Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC 37 2 KARUMALAIKODA CHINNAIYA REDDY STREET METTUR R S PO 636 402 | METTUR | SALEM | TAMIL NADU | 636402 | L1 | Accepted-AOC l1 |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
18 Nov 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE/MEDC/Mettur
O/o SE/MEDC/Mettur
works for effecting services in various schemes in Pappampady section in Omalur division
2023_EB_385781_1
SE/MEDC/AEE/MM/MTR/Spec No.030/23-24
Open Tender
Electrical Works
Works
365 days
SE/MEDC/Mettur
EMD and documents as per BQR conditions
2 documents required · 2 mandatory
₹0
₹15,000
30 Dec 2023
4 Nov 2023
18 Nov 2023
4 Nov 2023
18 Nov 2023
4 Nov 2023
4 Nov 2023 - 18 Nov 2023
Amount
Work contract schedule
Excavation of pole pit upto 27" (8.0 m ) Pole by using JCB or manual
Excavation of stay pit 4.5' to 5' depth by using JCB or manual
Excavation of pole pit above 8.0 Mtr pole PSC/RCC/RSJ pole by using JCB or manual
Erection of Stay set complete
Hard rock requires blasting
Hard rock without blasting (where houses are located)
Erection of PSC/ RCC poles/Metal poles upto 8.00m. (27') by using JCB or manual
Erection of PSC/ RCC poles/Metal poles above 8.00m by using JCB or maual
Fixing of HT/LT TI Fittings
Fixing of HT "V" cross arms (all types) / Channel cross arms/ Guarding
Fixing of HT pin Insulators 22 KV
Fixing of HT 11 KV strain disc.
Fixing of LT Single phase cross arms
Fixing of LT 3 phase cross arms
Fixing of LT pin Insulator
Fixing of LT shackle
Fixing of Aluminium Knob
Paving of Conductor, stringing etc., complete with ACSR/ AAAC for both HT/LT lines. ACSR 7/4.09 mm Raccoon conductor
Paving of Conductor, stringing etc., complete with ACSR/ AAAC for both HT/LT lines. ACSR 7/3.35mm / AAAC 3.15 mm Rabbit conductor
Paving of Conductor, stringing etc., complete with ACSR/ AAAC for both HT/LT lines ACSR 7/2.59 mm / AAAC 2.50 mm weasel and ACSR 7/2.11 mm
Sleeve concreting including materials (Cement + River Sand/ M sand and Blue metals and watering)
Transport of poles/Materials/ conductors and other materials (excluding loading and unloading charges.) Below 8 Kms (Plains)
Loading of materials
Unloading of materials
Loading of poles/ Materials etc.Loading of poles upto 8.0 M/ 27'
unloading of poles/ Materials etc.Loading of poles upto 8.0 M/ 27'
Transporting of poles from road side to pole pit including loading and unloading of poles by using JCB or manual up to 100 m
Transporting of poles from road side to pole pit including loading and unloading of poles by using JCB or manual beyond 100 m
Labour charges for alteration of Back Clamps
Labour charges for alteration of Stay Clamps
Drilling of hole in channel only 3/4" & 1"
Cutting of flat
Cutting of channel
Feeder arrangements with open type fuse unit for 1 feeders
Earthing of pole with coil earthing including burying looping and binding.
Dismantling PSC/ RCC poles/Metal poles 8.00m.
Releasing of grills from RCC Pole
Releasing of 3 phase service and (upto 50 HP) re-fixing.
Releasing of single phase service and re-fixing.
Dismantling HT "V" cross arms
Dismantling of HT pin Insulators 22 KV
Dismantling of HT 22 KV strain disc.
Dismantling of LT Single phase cross arms
Dismantling of LT Three phase cross arms
Dismantling of LT Shackle
Dismantling of LT Pin Insulators
Dismantling of Alu Knob
Dismantling of Stay set
Re-sagging ACSR 7/2.59 mm / AAAC 2.50 mm Weasel and ACSR 7/2.11 mm conductor
Re-sagging ACSR 7/3.35mm / AAAC 3.15 mm Rabbit conductor
Erection of Single Pole Transformer structure complete in all respects with wiring, Earthing, fixing of open type fuse units, HT/LT LAS and jumpering 3 Nos. Earth pit with collar including painting of metal parts, structure poles, fixing of tapping channel, transformer bed structure including concreting (Except erectionof Transformer)
Erection of Transformer structure complete in all respects with wiring, Earthing, fixing of open type fuse units, HT/LT LAS and jumpering 3 Nos. Earth pits with collar including painting of metal parts, structure poles, fixing of top channel, seating channel, belting angle including concreting (Except erection of Transformer)
Loading or unloading of Transformer above 100 and upto 200 KVA
Erection of New Transformer all capacities (with jumpering)
G.S.T. @18% should be Entered by the Bidder
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .