| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC 3 1ST FLOOR SRINIDHI BUILDING SM ROAD T DASARAHALLI BANGALORE 560 057 | BENGALURU URBAN | KARNATAKA | 560057 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.6 L+₹47,161 (5.81%)Rejected-Finance 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹8.8 L+₹72,623 (8.95%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹10.4 L+₹2.2 L (27.7%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹10.6 L+₹2.5 L (30.3%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
26 Jan 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Shubham yadav,AEE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
MAINT AND REPAIR TO EXTERNAL ELECTRIC SUPPLY NETWORK AND CONNECTED WORKS AT NO 2 AFSB MYSORE UNDER AGE I AF CHIMNEY HILLS
2023_MES_634553_1
8670/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I AF CHIMNEY HILLS BANGALORE
as per tender documents
8 documents required · 8 mandatory
₹500
Yes
AGE I AF CHIMNEY HILLS BANGALOR
₹18,000
Yes
1 Apr 2024
9 Jan 2024
27 Jan 2024
9 Jan 2024
26 Jan 2024
19 Jan 2024
9 Jan 2024 - 15 Jan 2024
Amount
Supply and lay LT under ground cable XLPE insulated armoured heavy duty 1100V grade with multistranded/solid aluminium conductor confirming to relevant IS in trenches, ducts, through pipes fixed to wall etc all as directed including cable gland, terminal socket and connecting up of size 240 sqmm 3.5 core including dismantling of old U/S cable
All as per item ser No 1 above but of size 70 sqmm 3.5 core
All as per item ser No 1 above but of size 35 sqmm 3.5 core
All as per item ser No 1 above but of size 25 sqmm 4 core
All as per item ser No 1 above but of size 16 sqmm 4 core
All as per item ser No 1 above but of size 10 sqmm 2 core
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/repair of cable.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Supply and lay brunt bricks class 'B' of standard size in trenches for protection of UG cable.
M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified
Supply and lay GI tubing light grade, 80mm dia in trenches for road crossing/laid in floors etc
All as per item ser No 12 above but 50mm dia
All as per item ser No 12 above but 25mm dia
Supply, Laying and Testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 3 Core, 95 Sqmm.
Supply, jointing and testing out door type HT cable end termination joint "push on type" heat shrinkable suitable for aluminum conductor XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, and over all PVC sheathed cable 11000 volts grade 3 core 95 sqmm nominal size all as directed.
Supply and joint Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified anf directed.
Taking down carefully the transformer from four pole and two pole structure, platform,transporting the transfromer to workshop and draining out the transformer oil in clean barrels, opening the top cover of the transformer oil, disconnecting the electrical connection, taking out the core/winding coils out of the tank, taking the defective/burnt out HT/LT coils, cleaning the tank and cleaning out the dust particles, refitting the core in the tank after necessary repairs (repair shall be measured and paid separately) and heat treatment, connecting all the electrical connections, refitting the top cover and other accessories and making the transformer absolutely leak proof, pouring in the insulating oil in the transformer, before installation all test should be carried out ic load test , insulation test, Di- electric strength test satisfactory and transporting the transformer and back to same placing in position and securing properly on 4 pole/2pole structure/platform at site and making all HT/LT connections installation,testing and commissoning complete all as specified and directed by Engineer-in-Charge for the following capacities (The rates are inclusive of transportation of transformer from site of installation to workshop and back including T & P reqd and all the HT/LT winding will be measured and paid separately.) :-(a) 100 KVA to 200 KVA.
Ditto all as above item no 17 but for 200 KVA to 315 KVA.
Rewinding of complete/Partly HT coils with super enamel copper conductor of appropriate gauge alongwith allied material as already used in the transformer complete all as specified and directed suitable for transformer of capacity 25 KVA but not exceeding 150 KVA.
Rewinding of complete/Partly HT coils with super enamel copper conductor of appropriate gauge alongwith allied material as already used in the transformer complete all as specified and directed suitable for transformer of capacity Exceeding 150 KVA but not exceeding 300 KVA.
Rewinding of complete/Partly LT coils with super enamel copper conductor of appropriate gauge alongwith allied material as already used in the transformer complete all as specified and directed suitable for transformer of capacity 25 KVA but not exceeding 150 KVA.
Rewinding of complete/Partly LT coils with super enamel copper conductor of appropriate gauge alongwith allied material as already used in the transformer complete all as specified and directed suitable for transformer of capacity Exceeding 150 KVA but not exceeding 300 KVA.
Taking out the transformer oil sample from distribution/isolation transformers, indoor/outdoor type and testing the oil for dielectric strength/moisture content complete all as specified and directed by the Engr-in-Charge
Filtration, heating and dehydration of transformer oil (at site)on load system, EHV grade having dielectric strength not less than 55 KV (RMS) with 2mm gap high viscosity in transformer of cap 25 KVA to 300 KVA as per IS-335 of 1983. The reducing of moisture, acidity carbon particle in transformer oil. Note :- The filtration, heating and dehydration of transformer oil shall be carried out at site. The unit rate quoted by the contractor shall deemed to include for arrangement of filtration machine and its transportation to various locations of installation of transformer and Toping up of Transformer oil.
Supply only Transformer Oil of Di-Electric strength 55 KV 4 mm gap of discharge 2 sec for topping up of transformer all as Specified and directed by Eng - in - Charge.
Material and labour preparation of existing treated steel structure, angle Iron of GODs/Two pole/four pole structures and painting the same with one coat of aluminium paint all as directed.
Material and labour one coat of grey/half white colour synthetic enamel paint after preparation of surfaces of existing LT panels/control switch boxes over 10 cm in width or girth complete all as specified and directed
S/F in repair current transformer coil ratio up to 800/5 Amps Class-1 insulation. Make:GEC/MEI/Crompton
Supply and fix phase LED indicator lamp with toggle switches including taking down of fused indicator lamp.
Supply and fix 0-500 volts Voltmeter including taking down unserviceable voltmeter as directed. Make: AE/MECO
Supply and fix Ammeter 0-400 Amp including taking down unserviceable ammeter .Make: AE/MECO
Supply and install in repair MCCB, 4 pole, 415 v, adjustable type, 400 Amp, 50 HZ, 36 KA including spreader links on both sides complete all as specified and directed
All as per item no.26 above but fixed type, 25 to 100 A and 16 KA
All as per item no.26 above but fixed type, 125 A and 16 KA
All as per item no.26 above but adjustable type, 200 A and 36 KA
All as per item no.26 above but adjustable type, 250 A and 36 KA
M&L earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground earth pit not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6mm as a earthing lead by means of bolts, nuts, checks nuts, washers etc made of galvanized of steel, earth strip including and protected by galvanized iron pipe(light grade) 40 mm dia from plate to Panel Board, galvanized iron pipe light grade 20mm dia bore and funnel watering including test point necessary excavation ,earth work, concrete pit M-10, CI cover, frame and funnel, all as specified in plate No 3 of SSR-1991(part-1) complete all as specified and as directed.
M&L earthing complete with using copper plate 60×60cm ×3.15mm thick electrode buried directly in ground earth pit not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below normal ground level, connected to and 20×3mm copper strip as a earthing lea by means of bolts, nuts, checks nuts, washers etc made copper strip, earth strip including and protected by galvanized iron pipe(light grade) 40 mm dia from plate to Panel Board, galvanized iron pipe light grade 20mm dia bore and funnel watering including test point necessary excavation ,earth work, concrete pit M-10, CI cover, frame and funnel, all as specified in plate No 3 of SSR-1991(part-1) complete all as specified and as directed.
M & L for checking for resistance of existing earthing pits connected to panels/eqpts by disconnecting earth lead and after testing and result obtaining same to be re-connected as vice versa complete all as specified and directed.
SREE VINAYAKA ENTERPRISES
AMK ENTERPRISES
ANAND REFRIGERATION
H S S ENGINEERS AND CONTRACTORS
KUZHIKKAL ENTERPRISES
M/S AMRITHESH ENTERPRISES
SAPTHAGIRI CONSTRUCTIONS
Aditya Associates
Lucky Enterprises
ARCHANA CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .