Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC | ₹22.1 L Quoted ₹22.6 L | L1 | Accepted-AOC Awarded Being Lowest Bidder |
| 2 | L2₹23.0 L+₹41,606 (1.84%)Rejected-AOC | ₹23.0 L+₹41,606 (1.84%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹23.9 L+₹1.3 L (5.82%)Rejected-AOC | ₹23.9 L+₹1.3 L (5.82%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹23.9 L+₹1.4 L (6.05%)Rejected-AOC | ₹23.9 L+₹1.4 L (6.05%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹24.1 L+₹1.6 L (6.94%)Rejected-AOC | ₹24.1 L+₹1.6 L (6.94%) | L5 | Rejected-AOC Rejected |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 Feb 2021, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathrdi Road Opp Ahmednagar Fort Ahmednagar-414002
Repairs to path hard standing chain link fencing barbed wire fencing boundry wall area drainage culverts kerb stones and plinth protection under AGE B/R I area at GE (N) Ahmednagar
2021_MES_413043_1
8491 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class E Cat a(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹50,000
Yes
2 Mar 2021
16 Jan 2021
20 Feb 2021
16 Jan 2021
18 Feb 2021
30 Jan 2021
Amount
Dismantling of stone slab and tiles of any description in floors laid, bedded and pointed in any mortar etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced) in ground floors and paving not exc 15 cm thickness below or above ground level etc complete all as specified and directed by Engineer-in-Charge
Material and labour for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base etc complete all as specified and directed by Engineer-in-Charge
Material and labour for 60-62mm thick, PCC pavers interlocking tiles of glossy finish, any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5mm graded mechanically crushed stone aggregates, factory made over and incl 30mm thick sand cushioning and joints filled with fine sand incl leveling & sweeping etc complete all as specified and directed by Engineer-in-Charge
Material and labour for rough dressed Shahabad stone, 25 mm to 40 mm thick laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), laid and jointed pointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge
All as per item No 5 (here-in-before) but except stone slab
M&L for Digitally printed paver tiles 300mm x 300mm having thickness of 10 mm thick as approved by GE of with grey cement and pigment, machine pressed, factory made, set, jointed and pointed in neat cement slurry in floors over and including screed bed 15mm thick in cement and sand mortar (1:4) finished even and fair etc complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete chequered tiles 30cm X 30cm X 30 mm thick with grey cement and pigment, machine pressed, factory made, set, jointed and pointed in neat cement slurry in floors over and including screed bed 15mm thick in cement and sand mortar (1:6) finished even and fair complete all as specified and as directed.
M&L for stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement and sand mortar (1:3), joints 20mm thick; grouted in cement and sand mortar (1:2) with an admixture of metallic floor hardener 5% by weight of cement and struck flush
All as per item No. 9 (here-in-before) but except stone
M&L for edge stones to flooring with stone setts of size 250 to 300mm long x 150 to 200mm wide, and 450mm deep etc complete all as specified and directed by Engineer-in-Charge
Demolition of PCC block masonry / stone masonry / Kerb Stone built in cement mortar including coping etc complete all as specified and directed by Engineer-in-Charge
Precast cement concrete (1:2:4) type B-I ( using 20 mm graded stone aggregate ) as in road side kerb stones (Factory made ) and similar articles with plain faces, including chamfers weathering throating etc, set in cement and sand mortar (1:4), etc complete all as specified and directed by Engineer-in-Charge
M&L precast cement concrete block masonry Type C1 (1:3:6) with solid blocks, exc 10 cm in width and setting in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
All as per item No 14 (here-in-before) but except block masonry
M&L for preparation of old / new surface of walls, kerb stone and concrete surface & applying two coats of acrylic (antifungal) exterior grade paint on wall & etc complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC (1:2:4) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection, concrete road or parking area finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture etc complete all as specified and directed by Engineer-in-Charge
Dismantling fencing wire mesh any type and any description etc complete all a s specified and directed by Engineer-in-Charge
S&F mild steel angle iron for fencing posts and struts including cutting tops to shape, as directed, drilling holes, notching for wire etc flat iron fillets for securing wire mesh including all necessary drilling, bolting or riveting etc and similar work conforming to Fe.290.Gde-E-165 etc complete all a s specified and directed by Engineer-in-Charge
S&F mild steel bolts, 10 mm dia and 65 mm long, purpose / machine made with hexagonal head or square head one end and crewed on other end, each screwed end to be fitted with washer and on hexagonal or square nut etc complete all a s specified and directed by Engineer-in-Charge
Fixing only chain link fencing including line wires, any mesh, size & type to any type of standards, rails straining bolts etc including provision of binding wire etc complete all a s specified and directed by Engineer-in-Charge NOTE: Chain link fencing shall be measured and paid as separately as supply only.
Supply only chain link fencing made cut from GI wire 10 gauge and 50 mm aperture weight not less than 3 kg / Sqm etc complete all a s specified and directed by Engineer-in-Charge
S&F in repairs galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all a s specified and directed by Engineer-in-Charge NOTE: Each line of wire to be measured.
S&F 10 mm dia mild steel round bars to tighten chain link fencing including necessary hooking, binding cutting etc complete all a s specified and directed by Engineer-in-Charge
M&L for plain cement concrete in PCC 1:4:8 type D2 using 40 mm graded aggregates in foundation, filling and mass concrete or similar work etc complete all a s specified and directed by Engineer-in-Charge
M&L for flat iron 40 X 6 mm cut to required length including drilling holes for fixing of nut and bolts to hold chain link fencing etc complete all a s specified and directed by Engineer-in-Charge
Taking down cement plaster on brick/stone walls including taking out joints hacking for keys, scrubbing down with water etc complete all a s specified and directed by Engineer-in-Charge
M&L for rendering, 15 mm thick on stone masonry / brick work / concrete surfaces in cement mortar 1:4 on wall finished even and smooth without using extra cement etc complete all a s specified and directed by Engineer-in-Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all a s specified and directed by Engineer-in-Charge
M&L for cement concrete 1:2:4 type B2 (using 40mm graded stone aggregate) as in surface channel or drain etc complete all a s specified and directed by Engineer-in-Charge
S&F in repairs 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all a s specified and directed by Engineer-in-Charge
M&L preparation of newly / old plastered surface and applying three coats of white wash on wall etc complete all a s specified and directed by Engineer-in-Charge
M&L for plain cement concrete in PCC (1:3:6 )type C1 using 20 mm graded aggregates in surface channel and drain etc complete all a s specified and directed by Engineer-in-Charge
M&L for Providing, plain cement concrete (1:2:4) type-B1 using 20 mm graded aggregate in coping on top of manhole or mud stops, chamfered on edges etc complete all a s specified and directed by Engineer-in-Charge
M&L for 450 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars etc complete all a s specified and directed by Engineer-in-Charge
An amount of Rs 50,550.00.00 shall be deducted from BOQ on account of schedule of credit
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .