Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.2 L+₹3.3 L (23.7%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-AOC Not Lowest |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
30 May 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA NO. GE (I) (AF)/SHL/ OF 2020-21 REPAIRS/MAINTENANCE OF HT OVERHEAD LINES, UG CABLES / INSULATORS, GOD, CABLE JOINTING KIT AND ALLIED WORKS AT HQ EAC(U), AF UNDER GE (I) (AF) SHILLONG
2020_MES_342648_1
8059/19/SHL/2020/21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHILLONG
For Enlisted Contractors Class E Category b ii and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE (I) (AF) SHILLONG
₹36,000
Yes
16 Jun 2020
4 May 2020
2 Jun 2020
4 May 2020
30 May 2020
18 May 2020
4 May 2020 - 11 May 2020
60 days
Amount
Dismantling and taking down ACSR Conductors of any size from poles complete all as directed.
Distmantling and taking down old cross arms, bracing support clamps and back plates from poles etc, complete all as directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/ loose soil, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Taking out old unserviceable HT UG cable and Supplying, laying, jointing, testing and commissioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminum conductors, 11 KV grade of , IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed of following sizes:-
120 Sqmm, 3 core NOTE :- (a) Excavation & earth work, shall be measured and paid for seprately under respective items of the BOQ. (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the BOQ (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
M & L in replacement for outdoor type heat shrinkable cable end termination jointing kit for HT 11000 Volts(Earthed) grade cable of following size complete with jointing material and accessories complete all as directed :-
95 Sqmm, 3 core
120 Sqmm, 3 core
M & L in replacement for indoor type heat shrinkable cable end termination jointing kit for HT 11000 Volts(Earthed) grade cable of following size complete with jointing material and accessories complete all as directed :-
95 Sqmm, 3 core
120 Sqmm, 3 core
M & L in replacement for heat shrinkable outdoor type straight through jointing kit for 11 KV (Earthed) grade cable of following size complete with jointing material and accessories complete all as directed :-
95 Sqmm, 3 core
120 Sqmm, 3 core
S & F in replacement Galvanised steel tubing light grade for protection of under ground cable on poles / walls/under road crossing/laid in trenches etc conforming to IS-1239 for following bore complete all as directed:-
100 mm bore (Note : Excavation & earth work shall be measured & paid separately under respective items of this Schedule).
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
Supply and laying factory made ISI marked un-reinforced precast concrete cable cover class HV type I flat of size 300mm x 180mm x 40mm complete all as specified and directed.
Supply and fixing MS structural steel work in cross arms, bracings, supports, clamps and back plates fabricated (with drilled holes hot and cold etc) from channel/angle iron sections of various size and shape FI clamps (full, half 'D' and earth clamp etc) including necessary MS bolts, nuts, washer etc and painting with two coats of aluminium paint over one coat of red oxide primer complete all as directed.
M & L in replacement for HT Pin type porcelain,vitreous, white, brown or green insulator 150mm height, 150mm dia suitable for 11000 volts grade (ISI marked) including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut complete, all as directed.
M & L in replacement for disc type insulator, porcelain, vitreous 145mm high and 255 mm dia ball and socket type, white brown or green ' Single disc' assembly for tension with tension clamps for conductors, working pressure 11000 Volts complete all as specified and directed.
Supply & fix PVC insulated aluminium conductor steel reinforced (ACSR) of suitable size for four pole and two structure for connection of gang operated switch and DO switch complete all as specified and directed. (Note : Each run of conductor shall be measured and paid.)
M & L in replacement drop out expulsion fuse single pole ,11000 Volts, above 50 & upto 100 Amps complete all as specified and directed.
S & F in replacement Lightening arresters non linear type complete with all fitting, transmission class, discharge capacity 65 KA, 11000 volts grade including clamps nut, bolts & washers and connecting to earth with GI strip/wire complete all as specified and directed.
Supply, installing, testing and commissioning of Air-break, gang operated, triple pole switch, outdoor, horizontal mounting type (ISI marked), mechanically operated, mounted on insulators for current rating upto 400 Amps complete with fuse mounts, fuse carriers and HT fuse elements and frame work with operating mechanism worked from ground level, with locking arrnagments including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply and making necessary electric connections, complete all as directed.
M & L for Servicing of complete HT VCB and Caliberation of relays through primary and secondary injection method and testing complete relays like IDMT relays / instantaneous earth fault relay of HT VCBs panels, control relay panels and carrying out protection grading setting complete all as directed for following capacities HT VCBs:- Note : Serviving and Calibration of VCBs to be carried by engaging authorised service engineer of manufacturer.
630 Amp capacity. Make of original equipment : Crompton Greaves model UNIVAC & UNIVAC- NX
400 Amp capacity. Make of original equipment : Kriloskar
Dismantling of HT cable connection both incoming & out going, removal of old unserviceable Current Transformer and M & L for Current Transformer for 11 KV HT VCB of capacity 400 Amps with Horizontal isolation with CT Ratio 50/5-5A ILV-12/28/75 KVp with class-B accuracy with STCR 13.1 KA for 1 second, frequency 50Hz including reconnection and testing complete all as specified and as directed. Make of original equipment :Kirloskar
Dismantling of HT cable connection both incoming & out going, removal of old unserviceable Current Transformer and M & L for Current Transformer for 11 KV HT VCB of capacity 630 Amps with Horizontal isolation with CT Ratio 100/5A, ILV- 12/28/75 KVp with class-I accuracy STR 13.1 KA for 1 second, frequency 50 Hz including reconnection and testing complete all as specified and as directed. Make of original equipment : AREVA
Supply only following components/parts of HT VCBs :-
HT Potential Transformer fuse cartridge suitable for HT VCB's of capacity 630Amp complete all as specified and as directed. Make of original equipment : Crompton Greaves
HT Potential Transformer fuse cartridge suitable for HT VCB's of capacity 630Amp complete all as specified and as directed. Make of original equipment : Areva
HT Potential Transformer fuse cartridge suitable for HT VCB's of capacity 400Amp complete all as specified and as directed. Make of original equipment : Kriloskar
Over current relay suitable for 110V AC supply SWIFT ENCORE, TVM with MDI, Pulse input, pulse output including necessary connection with proper size single core copper cable complete all as specified and as directed. Make of original equipment : Crompton greaves model CGI 14C
Digital type Voltmeter 0-500 volts, 3 Phase, 4 digit, high resolution LED type. Make : Securemeters/Schneider/L&T
Ammeter digital type 0-400 Amps, of class I accuracy, 0.5 VA burden. Make : Securemeters/Schneider/L&T
Indicator lamp with holder key flush mounted, LED type Red, yellow, blue.
Triping lever for VCB capacity 630Amp Make of original equipment : Areva
Triping lever for VCB capacity 400Amp Make of original equipment : Kriloskar
Triping coil for VCB capacity 630Amp Make of original equipment : Areva
Triping coil for VCB capacity 400Amp Make of original equipment : Kriloskar
Supply, installation, testing and commissioning of maintenance free chemical earthing station using 76.00mm dia, 3000mm long high tensile low carbon steel circular pipe duly filled with CCM (crystalline conductive material), molecularly bonded with copper on outer surface (minimum copper bonding thickness 250 microns) meeting the requirements of under writers laboratories (UL) 467-2007 with 250mm long copper strips of size 50X3mm, exothermally welded on top of electrode complete including augering (boring) 250mm dia hole as required for electrode in any type of soil and back filling with carbon based ground enhancing compound (GEC) (with minimum qty 50 Kg per electrode) conforming to IEEE/BS standards complete with cover including taking down exisitng earthing all as specifed and as directed. Notes:- (a) The work of earthing shall be carried out by authorised trained rep of OEM. (b) The acceptable earth resistance at earth busbar/test point shall not be more than 0.1 Ohm. (c) Loop conductors with copper strip 20mm X 3mm shall be measured and paid seperately. (d) The Earth result shall be achieved less than 0.1 Ohm. In the event of earth resistance found higher than earthing shall be re-done/rectified and no payment shall be allowed for earthing have earth resitance result more than 0.1 Ohm.) (e) The cost of excavation, earth work is included in the quoted rate. Make: JEF Techno Solution Pvt/Tercel/McML/Macmet/ Erico/ Reslow JK earth electrode.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized iron strip 32x6mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI/CI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
M & L for earthing complete with Copper earth plate 60 cm X 60 cm X 3.15 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to copper earth strip of size 20mmx3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI/CI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
M & L in replacement Earth continuity conductor galvanised iron strip 32x6mm buried in ground, to be fixed on porcelain insulator with GI nuts, bolts and washers or any other indicated situation with all accessories complete all as specified and as directed.
M & L in replacement Earth continuity conductor copper strip of size 20 x 3.00mm buried in ground, to be fixed on porcelain insulator with GI nuts, bolts and washers or any other indicated situation with all accessories complete all as specified and as directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in pedestal of poles, platforms of transformers etc including weathering, slightly rounded or chambered angle and throating including use and waste of necessary form work finishing all exposed faces of concrete even and smooth using extra cement complete all as specified and directed.
M & L in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as specified and directed
M & L for preparation of old painted surfaces by scraping, removing, cleaning, of oil, grease for 400-630 AMP capacity VCB and painting with two coats of heat resistant synthetic enameled paint over a coat of red oxide primer with spray painting arrangement including writing of SM/ MES Numbers with 15 cm high letter on the VCB body complete all as specified and directed
Supply and fixing of maintenance free dry cell battery bank of 110 Volts (55 Nos of battery connected in series- Each of 2 Volt and 200 Ah rating battery connected with suitable size of copper strip/copper wire and lugs etc) complete with all standard accessories and iron stand suitable for holding the batteries complete all as specified and directed. Make : Exide industries limited Cat part No. UPST 200Ah or equivalent model of makes AMRON/OKAYA/MICROTEK/AMCO
Supply and fixing of battery charger (for 55 Nos of battery connected in series- Each of 2 Volt and 200 Ah rating) compatible for 110V DC and 25 Amp rating complete all as specified and as directed.
mahinder electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .