Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.9 L+₹61,176 (2.52%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹27.5 L+₹3.2 L (13.3%)Rejected-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹28.7 L+₹4.5 L (18.4%)Rejected-Finance NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L4 | Rejected-Finance Other than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not in possession of requisite catagory |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
10 Jul 2024, 6:00 pmClosed
Garrison Engineer Air Force Thanjavur
Garrison Engineer Air Force Thanjavur
REPAIR, MAINTENANCE OF EXTERNAL ELECTRIFICATION NETWORK AND CONNECTED WORKS AT DOMESTIC AREA AF STN THANJAVUR
2024_MES_658477_1
8142/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE AF THANJAVUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Air Force
₹56,000
3 Sept 2024
8 Jun 2024
11 Jul 2024
8 Jun 2024
10 Jul 2024
22 Jun 2024
Amount
Supply and fix in replacement Off load/bypass change over switch 200 amps 415 volts 4 pole 50 Hz in sheet metal with out side handle operated complete all as specified and as directed.
Supply and fix in replacement Off load/bypass change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal with out side handle operated complete all as specified and as directed.
Supply and fix in replacement On load change over switch 200 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated complete all as specified and as directed.
Supply and fix in replacement On load change over switch 160 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated complete all as specified and as directed.
Supply and fix in replacement On load change over switch 125 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated complete all as specified and as directed.
Supply and fix in replacement On load change over switch 100 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 630 amps rupturing capacity 65 KA for 415 volts Ics = 100% Icu complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 400 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 320/350 amps rupturing capacity 36 KA for 415 volts Ics = 100% complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 250 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 200 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 160 amps rupturing capacity 36 KA for 415 volts Ics = 100% Icu complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 100 amps rupturing capacity 25 KA for 415 volts Ics = 100% Icu complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 63 amps rupturing capacity 25 KA for 415 volts Ics = 100% Icu complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole adjustable type 32/40 amps rupturing capacity 25 KA for 415 volts Ics = 100% Icu complete all as specified and as directed.
Supply and fix in replacement industrial busbar chamber in sheet metal enclosure TPN 415 volts 63 amps ,8 way on wall / ground with suitable angle iron leg with foundation complete with all incoming / outgoing cable connection complete all as specified and as directed.
Supply and fix in replacement industrial busbar chamber in sheet metal enclosure TPN 415 volts 100 amps 8 way on wall / ground with suitable angle iron leg with foundation complete with all incoming / outgoing cable connection complete all as specified and as directed.
Supply and fix in replacement industrial busbar chamber in sheet metal enclosure TPN 415 volts 200 amps 8 way on wall / ground with suitable angle iron leg with foundation complete with all incoming / outgoing cable connection all as specified.
Supply and fix in replacement HRC fuse 630 amps complete all as specified and as directed.
Supply and fix in replacement DIN open type fuse bases fixed type 630 amps complete all as specified and as directed.
M&L for detecting and taking out the faulty / burnt electric cable of any size from the loop or any other situated condition by trench out and length / distance not exceeding upto 30 RM and repair / joint the electric cable by cutting out the damaged portion and repair cable with joint kit as per suitable size and make panel functional with all incoming and outgoing cable connection including tightening loose cable / strip connections, removal of dirt,dust and carbon particles by air blower, rubbing emmery paper replacement of worn out thimbles,nut, bolt & washers , replacement of control wiring of panel etc including with excavation, R&F & removal of excavated surplus soil to a distance not exceeding 50 m complete all as specified and as directed. Note:- Additional spare parts such as Cable , cable joint kit , MCCBs will be measured & Paid separetly under relevent item of Sch 'A' as supply & fixing (ii) Replacement of burnt control wiring of panel, Cable lugs, nut- bolts , aluminium thimble etc. shall be deemed to be included in unit rate.
Supply and fix in replacement insulated Copper busbar mounted on epoxy insulators any size by using 100% copper including nut bolts washers etc complete all as specified and as directed.
Supply and fix in replacement insulated Aluminium busbar mounted on epoxy insulators any size including nut bolts washers etc complete all as specified and as directed.
Taking out hanging doors from LT panels welding the doors in position by using new hinges on MS flats including fixing/welding of new MS flats and scrapping old surface and cleaning smoothly and applied two coats of synthetic enamel paint over a coat of red oxide primer of size not more than 1.5 sqm including fixing of locking arrangement complete all as specified and as directed.
Dismantling taking out air circuit breaker any capacity calibration, servicing and replacement of fixed and movable contact points, NVC coil, auxiliary coils, auxiliary thermal magnetic relays, charge springs and greasing of all movable parts etc complete all as specified and as directed.
S&F MCB, Triple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA complete all as specified and as directed.
S&F MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through joining kit suitable for 6 to 16 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through joining kit suitable for 25 to 50 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through joining kit suitable for 70 to 150 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through joining kit suitable for 185 to 240 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink straight through joining kit suitable for 300 to 400 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink end termination kit indoor/ outdoor complete suitable for 6 to 16 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink end termination kit indoor/ outdoor complete suitable for 25 to 50 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink end termination kit indoor/ outdoor complete suitable for 70 to 150 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink end termination kit indoor/ outdoor complete suitable for 185 to 300 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply and fixing in replacement LT heat shrink end termination kit indoor/ outdoor complete suitable for 400 to 500 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed.
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area for the following size of cables with all fixing & connecting accessories including taking down old unserviceable cable complete all as specified and as directed. Note :- (i) The rate quoted by the contractor shall include the rate for cable glands and alumininium thimbles.
10 sqmm 2 core
16 sqmm 2 core.
16 sqmm 4 core.
25 sqmm 3.5 core.
35 sqmm 3.5 core.
50 sqmm 3.5 core.
95 sqmm 3.5 core.
120 sqmm 3.5 core .
150 sqmm 3.5 core.
185 sqmm 3.5 core.
240 sqmm 3.5 core.
300 sqmm 3.5 core.
400 sqmm 3.5 core.
Supply and fixing / laying in replacement of steel tubings galvanized, light grade with all fittings / fixtures along the electric cable laying in trench or pole / wall for protection of cable complete all as specified and as directed for the following sizes:-
100 mm bore
80 mm bore
50 mm bore
40 mm bore
Excavation in trenches in soft/loose soil not exc. 1.5 m wide and not exc. 1.5 m in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed. Note :- Mechanical excavation is not allowed in this Stn. Hence only manual excavation is allowed and the rate shall be quoted accordingly.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and as directed. Note:- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255 1983 and refilling in trenches for cable cushioning complete all as specified and as directed.
Removing surplus soils to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed.
Laying only for existing cable cover laid in trenches with equal to length of cable across the cable for cable protection complete all as specified and as directed.
Taking out existing LT cable of any size for re-laying / re-routing properly by disconnection from panel / pole and connected after laying with use of existing protection brick/ cover etc complete all as specified and as directed. Note:- The rate quoted by the contractor shall include the rate for aluminum thimbles excavation, RFR and removal etc.
Supply & fix Spreader terminal suitable for 4 pole MCCB upto 400Amp including with nut bolts & washer and complete connection work of cable in Panel complete all as specified and as directed.
Supply & Fix MCCB Enclosure box suitable for 4 Pole MCCB upto 250 Amps including fixing arrangement and connection complete all as specified and as directed.
Supply and fixing feeder pillar box panel,415 Volts, 50 Hz, 400 Amps capacity, out door ,factory made double door , fabricated out of CRCA sheet both inner & outer and mount on angle iron frame including incomming and outgoing connections, Digital meter and Indicating Lights , cable allay ,danger notice plate, front & back openable doors with locking arrangements, PCC foundation etc and with the followings complete all as specified and as directed:- (i) MCCB 400A,36KA, 4 Pole adjustable type-01 Nos (Incoming). (ii) MCCB 250A,36KA, 4 Pole adjustable type-04 Nos (Outgoing).
M&L for horizontal boring of holes under road, pavement, hard standing by trenchless technology using by necessary Eqpt /machine for crossing of electric cable including pipe not less than 100 mm and vertical depth n, exc. 2 mtr and horizontal dia n. exc. 200mm and including getting out excavated surplus soil to a distancenot exceeding 50 mtr and deposting whereas directed at a level complete all as specified and as directed.
BKR Enterprises
D Subramani & Sons
shalom constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .