Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.3 LAccepted-AOC MOGA | L1 | Accepted-AOC Contract Award | |
| 2 | L2₹54.8 L+₹50,423 (0.93%)Rejected-AOC | L2 | Rejected-AOC Being L2 |
Tender Value
₹52.0 L
EMD Value
₹1.0 L
Closing Date
19 Jul 2021, 5:00 pmClosed
Executive Engineer
Executive Engineer, Water Supply and Sanitation, Division, Fazilka Room No. 410, 3rd Floor Block A, District Administration Complex, Fazilka
AUGMENTATION OF WATER SUPPLY SCHEME VILLAGE WALLE SHAH HITHAR (MH-PC) BLOCK FAZILKA DISTT. FAZILKA (UNDER PRWSSIP 1a(iii)/JJM) Tubewell, OHSR, Civil and Other Works as per DNIT.
2021_WB_67726_1
WB08(2021) WSS Village Walle Shah Hithar
Open Tender
Civil Works - Water Works
Item Rate
300 days
Fazilka
Please refer Tender documents.
6 documents required · 6 mandatory
₹1
₹1.0 L
Off of CE (C) WSS Deptt., Patiala
18 Oct 2021
1 Jul 2021
20 Jul 2021
1 Jul 2021
19 Jul 2021
1 Jul 2021
13 Jul 2021
Amount
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested ,equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. b) Boring with 250mm id Housing pipeUpto 110 m depth BGL.
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. (c) 200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness
Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore. i) 200mm Steel Strainer (slot size 0.15mm) 6.30 mm thickness
Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect. (b) 200mm internal diameter
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. (c) 200mm internal diameter
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. (c) 200mm internal diameter (weight 33.6 kg per metre) 6.40 mm thickness
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. (c) 200mm internal diameter
Development and Stabilizing of the tubwell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. (a) Capacity of Air compressor 300 cfm at 250 PSI
Development and Stabilizing of the tubwell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
Collection fo sand sample for seive analysis test.
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
Providing for sterilization of tubewell with sodium hyprochloride/chlorination of well as per IS code 2000-2019
Telescopic trail Boring with 250 & 200 mm i/d MS Casing Pipes upto and withdrawing the same after completion of Tubewell is required to be Abandoned on the basis of non Availability of Portable water.
Constructing one No. OHSR of 50 KL (50000 litres) Capacity with sill level not less than 17.00m and height upto FSL 20.00 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single manhole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing C.I. D/F expansion joints conforming to (IS-1536-1989) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed standard drawing. Duck foot bends, Conforming to ISI - 13382 and C.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow CI double flanged pressure pipes horizontally cast in sand moulds as per IS 7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil is greater than or equal to 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling within lead of 5 km, including overflow haudi complete in all respects.(including carriage) Note: Design to be submitted by the contractor.
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation
Cement Concrete 1:8:16 with 40mm gauge stone aggregate to be used instead of brick ballast.
First Class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth
Damp proof course 4cm thick of cement concrete 1:2:4 with two coats of bitumen 20/30 penetration @ 1.65 Kg per Sqm laid hot and sanded
20mm thick cement plaster damp proof course 1:3 with two coats of bitumen at 1.65 kg per Sqm laid hot and sanded
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4meters above plinth level
Extra for additional storey upto 4mtrs. Above the top of structural roof of lower storey
115mm thick wall laid in cement sand mortar 1:4 without reinforcement in super structure
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Reinforced cement concrete M-20 with cement @375/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in superstructure.
Terracing consisting of tiles 22.86cm×11.43cum×3.83cm laid over25mm mud plaster, 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot @ 1.65Kg. Per Sqm on top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
Congolmerate floor 40mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm sand or stone filling for plinth protection.
Conglomerate floor 50mm thick cement concrete rate 1:2:4 on 100mm thick cement concrete 1:8:16with stone aggregate 40mm gauge and 100mm sand filling
12.5mm thick cement plaster 1:4
12.5mm thick plaster in 1:4 under side of ceiling
Hollock wood doors shutter windows including Hinges, Screws, Chocks Cleats, Stops and Cords etc. complete fixed in position (double Leaf) @ Paneled glazed or glazed and paneled
Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them)
Kiln seasonal Hollock wood cup board chowkats including iron hold fasts, iron hinges corner straps, wooden knobs or handles fixed in position (Size 45 x 60mm).
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Applying priming coat with metal primer on new steel or iron work including preparation of surface. and Painting two or more coats with aluminum paints excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work
Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a) UPVC 110 mm Coupling /Sockets
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. a) UPVC 110 mm bend
Steel work fixed independently without connecting plates including cutting hoisting and fixing in position
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete a) Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebateweighing 3.43 kg per meter.
Wrought iron and mild steel grills (made of 20 wide and 6mm thick flat )
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15cm layers including ramming watering and consolidating lead upto 30 meters.
White washing 3 coats inside of pump chamber
Finishing walls with cement based water exterior paint such as snowecem, robbiacem etc. on old work one coat to give an even shade
Providing and fixing of Glass strips 4mm thick in floors 50mm wide
Providing and fixing of Glass strips 4mm thick in floors 40mm wide
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of Paris and chalk mitti including finishing the surface to the required finish complete. Inside pump Chamber
Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade.
Supplying & fixing glass panes 4mm including special metal sash putty of approved make.
Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- i) b Wiring fan point (With fan box)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- ii) Wiring light point
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- iv) Wiring 6Amp. wall socket point
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- vi) Wiring 16/20Amp. power plug control point
G.I. EARTHING: (xiv) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). a) Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14Metre in length)
SHEET METAL IRON CLAD SWITCHES: Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- i) ICDP Switch 32amp., 415volts
Providing & fixing of ceiling fan of reputed make such as Crompton or equivalent
Providing & fixing of CFL electric Bulbs
Construction of One No. Toilet at Water Works.
Providing, Stringing out PVC pipes 10 kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width Complete in all respect. (Mechanically ) (10kgf/ cm2) Pressure 110 mm o/d PVC pipe (35+15=50 mtr.)
CONSTRUCTION OF V-NOTCH HAUDI. (size 1.80 m x 0.90 m) excluding cost V-notch as per standard design & drawings of public health department.
Providing, Stringing out PVC pipes 6kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width. (Mechanically ) (6kgf/ cm2) Pressure xii) PVC pipe 63mm o/d PVC 6 kg/cm2
Providing, Stringing out PVC pipes 6kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width. (Mechanically ) (6kgf/ cm2) Pressure xiv) PVC pipe 90mm o/d PVC 6 kg/cm2
Providing, Stringing out PVC pipes 6kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width. (Mechanically ) (6kgf/ cm2) Pressure xv) PVC pipe 110mm o/d PVC 6 kg/cm2
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position. Manually Excavation 63mm PVC Pipe
Contractor shall quote rates only for dismantling of metalled road and back filling with excavated earth, fully compacted. The restoration of the metalled road to its original condition will be done by the concerned department I.e PWD (B&R)/PMB/ Panchayti Raj. PVC pipe
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). A Class PN-1 as per ISI a) 80mm i/d Sluice Valves flanged
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). A) Class PN-1 as per ISI b)100mm I/d
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. A) 0.6x0.6 mtr
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. B) 0.9x0.9 mtr
Repair of existing RO Plant of capacity 500 LPH i) Membrane
Repair of existing RO Plant of capacity 500 LPH ii) Multimedia Filter
Repair of existing RO Plant of capacity 500 LPH iii) UV Lamp
Repair of existing RO Plant of capacity 500 LPH iv) Antiscallents
Repair of existing RO Plant of capacity 500 LPH v) Cartiage of Filter
Repair of existing RO Plant of capacity 500 LPH vi) Dosing Pump with Lime Dosing
Repair of existing RO Plant of capacity 500 LPH vii) Low Pressure Pump
Repair of existing RO Plant of capacity 500 LPH viii) High Pressure Pump
Water Connection Providing proposed water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d=2.50 mtr B- Class as per CSR 28.36 (A),( Above GL), Prov. & fixing MDPE pipe 15mm i/d with specials 2.00 Mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b).
Water Meter Providing,fixing & jointing multijet water meter of approved make as per IS:779/94 in G.I.Pipe line including cutting and threading pipe including cost of water meter but excluding cost of specials, Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages, 15mm i/d Brass Ball valves of G.I. Nipple 15mm x 150mm, Supply of G.I. Nipple 15mm x 100mm, Supply of G.I. elbow 15mm i/dia ISI Marked Providing, fixing and jointing Union Couplings in G.I. Pipe Lines Providing & Fixing G.I. Hooks comlplete in all respect.
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications. Along with 200ltr of sodium hypochlorite in container.
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of capable of delivering 246 LPM against a head of 41.00mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 65 mm & length 18 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 50 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2005 complete in all respects i) Motor with Pump
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of capable of delivering 246 LPM against a head of 41.00mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 65 mm & length 18 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 50 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2005 complete in all respects ii) Panel Board
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of capable of delivering 246 LPM against a head of 41.00mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 65 mm & length 18 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 50 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2005 complete in all respects iii) Cable (Size/Cost) 2.50mm2
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of capable of delivering 246 LPM against a head of 41.00mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 65 mm & length 18 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 50 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2005 complete in all respects iv) Column Pipe (G.I)( Size/Length) (65mm i/d)
Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Drawings D-16
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-9
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects including carriage of material
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-11
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-12 including carriage of material
Construction of masonry gate pillar including cost of MS Steel gate size 1.37 m x1.22 mtr. as per standard Drawing-10.
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-15
Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-14
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish Carriage of material excluding initial lead of 5 Km a) Fine Sand From Jalalabad (Av. Lead 65 Km)
Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish Carriage of material excluding initial lead of 5 Km b) Course Sand From Pathankot (Av Lead 330 Km.) i) up to 300 km
beyond 300 km (330-300=30 km) (30x1.50km = 45
Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish Carriage of material excluding initial lead of 5 Km c) Bajri / Gatka From Pathankot (Av Lead 330 Km.) i) up to 300 km
beyond 300 km (330-300=30 km) (30x1.50km = 45
Operation & Maintenance of water supply for 3 months after completion of work including cost of alum, liquid chlorine etc. excluding electricity charges.
JASBIR SINGH GOVT CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .