| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 CrAdmitted-Finance 3RD FLOOR KAY M PLAZA G S ROAD GANESHGURI KAMRUP ASSAM 781006 UDYAM AS 03 0002331 | KAMRUP METRO | ASSAM | 781006 | ₹33.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹34.6 CrAdmitted-Finance 1ST FLOOR 239 8 KOTHAI HOUSE L J ROAD SHIVAJI PARK MAHIM MUMBAI 400 016 | MUMBAI | MUMBAI | MAHARASHTRA | 400016 | ₹34.6 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical 201 ROYAL ARCADE DR B BARUAH ROAD ULUBARI GUWAHATI 781007 | GUWAHATI | KAMRUP METRO | ASSAM | 781007 | - | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | ASC Power Private Limited L2 | Industrial Systems LLP L1 |
|---|---|---|---|---|---|
| 1.00 | Supplying, Installation , Testing and Commissioning of stadium lighting conforming to national standard suitable for 960+/- 50W LED luminaire complete with accessories maintaining Horizontal lux of 750for Football field(70Mx110M) & Cricket Pitch with uniformity ( Min/Aveg. =0.7) and 500Lux for Cricket field (65M radius) with Uniformity (Min/Aveg.=0.6) and (Min/Max =0.4)as per FIFA Guideline as specified and directed by the department. | 840 | Each | 1,89,120 ₹15.9 Cr | 1,88,565 ₹15.8 Cr |
| 2.00 | Supplying,errection, installation of 32 +/-3 M Stadium Mast up to the top of fixed Head frame suitable for30 nos. LED light fixtures with its all accessories. Mast shaft shall be in 4 section hot dip galvanised and suitable for wind velocity as per IS 875 and thickness of GI coating should withstand climate of Assam, it shall also include acessories double drum winch suitable for human rider & its control gear boxes. The mast shall have an integral power tools installed inside the base compartment for its operation including LED Aviation light, Main trailing Cable, Lightening arrester etc. as per the specification of the design parametres and directed by the department. | 28 | Each | 21,78,550 ₹6.1 Cr | 21,54,000 ₹6.0 Cr |
| 3.00 | Supplying, fitting & fixing of Foundation Bolts manufactured from special steel along with nuts and washers, anchor plate and templates as per the design specification and as directed by the department. | 28 | Each | 1,48,150 ₹41.5 L | 1,45,000 ₹40.6 L |
| 4.00 | Supplying, Installation , Testing and Commissioning of Suitable Manrider / Power Lift for acessing the head frame suitable and safe for load carrying for 300 Kg as per design and as directed by the department. | 21 | Each | 2,41,920 ₹50.8 L | 2,27,000 ₹47.7 L |
| 5.00 | Construction of Foundation for errection of Mast as per design of the Company and as directed by the deptt.the foundation may vary depending on the soil condition as per site. | 28 | Each | 3,63,600 ₹1.0 Cr | 3,12,540 ₹87.5 L |
| 6.00 | Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. "C Series
(ABB, Schneider MG, legrand, Hager make) ,6 to 32A | 840 | Each | 570 ₹4.8 L | 642 ₹5.4 L |
| 7.00 | Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.36KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 63A | 18 | Each | 15,820 ₹2.8 L | 17,233 ₹3.1 L |
| 8.00 | Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.36KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 100 A | 6 | Each | 15,850 ₹95,100 | 16,432 ₹98,592 |
| 9.00 | Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.36KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 160A | 26 | Each | 19,480 ₹5.1 L | 20,700 ₹5.4 L |
| 10.00 | "Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.36KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 250A | 38 | Each | 25,210 ₹9.6 L | 26,410 ₹10.0 L |
Tender Value
₹32.9 Cr
EMD Value
₹65.9 L
Closing Date
21 Oct 2020, 3:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Installation of FloodLights in 7 (Seven) stadiaof the StateViz. Kamrup(M), Dibrugarh, Tinsukia, Jorhat, Mangaldai, Sonitpur and Karimganj
2020_PWBNH_18793_1
CE/BLD/ELECT/15/2001/304 Flood Lights
Open Tender
Civil Works - Building
545 days
Assam
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,500
Assam State Road Board Maintenance (Road) Fund
₹65.9 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
21 Nov 2020
25 Sept 2020
21 Oct 2020
28 Sept 2020
21 Oct 2020
28 Sept 2020
14 Oct 2020
Amount
Supplying, Installation , Testing and Commissioning of stadium lighting conforming to national standard suitable for 960+/- 50W LED luminaire complete with accessories maintaining Horizontal lux of 750for Football field(70Mx110M) & Cricket Pitch with uniformity ( Min/Aveg. =0.7) and 500Lux for Cricket field (65M radius) with Uniformity (Min/Aveg.=0.6) and (Min/Max =0.4)as per FIFA Guideline as specified and directed by the department.
Supplying,errection, installation of 32 +/-3 M Stadium Mast up to the top of fixed Head frame suitable for30 nos. LED light fixtures with its all accessories. Mast shaft shall be in 4 section hot dip galvanised and suitable for wind velocity as per IS 875 and thickness of GI coating should withstand climate of Assam, it shall also include acessories double drum winch suitable for human rider & its control gear boxes. The mast shall have an integral power tools installed inside the base compartment for its operation including LED Aviation light, Main trailing Cable, Lightening arrester etc. as per the specification of the design parametres and directed by the department.
Supplying, fitting & fixing of Foundation Bolts manufactured from special steel along with nuts and washers, anchor plate and templates as per the design specification and as directed by the department.
Supplying, Installation , Testing and Commissioning of Suitable Manrider / Power Lift for acessing the head frame suitable and safe for load carrying for 300 Kg as per design and as directed by the department.
Construction of Foundation for errection of Mast as per design of the Company and as directed by the deptt.the foundation may vary depending on the soil condition as per site.
Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. "C Series (ABB, Schneider MG, legrand, Hager make) ,6 to 32A
Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.36KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 63A
Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.36KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 100 A
Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.36KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 160A
"Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.36KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 250A
Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, neutral adjustable with earth fault protection Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 50KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 400A
Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu, adjustable Over Load and Short Circuit setting, neutral adjustable with earth fault protection Without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 50KA (ABB, Schneider, legrand, L&T, Siemens, C&S make), 630A
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the dep't .
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the dep't .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the dep't .
Supplying & laying of 25x5 size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the dep't.
Supplying & laying of 25x5size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the dep't.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 4 Core A2XWY A2XFY, 35.00 Sq. mm.4 Core armoured U.G. cable
"Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 4 Core A2XWY A2XFY, 95.00 Sq. mm.4Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 4 Core A2XWY A2XFY, 120.00 Sq. mm.4Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 4 Core A2XWY A2XFY, 300.00 Sq. mm.4 Core armoured U.G. cable
"Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 4 Core A2XWY A2XFY, 400.00 Sq. mm.4 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make), 4 Core A2XWY A2XFY, 35.00 Sq.mm 4 Core U.G. cable in 50mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
"Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make), 4 Core A2XWY A2XFY, 95.00 Sq.mm 4 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
"Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make), 4 Core A2XWY A2XFY, 120.00 Sq.mm 4 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
"Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make), 4 Core A2XWY A2XFY, 300.00 Sq.mm 4 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
"Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make), 4 Core A2XWY A2XFY, 400.00 Sq.mm 4 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . Core - 1, A2XWY; 4x240 Sq.mm single core armoured cable
"Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the dep't. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . Core - 1, A2XWY; 4x300 Sq.mm single core armoured cable
Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). Core - 3, 2XY; 4.00 Sq.mm 3 Core Unarmoured
Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 70.00 - 150.00 Sq.mm., 3/ 3.5/ 4 Core cable.
Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 185.00 - 300.00 Sq.mm., 3/ 3.5/ 4 Core cable.
Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 400.00 Sq.mm., 3/ 3.5/ 4 Core cable.
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 100 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 250 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying and erection of H.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/3.15 mm dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 75 mm x 40 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised Angle of 50 mm x 50 mm x 60 x 5000 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of 11 KV T Cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and erection of L.T. Pin insulators with G.I. pin complete with blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of L.T. Shackle insulators with shackle strap complete with blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
Supply and erection of 15/ 6 amp aerial fuse complete as required and as directed by the department.
Supplying and fixing of 50 mm x 5.6 metre. hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) (including accessories 50mm x 50mm x6mm angle iron bracket on the wall and 75 mmx 90mm shackle insulator with straps and 7/3.15 sq mm G.I.stay for house service connection as approved by the Depts. required and as directed by the department.
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
Supplying and fitting fixing pole clamp complete as required and as directed by the department.
Supplying and fitting fixing of P.G. clamp for Racoon conductor complete as required and as directed by the department.
Supplying and string up AAAC Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department.
Supplying including installation of 4' dia. C.I. earth pipe complete as required and as directed by the department.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the dep't. (BANSAL/SRP / Valmont / PARUTHI ENGR make) 410 SP 47 Length of pole = 10.00 metre., Length of sections, Bottom = 5.20 M, Middle = 2.40 M, Top = 2.40 M, Out side dia. & Thickness Bottom = 193.70 x 5.40 mm, Middle =165.10 x 4.50 mm, Top =138.70 x 4.50 mm
Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the dep't. (BANSAL/SRP / Valmont / PARUTHI ENGR make) 410 SP 66 Length of pole = 12.00 metre., Length of sections, Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 219.10 x 5.60 mm, Middle =193.7 x 4.85 mm, Top =165.10 x 4.50 mm
Supplying including installation of 11KV CT/PT combine metering system complete as required and as directed by the department. (Or as per APDCL)
Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV) "TECHNICAL DATA CJ100D5P GENERATOR SET SPECIFICATIONS 100/80 3. No. of Phases. 3 phase. 4. POWER FACTOR 0.8 LAG JACKSON ENGINE SPECIFICATION. 1. make). Cummins 2. Model. 6BTA5.9G5 3. No. of Cylinders. 6 4. Aspiration. TURBO CHARGED after COOLED 5. Cooling. Water Cooled. 6. Governor. Mechanical 7. Battery Capacity Rating. 12 Volt. 8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 16.9 ALTERNATOR SPECIFICATION. 1. make). CGT (STAMFOR 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3" WITH AMF CONTROL PANEL
Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV) TECHNICAL DATA CJ250D5P GENERATOR SET SPECIFICATIONS 250/200 3. No. of Phases. 3 phase. 4. POWER FACTOR 0.8 LAG JACKSON ENGINE SPECIFICATION. 1. make). Cummins 2. Model. 6CTA-8.3-G4 3. No. of Cylinders. 6 4. Aspiration. TURBO CHARGED AIR TO AIR COOLED 5. Cooling. Water Cooled. 6. Governor. Electronic 7. Battery Capacity Rating. 2x12 Volt. 8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 40.8 ALTERNATOR SPECIFICATION. 1. make). CGT (STAMFOR 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3 WITH SRANDARD CONTROL PANEL
Load Security to be Paid to APDCL
Cost involvement in Construction of Sub-Station, Supervision charge, Storage Charge, Contingency Charge etc. to be paid to the APDCL.
Supplying including installation testing and commissioning of 100kVAr, 440V APFC Panel Non-Compartmentalized Type, Free Standing, Floor Mounted rated Output 100kVAr rated Voltage 440V rated Frequency 50Hz Number of phases 3 Phase Switching Option Auto-Manual ENCLOSURE DETAILS Material CRCA Thickness of sheet steel Frame & Doors: 2.0mm, Partitions: 1.6mm, Gland plate: 3.0mm Dimensions W x H x D (mm) 800 x 1800 x 600 (Approx) + (250 mm for plinth & fan hook Ingress Protection IP 42 Installation Type Indoor Cable Entry Bottom Colour RAL 7035 - Light Grey BUSBAR DETAILS Material Aluminium Cross Section (mm) 40 x 10 x 1 Run Bus bar Supports DMC Moulded CAPACITORS Heavy Duty @ 440V No of Steps 5 Incomer MCCB, 200A, 36kA CVS Type Switching Capacitor Duty Contactors Step Protection MCB/MCCB APFC RELAY INCOMER MCCB, 200A, 36kA CVS Type 1 Digital Volt - Amp Freq meter 1 Phase Indicating Lamps (L1, L2, L3) 3 Current Transformer - 200/5A 3 APFC Relay 1 Fans 1 Control Circuit Protection - MCB 2 Step Indicating Lamps 10 On / Off push buttons 10 Step protection - MCCB, CVS Type, 25kA - 100A 1
Supplying including installation testing and commissioning of APFC Panel Non-Compartmentalized Type, Free Standing, Floor Mounted with Super Heary duty capacitor & MCCB rncomer No of Stage 4 KVAR 35& 50
Construction of Transformer Pad as specified and directed by the department.
Construction of Generator Pad as specified and directed by the department.
Construction of Fencing in the Feeder Panel for protection as specified and directed by the department.
PLINTH AREA RATES FOR ASSAM TYPE BUILDING. Construction of Generator & Electrical Control room 5m x 8 m as specified and directed by the department.
Testing of entire installation, Aiming of light fixtures and light level measurement with NABL certified Lux meter (Post Installation) and submission of final aiming sheet to the Department.
Supplying with fitting fixing and testing of the following electrical components for autochangeover of power from Normal power supply to D.G Power supply as specified and directed by the department.( Make- Schneider Make).
Supplying with fitting fixing and testing of EARTH LEAKAGE PROTECTION to protect the earth leakage in the Mast system as specified and directed by the department.(Make- Schneider Make, Model No-LV429213).
Annual Operation and Maintenance Charges……...Prevevtive maintenance and on service call for a period of five years including defect liability period. During Defect liability period ( One year from the date of handling over) spares will be supplied free of cost by the contractor.) However spares will be on chargable basis after DLP.
Submission of General Arrangement Illumination design before execution of work as required for 7 nos. of stadium considering National Standard sporting event ( average level of Illumination > 750 Lux in Horizontal ) for further necessary approval from the Department before execution of the work.
ASC Power Private Limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
BOQ_29015.xls
BOQ • 0.34 MB
FOB.pdf
Additional Documents • 0.00 MB
SBD.pdf
Tender Documents • 0.58 MB
Download all tender documents and submit your bid