Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC 54 SATYEN BOSE ROAD DESHBANDHUPARA SILIGURI 734 004 | JALPAIGURI | WEST BENGAL | 734004 | ₹47.4 L Quoted ₹48.5 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹48.7 LRejected-Finance SIMULBARI T E PO VILL SIMULBARI PS KURSEONG DIST DARJEELING PIN 734009 WEST BENGAL | SIMULBARI | DARJEELING | WEST BENGAL | 734009 | ₹48.7 L | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹48.7 LRejected-Finance NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | ₹48.7 L | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹49.7 LRejected-Finance EAST VIVEKANANDA PALLY MANGAL PANDEY SARANI PO RABINDRA SARANI SILIGURI 734 006 WB | JALPAIGURI | WEST BENGAL | 734006 | ₹49.7 L | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹49.7 LRejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 HQ 136 WE | JALPAIGURI | WEST BENGAL | 734001 | ₹49.7 L | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | ELECTRO WIR WAY L9 | MS ESSCON L7 | MS ORIENT ENGINEERING WORKS L8 | PS ENTERPRISE L4 | R N SAH N CO L2 | M/s TRIMURTI ASSOCIATE L6 | SHRI N.DAS L5 | M/S G S ASSOCIATES L1 | Janata Enterprises L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Carrying out “A” Check maintenance of serviceable DG Sets as per manufacturer’s instruction and as given below for 7.5 KVA to 82.5 KVA, all available DG Set in Power House and Pump House at U area in Sukna Mil Stn complete all as specified and as directed.
NOTES:-
i) "A" check maintenance shall include:-
a) Checking of oil level
b) Checking cleaniness of DG set and cleaning the same
c) Checkng battery voltage
d) Checking any leakage
e) Checking all filter condition
f) Checking coolant level
g) Checking 'V' belt condition
ii) DG set of any capacity as and when required to be maintained. | 5 | Each Job | 3,600 ₹18,000 | 3,580 ₹17,900 | 3,510 ₹17,550 | 3,680 ₹18,400 | 4,250 ₹21,250 | 3,510 ₹17,550 | 3,510 ₹17,550 | 3,050 ₹15,250 | 3,100 ₹15,500 |
| 2.00 | Carrying out “B” Check maintenance of serviceable DG Sets as per manufacturer’s instruction and as given below (after running of 250 to 300 Hours) for 7.5 KVA and 50 KVA DG Set complete all as specified and directed.
NOTES:-
i) "B" check maintenance shall include:-
a) Changing of oil
b) Changing oil filter, fuel filter, bypass filter & gasket
c) Changing Air filter
d) Removing water from water separator
ii) Supply only spares, components, engine oil etc, for carrying out “B” check maintenance shall be measured and paid separately. | 1 | Each Job | 7,600 ₹7,600 | 7,675 ₹7,675 | 7,500 ₹7,500 | 7,880 ₹7,880 | 7,950 ₹7,950 | 7,510 ₹7,510 | 7,507 ₹7,507 | 9,550 ₹9,550 | 9,550 ₹9,550 |
| 3.00 | Carrying out “B” Check maintenance of serviceable DG Sets as per manufacturer’s instruction and as given below (after running of 250 to 300 Hours) for 50 KVA and 82.5 KVA DG Set complete all as specified and directed.
NOTES:-
i) "B" check maintenance shall include:-
a) Changing of oil
b) Changing oil filter, fuel filter, bypass filter & gasket
c) Changing Air filter
d) Removing water from water separator
ii) Supply only spares, components, engine oil etc, for carrying out “B” check maintenance shall be measured and paid separately. | 4 | Each Job | 13,000 ₹52,000 | 12,790 ₹51,160 | 12,600 ₹50,400 | 13,135 ₹52,540 | 14,800 ₹59,200 | 12,510 ₹50,040 | 12,508 ₹50,032 | 16,800 ₹67,200 | 16,900 ₹67,600 |
| 4.00 | Carrying out “C” Check maintenance of serviceable DG Sets as per manufacturer’s instruction (after running of 800 to 1500 Hours) for 7.5 KVA to 50 KVA DG Set complete all as specified and as directed.
NOTE:-
i) "C" check maintenance shall include:-
a) Changing of oil
b) Changing oil filter, fuel filter, bypass filter & gasket
c) Changing Air filter
d) Removing water from water separator
e) Cleaning of radiator with chemical incl supply of
chemical
f) Checking of all electrical terminals & thimbles
g) Engine injector setting
h) Changing gasket for piston head
ii) Supply only spares, components, engine oil etc, for carrying out “C” check maintenance shall be measured and paid separately.
iii) Make: Kirloskar Cummins | 1 | Each Job | 34,000 ₹34,000 | 34,280 ₹34,280 | 33,600 ₹33,600 | 35,200 ₹35,200 | 33,000 ₹33,000 | 33,510 ₹33,510 | 33,508 ₹33,508 | 32,800 ₹32,800 | 31,800 ₹31,800 |
| 5.00 | Carrying out “C” Check maintenance of serviceable DG Sets as per manufacturer’s instruction (after running of 800 to 1500 Hours) for 50 KVA to 82.5 KVA DG Set complete all as specified and as directed.
NOTE:-
i) "C" check maintenance shall include:-
a) Changing of oil
b) Changing oil filter, fuel filter, bypass filter & gasket
c) Changing Air filter
d) Removing water from water separator
e) Cleaning of radiator with chemical incl supply of
chemical
f) Checking of all electrical terminals & thimbles
g) Engine injector setting
h) Changing gasket for piston head
ii) Supply only spares, components, engine oil etc, for carrying out “C” check maintenance shall be measured and paid separately.
iii) Make: Kirloskar Cummins | 4 | Each Job | 39,000 ₹1.6 L | 39,140 ₹1.6 L | 38,250 ₹1.5 L | 40,190 ₹1.6 L | 38,100 ₹1.5 L | 38,255 ₹1.5 L | 38,259 ₹1.5 L | 38,900 ₹1.6 L | 38,500 ₹1.5 L |
| 6.00Supply only the following spares as per existing make all as directed :- | ||||||||||||
| 6.01 | Engine oil 20 W 40 / 10 W 40 Grade.
Make:- Servo, Castrol, HP, Indian Oil Ltd., Bharat Petroleum | 130 | Litre | 420 ₹54,600 | 425 ₹55,250 | 410 ₹53,300 | 435 ₹56,550 | 425 ₹55,250 | 420 ₹54,600 | 419 ₹54,470 | 412 ₹53,560 | 415 ₹53,950 |
| 6.02 | Coolant for DG set.
Make: - TVS, Castrol, Bharat Petroleum, HP | 100 | Litre | 325 ₹32,500 | 330 ₹33,000 | 320 ₹32,000 | 340 ₹34,000 | 322 ₹32,200 | 325 ₹32,500 | 325 ₹32,500 | 315 ₹31,500 | 310 ₹31,000 |
| 6.03 | Distilled water for battery set. | 80 | Litre | 30 ₹2,400 | 30 ₹2,400 | 27 ₹2,160 | 32 ₹2,560 | 30 ₹2,400 | 30 ₹2,400 | 32 ₹2,560 | 21 ₹1,680 | 21 ₹1,680 |
| 6.04 | Oil Filter for 7.5 KVA to 50 KVA DG set.
(Make: - Kirloskar and Ruston) | 1 | Each | 1,400 ₹1,400 | 1,380 ₹1,380 | 1,250 ₹1,250 | 1,415 ₹1,415 | 1,340 ₹1,340 | 1,355 ₹1,355 | 1,354 ₹1,354 | 1,450 ₹1,450 | 1,450 ₹1,450 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
20 Sept 2025, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist-Darjeeling, WB-734009
REPAIR AND MAINTENANCE OF DG SETS CABLES SWITCHGEARS AND ALLIED WORKS OF U AREA UNDER GE SUKNA
2025_MES_728553_1
GE Sukna/8880
Open Tender
Civil Works
270 days
Sukna
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Sukna
₹96,000
12 Jan 2026
30 Aug 2025
22 Sept 2025
31 Aug 2025
20 Sept 2025
13 Sept 2025
31 Aug 2025 - 20 Sept 2025
Amount
Carrying out “A” Check maintenance of serviceable DG Sets as per manufacturer’s instruction and as given below for 7.5 KVA to 82.5 KVA, all available DG Set in Power House and Pump House at U area in Sukna Mil Stn complete all as specified and as directed. NOTES:- i) "A" check maintenance shall include:- a) Checking of oil level b) Checking cleaniness of DG set and cleaning the same c) Checkng battery voltage d) Checking any leakage e) Checking all filter condition f) Checking coolant level g) Checking 'V' belt condition ii) DG set of any capacity as and when required to be maintained.
Carrying out “B” Check maintenance of serviceable DG Sets as per manufacturer’s instruction and as given below (after running of 250 to 300 Hours) for 7.5 KVA and 50 KVA DG Set complete all as specified and directed. NOTES:- i) "B" check maintenance shall include:- a) Changing of oil b) Changing oil filter, fuel filter, bypass filter & gasket c) Changing Air filter d) Removing water from water separator ii) Supply only spares, components, engine oil etc, for carrying out “B” check maintenance shall be measured and paid separately.
Carrying out “B” Check maintenance of serviceable DG Sets as per manufacturer’s instruction and as given below (after running of 250 to 300 Hours) for 50 KVA and 82.5 KVA DG Set complete all as specified and directed. NOTES:- i) "B" check maintenance shall include:- a) Changing of oil b) Changing oil filter, fuel filter, bypass filter & gasket c) Changing Air filter d) Removing water from water separator ii) Supply only spares, components, engine oil etc, for carrying out “B” check maintenance shall be measured and paid separately.
Carrying out “C” Check maintenance of serviceable DG Sets as per manufacturer’s instruction (after running of 800 to 1500 Hours) for 7.5 KVA to 50 KVA DG Set complete all as specified and as directed. NOTE:- i) "C" check maintenance shall include:- a) Changing of oil b) Changing oil filter, fuel filter, bypass filter & gasket c) Changing Air filter d) Removing water from water separator e) Cleaning of radiator with chemical incl supply of chemical f) Checking of all electrical terminals & thimbles g) Engine injector setting h) Changing gasket for piston head ii) Supply only spares, components, engine oil etc, for carrying out “C” check maintenance shall be measured and paid separately. iii) Make: Kirloskar Cummins
Carrying out “C” Check maintenance of serviceable DG Sets as per manufacturer’s instruction (after running of 800 to 1500 Hours) for 50 KVA to 82.5 KVA DG Set complete all as specified and as directed. NOTE:- i) "C" check maintenance shall include:- a) Changing of oil b) Changing oil filter, fuel filter, bypass filter & gasket c) Changing Air filter d) Removing water from water separator e) Cleaning of radiator with chemical incl supply of chemical f) Checking of all electrical terminals & thimbles g) Engine injector setting h) Changing gasket for piston head ii) Supply only spares, components, engine oil etc, for carrying out “C” check maintenance shall be measured and paid separately. iii) Make: Kirloskar Cummins
Supply only the following spares as per existing make all as directed :-
Engine oil 20 W 40 / 10 W 40 Grade. Make:- Servo, Castrol, HP, Indian Oil Ltd., Bharat Petroleum
Coolant for DG set. Make: - TVS, Castrol, Bharat Petroleum, HP
Distilled water for battery set.
Oil Filter for 7.5 KVA to 50 KVA DG set. (Make: - Kirloskar and Ruston)
Oil Filter for 62.5 KVA DG set. (Make: - Greaves Cotton)
Oil Filter for 82.5 KVA DG set. (Make: - Greaves Cotton)
Fuel Filter for 7.5 KVA to 50 KVA DG set. (Make: - Kirloskar / Ruston)
Fuel Filter for 62.5 KVA DG set. (Make: - Greaves Cotton)
Fuel Filter for 82.5 KVA DG set. (Make: - Greaves Cotton)
By Pass Filter for 62.5 KVA DG Set. (Make :- Greaves Cotton)
By Pass Filter for 82.5 KVA DG Set. (Make :- Greaves Cotton)
Air Filter for 7.5 KVA to 50 KVA DG set. (Make: - Kirloskar / Ruston)
Air Filter for 62.5 KVA DG set. (Make: - Cotton Greaves)
Air Filter for 82.5 KVA DG set. (Make: - Cotton Greaves)
Piston Ring for 7.5 KVA to 82.5 KVA DG Set.
Gasket Set with Head Gasket for 7.5 KVA to 82.5 KVA DG Set.
Exhaust Valve for 7.5 KVA to 82.5 KVA DG Set.
Inlet Valve for 62.5 KVA to 82.5 KVA DG Set.
Inlet and Exhaust Valve guide for 62.5 KVA to 82.5 KVA DG Set.
Exhaust Insert Valve seat for 62.5 KVA to 82.5 KVA DG Set.
Inlet Insert Valve seat for 62.5 KVA to 82.5 KVA DG Set.
Rocker Bush for 62.5 KVA to 82.5 KVA DG Set.
Rocker shaft for 62.5 KVA to 82.5 KVA DG Set.
Rocker arm for 62.5 KVA to 82.5 KVA DG Set.
Push rod Intake for 62.5 KVA to 82.5 KVA DG Set.
Push rod Exhaust for 62.5 KVA to 82.5 KVA DG Set.
Push rod Injector for 62.5 KVA to 82.5 KVA DG Set.
Housing Cam Follower for 62.5 KVA to 82.5 KVA DG Set.
Cylinder Head Cap Screw for 62.5 KVA to 82.5 KVA DG Set.
Valve Spring for 62.5 KVA to 82.5 KVA DG Set.
Injector Sleeve for 62.5 KVA to 82.5 KVA DG Set.
Rocker Housing Cap Screw for 62.5 KVA to 82.5 KVA DG Set.
Water Pump Repair Kit for 62.5 KVA to 82.5 KVA DG Set.
Water Pump Assembly for 7.5 KVA to 50 KVA DG Set.
Water Pump Assembly for 62.5 KVA to 82.5 KVA DG Set.
Injector Barrel and Plunger for 62.5 KVA to 82.5 KVA DG Set.
Injector Cup for 62.5 KVA to 82.5 KVA DG Set.
Manifold Fuel Drain for 62.5 KVA to 82.5 KVA DG Set.
Manifold Fuel Suppy for 62.5 KVA to 82.5 KVA DG Set.
Tube Fuel Suppy for 62.5 KVA to 82.5 KVA DG Set.
Fuel Connection for 62.5 KVA to 82.5 KVA DG Set.
Shut down Valve for 62.5 KVA to 82.5 KVA DG Set.
Manifold Fuel Drain for 62.5 KVA to 82.5 KVA DG Set.
Manifold Fuel Suppy for 62.5 KVA to 82.5 KVA DG Set.
Piston Ring for 62.5 KVA to 82.5 KVA DG set.
Inlet Valve for 62.5 KVA to 82.5 KVA DG set.
Exhaust Valve for 62.5 KVA to 82.5 KVA DG set.
Connecting Rod Bolt for 62.5 KVA to 82.5 KVA DG set.
Set of Joint for 62.5 KVA to 82.5 KVA DG set.
Valve Seat Inlet for 62.5 KVA to 82.5 KVA DG set.
Valve Seat Exhaust for 62.5 KVA to 82.5 KVA DG set.
Air Release Valve for 62.5 KVA to 82.5 KVA DG set.
Vavle Push Rod for 62.5 KVA to 82.5 KVA DG set.
Vavle Spring (Inner) for 62.5 KVA to 82.5 KVA DG set.
Cylinder Head gasket (1mm) for 62.5 KVA to 82.5 KVA DG set.
Vavle Spring (Outer) for 62.5 KVA to 82.5 KVA DG set.
Banjo Bolt for 62.5 KVA to 82.5 KVA DG set.
Banjo Bolt Washer for 62.5 KVA to 82.5 KVA DG set.
Feed Pump Tappet for 62.5 KVA to 82.5 KVA DG set.
Fuel Pump Element for 62.5 KVA to 82.5 KVA DG set.
Fuel Pump Delivery Valve for 62.5 KVA to 82.5 KVA DG set.
Injector Nozzle for 62.5 KVA to 82.5 KVA DG set.
Connecting Rod Bearing for 62.5 KVA to 82.5 KVA DG set.
Main Bearing Set for 62.5 KVA to 82.5 KVA DG set.
V Belt for 25 KVA DG set. (Make: - RUSTON)
V Belt for 62.5 KVA DG set. (Make: - Graves Cotton)
V Belt for 82.5 KVA DG set. (Make: - Cotton Graves)
Maintainence Free 12V 180AH Battery (Make: - Exide/ Amron/ SF)
M&L taking out self starter for carrying out repair / overhauling of self starter assembly for 25 KVA DG Set and including replacement of following spare parts and refixing and testing complete all as specified and directed:- i) Armature- 01 No ii) Clutch Plate- 01 Set iii) Solenoid Switch- 01 No iv) Carbon Brush- 01 Set v) Field Coil- 01 No vi) Carbon Rocker- 01 No
M&L taking out self starter for carrying out repair / overhauling of self starter assembly for 62.5 KVA DG Set and including replacement of following spare parts and refixing and testing complete all as specified and directed:- i) Armature- 01 No ii) Clutch Plate- 01 Set iii) Solenoid Switch- 01 No iv) Carbon Brush- 01 Set v) Field Coil- 01 No vi) Carbon Rocker- 01 No
M&L taking out self starter for carrying out repair / overhauling of self starter assembly for 82.5 KVA DG Set and including replacement of following spare parts and refixing and testing complete all as specified and directed:- i) Armature- 01 No ii) Clutch Plate- 01 Set iii) Solenoid Switch- 01 No iv) Carbon Brush- 01 Set v) Field Coil- 01 No vi) Carbon Rocker- 01 No
Dismantling of alternator assembly of 7.5/25 KVA DG set and including carrying out heating and varnishing of field / stator coil and rotor / armature assembly using class "E/H" (as applicable) insulating varnish (Dr Beck) overhauling, replacement of unserviceable parts, transportation to workshop complete all as specified and directed. Note: Supply only spares shall be measured and paid seperately.
All as per Sl. item No. 10 above but 62.5/82.5 KVA DG set
Taking out alternator assembly from the base of DG Set incl disconnection of cable for carrying out routine maint /major repair at out side workshop in the following phase of work for 62.5/82.5 KVA DG Set installed at Power House / Pump House of U Area i) Transportation of alternator from Power House / Pump House to outside Workshop. ii) Dismantling of alternator assembly, removing of all dust, carbon particle etc from from housing , removing burnt /damaged winding of field coil/stator assembly, rotor/armature assembly,cleaning of Exitor unit using carbon Tetra Chloride & blowing of forced air. iii) Carrying out rewinding by super enamelled copper wire and varnishing and heating of field/stator coil and Rotor/armature assembly using class "E/H (as applicable) insulating varnish ( Dr BECK ) incl necessary partial replacement of insulating materials viz, insulated cotton tape, fiber glass tape, Empire tubes of different size insulating board/ packing/ separator materials all as required and as directed by Engineer- in Charge as per existing arrangement. iv) Carrying out testing of alternator after assembling with Engine all as directed and to the entire satisfaction of Eng-in- Charge.
M&L taking out unserviceable battery charging alternator and carrying out repair / overhauling of alternator for 7.5/25 KVA DG Set including replacement of following spare parts and refixing, testing complete:- i) Armature- 01 No ii) Carbon Brush- 01 Set iii) Carbon Rocker- 01 No. iv) Field Coil- 01 No
All as per Sl. item No. 13 above but 62.5/82.5 KVA DG set
All as per Sl. item No. 13 above but 25 KVA DG set
All as per Sl. item No. 13 above but 62.5/82.5 KVA DG set
M&L taking out 7.5/25 KVA Water pump assy for carrying out repairs and including replacement of water pump kit & L Hose (01 Set) & re-fitting complete all as specified and directed.
All as per Sl. item No. 17 above but 62.5/82.5 KVA DG set
S&F Fuel Inlet Hose pipe (diesel tank to PT pump) for 7.5/25/62.5/82.5 KVA
S&F Fuel Overflow hose pipe (nozzle to diesel tank) for 7.5/25/62.5/82.5 KVA
S&F Slip Ring 7.5/25 KVA DG Set (Make: - Kirloskar/RUSTON)
S&F Slip Ring 62.5/82.5 KVA DG Set (Make: - Greaves Cotton)
S&F Automoatic Voltage Regulator 7.5/25 KVA (Make: - IRI/ Kirloskar)
S&F Automoatic Voltage Regulator 62.5/82.5 KVA (Make: - IRI/ Kirloskar)
S&F Carbon Brush 7.5/25/62.5/82.5 KVA DG Set (Make: - Kirloskar/Ruston/Cotton Graves)
S&F Carbon Brush Holder 7.5/25/62.5/82.5 KVA DG Set (Make: - Kirloskar/Ruston/Cotton Graves)
S&F Silicon Diode Negative 7.5/25/62.5/82.5 KVA DG Set (Make: - Kirloskar/Ruston/Cotton Graves)
S&F Silicon Diode Positive 7.5/25/62.5/82.5 KVA DG Set (Make: - Kirloskar/Ruston/Cotton Graves)
S&F Alternator Bearing DE/NDE 7.5/25 KVA
All as per Sl. item No. 29 above but 62.5/82.5 KVA DG set.
S&F Battery Terminal Negative (Length: - 1 to 1.5 meter)
S&F Battery Terminal Positive (Length: - 1 to 1.5 meter)
S&F Battery Terminal End Negative & Positive
S&F Battery Terminal Socket
S&F Radiator Hose Clamp any size
All as per Sl. item No. 35 above but 25 KVA DG set.
All as per Sl. item No. 35 above but 62.5/82.5 KVA DG set.
Taking out radiator assembly from the DG Set incl disconnection of hose for carrying out routine maint /major repair at out side workshop in the following phase of work for 7.5/25 KVA DG Set installed at Power House/Pump House i) Transportation of radiator from Power House/ Pump House to outside Workshop. ii) Dismantling of radiator assembly, removing of all dust, carbon particle etc iii) Carrying out repair, cleaning, making leak proof of radiator assembly incl filling of coolant replacement of gaskets, bolts nuts etc for 7.5 KVA DG Set. (spare parts to be incorporated shall be measured and paid separately under respective items)
All as per Sl. item No. 38 above but 62.5/82.5 KVA DG set.
S&F RPM Meter for any DG Set
S&F RPM Meter cable for any DG Set
S&F Water Safety Control for any DG Set
S&F Oil Safety Control for any DG Set
Supply,laying testing and commissoning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 10 sqmm 4 core, complete all as specified and directed.
Supply,laying testing and commissoning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 25 sqmm 4 core, complete all as specified and directed.
Supply,laying testing and commissoning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core, complete all as specified and directed.
Supply,laying testing and commissoning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) LT Cable with stranded aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core, complete all as specified and directed.
Excavation in trenches in any type of soil (soft/loose soil) not exceeding 1.5 metre wide and not exceeding 1.5m in depth LT under ground cables/GI pipes for trenches, complete all as specified and directed.
Returning, filling in, including spreading watering and well ramming in layers not exc 25cm in layers, complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M&L for sand cushioning to under ground cable using locally available fine clean dry river sand over, under ground UG cable laid in trenches and gently punning to cushioning to cable complete all as directed by Engineer-in-charge. Note :- For the purpose of payment only punned thickness will be measured.
M&L for brick protection cover of size 230x115x75 mm to LT underground cables with sub class 'B' over burnt brick, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10 mm complete all as specified and directed.
Supply and fixing GI tubing light grade 80 mm dia for protection pipe along with nuts bolt washers or laid in trenches under roads complete incliding taking out if required all as specified and directed.
Boring/Drilling (horizontally) manually under min 0.5 to 2 m deep in soil below existing road suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
S&F MCCB 4 Pole, 415 V, adjustable type, 100 Amps with breaking capacity 16 KA including taking down of old unsv one complete all as specified and as directed.
S & F MCCB in repair 4 Pole 400 Amps, 36 KA , Ics = 100% Icu, adjustable short circuit and overload protection, spreader link including taking down old one complete all as specified and as directed.
S & F MCCB in repair 4 Pole 250 Amps, 25 KA Ics = 100% Icu, adjustable short circuit and overload protection, spreader link including taking down old one complete all as specified and as directed.
Supply and fixing in repair of MCB TPN DB 4 way double door, IP-43 protection, isolated neutral bar, insulated busbar assembly, mechnical impact strength of IK08 complete including taking down of old unsv one complete all as specified and as directed.
Supply and fixing in repair of MCB TPN 63 Amps 'C' series 10 KA 415 volts complete all as specified and directed.
S&F MCB, SPN DB, 8 Way double door, metal door, IP-43 IK-09 in 200A rated bus bars, earth bar, neutral links complete incl blanking plates as required & fixed to wall and making good the disturbed surfaces complete all as specified and directed
Supply and fixing in repair of MCB SPN 40 Amps 'C' series 10 KA 240 volts including takign down of old unsv one complete all as specified and directed.
Supply and fixing in repair of MCB SP 6-32 Amps 'C' series 10 KA 240 volts including takign down of old unsv one complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M & L in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall complete all as specified and directed.
M&L Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismentaling old unsv ones complete all as specified and as directed by the Engineer-in-Charge.
S&F 4 mm dia wire for earth continuity conductor for making connection from earth test point to main DB including taking down of old unsv one complete all as specified and directed.
M&L for chemical earthing complete with galvanised steel earth plate electrode of size 900 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of copper earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M & L in repair for Earth continuity conductor or main earthing lead of copper strip of 32 x 6 mm, buried in ground or fixed to wall in repair complete all as specified and directed.
Supply, installation, testing and commissioning of Panel board not less than 1.0m x 0.75m x 1.80m, outdoor cubical type factory made (CPRI approved), double door, front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches, fabricated of CRCA sheet, inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick, rubberised gasket, supported on 50x50x6 mm angle iron and Tee section frame dust and proof complete with aluminium bus bar 4 Nos 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity bus bar/ PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & washers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complate, connecting existing cables with suitable size glands and lugs to accommodate and including the following:-
Supply, installation, testing and commissioning of Panel board not less than 1.50m x 1.20m x 0.50m, outdoor cubical type factory made (CPRI approved), double door, front and back both side openable type fixed with (CPRI) approved, double door, front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches, fabricated of CRCA sheet, inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick, rubberised gasket, supported on 50x50x6 mm angle iron and Tee section frame dust and proof complete with aluminium bus bar 4 Nos 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity bus bar/ PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & washers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complate, connecting existing cables with suitable size glands and lugs to accommodate and including the following:-
Supply, installation, testing and commissioning of Panel board not less than 0.800m x 0.600m x 0.50m, outdoor cubical type factory made (CPRI approved), double door, front and back both side openable type fixed with (CPRI) approved, double door, front & back both side openable type fixed with Butt Hinges and locking arrangement with Aldrop latches, fabricated of CRCA sheet, inner sheet 2.0 mm thick hinged type door for individual MCCBs and outer door 3.15 mm thick, rubberised gasket, supported on 50x50x6 mm angle iron and Tee section frame dust and proof complete with aluminium bus bar 4 Nos 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity bus bar/ PVC insulated copper cable control wiring duly mounted on PCC foundation with suitable size of bolts, nuts & washers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complate, connecting existing cables with suitable size glands and lugs to accommodate and including the following:-
Supply of LT bus bar panel board "out-door Supply, install, testing & commissioning of LT panel board "out-door type" of size 900 mm (height) x 750 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable & 4 side slanting canopy on roof top. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned double Al bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating.
The panel board shall be fabricated out of 3.15 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50X50X5 mm angle iron & MC 100 channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation necessary earthwork and including the following accessories. BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos aluminiume conductor size 25X6, 350 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY :- The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING :- MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 25 KA of rating 250 A - 01 Nos. (a) Spreader Link - 01 Set (b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos.
S&F cubical type manual changeover switch I-O-II type operation 250 Amp rating 415 volt, with extended shaft and handle suitable for fixing over wall/ outside of Panel body complete.
R N SAH N CO (BID ID -3430388)
Janata Enterprises (BID ID -3430861)
PS ENTERPRISE (BID ID -3430379)
SHRI N.DAS (BID ID -3430445)
M/s TRIMURTI ASSOCIATE (BID ID -3430438)
MS ESSCON (BID ID -3429772)
MS ORIENT ENGINEERING WORKS (BID ID -3430341)
ELECTRO WIR WAY (BID ID -3428845)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid