Loading…
Loading…
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
29 Jun 2026, 3:00 pm
Electrical work in connection with [1] Replacement of old/Dilapidated quarters of Traffic quarters Type-II-1, Type-III-7 and Type-IV-01 at BWL and Type-III-02 at AIA and Type-III-3 at KRH (Total 14 units), [2] Providing staff quarter Type II-12 nos. and Type III-04 nos. at AWR Total 16 nos, [3] Providing staff quarters Type-II 12 nos and Type-III 04 nos at RE Total 16 nos, [4] Replacement of old/Dilapidated quarters of Traffic quarters Type-II 14 and Type-III 06 nos. at BKI (Total 20 Units), [5] Construction of new quarters for staff at DGW, BAI Type-II (08 units), - III (05 units) & Type-IV (02 units) Total-15 units, [6] Replacement of old/dilapidated quarters at RE, KRH, AWR stns. Type-II (12 units), Type-III (05 units) & Type-IV (02 units) - Total (20 units), [7] Construction of New building for 20 bedded indoor unit of Sub Divisional Hospital Rewari.
EL-JP-08-2026-27
EL-JP-08-2026-27
Open
12 Months
Rewari, Haryana
₹0
₹2.1 L
4 Jun 2026
4 Jun 2026
15 Jun 2026
Description:- Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5sqmm PVC single core
with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (MODULAR) as per spec
PVC CU cable as per spec.
connection as per spec
4 Description:- Supply and fixing ceiling of fan regulator electronic type 5-step as per spec
quality concealed fixing of MS/PVC
quality concealed fixing of MS/PVC JAIPUR DIVISION-ELECTRICAL/NORTH WESTERN RLY
quality concealed fixing of MS/PVC
quality concealed fixing of MS/PVC
copper wire in PVC conduit concealed and 1.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec
wire in PVC conduit concealed and 1.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec
wire in PVC conduit concealed and 2.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec
connection as per site requirement as per spec
connection as per spec
14 Description:- Supply and Providing GI Pipe Earthing of 4meter length as per spec
15 Description:- Supply and fixing of PVC meter box with 2 Nos. single pole MCB 6-32A as per spec.
16 Description:- Supply and fixing of electronic energy meter 0-30A or above as per spec.
fixing and sheet metal enclosure box with one 20A plug top (Ray roll type) to be supplied with board as per spec.
leakage, overload and short circuit protection as per spec
phase, DP MCB and outgoing 8Nos. single pole MCB 6-16A as per spec
copper wire with board as per spec
kuchha/pucca and land and all type of soil as per site requirement and without protective layer of brick) surface of trench shall be made good in all respect and satisfaction of site engineer
23 Description:- Laying of LT/HT Cable IN AIR / Pipe/ Wall/tray as per spec
pole MCB 63A as per spec
leakage, overload and short circuit protection as per spec
26 JAIPUR DIVISION-ELECTRICAL/NORTH WESTERN RLY 26 Description:- Supply, fixing, testing and commissioning of Distribution Board double door, 3-phase and neutral with incoming 63A 4-pole MCB and outgoing 12Nos. MCB 6-32A single pole as per spec.
quality concealed fixing of MS/PVC
made of MS sheet 1.6mm thick size 600x300x600mm with suitable MS stand Copper bus bar of 200A capacity and 2x63A MCB 4 pole as per spec
base plate with fixing of 1No. arms 1000mm for the fittings including smart pack junction box with 6A MCB and terminals as per spec.
31 Description:- Supply and laying of Electrical copper cable 2.5 sqmm/ 3 core
thickness 3 mm PN-4 under the road/air. The work invloves laying of HDPE pipe.
Description:- Horizontal Directional Drilling (HDD)/Boring and trenchless cabling. Supply, transportation and insertion of self lubricated HDPE pipe and laying of cables in boring under the
103.5mm inner dia in the bore and laying of cables in the bore under the track/road/ground/masonary building. The depth of horizontal boring should be minimum 1 mtr from rail flange/road level/ground, as per site requirement.
MCCB incoming supply and outgoing of 2x100A MCCB and 2x63A MCCB with meters, switchgears, indication lamp etc as per spec
KOS 225M or similar with control panel consisting 16A MCB A-meter, V-meter indication lamp complete in all respect including connection with cable of adequate size as per railway requirement.
site as per spec
phase, 415V AC with all accessories at site as per spec
copper cable etc as per spec
valve and supporting clamps (2 sets) etc. as per spec
three-phase pump including connections and providing cable from main board to control panel and connection for WLG in open well as per spec.
clamps, nut-bolts etc as per spec.
42 Description:- Supply and laying of copper flat cable size 3x6sqmm as per spec
Description:- Supply fabrication fixing and installation of MS sheet steel enclosure free standing
of 16swg sheet size 120x70x60cms with painting and locking arrangement and foundation with installation of automatic control panel inside the box as per spec. JAIPUR DIVISION-ELECTRICAL/NORTH WESTERN RLY
44 Description:- Supply, fixing, testing and commissioning of 40A MCCB 4 pole as per spec
45 Description:- Provision of capacitor 5KVAR as per spec
46 Description:- Supply, fixing and connecting modular type exhaust fan 225/250mm as per spec
600x600x3mm as per spec.
48 Description:- Supply and fixing of Copper Earth Flat strip size 25x3mm as per spec
and 4x100A MCCB with A&V meter selector switch indications etc as per spec
water connection angle valve as per spec
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
I_CT_GCC-
ATTACHMENT
Advance Correction Slip No 1 to 11
ATTACHMENT
ESTD-08-2026-27.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
AdvanceCorrectionSlipNo1to11GCC-2022_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid