Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹35.4 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹36.0 L+₹56,730 (1.60%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹36.7 L+₹1.3 L (3.60%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
8 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE JAMMU
GE JAMMU
CERTAIN MINOR WORK, REVENUE WORK AND LBW WORK OF EM NATURE AT MIRAN SAHIB UNDER GE JAMMU
2023_MES_608861_1
GEJC-52/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AOR OF GE JAMMU
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE JAMMU
₹80,000
Yes
28 Aug 2023
13 Jul 2023
10 Aug 2023
13 Jul 2023
8 Aug 2023
27 Jul 2023
Amount
Supply and fix electric water heater geyser, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc complete all as specified and as directed. Note:- Rates are deems to be includes the cost for fixing of 4 Nos rawl plug of suitable size (4" to 6 ") nuts and bolts , grouting work in RCC/ Brick wall.
M&L point wiring independent taking direct from existing main DB installed at entrance complete using with 2.5 Sqmm (nominal area), PVC insulated, multistranded, unsheathed, copper conductor cables drawn through and including Concealed in PVC Conduits with all accessories complete fixed to walls /ceiling etc. with and including 2.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including 1.6 mm thick mild steel sunken boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light/fan/bell point controlled by one ,one way switches complete all as specified and as directed.
S&F Switch socket outlet combined 2 in 1 , 3 pin 5 amp and `15 amp flush type , 240 volts complete all as specified and as directed.
M&L for cutting to existing pipe 15/20mm dia in position and insertion of T , additional alteration in position complete with GI fittings as required at site for connecting New GI pipe complete all as specified and directed by Engr-in-charge.
Supply and fix Galvanised iron pipe medium grade of size 15mm complete with all fittings such as bend, tee, reducer, elbow and union of require size complete all as specified and directed. Note:- Rates are deemed to be included for fixing of MS clamps of suitable size to hold the GI pipe.
Supply and fix gun metal or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15 mm dia complete all as specified and directed.
M&L PVC connection pipe heavy duty ISI marked of 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Supply and fix Bib Tap fancy type cast copper alloy with crutch or butterfly handle, screwed down for iron pipe 15mm dia complete all as specified and as directed.
M&L for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 4.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through in new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note : Wiring shall be done in proper colour coding.
Excavating in trenches n.exc 1.5 mtrs wide and n.exc 1.5 mtr in depth for foundation of poles, taking out/laying of cables, poles etc and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated materials n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point in soil, complete all as specified and as directed.
Supply and Laying well burnt bricks, sub class 'B' bricks, laid breath wise in trenches for protection of UG cable complete all as specified and directed.
M&L for sand cushioning for protection of cable (below, above and around the cable laid in trenches) complete all as specified and directed.
S&F GI tube light grade 40 mm bore laid in trenches/road/drain/wall alongwith all fittings complete with MS clamp and nut bolts and washers etc, alongwith all fixing accessories complete all as specified and directed.
Supply and laying in trenches, fixing or passing through pipe, fixed to wall/pole, connecting and testing for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sq mm, 3.5 core, complete all as specified and directed by Engr-in-Charge. Note: Wherever cable fixing/connection, suitable thimble should be used as per site situation
S&F DB Sheet metal enclosures double door, factory made, made out of CRCA mild steel sheet 1.2 mm thick with matellic painting, FP-42 protection surface mounting 240 volts, 200 Amp rated enameled neutral bus bar 8 way dust and vermin proof suitable for incorporation of Isolator / MCBs. duly concealed in wall and making good the distrubed surface and colour matching complete all as specified and as directed.
S&F MCB single pole 240 volts, 06 to 40 Amps,"B" series 10 KA complete all as specified and as directed.
S&F MCB single pole neutral 240 volts, 40Amps, ,"B" series 10 KA complete all as specified and as directed.
S&F distribution board double door (suitable for incomer MCCBs and out going MCB) TP & N vertical load line 6 Way complete with 200 Amps bus bar, 415 Volt sheet metal enclouser suitable for G frame MCCB complete all as specified and as directed.
S&F Isolator 4 Pole, TPN 415 volts, 100 Amps rating with rupturring cap 16 KA, complete all as specified and as directed.
S&F MCB single pole neutral 240 volts, 63 Amps, ,"B" series 10 KA complete all as specified and as directed.
M & L for Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip of size 25x4mm by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation and earth work GI pipe 40mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with RCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt layers each layer thickness should be 15 cm (layer start from below the electrode plate to above plate) etc, connected as indicated including testing complete all as specified and as directed. (resistance should be less than 1 ohm)
S&L and testing cable XLPE Insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 25 Sqmm, 4 core complete all as specified and directed.
S&L and testing cable XLPE Insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 35 Sqmm, 3.5 core complete all as specified and directed.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
HARPAL ENGINEERS AND BUILDERS
Sarbat Construction Co
Bidder Name
Sarbat Construction Co
Harsh Electricals
HARPAL ENGINEERS AND BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .