Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹41.0 L+₹1.0 L (2.52%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L2₹42.5 L+₹2.5 L (6.30%)Rejected-AOC NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC Rejected | |
| 4 | L4₹44.1 L+₹4.2 L (10.4%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
25 Feb 2021, 6:00 pmClosed
SHUBHAM PRAKASH
GE(NORTH) UDHAMPUR
GE/U(N)-75/2020-21 PROVISON OF STORE ROOM AT ASC AND NEAR BLDG NO P-50 RAISING OF BOUNDARY WALL NEAR STN HQ INCLUDING SPECIAL REPAIR TO BLDG NO P-15 OF ASC BN ALONG WITH REVENUE WORKS UNDER AGE B/R-II OF GE (NORTH) UDHAMPUR
2021_MES_417641_1
GE/U(N)-75/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
CLASS D
7 documents required · 7 mandatory
₹500
GE(NORTH) UDHAMPUR
₹82,000
Yes
11 Mar 2021
1 Feb 2021
27 Feb 2021
1 Feb 2021
25 Feb 2021
12 Feb 2021
Amount
Dismantling floor , hearth or wall tiling including cement mortar bedding ( but not backing ), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engir-In-Charge.
Dismantling of steel windows/ventilators any description and fixed in any postion including grill etc, complete all as specified and as directed.
Demolition of cement concrete (Unreinforced) ground floor n.exc 15 cm thickness at any situation for kitchen floor complete all as specified and directed by Engir-In-Charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed by Engir-In-Charge.
Demolitioin of Unreinforced cement conc of any description and in any position complete all as specified and directed by Engir-In-Charge.
Dismantling of wrought iron or mild steel any dia work of any description complete all as specified and directed by Engir-In-Charge.
Demolation of brick work or stone boulder masonery built in cement mortor including all quoins arches pillars etc all as specified
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out inany type of soil complete all as specified and directed by Engir-In-Charge.
Excavating in trenches n. exc. 1.5 m wide, and n.exc. 1.5 m in depth for foundation etc. n.exc. 10 sqm on plan and n. exc. 1.5 mtr in depth and getting out hard/ dense soil complete all as specified and directed by Engir-In-Charge.
Excavation in trenches n.exc 1.5m wide & n.exc 1.5m in depth getting out in any type soil complete all as specified and directed by Engir-In-Charge.
Removing excavated material n.exc 50m & depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engir-In-Charge.
Returning filling in including spreading levelling watering & well ramming in layer not exc 25cm complete all as specified and directed by Engir-In-Charge.
Plain cement concrete type E-2 (1:5:10) 40mm graded agg as in founadations and mass concrete complete all as specified and directed by Engir-In-Charge.
Hard core of broken stones/ boulders of gauge not exc 63mm deposited spread & levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed by Engir-In-Charge.
Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) complete all as specified and directed by Engir-In-Charge.
Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius butt in cm 1.6 complete all as specified and directed by Engir-In-Charge.
- ditto - but except brick complete all as specified and directed by Engir-In-Charge.
Half brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius but in cm 1:4 complete all as specified and directed by Engir-In-Charge.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work n.exc. 200 mm thick curved ( horizontal or sloping ) with fair finished surfaces for flat roof complete all as specified and directed by Engir-In-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engir-In-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engir-In-Charge.
Form work to soffits of suspended slabs such as roof and similar work n.exc. 100mm thick complete all as specified and directed by Engir-In-Charge.
Reinforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like complete all as specified and directed by Engir-In-Charge.
Reinforced cement concrete(nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engir-In-Charge.
Reinforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in columns piers posts and struts complete all as specified and directed by Engir-In-Charge.
Reinforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in foundation footings complete all as specified and directed by Engir-In-Charge.
Reinforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Chajjas complete all as specified and directed by Engir-In-Charge.
Providing Precast cement concrete 1:2:4 type B-1 Using 20 mm graded stone aggregate as in kerb Stones and in similar works bedded and jointed in CM 1:6 incl necessary exc if necessary complete all as specified and directed by Engir-In-Charge.
Providing Precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in anchorage blocks for hold fast in walling, set in cement mortar 1:4 with plain fair faces including chamfers weathering etc completa all as specified.
Plain cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in coping. Kneelers, bed block including necessary from work complete all as specified and directed by Engir-In-Charge.
M&L for providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified.
TMT Bars , 10mm dia over cut to length , bent to shape reqd including cranking bending and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified .
Ditto but 5mm dia and over up to and including 10 mm dia in stirrups, spaces and binders complete all as specified and directed by Engir-In-Charge.
Plain cement concrete 1:3:6 type C-2 using 40 mm thick graded agg using Plinth Protection 75 mm thick complete all as specified and directed by Engir-In-Charge..
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection even and smooth with using extra cement complete all as specified.
Providing (1:4:8) Type C-2 (using 40 mm graded stone aggregate) as in floors or pavings 75mm thick complete all as specified and directed by Engir-In-Charge.
Providing 50 MM thk cement concrete type B-2 (1:2:4) 40mm graded agg laid in floors as in plinth protections complete all as specified and directed by Engir-In-Charge. .
Forming construction joint 30 mm deep x 10 mm wide filled with sealing compound grade 'B' complete all as specified and directed by Engir-In-Charge.
Providing 25mm thick PCC 1:2:4 type B1(20mm graded stone aggregate) in flooring complete all as specified and directed.
Providing 40 mm thick PCC (1 :2:4) type B1 using 20mm graded agg as in floors complete all as specified and directed by Engir-In-Charge.
Machine pressed precast interlocking paver blocks any shape and size with grey Cement and Pigment confirming to IS 15658-2006 of 60mm thickness (M-35 Grade) complete all as specified and directed by Engir-In-Charge.
Vitrified ceramic tiles (Double charge) any colour 10mm thick(Square or rectangular) poliahed, area of each tile exceeding 0.64 sqm but not exc 1.00 sqm in floor etc,Set and jointed in neat cement slurry and pointed in coloured cement to match including bedding layaers of CM 1:4 (20mm thick) all as per specified & directed by Engr-In-Charge.
Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 10 mm thick screed bed or bedding layer in CM 1:4 , complete all as specified and directed by Engir-In-Charge.
Glazed ceramic coloured tiles as per IS-13753, 300mm x 450 mm x 7 mm or 350 x250x7mm thick on vertical surfaces such as skirting /dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing coat complete all as specified and directed by Engineer-in-Charge.
18-20mm thick machine cut Kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing & including 15 mm thick (average thickness) cement mortar (1:4) screed complete all as specified and directed by Engineer-in-Charge.
Kota stone slab 18-20mm thick in skirting, dado and pillar laid over cement screed and jointed with rey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engir-In-Charge.
20mm thick granite (of any type) work (table rubbed and polished )in steps,jambs ,pillers,windows cills,cooking plateform and like in cm(1:4) including pointing in white cement(1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed in cm(1:4) complete all as specified and directed by Engir-In-Charge.
Sand cushoning bed (filling under floors) incl spreading levelling watering if required complete all as specified and directed by Engir-In-Charge.
Taking down cement plaster of any description on bricks, PCC block or stone walls, etc. Including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engir-In-Charge.
15mm thick rendering on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
15mm thick Rendering on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:4), including integral WPC by wt of cement as per manufacturer instruction (NOTE : Supply only WPC will be measured and paid for separately), complete all as specified and directed by Engr-in-charge.
10mm thick rendering on fair face of brick work or concrete surfaces CM (1:4) complete all as specified and directed by Engir-In-Charge.
10mm thick rendering on concrete surfaces to be finished even and smooth ( w/o using extra cement) in cement mortar 1:3 in roof slab complete all as specified and directed by Engir-In-Charge.
5mm thick rendering on fair faces of concrete surfaces, finished even and smooth on ceiling,roof projection,chajja in cement mortar (1:3), complete all as specified and directed by Engineer-in-Charge.
Supply for integral water proofing compound complete all as specified and directed by Engir-In-Charge.
Complete removal of existing treatment on wall surfaces and applying two coats of distemper with distemper oil emulsion over a coat of 3 mm thck wall care putty, complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint of any shade on walls over and including one coat of 3mm thick wall care putty and primer complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surfaces of walls and applying two coats of distemper with distemper oil emulsion white or tinted over including one coat 3mm thick wall care putty complete all as specified and directed by Engineer-in-Charge.
Preparation of newly plastered surfaces and applying two coats of oil bound distember over one coat of primer paint over complete all as specified and directed by Engir-In-Charge.
Preparation new decorated plastered or unplastered surfaces of ceiling applying three coat of white wash all as specified.
Two coat of cement base paint on newly plastered surfaces incl preparation of new surface all as specified and directed by Engr-in-Charge.
Two coats of cement base paint (camoflague pattern) on wall over a coat of cement base primer including preparation of surfaces complete all as specified and directed by Engir-In-Charge..
Preparation of new wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified.
Preparation of old wooden painted surfaces as exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engir-In-Charge.
Preparation of new steel and iron surfaces exceeding 10cms width or girth and applying two coats of synthetic enamel paint over preprimered surface complete all as specified.
Preparation of new or previosuly untreated wooden surfaces of any description not otherwise described over 10cm width or grith and applying two coats of S/E paint to wooden surface over one coat of pink primer complete all as specified
Taking down chowkat or frames with shutters (without taking off shutters from the frames) n.exc 1.5 Sqm each complete all as specified.
All as per item above but exceeding 1.5 Sqm and not exc 4 Sqm each complete all as specified and directed by Engir-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete , of frame size 125 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified
Pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete , of frame size 105 x 60 mm, complete all as specified
35mm thick flush shutters, solid core construction, with block board core and ply wood face pannels and both side face is covered with decorative face veneer with lipping/frame to match all as specified.
All as per item above but glazed and skeleton shutter with sash bar for wire gauge complete all as specified and directed by Engir-In-Charge.
Bands stapes supports or stays for rain water ventilating pipes, clamps hold fast confirming to Fe 290 gde E-165 complete all as specified and directed by Engir-In-Charge.
Steel window or ventilators top hung shutters including hinges, steel peg stay complete and a shop coat of red oxide zinc chrome primer , complete all as specified.
Factory made pressed steel frame steel windows (BOX TYPE) including box type hinges, steel handle, mild steel ISI marked tower bolt 100mm size (minimum 2 for each shutter)and steel peg stay, complete with glazed bars, dovetailed or welded with one shop coat of zinc chromate primer, complete all as specified and directed by the Engineer-in-Charge. Note :- Glass panes and guard brass shall be measured and paid for separately)
All as per item no above but W/O glazing bar complete all as specified and directed by Engir-In-Charge.
3 mm thick sheet glass ordinary quality & glazing with oil putty inh square n exc 0.50 sqm in each pane all specified & directed by Engr-In-Charge.
4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane, complete all specified and as directed by Engineer-in-Charge.
4 mm thick Figured glass, pin head type and glazing with oil putty in squares in not exc 0.5 sq.m in each pane complete all as specified.
Galvanized mild steel wire cloth 0.56mm normal dia of wire and average width of apparatus 1.18mm and fixed width tinned lacks of galvanized wire staple complete all as specified and directed by Engir-In-Charge.
Pre-painted galvatume aluminium zinc coating GI based corrougated steel sheeting 0.50mm thick of an colour having tensile strength of 550 MPA as in roof cavering fixed with hooks or screw complete all as specified and directed by Engir-In-Charge.
Steel in tubular trusses incding shaped washer etc complete using ERW or induction butt welded conf to IS-1161-195 grade st-240 complete all as specified and directed by Engir-In-Charge.
Framed work rolled in main raffters pulins where connected with cleat or other connecting plates complete all as specified and directed by Engir-In-Charge.
Plates sq cutor mothced with out any attachment FE-410(Gde-250 quality A) complete all as specified and directed by Engir-In-Charge.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed by Engir-In-Charge.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engir-In-Charge.
1.60 mm thk Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by Engir-In-Charge.
S&F Mild steel work such as angle iron post , flat iron in fencing including cutting as making doubble swan neck i.e. "Y" shaped including welding with proper overlapping & welding MS Plate with angle iron bottom as directed, drilling holes notching for wire etc embedded in concrete fixed vertically conforming to Fe 290 grade E-165 complete.Note : Embedded portion of Angle Iron post shall be treated with tar of coat of tar black paint. complete all as specified and directed by Engir-In-Charge.
Concertina coil with punched tape of 600 mm dia , centre core wire shall be minimum 2.5 mm dia of mild steel wire conforming to IS 280-2006. Galvanised coating of steel concertina coil shall confirm to the requirements as laid down for medium coated wire in IS 4826 "Hot dipped galvainsed coating of round steel wires" conretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil,minimum straight length of the wire 150 RM of 10 RM of work ,minimum weight 13.5 Kg for 10 RM of work i.e. 90gm per RM of wire complete all as specifed and directed.
Galvanised 2 strand , steel barbed wire 2.24mm dia barbed with 2mm barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed.(Each line wire to be measured)
Mild steel work as band straps,supports,stey hold fast and wall ties and similar small articles conforming to IS-FE 290 Gde 165. Note : Embedded portion of hold fast/wall ties shal be treated with tar of coal tar black point complete all as specified and directed by Engir-In-Charge.
MS butt hinges medium weight cold rolled 100mm long complete all as specified.
Aluninum anodised bolts barrels tower bolts with bright both 150mm long complete all as specified and directed by Engir-In-Charge.
Aluminium handle cost type 150mm long oval type complete all as specified and directed by Engir-In-Charge.
Mild steel 300mm ordinary rat tail rod pattern spring including roller and rubber plate complete all as specified and directed by Engir-In-Charge.
Mild steel sliding door bolt 300mm long plate type stove enamel black with bright bolt n.less than 12mm dia with and including minium 6 bolts and nuts four on staple plate
Mild steel barrel tower bolts stove enameled black with bright both 150 mm long complete all as specified and directed by Engir-In-Charge.
Mild steel pressed handle 150mm long oval type stove enameled black
Aluminium door stopper for doors etc, article n.exc 200 cu. cm each complete all as specified and directed by Engir-In-Charge.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed by Engir-In-Charge.
Cast iron soil waste and vent pipes, 75mm dia in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified..
Cast iron soil waste and vent pipes, 100mm dia in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified.
Cast iron soil waste and vent pipes 50mm dia in any length with or without ears with cement joints laid in trenches or in floors/walls complete all as specified.
All as per above but fixing only complete all as specified.
In repair cast iron floor trap with grating to 75mm bore including jointing to waste pipe fixed in cement concrete 1::2:4 type B-1 all as specified
Stack clamp out of 50mm by 5mm flat iron and 16mm dia round iron stays including bolts and nuts and screwing ends of stay to wall or roof of 110mm bore pipe complete all as specified and directed by Engir-In-Charge.
In repair CI bends (any radius) 100mm bore diminishing pieces or tapers all as specified .
All as per srl items No above but 75mm bore pipe complete all as specified and directed by Engir-In-Charge.
Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing.
Solid PVC Door frame of size 50mmx47mm made out of 5mm plain color PVC sheet reinforced with MS Square tube, supply and fixing in opening as per specification and drawings and incluiding making good disturbed surfaces complete all as specified and directed.
In repairs vitreous china wash down water closet pan `P` or `S` trap ( pedestal pattern ) white including fixing bolts,including connection to drain pipe ( or out going pipe) and to flushing pipe,antisyphonage pipe etc complete all as specified and directed by Engir-In-Charge.
Vitreous china wash down water closet pan `P` or `S` trap ( pedestal pattern ) white including fixing bolts,including connection to drain pipe ( or out going pipe) and to flushing pipe,antisyphonage pipe etc complete all as specified and directed by Engir-In-Charge..
Plastic water closet seat cover ,white/ black,closed pattern with flats bottom and cover and mild steel chromium plated or aluminium hinging device,of approved make and quality etc complete all as specified and directed by Engir-In-Charge.
Viterous china Urinals, half stall large coloured make CERA including connection PVC waste pipe of adequate dia and size CP grating with hole and urinal spreader with PVC connection make "jaquar" including fittings fixed in repair complete all as specified & directed by Engr-In-Charge.
In repair 10 Ltr PVC valveless syphonic action type flushing cistern low level white with inlet including bracket and 32mm flush pipe of polythylene ball valve,float and handleof low or high density and 15mm PVC connection 450mm long complete all as specified and directed by Engir-In-Charge.
PVC valve less syphonic action type flushing cistern 10 Ltr capacity low level coloured with inlet ball valve float and handle brackets all as fixed in repair all as specified & directed by Engr-In-Charge..
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
In repairs PVC bathroom cabinets quality as approved by Engr-in Charge, of size 600mmx400mm with miirror on front door and with one towel rail for hanging towel of MS chromium plated fixed with screw and wooden gutties etc complete all as specified and directed by Engir-In-Charge.
Seperating scraping of iron complete all as specified and directed by Engir-In-Charge.
In repair Viterous china wash basin, counter type, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP getting with holes complete all as specified and directed by Engr-in-Chare.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware complete all as specified and directed by Engr-in-Charge .
Cast copper alloy, chromium plated central hole basin mixer non telephonic, without pop-up system, suitable for 15 mm bore pipe, FIXED IN REPAIR, with service pipes, complete all as specified and directed by Engineer-in-Charge.
PVC connection 15mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engir-In-Charge.
In repairTowel rail 600mm long aluminium tower bolts 20mm D type all as specified
In repair Soap dish chromium plated fancy type fixed with bress screws and wooden/plastic cleats complete all as specified.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm/20mm dia.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm bore all as specified.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore all as specified.
In repair stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 25mm dia complete all as specified and directed by Engir-In-Charge.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 15mm dia complete all as specified and directed by Engir-In-Charge.
In repair Angle cock cast coper alloys, 15mm dia, chromium plated with capaston head and long shank etc fixed in repair for 15mm bore pipe, complete all as specified.
Pillar taps cast copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed of iron pipe of bore 15mm complete all as specified & directed by Engr-In-Charge.
In repair 15mm Bib taps, cast copper alloy, fency type chromium plated, with crtuch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engir-In-Charge.
In repair Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I,capacity of water tank 1000 Ltr complete all as specified and directed by Engir-In-Charge.
Ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule & fixed complete all as specified and directed by Engir-In-Charge.
Priming the roof surface with bitumenous primer @ 0.3 litres/Sqm and applying a coat of semi hot blown 85/25 grade bitumen @ 1.2 Kg/Sqm and thereafter supply and laying polymeric membrane, five layered, of weight not less than 3 Kg per Sqm with centre layer core of 90 micron high molecular density polyethylene film and bonded completely to the osurface with overlap of 10cm (overlap to be thermo fused by flame) followed by another coat of semi hot blown 85/25 grade bitumen @ 0.7 KgSqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm including two coats of alumn paint all as specified and as directed.
Taking down carefully point wiring copper/aluminium (light, fan, socket, and power) complete (fittings such as switches ceiling roses, pendent regtulators sockets etc to be measured and paid for separately removing materials to store for keeping of safe custody and making good the disturbed surfaces complete all as specified and as directed.
Point wiring with 1.5sqmm PVC insulated unsheathed FRLS cable with multistaranded copper conductor anodised sunken boxs in and incl nonmetallic rigid PVC grade ISI marked PVC surface conduit wiring with vailedC/ML No with all accessories for one light/fan/bell point controlled by one switch with thickness not less than 1.25mm MS terminal boxes concealed on wall with and including 3mm thick laminated backlite sheet including 1.5sqmm PVC insulated unsheathed FRLS cable with multistranded copper conductor continuous earth wire connected to common earth and duly complete all as directed by Engineer-in-charge..
All as per item No 140 above but for one 3/5 pin socket 5 Amp on same board, with cable1.5sqmm size.
All as per item No 140 above but for one 3/5 pin socket 5 Amp on independent board with cable1.5sqmm size.
All as per item No 140 above but for 3 pins socket outlet 15 Amps independent with 2.5 sqmm incl continous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
All as per item No.140 above but controle by 2 Nos.of two way switch.
Switch socket combination 2 in 1, 3 Pin, 5 Amp flush type universal complete all as specified and directed by Engir-In-Charge.
Switch socket combination 2 in 1, 3 Pin, 5 and 15 Amp flush type universal complete all as specified and directed by Engir-In-Charge.
Socket outlet 2 in 1, 3 Pin, 5 Amp flush type universal complete all as specified and directed by Engir-In-Charge.
Switch 5 Amps flush type 230 Volts , AC complete.
Electronic step type regulator of capacity 240 volts flush type complete all as specified and directed by Engir-In-Charge.
Ceiling rose, surface backlite, 65x50mm, three terminals complete all as specified and directed by Engir-In-Charge.
Submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRSL sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC Concealed Conduit as per site requirement including taking down old us submain wiringand direction by EIC, all accessories complete all as specified and directed.
Sub main wiring with 2 single core PVC insulated unsheathed stranded copper conductor cable of Size 4 Sqmm with and including PVC CONCEALED CONDUIT "ISI" marked with all fittings and accessories and one single core PVC insulated solid copper conductor cable 4.0 sqmm as contineous earth wire and connected to earth dolly including taking down old us submain wiring all as specified and directed.
In replacement Distribution board 4 way TP&N Double Door IP43-IK09 with metal door are fitted with Bus Bars, Neutral Links suitable for 415V, 50Hz, Blanking Plates, Suitable for TP/FP MCB complete all as specified and directed by Engir-In-Charge.
Single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways complete all as specified and directed by Engir-In-Charge.
C' series SPN MCB 40 to 63Amps 240V ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc complete all as specified and directed by Engir-In-Charge.
'C' series SP MCB 06 to 32 Amps 240V ,50Hz,10kA suitable for lighting and other domestic loads incl all termnials, fitting etc.
Replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity complete all as directed.
Decorative ultra slim square profile LED lighting fixture 05 Watt with extruded polycarbonate, environmental friendly, energy efficient ready to use pack including taking down old US tube light fitting 1x36W and taken in schedule of credit all as specified and as directed by engineer incharge of Make : Havells Cat No : LHEXBTP7IN1W005 or equivallent in any MES approved make subject to sample approve by ACCEPTING OFFICER
Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old US tube light fitting 1x36W and taken in schedule of credit all as per the direction of Engr-in-Charge. Make -Make model of Havells cat No LHEXCEP7UN1W020 or equivallent in any MES approved make subject to sample approve by ACCEPTING OFFICER
Security (street) light fitting 25 watt, new generation energy saving & environmental friendly long life versatile pressure die cost aluminium IP 66 with acylic, powder coated, pressure die cast aluminium compact high power LED street light with heat resistant toughed glass, corrosion resistant, isolated driver, including provision of GI tubing bracket of suitable size and fixed on wall including clamps, nut, bolts and washer for fixing of security (street) light completet including taking down old US light fitting of any type /size and taken in schedule of creditall as per direction of Engr-in-Charge. Make:SYSKA Cat no SSK-ST-25W(S) or equivallent in any MES approved make subject to sample approve by ACCEPTING OFFICER
Supply and hanging ceiling fan of 1200 mm sweep, white in colour , of including all electric connection and step type electronic fan regulator, provn of hanging arragement and testing complete Make : Havells cat No : ES-50 Premium/Standard model- Breezer metalic finish pearl white /Bajaj Leatrim all as specified and directed by Engr-in-charge.
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing complete all as specified and directed by Engir-In-Charge.
Dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt complete all as specified and directed by Engir-In-Charge.
GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia complete all as specified and directed by Engir-In-Charge.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below Normal ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised earth lead wire 4.0mm dia by means of GI nuts, bolts and washers of galvanised iron or steel all as shown in electrical plate no.5 connecting to earth test point all as specified or indicated including testing on complition with following:- (a) Test point GI wire 4mm dia . (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover (d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover.
Earth continuity conductor or main earhing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire .
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
Repair of ceiling fan/exhaust fan 1200mm/300mm sweep of any make obtained from above item, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc including painting. If as per site requirement fan will be found burnt rewinding will be provide by the contractor as per unit quoted rate all as specified and directed by Engr-in-charge.
Hanging /fixing only ceiling fan/Exhuast fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 170 complete all as specified and directed by Engir-In-Charge.
In replacement E-Lite LED Curve lighting fixture for mirror 12 watt LED batten,T5 with full base of extruded Aluminium body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old unserviceable tube light fitting 1x 18 watt from the site reuse to measured seprately or disposal by credit all as per the direction of Engr-in-Charge. Make -Havells as per ordering code LHEXBYPNIN1W010 or equivallent in any MES approved make subject to sample approve by ACCEPTING OFFICER
MCB TPN 63 Amps four pole 415V incl all termnials, fitting etc complete all as specified and directed by Engir-In-Charge.
Supply fixing connection and testing MCB SP 40 Amps 'C' Curve all as specified and as directed by engineer incharge
Switch Piano, flush type, two way, single pole, 5 Amps, suitable for 240 V, 50 Hz, AC supply complete all as directed by Engineer- in - Charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .