, all as specified & directed.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in columns, pillars, piers, posts, struts and the like, complete, all as specified & directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete, complete, all as specified & directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in lintels over 1.5m clear span, seismic and other similar bands, lintel bands, plinth bands, roof bands and the like, complete, all as specified & directed.
Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete, complete, all as specified & directed.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like, complete, all as specified & directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete, complete, all as specified & directed.
Formwork to edges of concrete flats, roofs, floors etc and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces, complete, all as specified & directed.
M&L for rendering 15mm thick in cement mortar 1:4 mixed with water proofing compound in the proportion as recommnded by manufacturer on fair faces of brick masonry, concrete or stone masonry surfaces of walls, finished even & smooth without using extra cement, complete all as specified. (WPC shall be measured and paid separately)
M&L for rendering 15 mm thick in cement mortar 1:6 on than fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified.
M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified.
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, chajjas, isolated width etc., finished even & smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick masonry or stone masonry surfaces of walls, finished even & smooth without using extra cement, complete all as specified.
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete, all as specified & directed.
M&L for preparation of newly plastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash, complete, all as specified & directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint, complete all as specified & directed.
S&F vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc and, making good to floor, complete all as specified & directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, complete all as specified & as directed.
S&F vitreous china urinal, flat back, half stall type, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia, complete, all as specified & directed.
S&F PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle, complete, all as specified & directed.
S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides, complete, all as specified & directed.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F soap dish holder (Cat Part No ACN-1131N of complete all as specified & as directed. Make - Jaquar or equivalent of Marc/Parryware/Somany/Parko/Gem/Prayag)
S&F vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified.
S&F 15mm bore fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes.
S&F 15 mm bore bib tap, cast copper alloy, ISI marked,chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule.
S&F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 100 gms).
S&F tubular towel rail, aluminium anodized, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete, all as specified & directed.
S&F brass chromium plated shower rose 125 mm size without swivel joint including fixing to steel pipe of 15mm bore or union complete all as specified.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed on wall with PVC rawl plug & cadmium plated brass screws, complete all as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 over and including 25 mm thick PCC 1:2:4, type B0 using 12.5mm graded stone aggregate, complete all as specified and directed.
All as per description of serial item No. 54.00 above but on verticle surfaces such as skirting etc., over & including 10mm thick screed plaster in cement & sand mortar 1:4 complete, all as specified and directed.
M&L for glazed ceramic tiles (coloured) 7mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed backing in cement & sand mortar 1:4 complete, all as specified and directed.
M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L for machine cut Kota stone slab 18 to 20mm thick (550mm x 100mm or size as directed), on vertical surfaces such as dado, skirting etc. laid over & including screed bed or bedding layer of 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
S&F factory made steel ventilator factory made made out of MS hollow section 79 mm x39 mm x 1.6 mm thick frame with double shutter (glazed & wire gauzed shutter) made out of 'Z' section using flush butt welding and tennon riveting, all as per IS 1038/83, dobby hinges shall be provided to both shutters, locking arrangements, 25mm aluminium knobs to shutter, aluminium hook & eye, 10mm MS square bars in grill, 04 Nos lugs welded to frame 'Z' section handle, 100 mm including necessary flat iron beading for securing wire gauge etc including holes, cutting holes for hold fast and making good in PCC 1:2:4, type B1 including two coat of synthetic enamel paint over a coat of zinc crome/red oxide primer, complete, all as specified & directed. Note:- Wire mesh and sheet glass shall be measured and paid separately. with top hung shutter including hinges, steel peg stay, handle complete all as specified.
S&F second class hard wood (Hollock/Bonsum/Sal) factory made 35 mm thick plain framed, paneled shutter (two or three panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & directed.
S&F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing, conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
S&F mild steel holdfast, hook and pintle hinges, large hasp and staples, clamps, hooks for hanging fans and similar small articles conforming to Grade E-165 (Fe 290) including necessary welding etc. and fixed in position.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour single piece extruded PVC profile reinforced with MS square tube in opening as per specifications.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with plain colour single piece extruded PVC profile ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour single piece extruded PVC profile for top rail lock rail bottom rail on either side and as gap insert for Top rail and bottom rail paneling of plain colour PVC sheet to fitted on the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane , complete all as specified.
Supply and fixing stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete, all as specified & directed.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified
S&F aluminium handle, 150mm size, fabricated type, anodized (ISI marked) complete all as specified.
S&F butt hinges of size 100 mm medium weight, cold rolled mild steel ISI marked, complete, all as specified & directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, copings and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified.
Supply only integral water proofing compound (ISI marked).
S&F PVC (SWR) floor trap, plain with PTMT grating including jointing with solvent cement, diameter of outlet 75mm, complete.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints, laid in trenches or floor, complete all as specified& directed.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints, laid in trenches or floor, complete all as specified& directed.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints,fixed to walls with clamps, complete all as specified& directed.
S&F PVC (SWR) Gully trap 125/110mm, setting and jointing with solvent cement or PCC 1:2:4, type B1, complete all as specified & directed.
S&F 110 mm bore PVC (SWR) junction single (single ‘T’), equal or unequal with oval access door.
S&F 75 mm bore PVC (SWR) bend, any radius with access door.
S&F 110 mm bore PVC (SWR) bend, any radius with access door.
S&F 75 mm bore PVC (SWR) vent cowl.
S&F 110 mm bore PVC (SWR) vent cowl.
S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) of 1000 litre capacity, triple layered, hoisted and fixed in position, complete, all as specified in SSR Part - I and as directed. Note :- (i) The unit rate quoted by tenderer shall be deemed to insulate water tank with GI pipe medium grade 10cm long projected inside and outside of tank with bore suitable for inlet and outlet, GI pipe 20mm bore medium grade projecting 10cm inside and outside of the tank for over flow, GI pipe 20mm bore medium grade projected 10cm inside and outside of tank for vent & mosquito cover for vent/overflow pipe.
All as per description of serial item No. 83.00 above but of 500 litre capacity.
M&L for galvanized steel water tubing medium grade of 15 mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors, complete, all as specified & directed.
All as per serial item No. 85.00 here-in-above but of 20 mm bore pipe.
All as per serial item No. 85.00 here-in-above but of 25 mm bore pipe.
S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20mm bore (minimum weight 210 gms), complete, all as specified and directed.
M&L for 40mm thick sand stone slabs, set and jointed over joist etc in CM 1:4 as in base of water tank including 25mm thick PCC 1:2:4, type B0 using 12.5mm stone crushed aggregate (for providing bottom base of PVC tank) complete, all as specified & directed.
M&Lfor PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe all as specified and as directed.
S&F salt glazed stone ware drain pipes of 100 mm bore, grade `A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified.
S&F salt glazed stone ware drain pipes of 150 mm bore, grade `A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified.
M&L for Reinforced concrete pipes, 150mm bore, class NP2, laid in trenches and jointed complete with collars, all as specified & directed.
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed.
Supply & laying FRP septic tank package type waste water treatment system (PWTS) Model No. PWTS-AM-180-01 of Sintex or equivalent approved make of size 1490 mm dia and 1615 mm height including necessary inlet & outlet pipe designed to carry sewage and salvage water, with upflow filter including media including necessary excavation, PCC (1:4:8) below foundation bed, vent pipe, inlet and outlet connection pipe upto 2.00m length etc, complete all as specified and directed. Make :- Sintex or Equivalent MES approved make.
Construction of RCC septic tank, stone construction including excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-25 Design Mix in walls, base slab, baffle wall and roof slab including beams etc with vent shaft, manhole openings with connection etc, complete for 50 users, complete, all as specified and shown on drgs CEBZ/TD/81 /11 sh No 1/1 complete all as specified and directed..
M & L for soakage wells including excavation in any type of soil, foundation in PCC (1:4:8), walls of honey combed fly ash brick masonry with top ring of RCC 1:1.5:3 type A-1 concrete including intercepting chamber and screen chamber made of fly ash brick masonry in CM (1:6), RCC cover slab in1:1.5:3 type A-1 & SFRC MH cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80m dia & 3.0m effective depth all as per drg No. CEBZ/TD/78 /2011 sh No 1/2 & 2/2 complete all as specified and directed.
M & L for soakage wells including excavation in any type of soil, foundation in PCC (1:4:8), walls of honey combed fly ash brick masonry with top ring of RCC 1:1.5:3 type A-1 concrete including intercepting chamber and screen chamber made of fly ash brick masonry in CM (1:6), RCC cover slab in1:1.5:3 type A-1 & SFRC MH cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80m dia & 4.50m effective depth all as per drg No. CEBZ/TD/78 /2011 sh No 1/2 & 2/2 complete all as specified and directed.
M&L for factory made 60mm thick machine pressed precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment laid over & including 50 mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & directed.
M&L for 75 mm thick PCC (1:3:6), type C2 using 40 mm graded crushed stone aggregate as in sub base of floor, surface finished fair and even,complete, all as specified & directed.
M&L for 75 mm thick PCC (1:4:8), type D2 using 40 mm graded crushed stone aggregate as in sub base of floor, surface finished fair and even,complete, all as specified & directed.
M&L for 100 mm thick PCC (1:4:8), type D2 using 40 mm graded crushed stone aggregate as in sub base of floor, surface finished fair and even,complete, all as specified & directed.
S&F 20 mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipecomplete, all as specified & directed. .
M&L for cutting existing GI water pipe line for addition and ateration, screwing the existing steel tubing in position and insertion of required size of GI fittings, (ie union, nipple, reducing tee) for branch connection of internal dia 25/20 mm bore, complete all as directed.
M&L for 20mm thick black granite slab of approved shade, as in kitchen platform etc, bedded & jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing as per local trade practice, complete, all as specified & directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1 mm thick finished coat of white wall care putty, complete, all as specified & directed.
M&L for preparation of newy plastered surfaces of wall and applying two coats of weather proof water base emulsion paint with modified acrylic exterior wall finished with silicon adhesive on walls, complete, all as specified and directed.
S&F aluminium door shutters with frame of aluminium section weighing not less than 0.55 Kg/RM including necessary joining cleats, glazing clips, rubber neoprene packing, brass handle and brass tower bolts of size 150mmx 02 Nos in each door, hinges, anodised aluminium snap beading screws, hydraulically regulated double action floor spring made up of 1.25 mm thick aluminium alloy sheet, foundation box for each shutter etc and including fitted with 5 mm thick tinned glass in glazed shutter with brass mortice lock of 100mm , 2 levers, vertical type, complete, all as specified in clause 10.37 of SSR Part I & directed by Engr-in-Charge.
S&F aluminium window/ventilator shutter with frame, sliding/side hung type with sash bars including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc and including each window fitted with 5mm thick tinned glass in glazed shutter, duco pattern aluminium anodised grill (weight not less than 2.625 Kg/Sqm) and stainless wire cloth 0.36mm nominal dia and average width of aperture 1.40mm in gauzed shutter etc, complete, all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:4 on roof top surfaces, mixed with water proofing compound as per manufacturer's instruction, finished even & smooth without using extra cement, complete, all as specified & directed.
M&L for APP modified polymeric water proofing membrane, 2 mm thick having centre core not less than 100 micron high molecular high density polythelene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 3 Kg/Sqm applied with bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.2 Kg/Sqm over bitumen primer conforming to IS-3384 @ 0.40 Kg/Sqm with final coat of bonding bitumen grade 85/25 @ 1.2 Kg/Sqm over APP membrane with all overlaps, complete, all as specified & directed.
M&L for 40mm thick (average consolidated thickness) type B0 using 12.5mm graded stone aggregate as in padding even and smooth without using extra cement with existing slope with 'V' shaped grooves 6mm wide and 10mm deep @ 1.2m interval or part thereof, both ways on top of padding and filled with mastic bitumen of 1:1 proportion, complete, all as specified & directed.
Providing & fixing false ceiling with fibre cement designer tile Ivory painted (High pressure steam cured) of 4mm thickness (As per IS: 14862) of size 595x595mm and any one of the design (Oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (Galvanised @ 120 Gms, both side inclusive) consisting of Main ‘T’ runner with suitably spaced joints to get required length and 15x32mm made from 0.3mm thick sheet, spaced at 1200mm C/C and cross ‘T’ of size 15x32 mm made of 0.30 mm sheet, 1200 mm long spaced between main ‘T’ at 600 mm C/C to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600mm and size 15x32mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 15x20mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including, required cutting/making, opening of services like diffusers, grills, light fittings, fixtures, smoke detectors etc main ‘T’ runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rod of 3mm dia with galvanised butterfly level clips, spaced at 1200 mm C/C along main ‘T’ bottom exposed width of 15mm of all ‘T’ sections shall be centra black pre-painted with polyester paint and having a load bearing capacity of 12 Kg/Sqm, complete at all heights as directed by Engr-in_charge. Make: Everest/Armstrong
M&L for 18/19mm thick block board, Grade 2 quality, interior grade, commercial type and both faces covered with approved pattern decorative coloured laminate type 1 of 0.9mm thick and all around side faces is covered with decorative teak wood lipping 19x6mm , complete as in shelves, pelmet boxes, almirah book case, racks , cup board shutter etc and fixed with wooden frame work, complete, all as specified & directed.
S&F continuous (piano) hinges, mild steel, bright finish or electro galvanized width of flaps 30mm (when open) fixed with CP steel screws.
S&F 50mm dia polished hardwood knobs, fixed with screws, complete, all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
Excavation in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface in soft/ loose soil.
S&F mild steel work as in angle iron in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) and similar works conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
M&L for cement concrete1:2:4 type B0 (12.5 mm graded stone aggregates) as in fixing of vertical post/copping including necessary form work etc complete all as specified and directed.
M&L for 5 cm thick sand stone slab in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc not exc 2m in length, punched dressed on face and along exposed edges, self faced on the other side and set and pointed in cement mortar 1:4 complete.
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
Cutting into existing manholes/Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150mm bore pipe.
M&L for cast iron soil and waste pipe 100mm bore waste or vent pipe in any length with or without ears with cement joints on verticle surfaces of wall complete, all as specified and directed.
M&L for 8 layer outdoor acrylic synthetic badminton court (Size 48'x24') as per standard specification, complete, all as specified & directed by Engr-In-Charge. (First layer of primer, 2nd & 3rd layer of resurfacer, 4th, 5th & 6th layer of cushion, 7th & 8th layer of colour)
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, multi stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick( Make - Hylem/Anchor) ISI Marked, brass screws and cup washers including 1.5 Sqmm multi stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed for:- Make of wire- Havells/Polycab/Anchor/Finolex. Make of PVC conduit -AKG/Plaza/Kalinga
All as per serial item No. 126.00 here-in-above but one light point/bell point controlled by one, one way switch.
All as per serial item No. 126.00 here-in-above but one ceiling fan/exhaust fan point controlled by one, one way switch.
All as per serial item No. 126.00 here-in-above but one three pin 5 Amp socket on same board with other switches.
S&F Switch piano, flush type, single pole, one way, 5 Amps, 240 volt, 50Hz, AC, complete all as specified and as directed by Engr-in-Charge. MAKE:-Havells/Anchor/Legrand
S&F Socket outlet 3 Pin 5/6 Amp flush type complete all as speciied and directed by engr-in-Charge. MAKE:-Havells/Anchor/Legrand
S&F ceiling rose surface bakelite 3 terminals complete all as speciied and directed by Engr-in-Charge MAKE:-Havells/Anchor/Legrand
S&F of lamp holder PVC/polycarbonate type with back plate complete all as speciied and directed by Engr-in-Charge. MAKE:-Havells/Anchor/Legrand
S&F of LED lamp 9/11 watt complete all as specified and directed.. MAKE:-Havells/Anchor/Legrand
S&F LED mirror light fitting 10 Watt sleek polycarbonate channel with white acrylic cover complete with all accessories pre-wired and including connecting flexible copper conductor cable with suitable size. Make Havells/Bajaj/Osram
S&F LED light fittings, 1x 10 W bulk head luminaries, with lamp etc complete with all accessories and including connecting up with three core copper conductor cable of suitable size of 230V, 50 Hz, including taking down old existing unserviceable bulk head light fitting of any type and size, complete all as specified and directed. Make: Bajaj Code No BIBWP 10W LED or equivalent from Havells /Crompton greaves
Supply & fixing, testing and commissioning energy saving street light luminaire 15 watt LED , aluminium pressure die cast housing with tughened glass cover with individual LED lence , IP 66 protection complete all as specified and directed by Engr-in-Charge. Make-Bajaj Cat No. BCLST 15W LED or equivalent model of Surya/Havells/C & S.
S&F street light bracket made of 32 mm GI pipe , 1.2 mtr lenght fixed with two nos of clamp , nut and bolts complete all as specified and directed.
Supply & fix ventilating fan 300mm sweep suitable for 230 Volts, Single phase 50 Hz AC supply, metal body with bird guard including connecting with three core flexibale copper cable. Make Bajaj/Usha / Crompton/Havells
S&F of MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 4 way, 240 volts suitable for housing MCB's including blanking plate complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
All as per description of serial item No. 137.00 above but 8 ways.
S & F of MCB SPN, 240 volt, 20 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge by Engr-in-Charge. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F of MCB SPN, 240 volt, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge by Engr-in-Charge. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge. . Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
Supply and, laying, including jointing, testing or fixing or passing through pipe, trench or duct, commissioning and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade size 10 Sqmm, 2 core complete all as specified and directed by Engineer-in-Charge. Make Polycab/Asian/Gloster/Finolex
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top cable including spreading, levelling, watering and consolidation, complete all as specified and directed by Engineer-in-charge. Note: Punned thickness only shall be measured and paid.
Supply and laying of bricks of old class ‘B’ as protection cover to UG cable, laid flat adjoining to each other width wise, complete, all as specified.
Supply and laying GI tubing 40 mm bore, light grade with all fittings, laid in trenches/under floor or fixed on pole/on wall with suitable mild steel clamps, nuts. bolts and washers, for cable protection.complete, all as speified & directed.
All as per description of serial item No. 145.00 above but of 50mm bore pipe.
M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed cable in and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed in walls/roof/ ceiling with suitable size of sunk type pressed steel modular terminal box and modular white cover plate with frame of suitable module as per site requirements for mounting of modular switches, sockets, fan regulator etc and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth for the following, complete all as specified and directed:
All as per serial item No. 147.00 here-in-above but One light point/fan/bell controlled by one way 5 Amps SP switch
All as per serial item No. 147.00 here-in-above one 5 pin 5 Amps socket outlet on same board with other switch
All as per serial item No. 147.00 here-in-above one 5 Pin 5 Amps socket outlet on independent board with other switch.
All as per item No 147.00 above but with 2.5 Sqmm cross sectional area electric cable for 15 Amp socket outlet on independent board, complete all as specified and directed.
All as per item No 147.00 above but with 4 Sqmm cross sectional area electric cable for 15 Amp socket outlet on independent board, complete all as specified and directed
S&F modular switch 1 way 6/10Amp , 1 module, complete all as specified and directed.
S&F modular switch 1 way 16Amp, 1 module, complete all as specified and directed.
S&F modular socket 6Amp, 2/3 pin combined 2 module complete all as specified and directed.
S&F mdoular socket 6Amp/16 Amp, 2/3 pin combined 2 module complete all as specified and directed.
S&F modular stepped type ceiling fan regulator, 230 Volts AC, 2 module, complete, all as specified and directed.
S&F LED tube light fitting retrofit batten in acrylic linear tube single LED tube light including 1 x 20 W LED retrofit bar professional CW 6500 K cover channel, bipin holders, LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling (1x 20 watt), 230V for rose complete all as specified and directed. Make: Crompton Cat No LTTB-20 & IGP161LT8-16 or equivalent fromPhilips / Bajaj
Supply and fixing recess mounted 2' x 2' LED luminarie 36 watt, warm white light with white powder coated CRCA housing with LED driver, complete all as specified and directed. Make : Havells Cat Part No. TOCR2x2R 34W LED 857SPCPMS/ Bajaj Cat Part No. BPRF 36W WH LED/ Halonix HLCR22-TO01-36-CW
S&F ceiling fan of 1200 mm sweep, 230 Volts, AC 50 Hz, copper winded, high speed, BEE star rated as per latest norms with motor, blades (03 Nos), down rod, canopy & shackle assembly including 0.5 sq mm three core PVC insulated flexible wire with mulitstranded copper conductor from ceiling rose to connector of ceiling fan and writing of MES No, complete, all as specified and directed by Engr-in-Charge. Make: Havells ES 50 or equivalent from Crompton/ Usha/Orient as approved by the GE.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh, PCC chamber in cement concrete 1:3:6 type C-2 and RCC 1:2:4 type B1 cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 incl dismantling of old unsv existing earthing, complete, all as specified & directed.
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty electric cable with aluminium multi stranded conductor, 1100 volt grade, 10 Sq mm 4 core nominal cross section, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drain /culvert duly encased in galvanised pipe including cable gland of suitable size and aluminium lugs for connection, complete, all as specified & directed.. Note :- Excavation & earth and GI pipe shall be measured separately
All as per description of serial item No.157.00 above but of 16 Sqmm, 4 core cable
S&F street light Engineering plastic one piece moulding control box with locking arrangement made out of HDPE and FI clamp 25x3mm complete including one MCB SP 6 Amp 240 Volt complete with 02 Nos aluminium busbar of rating 63 Amp for single phase and neutral on porcelain based insulators and fixing clamps to pole for street lights, complete all specified & directed. Make Sintex/ Hensel /SHI/BRITE
Supply, errecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31), 09 metre long, complete with cast iron base plate, pole cap/final taper plug ,bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire lenght of pole, including bracket made of 1.2 m long 40mm bore GI light grade pipe, made to shape with 2x MS clamps & nut-bolts for fixing bracket to poles including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint, complete all as specified and directed.(Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed. Note:- (a) Cost of numbering of pole shall be deemed to included in unit rate. (b) Excavation, Earth work and PCC foundation will be measured and paid for separately.
M&L for PCC 1:3:6, type C2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete, all as specified & directed.
S&F PVC insulated sheathed with solid aluminium conductor cable 2.5 sqmm 2 core 1100 volt grade for connecting from street light to pole box complete, all specified and directed.
S & F LED street light luminaries 72 Watt made of single piece Aluminium Die cast with powder coated in RAL-7032 shade with heat distribution fins onhousing with UV stabilized toughned flass cover and should have secondary lens on each LED for better light distribution .The system luminaire efficiancy should be > 110 LM/W with high power LED's. LED driver should be potted and BIS certified with efficiency > 85 % frequency 50 HZ,Operating voltage range 120V-270V, current not more than 0.320 Amp, PF 0.95, THD (I) < 10 %, supported with 5 KV internal and 10 KV external SPD, Humidity 10% to 90 % RH, working temperature - 20⁰ C to 50⁰ C lige expectancy of LED should be 50000 burning houres with minimum 70 % initial lumene maintained, CRI >70, complete, all as directed. Make:- Cat Part No LSTP-72-CDL-M OF Crompton or equivalent from Philips/Wipro
M&L for carrying out boring under the black top road for crossing of LT cable/protection pipe by mechanical boring machine or otherwise without damaging road surface as per latest technique for fixing of GI pipe 80 mm bore under the road complete all as specified and directed.
Supply, fixing and testing Street light automatic Nature switch of capacity 5 KW single phase complete with using infrared sensor based NATURE SWITCH for automatic switching of street lights. Nature Switch operation should be based on Nautral Light Lux* level. Required illuminance level for switching ON is ≤ 30 Lux and for swiching OFF ≥ 10 Lux. The sensor should also have part night operation facility of min.4 hrs to max 12 hrs. The sensor along with suitable power contactor(s) and incoming-outgoing MCBs should be enclosed in a pole/wall/panel mountable Rust proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure ( with Hinged LID) conforming to IP66 protection class 2. The circuit should also have provision for Manual Operation(i.e Sensor By-Pass option). Make - Kakatiya Energy system Model SWADEEP-66-5KW 1P or equivalent from Havells .
Supply, installation and testing of 16 meter, high mast conforming to IS-875 (Part - III) - 1987, made out of steel plates conforming to BS - EN10025 cut and folded to form a tapered polygonal section in two section having 20 sides, sectional thickness of base section 4mm & top section 3mm, dia of base section not less than 360mm & top section 150mm in two section suitable for wind speed of 180 Km/hour type double drum , number of ropes 2 for Winch, 3 for Lantern carriage and stainless steel wire rope of grade AISI 316, and consturction 7/19 and 6mm dia breaking Load capacity 2350 Kg and trailing cable copper conductor 5 core, 2.5 sqmm flexible insulatin circuit's per mast is one, including power tools (reversible) 440V, 50Hz, 1HP/1.5HP capacity (motorised system for bringing up and down the lights) and aviation light (LED Type) lightening arrestor spike . The mast should consist of 9 X mounting bracket suitable for LED flood light fittings as per manufacturer design including material and labour for excavation and earth work and RCC foundation in any type of soil as per manufacturer instructions / design duly approved by GE and its errection should be carried out under the supervision of manufacturer's representative, complete, all as specified and directed. Make: Crompton; Cat Part No HM-16A-LM-ACC or equivalent from Bajaj as approved by GE Note:- (i) LED Flood light fittings shall be measured and paid separately under relevant of BOQ. (ii) LED flood light and High mast should be of same make.
S&F integral LED flood light luminaire of 200 Watt made up of pressure die cast aluminium housing with toughned glass and high power LEDs and secondary lenses with IP 66 protection. System efficiency > 110 LPW. Option for 3000 K, 10 KV SPD included with all fixing arrangements, nuts, bolts and washers connecting to electric system with 1.5 Sqmm PVC copper stranded conductor 2/3 core cable of required length from light fitting to street light control box/control switch on pole/panel/Timer, testing on completion, complete, all as specified and directed.Make: Crompton; Cat Part No LFNL-200-CDL/60-M or equivalent from Bajaj as approved by GE.
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.50 metre below normal ground level, earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using galvanized strip 32 X 6mm as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead encased in and including 50 mm bore GI light grade pipe from upper end of earth plate up to equipment with & including 20mm bore GI pipe light grade watering pipe from earth chamber to upper edge of the earth plate. GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4, type B1 using 20mm graded stone aggregates duly reinforced with mild steel round bars 6mm @ 150mm C/C both ways with 10 mm dia MS bar as in lifting handle with and including necessary excavation & earth work including laying the GI pipe concealed in floor/wall, complete, all as shown on electrical plate No 3 of SSR Part – I and as specified & directed including testing on completion. Note :- If the desired earth resistance is not found earthing shall be redone by the contractor without any extra cost to Govt
M/s SUNIL ENTERPRISES
kirtiman traders
PD GUPTA AND COMPANY
M/S JAGDAMBA ENTERPRISES
MITTAL ENTERPRISES
VIPRABANDHU CONSTRUCTIONS
pankaj and company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .