Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.2 LAccepted-AOC S1 AMBIANCE BELA VISTA NEAR OMEGA ICE PLANT CHICALIM VASCO DA GAMA GOA 403711 | SOUTH GOA | GOA | 403711 | ₹64.2 L | L1 | Accepted-AOC Accepted Being L1 Bidder |
| 2 | L2₹68.2 L+₹4.0 L (6.24%)Rejected-Finance GOA GOA | SOUTH GOA | GOA | 403715 | ₹68.2 L+₹4.0 L (6.24%) | L2 | Rejected-Finance Rejected Being L2 Bidder |
Tender Value
₹67.2 L
EMD Value
₹1.3 L
Closing Date
18 Jun 2026, 11:00 amClosed
Executive Engineer DIV VIII ASW PWD Fatorda
Executive Engineer DIV VIII ASW PWD Fatorda
Urgent repairs and maintenance work at Sub District Hospital Chicalim in Dabolim Constituency.
2026_PWD_29688_1
PWD/Div8/ASW/2001/09/26-27/L1
Open Tender
Civil Works - Buildings
Percentage
180 days
Fatorda
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Yes
₹1.3 L
Yes
6 Jul 2026
11 Jun 2026
22 Jun 2026
11 Jun 2026
18 Jun 2026
11 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and fixing
vitrified matt finished
(600x600) and 10mm thick
tiles in floor treads of steps
landing on 25mm thick bed
of cement mortar 1:3 and
jointed with cement slurry
complete. | - | sq.m | - | - |
| 2 | Providing and fixing 18
mm thick gang saw cut
mirror polished
premoulded and
prepolished machine cut
for kitchen platforms
vanity counters window
sills facias and similar
locations of required size
approved shade colour and
texture laid over 20 mm
thick base cement mortar 1:
4 (1 cement : 4 coarse
sand) joints treated with
white cement mixed with
matching pigment epoxy
touch ups including
rubbing curing moulding
and polishing to edges to
give high gloss finish etc.
complete at all levels.
Granite of any colour and
shade area of slab over
0.50 sqm;Jet Black | 1 | sq.m | - | - |
| 3 | Providing and fixing Kota
stone tread tiles 35mm
thick in single piece with
rounded of nosing antiskid
groove laid on and
including 20mm (average )
thk bed of cement slurry
including pointing with
pigmented cement slurry to match the shade of the slab
cleaning etc. complete. | - | sq.m | - | - |
| 4 | PVC false ceiling grid type : Providing and fixing PVC False Ceiling consisting of 600mm x 600mm, 5mm(±0.25) thick Plain PVC sheet of 600 kg/Cbm Density Manufactured by an ISO-9000 certified Company, used as panel insert in a frame work made using anodized aluminum T- section of sizes 1” x1” (25x25mm, 19 gauge or 1mm thick) in square pattern of grid sizes of 2’x2’(600x600mm). The aluminum frame work is supported from the ceiling with the help of 'J' hook and G.I. wire / 6mm M.S. rods of required sizes to maintain proper level etc. The aluminum framework is supported on side wall with the use of aluminum L-section of size 1”x1” (25x25mm) angles etc. Complete as per direction of Engineer-In-charge, manufacturer’s specification & drawing. | - | sq.m | - | - |
| 5 | Providing and fixing 15mm thick densified tengular edged eco friendly light weight Calcium Silicate false ceiling tiles (like Aerolite Brand or Equivalent) of approved texture Spintone/ Cosmos/ Fine Fissured or equivalent of size 595mm x 595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @ 120 grams per square metre. including both side) consisting of main "T" runner suitably spaced at joints to get required length and of size 24x38mm made from 0.33mm thick (minium) sheet, spaced 1200mm center to center, and cross "T" of size 24x28mm made of 0.33mm thick (Minimum) sheet to be inter locked at middle of the 1200x600mm panel to from grid of size on a Perimeter wall angle precoated steel of size 600x600mm, resting on periphery walls/ partitions (24x24x300mm) made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm and laying 15mm thick densified edges calcium silicate ceiling tiles of approved texture light fittings, fixture, smoke detectors etc., wherever required. Main "T" runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6mm fixed to celing using with 12.5mm dia and 50mm long dash fastners, level clips of size 85x30x0.8mm, spaced at 1200mm center to center along main "T" bottom exposed with 24mm of T-section shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings etc. complete. (As Directed by Engineer in Charge) Note: Only Calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having are less than 0.30 sqm. The Calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection>85% non-combustible as per B.S.476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/m 0 KC.Hospitals, Offices and Commercial Buildings, Auditoriums and Cinema Hall, Educational Institutions, R&D Centers, Studios, Laboratories, Library, Canteen. | 1 | sq.m | - | - |
| 6 | Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | 1 | sq.m | - | - |
| 7 | Waterproofing of sunken slabs, toilet blocks, terraces on slabs under brickbats, roofs, watertanks. Cleaning the surface and filling cracks (if any), applying EPCO ACR wherever necessary, Providing and Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in the ratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12 hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure with sprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent | 1 | sq.m | 691 | ₹690.31 |
| 8 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 1 | sq.m | - | - |
| 9 | Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. | 1 | sq.m | - | - |
| 10 | Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. | 1,572 | sq.m | 1,029 | ₹16,17,588 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tendernotice_2.pdf
PDF • 1.00 MB
BOQ_30112.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .