RequiredExperience with Government Bid to RA enabled No Compressed Oxygen Gas ( 30 cubic meter ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Certification Conforming to IS:309(Latest) Yes * Whether ISI Marked No * CM/L Number - * Valid explosive license is required No * Valid explosive license No No * 1/7 Date of issue of Valid explosive license No No * Date upto which explosive license is valid No * Explosive License to be submitted to the Buyer on Demand No * The certificate of purity is to be provided along with the cylinders Yes * Test Report Availability of Test reports from Central Govt/State Govt/NABL/ILAC accredited lab to prove conformity to the specification Yes * Test Report to be submitted to the Buyer on Demand Yes * The tests for carbon monoxide
Requiredcarbon dioxide & Hydrocarbon are not required if the Compressed Oxygen is produced by Air Seperation process unless it is required by Indentor/DDO and these test shall be carrie if the gas is manufactured by any other method Yes * REQUIRNMENTS Grade NA * "Purity
Requiredpercent by volume when tested by the method prescribed in Annex A of IS:309(latest)
Requiredmin" 0 * Dew Point "The dew point or oxygen gas shall be at least 400C measured at atmospheric pressure when tested by the method prescribed in Annexure of B-2
RequiredB-3 and B-4 of IS:309(latest)" * Volume fraction of carbonmonoxide 0.88 * Volume fraction of 1.2 * 2/7 carbondioxide Volume fraction of hydrocarbons expressed as methane 34 * Impurities if any CO2
Requiredppm 22 * CO
Requiredppm 28.5 * H2O
Requiredppm 24.5 * Others
Requiredppm 34 * Packing " The gas shall be supplied compressed in cylinders The design of the cylinders
Requiredpressure of gas in the cylinders
Requiredpacking
Requiredmarking
Requiredpainting
Requiredlabelling and transport of cylinders shall be in accordance with the Gas Cylinder Rules
Required1940
Requiredwith such modifications as may be ordered from time to time by the Chief Inspector of Explosives
RequiredGovernment of India or other duly constituted authority" Yes * The quantity of oxygen gas packed in a gas cylinder shall be measured at 150C and 760 mm of Hg and shall be expressed in cubic metre Yes * Examination of Cylinders and porous substances "This shall be carried out by contractor as per Gas Cylinder Rules
Required1981 and as laid down in Red tariff No 20 " Yes * "Damage to Cylinder and parts there of- The price accepted include the prices of the damages to valves/cylinders in the prices of gases as responsibility of enroute damages and supplying of the gas in sound cylinders as per Gas Cylinder Rules
Required1981 would rest with seller in the absence of any Yes * 3/7 inspection of the same
RequiredThey will also take care of the proper loading/unloading of the cylinders and briefing/training of consignees in the handling of cylinders" "Assessment of damages at the consignee’s end- The Contractor’s representative while lifting the cylinders from the consignees end will check the cylinder/accessories etc
Requiredfor damages and intimate the same to the consignee
RequiredThe payment on account of damage parts will be made to the seller directly by the consignee separately" Yes * Specification for Gas Cylinders: Gas cylinders shall conform to Gas Cylinder Rules
Required1981
Requiredany other rules applicable currently and to specification approved by the Chief Controller of Explosives
RequiredGovernment of India Yes * Cylinders will conform to gas cylinder rules and will be duly approved by the Controller Explosives
RequiredNagpur Yes * All cylinders are required to be examined and tested periodically as per the Gas Cylinder Rules
RequiredResponsiblity for compliance with this rests with the seller
Requiredwho will carry out test as may be required Yes * All cylinders are required to be painted as and when necessary to the appropriate Yes * 4/7 colour-code specified in the Gas Cylinder Rules
Required1981
RequiredResponsibility for compliance rests with seller
Requiredwho will carry painting or as may be required under the rules It will be firm’s responsibility to possess valid Explosive Licenses for manufacturing and storing till safe delivery of Industrial Gases to the DDOs/Consignees Yes * Marking "The marking
Requiredpainting
RequiredIabelling and transport of cylinders shall be in accordance with the requirements of the Gas Cylinder Rules
Required1981 of the Government of India
Requiredwith such modification as may be ordered from time to time by the Chief Controller of Explosives
RequiredGovernment of India
Requiredor any other duly constituted authority The cylinders shall also be marked as shown in IS 1260 (Part 1) and IS 4379" Yes * "The cylinders may also be marked with the Standard Mark" Yes * "The use of the Standard Mark is governed by the provisions of the Bureau of Indian Standards Act
Required1986 and Rules and Regulations made thereunder The details of conditions under which the licence for use of the Standard Mark may be granted to manufacturers or producers may be obtained from the Yes * 5/7 Bureau of Indian Standards" Cylinders for compressed Oxygen gas shall carry a label indicating water capacity of cylinder and declared volume by the supplier at reference condition of temperature and pressure Yes * Oxygen gas shall be supplied in cylinder of 6-7 Cubic metre capacity owned by the supplier Yes * The accounting unit for Oxygen gas shall be in cubic meter at reference ambient condition of 27 degree Celsius temperature and 1 atm pressure (760mm Hg) Yes * Guarantee/Warranty The period of Guarantee/Warranty shall be 12 months from the date of receipt of stores by consignee Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.