Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC MODEL TOWN PATIALA | ₹7.2 L | L1 | Accepted-AOC AOC issued |
| 2 | L2₹7.2 L+₹5,022.08 (0.70%)Rejected-Finance | ₹7.2 L+₹5,022.08 (0.70%) | L2 | Rejected-Finance L2 |
Tender Value
₹7.3 L
EMD Value
₹14,557
Closing Date
4 May 2026, 5:00 pmClosed
Superintending Engineer
Municipal Corporation Patiala
Rough Cost Estimate of providing and laying 8 UPVC SN8 Sewer line located at Baba deep Singh Nagar near Badi Nadi in MC Patiala ward no. 21 Est Cost Rs. 7.27 lacs dt 04/05.05.2026
2026_DLG_166816_1
MCP/2026/36-38/10
Open Tender
Miscellaneous Works
Percentage
60 days
Patiala
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹14,557
Yes
21 Aug 2026
27 Apr 2026
5 May 2026
27 Apr 2026
4 May 2026
27 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out existing CC interlocking paver
blocks from footpath/ central verge/pavement,
including removal of rubbish etc., disposal of
unserviceable material to the dumping ground,
for which payment shall be made separately
and stacking of serviceable material within 50
metre lead as per direction of
Engineer-in-Charge. | 36.79 | sqm | 59.24 | ₹2,179.45 |
| 2 | Excavation of trenches in a Streets, Lanes or in Open Area for Storm Sewers and Manholes to Full Depths as Shown in Drawings,excluding Shoring, Timbering of Poling Board Frame System Type, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines.night signals, profiles, Pegs, Sight rails, boning rods, crossing over trenches for access to the houses, watching, fencing etc., fixing and maintenance of caution boards, refilling trenches, watering of refill in 15 cm layers, ramming and restoration of surface to original conditions and removal of Surplus Spoil from the Site of Works, for all Works other than connections to Ventilating Shafts upto a Lead of 15 mtr
For depth not exceeding 2 m below Ground
leve All classes of soil except rocky | 158.68 | cum | 235.98 | ₹37,445.8 |
| 3 | Providing, laying in trenches to correct
gradient and alignment and jointing of UPVC
pipes having ISI specification IS:15328-2003
class-SN-8 marked make Supreme, Finolex,
Kissan, Jain, Prince or equivalent good on
them and laying the same in trenches to
correct alignment and gradients, cutting and
jointing, testing for water tightness and
making good the leakages and defects
including cost of specials (Specials and Solvent
should be of same make as that of pipes)
complete in all respects.
200mm o/d pipe | 126.52 | m | 3,144.32 | ₹3,97,819.37 |
| 4 | Constructing brick masonry manhole in
cement mortar 1:5 ( 1 cement : 5 coarse
sand ) R.C.C. top slab 20cm thick using M-20
mix by using mixer and vibrator, TMT Fe500
@ 80.00 kg/per cum, foundation concrete
1:4:8 mix (1 cement: 4 coarse sand : 8
graded stone aggregate 40mm nominal size)
inside plastering 12mm thick with cement
mortar 1:3 (1 cement: 3 coarse sand) finished
with floating coat of neat cement and making
40mm thick benching in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20mm nominal size) finished
with a floating coat of neat cement, Orange
coloured PVC steps including RCC cover with
frame complete as per standard design
complete in all respects
Inside size 75x120 cm and 120 cm deep | 3 | no | 19,004.09 | ₹57,012.27 |
| 5 | Extra payable for every 0.30 m additional
depth of manhole chamber in item 29.55 upto
1.80 m increase in depth Inside size 75x120 cm | 6 | each Depth of 0.30 m | 2,338.77 | ₹14,032.62 |
| 6 | Construction of brick masonry inspection
chambers size as given below upto 0.60 metre
average depth in 1:5 cement sand mortar,
C.C.1:4:8 ( 150mm thick) in foundation,
cement concrete 1:2:4 benching 12.50mm
thick cement plaster 1:2 with a floating coat of
1mm thick of neat cement, R.C.C. 1:2:4 slabs
100mm thick cement concrete topping 50mm
thick with 455mm x 455mm, 455mm x
610mm inside R.C.C. inspection chamber
cover and frame (Weight as per I.S.I
specifications) painted with 3 coats of black
bitumastic paint conforming to I.S.I complete
as per standard design 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal | 9 | no | 8,970.55 | ₹80,734.95 |
| 7 | Extra for every 0.30 metre depth of inspection
chamber 600mm x 900mm inside | 9 | each Depth of 0.30 m | 1,842.57 | ₹16,583.13 |
| 8 | Dismantling of old S.W. pipes including
breaking of joints and bed concrete stacking of
useful materials and disposal of unserviceable
materials within 100 m as desired by
Engineer-in-Charge 150 mm Diametre | 126.15 | m | 56.89 | ₹7,176.67 |
| 9 | Disilting of manhole including all safety
measures, cost of container T & P and disposal
of silt upto 5km complete in all respects. Depth upto 3 m | 2.49 | cum | 1,810.97 | ₹4,508.88 |
| 10 | Making connection of newly laid sewer in walls
of existing manhole of fully charge sewer
including cost of pluging sewer, desilting,
removal of sullage water and making good of
khudda Sewer connections upto 300 mm id | 1 | one connection | 6,384.21 | ₹6,384.21 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_338669.xls
BOQ • 0.33 MB
tenderdocuments.rar
Tender Documents • 5.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .