Tender Value
₹14.9 L
EMD Value
₹29,720
Closing Date
21 May 2025, 6:00 pmClosed
CWE
HQ CWE (AF) CHAKERI KANPUR208008
REPAIR MAINT OF 33KV HT UG CABLE ISOLATOR RELAY PANEL AND MAINT OF 33 KV YARD AT AFS MANAURI UNDER AGE(I) (AF) MANAURI
2025_MES_705366_1
CA NO. CWE(AF)/CHK/MNR/T-09 OF 2025-26 82430/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) Manauri
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE(I) MANAURI
₹29,720
Yes
2 Jul 2025
24 Apr 2025
23 May 2025
24 Apr 2025
21 May 2025
9 May 2025
Amount
M&L Servicing, Testing of Transformer 1500 KVA 33/11 KV Outdoor, Disconnecting all Internal Connections of HT Side for Periodical Maintenance such as Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, etc. after Assembling, complete all as specified and as directed. NOTE :- (a) Cost of Transformer Oil for Cleaning by Hosing down shall deem to be included in the Quoted Unit Rate. (b) Replacement of Spares Parts will be Measured and Paid separately under appropriate Items.
Supply only Breather Assembly filled with Silica Gel for Transformer 1000 KVA to 2000 KVA, 33/11 KV Outdoor as approved, complete all as specified and as directed.
Supply and fixing porcelain transfomer Bushing of capacity 36KV/1000 Amp Transformer rating capacity, visible voltage 27 V, Power frequncy one minute withstand voltage 75 in Dry/Wet, Impulse withstand voltage 170 V, as per IS 3347 Part III & IS 2009 complete with all fixing accessories all as directed by Engr-in-Charge.
Supply only Brass Spindle for Terminal on LT Side Threaded complete with Nut, Washers, etc. of dia as ordered/ as approved and suitable for Transformer 1500 KVA, 33/11 KV, complete all as specified and as directed.
Supply only Ceramic Bushing and Gasket on LT Side of Transformer 1500 KVA, 33/11 KV, complete all as specified and as directed.
Supply only Ceramic Bushing and Gasket on HT Side of Transformer 1500 KVA, 33/11 KV, complete all as specified and as directed.
Supply only Gasket (Cock Sheet) 6.0mm thick with Conical Rubber Bush Complete as approved and suitable for Transformer 1500 KVA, 33/11 KV including Taking down/ out Old Unserviceable Gasket, complete all as specified and as directed.
Disconnecting and Taking out existing 11 KV HT VCBs of any Make from Housing, Cleaning, Rubbing and Overhauling the Mechanical Parts, Servicing of 11 KV Indoor VCB, Checking of quality of Vacuum Interrupter, Insulation Resistances, Static Contact Resistance, Testing (IR Value, Ratio Test, Polarity Test) and Connection and Verification of 6.6 KV Current Transformer (Set of Three) by Primary Injection Kit and Testing and Calibration of Relay (Set of Two Over Current and One Earth Fault) by Secondary Injection Kit including all other Functional Tests of the VCB, C&R Panel and CTs, PTs Setting Right the Mechanism and Re-assembling, Testing and Commissioning, etc. as required, complete all as specified and as directed. (a) Taking out Trolley Unit from Metal Clad Housing and Dismantling complete, Carrying out Inspection Cleaning, Mechanical Spring, complete all as specified and directed. (b) Opening of Bus-bar Chambers, Carrying out Inspection, Cleaning of Complete Unit and Re-fixing of the Bus-bar, complete all as specified and directed. (c) Carrying out Testing of all Metering Instruments, Replacement of Worn out Spares, Meter, Wiring Cable, etc. and Testing, complete all as specified and directed. (d) Inspection and Checking of all Protection Devices, Relays, complete all as specified and directed. (e) Carrying out Inspection and Testing of Auxiliary Power System, complete all as specified and directed. (f) Assembling of Complete HT Switch Gear Unit, proper Greasing, Oiling for Easy Operation and Connection of Incoming and Outgoing Cable and making all necessary Adjustment and Testing, complete all as specified and directed. NOTE : Replacement of Spares such as Gasket Set, HT Trolley Bushes, Plug Insulators, Bus-bar Insulator for HT VCB, PT Bush for HT VCB, PT Housing Bush for HT VCB, Interrupter of HT VCB HT HBC Fuse Link, IDMTL Relay, Power Pack 230 V/110 V DC 20A and CT Ratio 100-50/5A, etc. shall be Measured and Paid separately under relevant Items.
Supply and fixing 11 KV Vacuum Interrupter with TC suitable for 11 KV VCB Panel, complete all as specified and as directed. MAKE : CG/ABB as approved by GE.
Supply and fixing CA3KN22FD, 2NO+2NC, 3P, 110 Volt DC Control Relay suitable for HT VCB Panel, complete all as specified and as directed. MAKE : ABB / SCHNEIDER / SIEMENS
Supply and Fixing MK II A, 80W, 230V, Panel Space Heater suitable for HT VCB Panel, complete all as specified and as directed. MAKE : ABB/ BE/ GE/ SCHNEIDER/ SIEMENS
S&F LED Indicator with Wiring suitable for existing HT VCB Panel as per existing Make after Taking down carefully Old Unserviceable Indicator with Wiring, complete all as specified and as directed.
S&F HT 11 KV VCB Panel Spout Insulator, round shape, rust proof, red colour after taking down carefully Old unserviceable VCB Panel Spout Insulator, complete all as specified and as directed. MAKE : ECS/GEMINI/JSL/L&T/PRAGATI/SCHNEIDER or as per existing in VCB's.
S&F HT 11 KV VCB Panel TNC Switch BCA02 as per existing in VCB's after Taking down carefully Old Unserviceable VCB Panel TNC Switch, complete all as specified and as directed.
S&F HT 11 KV Bus-bar Insulator with Bolts, Nut, Washers, etc. after Taking down carefully Old Unserviceable Bus-bar Insulator with Bolts, Nut, Washers, etc., complete all as specified and as directed.
Supply and fixing Siemen Shower brass type or copper, epoxy compound powder coated for 11 KV VCB complete with taking down old unsv all as directed by Engr-in-Charge.
M&L for lightening arrestor non linear resistor type confirming to Fe 410 W (gde -E-250) quality "A" complete line discharge class 3 nominal discharge current 10 KA station class & high discharge with stand 100 KA assembly suitable for 33 KV working pressure and mounted on hot dip galvanised steel structure including all clamp nuts bolt and washers etc connecting to earth 32 x 6 MM GI strip including taking out the same complete all as specified and directed. Note ;- MS channel and angle shall be measured and paid seperately.
Supply, installation & testing Pin insulator porcelain, vitreous, white, brown or green 145 MM height 255 MM dia including one galvanized mild steel spindle, two galvanised washers and one galvanised iron nuts for conductor working pressure 33 KV (33000 Volts) grade including taking down old unsv pin insulator complete all as specified and directed by Engr-in-Charge.
Supply and fix for three- in- series assembly (Disc type insulator) each having working pressure of suitable for working presure 33 KV (33000 volt ) three -in- series assembly for tension with tension clamp insulator porcelain brown vitreous insulator with spindle nut of size 145 MM height 255 MM dia including galvanised mild steel spindle two Nos socket type GI washer,bolt & nut complete all as specified and directed.
Supply, installation & testing Post insulator suitable for rated nominal/maximum rated voltage 33/36 KV, rated current 1250 Amp including taking down old unsv post insulator complete all as directed by Engr-in-Charge.
Supply and fixing cross arms / angle frame / MS sheet to made out bracings supports / clamp , back plates fabricated from strucural steel sections including nut bolt washers etc with bending cutting welding to hot /cold drilling holes for bolts in any shape or size as indicated inclusive of applying one priming coat and two coats using synthetic enamelled paint conforming to Fe 410 W (Gde- E- 250) quality "A" complete all as specified and directed.
Supply, straining and stringing of alumunium conductor steel reinforced (ACSR) in given specification/ make /model/ type etc for making interconnection of net work fixing on existed structure/pole etc for making inter connection in yard including thembles / cramping bolt with nut washer / PG clamp etc as per site requirement complete all as specified and as directed. Note :- (i) Sagging length of ACSR conductor (in given size / make / model) shall be deemed included in the quoted unit rates no separate measurement shall be paid to contractor. (ii) Quoted rates shall be inclusive of the cost of all required accessories i.e.thembles / cramping bolt / PG clamp with nut bolt and washer etc to all required for making inter connection between protection devices in bay of yard. (iii) All run of ACSR shall be continuosly painted by luminious colour paint in colour coding OR covered by luminious colour strip.
Supply, install, testing and commissioning of gang operated air break isolator switch out door type triple pole revolving type and double break suitable for horizontal mounting consisting of hot dip galvanized channel iron base having 2 Nos 33 KV working pressure post type insulator in stack and 3 such stacks per pole ,copper or copper alloy high pressure heavily tinned and double contacts plated MS arcing horns capable of breaking mgnetising current complete with phase coupling bar 25 MM dia GI pipe as down rod , lever coupling and operating handle with locking arrangement as for both ON and "OFF" positions coupling connections etc suitable fo 33 KV 3 phase 50 Hzs Ac supply system having 400 Amps capacity all as speicifed in IS - 1818 of Oct 1972 including interlocking with 33 KV VCB (out door type) complete all as directed.
Supply, installation, testing 33 KV current transformer oil cooled, outdoor type, single phase, oil immersed and self cooled type of ration 50/ 25/ 5+5+1 suitable for metering and protection equipment installed on control panels terminal block as specified below :- (a) Normal system voltage - 33 KV (b) Highest system Voltage 36 KV (c) Rated primary current - 50-25 Amp (d) Rated secondary current - 5 Amp/1 Amp (e) Nos of core - 04 (f) Continuous thermal current rating 120% of rated primary current. (g) Temp rise at rated continuos thermal current over ambient at site less than or equal to 45 degree C (h) Insulation level 36/70 KV, 170KVP (j) 1.2/50 Micro second impulse withstand test voltage - 170 KV (peak) (k) Short time thermal current rating for one second - 25 KA/1 second (m) Dynamic Current rating 62.5 KA (peak) (n) Porcelain bushing type - Hollow Cylinder (p) Creepage distance of HV bushing - 900 mm (min) (q) Primary and Secondary winding material - Copper Note : Old unsv 33 KV current transforemer deposit to MES Store yard.
Supply, installation, testing of 33 KV Potential Transformer (PT) oil cooled outdoor type, single phase (Earthed type) of voltage ration 33KV/root 3 (1.732)/110V/root 3(1.732) rated burden 100 VA with 0.5 accuracy (33KV/root3(1.732)/110/root 3 (1.732) as per following specification : - (a) Normal system Voltage - 33 KV (b) Highest system Voltage - 36 KV (c) Rated primary volatge - 33 KV/root 3 (1.732) (d) Rated secondary voltage - 110V/root 3 (1.732) (d) Nos of LT winding - 02 (e) Metering core accuracy class - 0.5 (f) Metering core rated Burden - 100 VA (h) Numbers of phase - Single (Earthed type) (j) Protection core accuracy - 3 P (k) Protection core reated Burden - 100 VA (l) Rated voltage factor - 1.2 contineous thermal current over ambient at site 45 C (m) Porcelain Bushing type - Hollow Cylinder (n) 1.2/50 mcro second impulse withstand test vol - 170 KV (peak) (p) Creepage distance of HV bushing - 900 mm (q) Primary and Secondary winding material - Copper Note : Old unsv 33 KV Potential transforemer deposit to MES Store yard.
Material and labour for perodical servicing ,repairing & testing of 33 KV outdoor SF6 circuit breaker including relay and control panel of capacity 1600 Amps and rating 36 KV complete as details mentioned as under:- (a) Details of periodical servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iv) Checking the contact for wear. Replace if the contact piece has worn out. (v) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (vi) Check for rust and wear. (vii) Checking of spring charge mechanism (viii) Visual check for rust and deformation. (ix) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (x) Check for loosened connections, rust, damaged lead wires. (xi) Checking of control circuit & tighten the connections if any. (xii) Check close & trip coil. (xiii) Replacement of Dashpot/shock absorbers . (xiv) Replacement of carbon brush of spring charging motor (xv)Cleaning of porcelain bushing (xvi)Checking of limit switch
(b) The following test shall be carried out:- (i) Primary Injection Test of outdoor CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Testing VCB bottle (vi) Closing coil resistance (vii) Tripping coil resistance. (viii) High voltage test. (ix)Testing of Over current and earth fault numeriacal relay of control panel with Secondary Injection Kit ,checking, programming & coordination of relay as directed by Engr-in-Charge. (x) Testing of auxilary relays such as DC Supply supervision relay, Master trip relay ,Buchholz relay , WTI relay,OTI relay & etc. Note- . The rates for Nuts, bolts, washers, lugs, thimble, wires and minor items required for efficient and smooth functioning of the equipment shall deemed to be included in in the quoted item. Rates for testing equipments and accessories required at site for condcuting above tests shall deemed to be included in quoted rates by contractor.
Supply and fixing SF6 circuit breaker motor 200 watt, 220-250 V, AC-DC, 50 Hz as per existing make and model complete all as specified and directed by Engr-in-Charge.
M&L XLPE insulated, Heavy duty, Galvanised steel strip or wire Armoured, stranded copper conductor Electric LT cable, 1100 Volts grade, cross sectional area 1.5 Sqmm 8 core complete with all connection and taking out old unsv cable complete all as specified and directed by Engr-in-charge.
Supply, laid in trench/ fixed with surface of wall / roof etc, jointing, thembling and glanding in suitable size , testing in replacement to HT XLPE cable insulated, screened, PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) with alumunium conductor 33 KV, grade cross section area 300 Sqmm of 3 core complete all as specified and directed. Note : Excavation earth work cable cover, sand cushioning etc shall be measured and paid separately under respective items)
Supply and laying reinforced precast concrete cable cover class HVP type 1 with peak size 300mm x 180mm x 40mm in trenches for protection to under ground cable complete all as specified and dirceted by Engr-in-Charge.
Supply, fixing, connecting, jointing, thembling to end of cable and commissioning and testing in replacement of heat shrinkable cable jointing kit suitable for 33 KV grade (earthed) cable for outdoor type end termination complete with jointing material and accessories suitable for 3 core XLPE insulated armored aluminium conductor cable of size 300 Sqmm 3 core including taking down existing complete all as specified and directed. (Note : Excavation & work shall be measured and paid against respective items) (Make : Denson or M- Seal or Raychem)
All as above item No-31 here-in-before but straight through heat shrink type joint suitable for, 33 KV graded 3 core x 300 Sqmm (earthed) XLPE armored cable complete.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out including trimming of sides complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note :- punned thickness shall be measured and paid only .
M&L for advance maintenance free chemical earthing with JMV CBE 403 enviornment friendly ring earthing system consisting each set of 03 (three) Nos of 10 (ten) feet length 40 mm dia earth eletrode made out by copper, maintenance free electrolytic grade copper earthing system of JMV make based on flat in pipe technology of 3 Mtrs length , 40 mm dia with crystalite conductive mixture COMPOUND filled withthe permanent sealings at the top & bottom with the lead terminal / strip in 25x4 mm size copper with 2 holes of 10 mm dia at the top , to be lowered in 150 mm dia bore including filling of back fill ecofriendly earth enhancing compound tested by ROHS comply to IEC 62651-7 which should have passed leaching ,corrosion, supphur & resistivity test as per IEC 62651-7 by NABL accredit LAB/JAM plus compound in 150 mm bore in immediate contract around the earth electrode and top of the bore shall be finished with 40 mm thick PCC in 1:2:4 type B 1 over 75 mm thick PCC in 1:4:8 type D-2 and backfilly/ JAM compound shall be covererd with FRP pit cover of suitable size for each earth electrode , joint to be made by JAM weld exothermically welded technology including copper strip size 32 x 6 mm for earthing ring system and copper strip 32x6 mm size for earthing electrode to test point with saddles & porcelain insulators suitable size on wall ,earth strip protected by light grade GI pipe 40 mm dia in case of plinth protection / floor/ hard standing crossing complete all as specified and directed. Make - JMV LPS Limited / JEF/ ALCOICE / Conducrete Note :- Earth work , PCC work, PCC cutting work by cutter, earth chamber in suitable size with testing on suitable value etc rate shall deemed to be included in quoted rate
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead using GI earth strip in size 32 x6 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Dismantling of ACSR conductor from poles of any size & capacity and removing unserviceable materials from site(s) complete all as specified and as directed.Note : (a) Contractor shall deposit the ACSR conductor to MES Store yard.(b) Contractor shall be quote the rate including transportation charges.
Dismantling cross-arms of M.S. channel or angle sections flat, nuts, bolts, washers etc. and removing unserviceable materials from site(s) complete all as specified and directed.Note : Contractor shall be deposit the cross arms to MES Store yard.
Dismantling insulators any type, any size complete all as directed by Engr-in-Charge.Note : Contractor shall be deposit the cross arms to MES Store yard.
Dismantling steel tubular pole 11 mtr long poles/struts in various location and deposited to MES store yard as per direction of Engr in charge. Note : (a) contractor shall be quote the rate including excavation, returning, filling and transportation charges of steel tubular pole from various location to MES Store yard.
Supply, Installation, Testing and commissioning of Transformer monitoring system (TMS) software with Data lodging (for main transformer), Instruments/sense Hardware, data collection and lodger, etc complete with all necessary item for 33/11 KV transformer capacity 1.50 MVA at main receiving station Manauri. The system monitoring of following parameters. (a) Analyze load factor (b) Load forecasting (c) Load scheduling (d) Incoming load (e) Outgoing load and related parameters (f) Map the energy consumption according to major loads, make pie chart of energy usages. (g) Establishing the baseline and SEC per unit of outcome of the facility (KWH/MLD)
The “ Transformer Monitoring System” will define to meet the following objectives. (a) Conduct a monitoring/observation of the energy consumption of the (details in particulars) transformer of the station. (b) Review and analysis energy usage history to create a baseline for which saving can be measure in the audit area. (c) Determine what can be done to reduce energy consumption throughout the present installations/setup and what are options are available for system improvements if finding will available. (d) Identify and evaluate measures that could improve the environment performance of the present installations and provide recommandations.
M&L for Transformer oil testing as per IS code IS 1866-2017 through authorised test lab as ISO/IEC 17025:2017 cerified testing laboratory. Transformer oil test should be carried out as per following :
(a) Dissolve Gas Analysis as per IS-10593 (b) Moisture or water Content as per IS 13567 (c) Breakdown voltage (BDV) as per IS 6792 (d) Appearance and colour as per IS 1448 Part 12 (e) Density as per IS 1448 Part 16 (f) Acidity as per IS 1448 part 21 (g) Flash Point as per IS 1448 Part 21 (h) Resistivity as per IS 16840 (j) Tan Delta as per IS 16840 (k) Sediment and sludge as per IS 1866 (m) Inter Facial Tension (IFT) as per IS 6104 Note:-Contractor should be submit the transformer wise report to Engr-in-Charge.
Note : Collection of transformer oil should be carried out in presence of JE E/M (b) Transformer oil should be collect in suitable size and clean botle as per lab direction (c) Contractor shall be quote the rate including transportation and required material for oil testing.
M&L checking (all connection and mechanism) cleaning overhauling servicing of 3 phase 11 KV ring main unit (RMU) extensive type 630 Amps rating with servicing of cable test compartment, Gas Tank, Interlocking latch for cable test compartment, padlocking system for load break switch, ring switch cable compartment, including replacement to minor spare such as spring copper finger/contact set male and female locking arrangement , relay time re-setting, right mechanism to all for making serviceable by OEM authorised work shop only and reassembling testing and commissioning complete at site all as specified and directed. (Note:- Quoted rate shall be included cost of required other spares & serviceable of RMU).
Supply and fixing termination boots suitable size for 11 KV RMU unit capacity 630 Amp including taking down old unsv termination boots all as directed by Engr-in-charge.
Supply & fixing in replacement of 12 Volt 150AH,short tubular inverter battery with rugged construction maintenance free battery mounted on steel rack complete ,testing and commissioning all as specified and as directed. Make- Exide/Amarraja/Amron
Supply & replace battery lead of 1 mtre length, PVC insulated multistranded copper conductor of size 25 sqmm including one side cable lugs and other side battery terminal. complete suitable to connect starter of any sizes of DG set.
Supply and fixing Inverter 12 volt 900 VA max load 756 watt, inverter type pure sine wave inverter with digital display, processor intelligent 32 bit DSP processor MCB for protection from input main complete with mounting stand suitable for inverter and Battery complete all as specified and directed by Engr-in-Charge.
Supply and filling new transformer oil having die electric strength not less than 45 KV in sealed container complete including centrifuging of oil (if required ) up to getting dielectric strength not less than 45 KV complete all as specified and directed. Note : Transformer oil will be supplied by the contractor in sealed container of approved make alongwith necessary manufacturer test cetificate and purchase vouchers Make: Power oil or Savita or equivalent make given in Appx 'B' duly approved by AGE (I).
Supply and fixing in replacement fire retardant/extinguishing electric insulated synthetic mat insulatica-2000 of size 1 Mtr x 2 Mtr x 5 mm thick +10% confirming to BIS : DOC No ET-02 (5440) dated 30 Apr 2004, meeting requirement of IS-3043, IS-5216 (Part I, II, III) IS-8437 and IEC 479 pub I, tested for breakdown strength, tensile/Elongation ageing properties, insulation resistance, effect of acid, alkaline, diesel and transformer opil leakage current test, fire test etc. including all allied materials such as PU-resing, chemical bound (Haedener) special PVC adhesive liquid primer etc of required quantity to complete the job as per site requirement
Adinath Technical Services (BID ID -3302161)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .