| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.5 LAdmitted-Finance N A | NA | NA | 121004 | -42.99% | ₹16.5 L | L1 | Admitted-Finance |
| 2 | L2₹18.1 L+₹1.6 L (9.68%)Admitted-Finance 44 DDA MARKET PUNJABI BASTI ARUNA NAGAR MAJNU KA TILLA DELHI 110054 | CENTRAL DELHI | DELHI | 110054 | -37.47% | ₹18.1 L+₹1.6 L (9.68%) | L2 | Admitted-Finance |
| 3 | L3₹21.2 L+₹4.6 L (28.1%)Admitted-Finance 17 JASDEEP OMPLEX 17 JASDEEP OMPLEX RK ROAD RK ROAD LUDHIANA PUNJAB 141003 | LUDHIANA | PUNJAB | 141003 | -26.99% | ₹21.2 L+₹4.6 L (28.1%) | L3 | Admitted-Finance |
| 4 | L4₹22.8 L+₹6.3 L (38.2%)Admitted-Finance | -21.23% | ₹22.8 L+₹6.3 L (38.2%) | L4 | Admitted-Finance |
Tender Value
₹29.0 L
EMD Value
₹57,992
Closing Date
4 Feb 2026, 3:00 pmClosed
Er. CHANDER SINGH RAWAT
The Executive Engineer (E), West Electrical Division (M-131N), PWD, 41 Rama Road, Zakhira New Delhi-15, Telephone No. 25459518, e-mail ID [email protected]
MOEI and fans, D.G. Set, Water Supply Pump, WTAC/Split A.C. Units, Fire Fighting System, R.O. Plant, High Mast Light and PA System at IGIPESS, Vikas Puri, New Delhi. During 2025-26.
2026_PWD_285698_1
75/EE(E)/West Elect Div(M-131N)/PWD/2025-26
Open Tender
Electrical Works
Works
365 days
Work
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹57,992
29 Jul 2026
27 Jan 2026
4 Feb 2026
27 Jan 2026
4 Feb 2026
27 Jan 2026
MOEI & Fans, street/security lighting Maintenance of all electrical installation with fixtures, Circuit, Submain, Distribution boards, Main boards, Security lights, by deputing technical staff on all days of month excluding Sunday & Holiday on monthly basis in General shift and as per Terms and Conditions attached:- Staff Details:-
Wireman cum operator- 1 No.
Khallasi - 1 No.
Supply of following electrical accessories for day maintenance in the existing electrical installation/wiring -rewiring etc as reqd (Labour already taken)
1.5 sq. mm ISI marked, FRLS PVC insulated, single corecopper conductor cable
4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
S.P. 5/6 A, one way switch, piano type ISI marked
S.P. 15/16 A, one way switch, piano type ISI marked
3 pin 5/6 A socket outlet, piano type ISI marked
6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
S.P. 5/6 A, one way modular switch, ISI marked
3 pin 5/6 A modular socket outlet, ISI marked
S.P. 15/16 A, one way modular switch, ISI marked
6 pin 15/16 A modular socket outlet, ISI marked
40 Amp DPMCB 10 kA breaking capacity
63 Amp DPMCB 10 kA breaking capacity
63 Amp TPN MCB 10 kA breaking capacity
3 pole MCCB, 100A, 16kA
Capacitor 2.5 Microfarad
Piano Switch type fan Regulator
Ceiling fan 1200 mm sweep ISI Rating copper winding.
40 watt LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) with 5 years OEM warranty complete etc as required.
36 Wat LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) with 5 years OEM warranty complete etc as required.
6 A to 32 A ratings, SPN MCB, “C” curve, 10 kA breaking capacity
6 A, to 32 A, ratings , SP MCB, "C" curve, 10 KA breaking capacity
Metalic Exhaust Fan 300 mm Sweep 900 RPM
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 4 sq. mm
Supplying and fixing 3mm thick phenolic laminated Sheet on the box/cover etc. as reqd.
Repair and rewinding of 5HP Submersible Pump Set with following parts complete etc as required including bye back of old dismantle material. a) rewinding Kit - 01 No. b) G.M. Bush - 3 Nos c) Rotor Sleeve SS-3 Nos d) Thrust bearing-1 No. e) Thrust plate-1 No. f) Cable Seal- 1No.
Lifting of 5/7.5 H.P. Submersible pump sets in the existing borewell along with GI Pipe, flat cable with the help of tri-port and chain pully block including testing, commissioning etc as required.
Lowering of Submersible Pump set upto 5/7.5 HP in the bore well alongwith all pipes, submersible cable etc. as reqd.
Supplying, Installation, Testing & Commissioning of wall mounted DOL pump controller in steel enclosure for 7.5 HP three phase 415V, 50Hz complete with four pole controller overload relay voltmeter, ammeter i/c testing commissioing etc as required.
Providing day to day operation and normal maintenance of RO plant of 500 LPH capacity at IGIPESS Vikas puri checking & cleaning of RO plant and water cooler with suitable chemical & all necessary preventive maintenance 9 AM to 5 PM by providing experienced & qualified staff as per terms and condition attached & as per the direction of Engineer-in- charge & site requirement.
Supply and Replament of RO membrane of Size 40"X40". (2 nos. in 6 month)
Supply and dozing of Bacteriological disinfection chemical in pure water tank of RO plant etc. as reqd. (8-9 ltr per month)
Supply and dosing of food grade Antiscalent chemical for protection of the membrane as per required quantity.(20 ltr per month)
Supply and replacement of micron cartridge filter of size 20"x2.5" 5 Microns at feed line to membrane whenever required. (4 filter per month)
Refurbishing of media/carbon filter including change of Media/carbon etc. complete as required of size 13"x 54" in existing vessels etc. complete as reqd.( 1 per annum)
Supply and Replacement of Electrical control panel with pressure switch of high and low level maintenance of Raw Water and High Pressure pump complete etc. as reqd. (as per requirement)
Supply, installation testing and commissioning of RO Membrane Housing 8" x 120" long with endcap. complete as reqd on existing skid i/c dismantling old/damage complete etc. as reqd.(as per requirement)
Repair and service of high pressure pump of 500 lph three phase 1.5 HP to feed the ro membrane at pressure more then osmotic pressure, taking into considerations flux rate flow & recovery of stainless steel construction suitable for flow rate of 1500 lph at 30 m head complete as required. (as per requirement)
Servicing and complete overhauling of WTAC/Split units after dismantling from various locations, removing of dust from condenser coil, cooling coil and chasis wherever required complete cleaning of fin condenser coil with cleaning agent of superior quality, dismantling of blower motor (if required), washing etc after dismantling of condenser motor replacement of defective parts finally applying two coats of black synthetic paint of approved brand before fixing new 5 mm./6 mm. foam sheet with adhesive testing commissioning etc. complete as reqd.
Attending day to day complaints & Routine Maintenance of WTAC, Split A.C. of different capacity installed at various sites including overhauling/servicing of machine attending complaints i/c checking & cleaning of condenser coil etc of with suitable chemical & all necessary preentive maintenance as and when reqd. by providing experienced & qualified staff as per terms and condition attache, site requirement & as per the direction of Engineer-in-Charge.
For Summer Season. AC Mechanic - 01No.
For Summer Season. Khallasi - 01 No.
Supplying and charging refrigerant gas (i.e. R-22) in the existing 2 TR capacity AC cooling unit complete with leak detection, vacuumising & rectification the leakage, pressure testing i/c brazing, providing necessary copper piping & insulation, providing suitable capacity liquid line drier etc. testing, commissioing complete as required.
S/I/T/C of compressor of the following capacity in existing AC including connection with suitable size of suction & discharge copper pipe, copper stainer, capillary, nut bolts, connections, interconnections of the electrical wiring with suitable cables, checking of leakage, pressure testing with nitrogen gas for 24 hours, vacumising, charging with suitable refrigerant gas i/c brazing etc. as required i/c buy back credit of dismantle item.
Supplying & fixing following accessories in the existing Split / window Ac Unit etc Complete as required. (Labour already included in item No. (2).
Condensing Coil
Repair PCB for 1.5 TR/2TR
Cooling Coil for 1.5 TR/2TR
Capacitor 50 - 60 Micro Farad
Starting Relay
Condenser fan blade /blower blade for WTAC /STAC 1.5/2.0
Fan Motor - ¼ To ⅛ HP (Copper)
Waste Water pipe flexible
Indoor Blower for STAC 1.5/2.0 TR
Outdoor Bracket/ Stand for STAC
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories 3as per specifications etc. as required :
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
Comprehensive Annual Maintenance contract of 125 KVA DG Set including complete Service Intervals B Check –After Every 300 Hrs./ 6Months whichever comes earlier 2 Times in 1 Year( nothing extra shall be paid) and scope of work include 1. Routine Engine Services with parts and lubricants as and when required. 2.Engineer will visit every month for general check-ups to preventive maintenance of your DG Set. 3. Unlimited Break Down calls to rectify the faults. 4. Engine Wiring Repair or Replacement including 4ST Switches and Safeties. 5. Repairing of Self Starters and Charging Alternators as and when required. 6. Repairing and Descaling of Radiators as and when required. 7. Minor Repairs of alternators i.e. Terminal Bar, Thimbles, AVR, Diodes, Rectifiers as required 8. Stand By Parts will be provided in case of failure of any i.e Self Starter, Charging Alternator, AVR etc as required. Scope not Covered in CAMC 1. If any Parts required to be replaced/repaired in case of shifting of DG Set will be charged extra as per site requirement. 2. Acoustic Enclosure / Canopy. 3. Major Overhauling if required carried out by us. 4. Top Overhauling if required carried out by us. 5. Cable From Alternator to Changeover switch. 6. Replacement of Alternator (if required) 7. Exhaust Room, Ventilation Fan & Motor, Acoustic Enclosures (shifting, painting, canopy lining, lock replacement, statutory requirements)fittings, repairs, shifting,& installing the engine or DG Set, all kind of civil and carpentry work, arranging stabilized power at site 8. Any liabilities due to accidents, mischief, strike, natural clematis-flood, fire, earthquake etc.
Credit to the Contractor on as-is-where-is basis, including dismantling, collection, loading, unloading, transportation, and all incidental charges, complete as directed by the Engineer-in-Charge.
Assorted size pvc insulated copper 1.5/4.0/6.0 Cable
assorted type of 5A switch, socket
assorted type of 15A/16 switch, socket
Assorted type of DB
Assorted type of MCB
Assorted Ceiling Fan
Assorted batten
Assorted 2X2 Fittings
Exhaust Fan
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.23 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
BOQ_378076.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .