HQ CWE RAJOURI
HQ CWE RAJOURI PIN-900129 C/o 56 APO
REPAIR TO HT OH LINES, UG CABLES, TRANSFORMERS AND OTHER CONNECTED WORKS AT NORTH AND SOUTH ZONE AT NAUSHERA UNDER GE 862 EWS
2023_MES_619884_1
CWE/RAJ-37/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹1 L
Yes
7 Dec 2023
21 Sept 2023
28 Oct 2023
21 Sept 2023
24 Oct 2023
5 Oct 2023
Amount
S & fix in replacement of aluminium conductor, steel reinforced (ACSR) of following sizes as in overhead conductor including fixing aluminium tapes for binding including dismantling of old conductor of any size and capacity complete all as specified and directed: - (a) 6/1 x 3.0 - Ferret (b) 6/1 x 2.59 - Weasel (c) 6/1 x 2.11 - Squirrel Note: The weight of the conductor shall be determined as stipulated in Preamble (b) on Page 406 of SSR-2010 Part-II (Rates).
S & F in replacement XLPE insulated , screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor ,11000 volts grade cross sectional area 95 Sq mm 3 core complete all as specified and directed.
S & F in replacement XLPE insulated , screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor ,11000 volts grade cross sectional area 120 Sq mm 3 core complete all as specified and directed.
Supply and fix in replacement of 11 KV air break gang operated device of rating 400 amps, 3Pole, vertical type, mechanically operated, mounted on and including 11 KV porcelain insulators and steel frame with operating machanism worked from ground level with and including GI tubing 25 mm bore light grade and providing ACSR conductor jumpers duly crimped with lugs, connected to existing 11 KV supply and testing complete all as specified and directed.
S & F in replacement of GI pipe light grade laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc all as directed of size 80 mm bore complete all as specified and directed.
Excavation in trenches n. exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out in any type of soil complete all as specified and as directed for foundation of stay, laying of cable etc.
All as per item No. 6 above, but for each additional 1.5 mtr or part there of in depth beyond the first 1.5 mtr for foundation of poles.
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 mtr above the starting point all as directed.
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm.
M&L for filling clean and dry sand cushioning for cable in trenches 15 cm thick before laying and 8 cm thick after laying of cable complete all as specified and directed. Note: Punned down thickness shall be measured.
Supply and laying of bricks class ‘B’ of size 230x115x75mm size for protection to UG cable laid flat adjoining to each other width wise complete all as specified.
M&L for plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation of PCC poles/struts as specified including necessary form work complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type C-1 using 20 mm graded stone aggregate for foundation around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
M & L for erection of steel tubular swaged poles incl foundation, & two coat of aluminium paint over a coat of red oxide zinc chrome primer in externally exposed to view portion and black bituminous painting to internal surface and portion embedded in concrete incl marking of pole No in black paint complete with cast iron base plate,finial tapper plug,bolts,nuts & screws as specified type 410 SP - 55 (11.00 mtr long) conforming to IS :1678 complete incl removing old UNSV pole of any size & type all as specified and directed. Note :- Excavation,returning and filling,removing of materials and concrete will be measured and paid separately .
S & F in replacement of stay assembly complete with all accessories and stay clamps all as shown in electrical plate No 1 of SSR Pt-1 with using stay rod of 20 mm dia, including necessary excavation, PCC, loop insulator complete all as specified & as directed.
M & L for trimming/ cutting of tree branches around HT OH line with in the distance of 2 mtr all as specified and as directed
S & F in replacement of galvanised steel wire 3.15/4 mm dia as in continuous earth wire/guard or cradle wire made to shape hexagonal/rectangular fixed on poles for HT feeder complete all as specified & as directed.
S & F in replacement cross arms, bracing, support, clamps etc made out of mild steel channel or angle section of reqd size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding, bending cold or hot in any shape or size including all fixing arrangement on HT overhead line and painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed by Engr-in-Charge.
S & F in replacement of pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 150 mm height, 150 mm dia for 11000 volts grade complete all as specified & directed.
All as per item No. 20 here-in-before, but for 33000 Volt Grade all as directed by Engr-in-Charge.
S & F in replacement of Disc type insulator, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type, white, brown or green "two in series" assembly for tension with tension clamps for conductors working pressure 11000 Volts complete all as specified & directed.
S & F in replacement of Disc type insulator, porcelain, vitreous 300 mm height and 300 mm dia ball and socket type, white, brown or green "two in series" assembly for tension with tension clamps for conductors working pressure 33000 Volts complete all as specified & directed.
Supply and fix in replacement disc type insulators, porcelain vitreous white brown or green, 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 11000 Volts complete all as specified and directed.
M & L for earthing complete with galvanised steel plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) connected to galvanized earth wire 4 mm dia by means of nuts, bolts, check nuts and washers all as shown in electrical plate No 3 connected to earthing test point including necessary earth work and PCC (1:3:6) type (using 20 mm graded stone aggregate) pit and CI cover and watering pipe 15 mm dia medium grade GI pipe for earthing lead to protect it from any mechanical damage/injury including testing on completion and taking out old unserviceable earthing complete all as specified and directed.
M & L for earthing complete with galvanised steel plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) connected to galvanized earth strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers all as shown in electrical plate No 3 connected to earthing test point including necessary earth work and PCC (1:3:6) type (using 20 mm graded stone aggregate) pit and CI cover and watering pipe 15 mm dia medium grade GI pipe for earthing lead to protect it from any mechanical damage/injury including testing on completion and taking out old unserviceable earthing complete all as specified and directed.
Supply and topping up of transformer oil of dielectric strength not less than 60 KV in the transformer / Voltage stabilizer installed at site in various location under Nowshera (South and North Zone) Garrison complete all as directed .
Draining out of transformer oil from floor/pole mounted power/ dustibution transformers and dehydrating using centrifuzing machine till its dielectric strength reaches 60 KV and filling the same into transformer complete all as directed by Engr in Charge Note:- (i) The contractor shall provide elect supply (DG set) for running centrifuzing machine. (ii) The transformer oil shall be tested with transformer oil die electric strength testing equipments before and after de-hydration of the transformer oil
Material & labour for painting to transformer indoor/ outdoor on plinth/ pole with one coat of synthetic enamel gray paint over one coat of redoxide primer by compressor spray Gun after removing all dust, rust, paint and writing SM & MES No with white paint as directed by Engr-in-Charge for following capacity of transformer ;-
(a) 25 KVA to 100 KVA transformer
(b) 160 KVA to 315 KVA
(c) 3.15 MVA capacity
M & L for painting to HT electric poles 11 mtr with two coat of synthetic enamelled aluminium paint incl preparation work including marking of poles complete all as specified and directed
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for out door end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified & directed.
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all specified & directed.
Supply and fixing in replacement of lightning arrestor expulsion type complete with all fittings transmission class, discharge capacity 65 kilo Amps suitable for 11000 Volts complete all as directed by Engr-in-Charge.
Material and labour in replacement for high tension lightning arrestor, expulsion type suitable for 33 KV with all fittings of transmission class, discharge capacity 65 Kilo Amps and testing complete all as specified and directed.
Testing calibration of HT VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and resetting of relay and proper alignment of mechanical system through authorised dealer for smooth functioning and VCB should be tripped at any type of fault developed in feeders complete all as specified and directed by Engr in Charge. Note :- (a) Contractor will submit primary and secondary test report at the time of calibration of HT VCB duly signed by the technician ( b) replacemnt of unservicable item will be measured and paid separately.
Supply & fixing in replacement 1250 Amp Vacuum interrupter complete all as specified & directed.
Supply & fixing in replacement AM 96 x 96 mm with MS plate with accuracy 1.00 with CT s Make - Electric field / ABB/ CG / Schneider
supply & fixing in replacement VM 96 x 96 mm with MS plate with accuracy 1.00 with CT s Make - Electric field / ABB/ CG / Schneider.
supply & fixing in replacement Spring charging motor 80W,220V, AC/DC Make - Electric feild / ABB/ CG / Schneider.
Supply & fixing in replacement LED lamp 30 V DC complete all as specified and directed.
Supply & fixing in replacement breaker control switch as per existing type complete all as specified and directed.
Supply & fixing in replacement Master trip relay & digital display relay for VCB/HT panel complete all as specified and directed. Make -Ashida/ Schneider/ABB
Supply & Fixing in replacement Limit switch Make - Electric field / ABB / CG / Schneider
Supply & fixing in replacement Drive insulator complete all as specified and directed. Make - Electric field / ABB / CG / Schneider.
Disconnecting of LT and HT connection carefully from the existing transformer of capacity 50 KVA to 160 KVA, 11KV/433 volts of any make/type, taking down/remove from existing site, transporting the transformer from various locations to the workshop for carrying out repair work, opening of top cover and decanning of transformer oil, checking of connections internally,dismantling of core and remove HT/LT coil for replacement, replacing burnt HT and LT bushing and studs and soldering and brazing the connections including removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding, tightening of all connections etc, cleaning of oil tank and rectification of leakage problem and renewal of all gaskets and assembling and filling back of tranformer oil (after filtration and dehydration of transformer oil at work shop for required value) including top up of transformer oil upto required level and after repair and transporting back to the same site including installation and connecting of HT and LT connections of transformer and charging the transformer including testing it upto proper functioning complete all as specified and directed by Engineer-in-Charge.
Note : (i) The contractor will take down and refix the transformer at site at various location as directed by Engineer-in-charge. (ii) The expenditure incured for transportation of transformer from site to workshop and back is deemed to be included in the quoted rate. (iii) T & P required for taking down and refixing of transformer deemed to be included in the rate quoted by contractor, Rewinding of HT & LT coils and oil shall be measured and paid separately under relevant items and cost of gaskets, nuts and bolts etc. will be deemed to be included in this above item quoted rate. (iv) Repair/ rewinding of transformer carried out by authorized workshop only. (v) Copper winding material required for maintenance measured and paid separetely in respective items. Cost for all other items used for above are deemed to be included in the quoted rates. (vi) Cost for dehydration/ filtration and topup of transformer oil for repaired transformer deemed to be included in the quoted rate.
All as per the description of srl item No 48 above but capacity of transformer more than 160 KVA and upto 315 KVA.
M&L for Replacement of burnt out /unserviceable transformer HT coil/winding with super enameled copper winding wire of suitable size of gauge and turns as per original winding of transformer including all insulating papers and material required for making of coil complete all as specified and as specified and directed by EIC.
M& L for Replacement of burnt out /unserviceable transformer LT coil/winding with super enameled copper winding wire of suitable size of gauge and turns as per original winding of transformer including all insulating papers and material required for making of coil complete all as specified and as specified and directed by EIC.
Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for primary (HT) side of transformer capacity 50 KVA to 160 KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed. Note:- This item shall not be applicable for item No 48 & 49
Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for primary (HT) side of transformer capacity above 160 to 315 KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed. Note:- This item shall not be applicable for item No 48 & 49
Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for secondary (LT) side of transformer capacity 50KVA to 160 KVA , 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed. Note:- This item shall not be applicable for item No No 48 & 49.
Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for secondary (LT) side of transformer capacity above 160 to 315 , 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed. Note:- This item shall not be applicable for item No No 48 & 49
M&L for replacement of U/S breather with New breather apparatus set suitable for various transformers of capacity up to 25 KVA to 315KVA including refilling with new silica gel to the required level to various transformers at different locations.
Supply and fix in repairs silica gel component suitable for breather assembly of outdoor type transformer upto 315 KVA capacity, complete all as specified and directed.
M & L for replacement of anti climbing device spikes type fabricated out of M.S bars ( Round , Square and flat ) including nuts, bolts, washersand welding in two halves made to shape to suit the cross section of the pole.
M & L for replacement of danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, bigures and conventional shull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of HT 25 x 20 cm for 11000V / 33000V complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for indoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
All as per the description of srl item No 60 above but for 120 sqmm size cable complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed.
M & L for repair & servicing of RTCC panel including replacement of all spares such as switches, meters, indicators, relays, etc as required at site to make the panel to work upto the satisfaction of Engr-in-Charge. Note: Cost for all materials and spares used to repair the panel are deemed to be included in the quoted rate.
S & f in replacement of isolator suitable for 33 KV, three pole, current rating upto 400 to 1600 Amps including insulators as required for fixing of isolator set fixing on steel base structure for smooth running of supply without rising temprature complete all as specified and directed.
Dismantling the existing broken/ damage platform and M & L for construction of platform of size 3000x2500x1500mm including all materials and civil works with brick work, rendering 15mm thick CM 1:4, PCC 1:5:10 (40mm graded stone) for foundation, 1:3:6 for base of foundation including angle iron of size 40x40x5mm, cutting, welding and all fabrication works, fencing with GI wire mesh around the platform with gate of suitable size alongwith all required items such as nuts, bolts, washers, etc., plastering of whole platform and painting for installation of transformer all as shown on drawing CEDZ/TD-1129/96 sheet 1/2 complete all as specified and directed.
Material and labour for painting of HT 4 pole structure consisting of steel tubular poles, bracing, cross arms, channels,clamps, supports, nuts, bolts with two coats of Silver paint over a coat of red oxide primer after preparing the existing external surfaces including making alternate strips each of 30 cm height with black and red synthetic enamel paint upto 1.20 mtr height from top of PCC copping, complete all as specified and directed.
Material & labour for painting of HT two pole structure consisting of steel tubuler poles and connected steel sections such as bracing, cross arms , channels, supports, clamps , nuts , bolts of any type with two coat of aluminium paint over a coat of red oxide primer after preparing the old painted external surfaces including making alternate strips each 30cm with black and red synthetic enamel paint upto 1.2m height from ground level complete all as specified and directed .
Supply & install battery bank with 16 Nos of 2V maintenance free VRLA type sealed high impact polyprophelene copolymer container flame retardant batteries 100Ah including all fixing arrangements and connection complete including depositing old/ unserviceable battery bank to MES store all as directed at site
Disconnecting primary and secondary connections carefully from the existing transformer of capacity 3.15MVA, 33/11KV of any make/type, taking down/remove from existing site by heavy duty crane, transporting the transformer to the workshop for carrying out repair work, opening of top cover and decanning of transformer oil, checking of connections internally, replacing primary & secondary bushings and studs, soldering/ brazing the connections including removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding, tightening of all connections, repairing & testing of relay & meters etc, cleaning of oil tank and rectification of leakage problem and renewal of all gaskets, assembling and filling back of tranformer oil (after filtration and dehydration of transformer oil upto required value) including top up of transformer oil upto required level after repair and transporting back to the same site including installation and connections, charging and testing it upto proper functioning complete all as specified and directed by Engineer-in-Charge.
Note : (i) The contractor will take down and refix the transformer at site at various location as directed by Engineer-in-charge. (ii) The expenditure incured for transportation of transformer from site to workshop and back is deemed to be included in the quoted rate. (iii) T & P required for taking down and refixing of transformer, cost of gaskets, nuts and bolts etc. are deemed to be included in the rate quoted by contractor. (iv) Cost for dehydration/ filtration and topup of transformer oil for repaired transformer deemed to be included in the quoted rate.
M & L for installation of sign board of size 2X0.5 mtr for MRS including all works such as printing as directed, fabricating, wiring with light fittings, switches and connection and all connected works and written as "MES MAIN RECEIVING STATION 33/11KV NAUSHERA" complete all as specified and directed.
M & L for installation of sign board of size 1.5X0.5 mtr for 80 Bde substation including all works such as printing as directed, fabricating, wiring with light fittings, switches and connection and all connected works and written as "MES 80 BRIGADE 11KV SUB STATION NAUSHERA" complete all as specified and directed.
vijay kumar gupta and co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .