Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
24 Nov 2022, 6:00 pmClosed
Col Jigar Trivedi, SM
HQ CWE (AF) Gurgaon Old Palam Road, Delhi Cantt - 10
REPAIR MAINT OF HT SF6 33 KV BREAKERS 11 KV RMU HT CABLES and VCB INCL TRANSFORMERS AT AF STN CHANDINAGAR UNDER GE (AF) FARIDABAD
2022_MES_560025_1
CWE/GGN/FT-20/2022-23
Open Tender
Electrical and Maintenance Works
Works
90 days
AF STn Chandinagar
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Faridabad
₹20,000
Yes
23 Jan 2023
27 Oct 2022
1 Dec 2022
27 Oct 2022
24 Nov 2022
11 Nov 2022
27 Oct 2022 - 10 Nov 2022
Amount
Disconnecting HT supply and taking out trolley of SF6 Circuit breaker 33 KV indoor type 630 Amps and servicing of trolley by cleaning isolating contacts , removing dust particles from Bus bar chamber and Spout gear mechanism and moving parts lubricating moving parts repair/replacement of parts testing as mentioned below and system complete all as specified and directed . Note: (i) Measurment of resistance value, tools , labour, petroleum jelly , dry cloths, nut -boltsare, CRC, washers etc incl in the quoted rates. (ii) Contractor will provide company authorised dealer/service centre test / representative test report of internal resistance of breaker and operating time. (iii) Primary and secondery injection test to be carried out without any extra cost to department.
Opening &closing coil -110 V DC
Auxilairy contact (7NO +7 NC)
New Micro switch with ball
New Micro switch without ball
RC unit assbly
Shock Absorber (top)
Pressure switch single Level
O Ring
TNC switch
Support insulator 36 KV
Tulip contact 15 finger
contact bolt
Bushing -R 36 KV VHA Cub (1250 A)
Disconnecting HT supply and taking out trolley of 11 KV RMU SF 6 indoor type and servicing of RMU by cleaning isolating contacts , removing dust particles from Bus bar chamber and Spout gear mechanism and moving parts lubricating moving parts replacement of worn out unserviacable parts /components and testing complete as mentioned below complete all as specified and directed. Note: (i) Measurment of resistance value, tools , labour, petroleum jelly , dry cloths, nut -boltsare, CRC, washers etc incl in the quoted rates. (ii) Contractor will provide company authorised dealer/service centre test / representative test report of internal resistance of breaker and operating time. (iii) Primary and secondery injection test to be carried out without any extra cost to department. (Note : Parts will be measured & Paid Separately as under)
Bushing 400 series bolted type
Triping coil and closing coil 110 V DC for RMU
shaft for operating handle
Aux switch
Insulated bushing cover
IDMT relay testing with primary and secondary injection kit with TMS setting Curve settiong and relay programing
Anti Pumping device
Vaccum interruptor 2.4" dia
Spring Charging Motor with motor & operating coils
Closing Spring assembly
Motor Cut limit Switch
TNC switch
Auxillary switch (7 NO +7 NC)
Supply and fixing of combined over current and earth fault numerical relay with input current and auxiliary voltage V incl complete installation in 33 kV RMU panel, complete connections and testing at 33 KV sub stations all as specified and directed. Note: (i) Relay will be fixed in existing HT panel incl cutting , welding, drilling or any other suitable means or will be fixed in separate cabinet without any extra cost to department (ii) All type of wires required for proper connection will be provided by contractor without any extra cost to department. (iii) Proper functioning and testing will be carried out without any extra cost to department.
Supply and fixing of combined over current and earth fault numerical relay with input current and auxiliary voltage incl complete installation in 11 kV RMU panel, complete connections and testing at 11 KV sub stations all as specified and directed. Note: (i) Relay will be fixed in existing HT panel incl cutting , welding, drilling or any other suitable means or will be fixed in separate cabinet without any extra cost to department. (ii) All type of wires required for proper connection will be provided by contractor without any extra cost to department. (iii) Proper functioning and testing will be carried out without any extra cost to department.
Supply and fix of Current Transformer suitable for SF6 RMU 11 KV panle current ratio is 60/30/1 Amp and class IP-10 protection complete all as specified and directed.
M& L in replacement of cable jointing kit for 33 KV grade cable for indoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 120 Sqmm 03 core complete all as specified and directed .
M& L in replacementof cable jointing kit for 33 KV grade cable for outdoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 120Sqmm 03 core complete all as directed.
Material and labour for straight through joint Cold shrinkable 33 KV earthed system suitable for XLPE cable of size 3 x 120 Sqmm incl taking down old unsv HT joint complete all as directed .
M& L in replacement of cable jointing kit for 11 KV grade cable for indoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 95 Sqmm complete all asspecified and directed.
M& L in replacement of cable jointing kit for 11 KV grade cable for outdoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of Size 95 Sqmm complete all as specified and directed.
Material and labour for straight through joint Cold shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 95 Sqmm incl taking down old unsv HT joint complete all as specified and directed.
Supply, install, test and commission lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating incl complete connections in replacement complete all as specified directed.
M&L for PT Fuse indoor 33 KV (3.15 A) complete all as specifed and as directed.
Supply only in replacement of Blue silica gel 4-6 mesh suitable for transformers breather and protect HT/LT panels from moisture as per site requirement complete, all as specified and as directed.
M&L for replacement of AC Ammeter of size suitable for existing ampmeter with input 0 -1 AAC and range 0 - 40 AAC with CTR 40/1A Aux supply 230 V ; 50 Hz complete incl all connections and programme setting in existing 33 KV main incoming Panel all as specified and as directed.
M&L for replacement of AC Voltmeter with input 0-120 V AC and range 0-36 KV AC with CTR 40/1A Aux supply 230 V ; 50 Hz complete incl all connections and programme setting in existing 33 KV main incoming panel all as specified and as directed.
M&L for replacement of existing Multi function meter with input 0-120 V AC and range 0-36 KV AC with 33 KV/110 V Aux Supply complete incl all connections and programme setting by the service engineer in existing 33 KV panel as per meter placed in panel all as specified and as directed.
M &L for calibration of Auxillary relay for transformer trip functions such as bucholz relay trip/WTI trip/OTI trip fixed on 33 KV control panels for power transformer with all respects and making all alignments properly including connecting with phase indicator on control panels for smooth functioning of tripping system complete all as specified and directed.
S&F in replacement compact LED type DC indicator lamp & holder assembly of capcity 50 Volts of colours as in existing panel with fitting /fixtures suitable for 33 KV and 11 KV VCB control panels connections with existing wiring & taking out old unservicable indicators from panel completete all as specified and directed.
S&F in replacement digital type Ampere Meter suitable for 11 KV RMU /VCB panel to Check the outgoing load connections with CTs & taking out old unservicable meter from panel completete all as specified and directed.
Supply and fix in replacement push to close /open button assembly for Circuit Breaker 33 KV complete all as specified and directed.
Supply and fix in replacement push to close /open button assembly for Circuit Breaker 11 KV complete all as specified and directed.
S&F in replacement PT Fuse 11 KV suitable for 11KV/110 V PT completre all as specified and directed
M&L for detecting of fault in HT UG cable any size with fault locator equipment to locate the fault in HT cable of length not less than 50 RM . Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator and DG set including transportation charges deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality will levied Rs 1000/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting , joint making Joint will be paid under relevant item.
Dehydration including filtration and cleaning of transformer at site by centifugal dehydration machine till to achieve Di-electric strength 40 KV at 2.5 mm gap including testing of sample before and after dehydration and filtration complete all as specified and as directed. NOTE : - (i) Contractor has to arrange the dehydration machine and testing kit without any extra cost of Govt (ii) Any damage occurred to transformer during the process of dehydration, shall be made good by the contractor to the entire satisfaction of the Eng-in-charge at his own expenses.
Supply and pouring new transformer oil as per IS : 335 (Latest revision) for transformers installed at various site or in repair for topping up after dehydration to achieve the di electric strength 60 KV at 2.5 mm gap, complete all as specified and as directed. Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.
Supply and fixing in replacement for non-metal part HV bushing complete with packing for outdoor/indoor/canopy type power transformer (33 /11 kV) of capacity 1000 KVA complete all as specified and as directed.
Supply and fixing in replacement HT, brass bush rod of suitable size for outdoor type power transformer (33 /11 kV) of capacity 1000 KVA complete all as specified and as directed.
Supply and fixing in replacement for non-metal part HV bushing complete with packing for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV)of capacity upto 400 KVA complete all as specified and as directed.
Supply and fixing in replacement HT, brass bush rod of suitable size for indoor type distribution transformer (11 /0.433 kV) of capacity upto 400 KVA complete all as specified and as directed.
Supply and fixing in replacement for non-metal part LV bushing with packing for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 400 KVA complete all as specified and as directed.
Supply and fixing in replacement LT bush rod made of brass of suitable size for outdoor/indoor/canopy type distribution transformer (11 /0.433 kV) of capacity upto 400 KVA complete all as specified and as directed.
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 400 KVA with silica Jel complete all as per specification and direction of Engr-in-Charge.
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity of 1000 KVA with silica jel complete all as per specification and direction of Engr-in-Charge.
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing all as directed by Engr-In-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt shall be measured and paid separately.
Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed .
Opening the transformer cover along with the conservator by removing the nuts bolts then after removing the internal H.T. & L.T. connections by taking them out by removing studs, bushings, taking out the core-winding assembly out of the tank of transformers having ratio 11/0.433 KV, draining & decanting of transformer oil and cleaning of sludge deposited in the tank with CTC for the transformers. Heating of core winding assembly in hot chamber for 48 hours and removing all the moisture present in it, removal of leakage of tank if any by welding, refilling transformer oil to tank, after putting the core-winding assembly into the tank, reassembling, making the internal HT & LT connections by fixing the studs, bushing, fitting the top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop duly filled with oil including transportation from site to workshop and back all as directed for various capacities as under:- Note : - Item will be executed after board proceeding conveyed by Garrison Engineer in presence of competent checking authority.
(a) Above 250KVA upto 400 KVA
Supply only super enamelled copper winding wire/ strip of any size for H.T. coils of transformers all as specified.
Supply only copper winding strip of any size for L.T. coils of transformers including providing insulation all as required.
Net Contract Sum will be after deducting Sch of Credit of Rs 1,09,925.00
SB ENTERPRISES
Akhil Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .