Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.9 L+₹5.4 L (19.0%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹37.6 L+₹9.1 L (31.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical Not meeting eligibility criteria. Documents have not submitted as per NIT. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not meeting eligibility criteria. Documents have not submitted as per NIT note 1 on page No. 7 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Feb 2022, 6:00 pmClosed
GE Bhopal
GE Bhopal, Bairagarh, Bhopal
REPAIR MAINT OF INTERNAL ELECTRIFICATION AND FIXTURES IN OTM ACCN AND REPAIR REPLACEMENT OF UNSV LT PANELS AND ALLIED WORKS AT SI LINES UNDER GE BHOPAL
2022_MES_502111_1
8841/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE Bhopal
As per tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Bhopal
₹70,000
Yes
9 Mar 2022
17 Jan 2022
12 Feb 2022
17 Jan 2022
7 Feb 2022
31 Jan 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc, complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in and including non metallic rigid PVC casing capping not less than 25mm base size with all fitting and fixing accessories including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs, sunken sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators, etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No 2.00 above, but for one light point controlled by two way switches complete all as specified and directed .
All as per BOQ item No 2.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No 2.00 above, one 3 pin 5 Amps socket outlet point controlled by one switch on same board with other switches, complete all as specified and directed.
All as per BOQ item No 2.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination for 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly, complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit, concealed (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover, complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No 7.00 above, but for one light point controlled by two way switches complete all as specified and directed .
All as per BOQ item No.7.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No 7.00 above, one 3 pin socket outlet 5 Amps on same board all as specified and directed.
All as per BOQ item No.7.00 above, but 3 pin socket outlet 15 amps on independent board elect wiring 2.5 sq mm complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in Existing concealed conduit including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, by suitable lugs and 3 mm thick laminated hylum sheet cover including taking old point wiring (any type without conduit) complete all as specified and directed [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No.12.00 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No 12.00 above, one 3 pin socket outlet 5 Amps on same board all as specified and directed.
All as per BOQ item No. 12.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination for 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F in repairs Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, one way, single pole, 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repair socket outlet 2 in 1, 3 pin 5 and 15 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repair switch socket combination 2in 1 , type 5/6 Amps flush type, 230 volt AC complete all as specified and directed. MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE
S&F in repairs switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repairs Buzzer electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND /HAVELLS as approved by GE]
S&F in repairs Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND /HAVELLS as approved by GE]
S&F in repair LED tube light fitting, surface mounted lumanaires, 1 x 18 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps,connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells Cat No : LHEXBLP7PN1W020 or equivalant in C&G/Bajaj/Surya
Dismantling and removing tube light rod from any fitting patty/box/decorative and replacement with LED tube rod 20/22 watt, 240V, PV > 0.90, colour Temp 6500 K, system luminious efficancy > 100Lm/W completecomplete all as specified and directed. Make : Havells C&G/Bajaj/Surya
S&F in repairs ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Supply and fixing modular switch socket combination 2-in-1, 5 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Supply and fixing modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Supply and fixing modular fan regulator, 5 step, high speed complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular metal flush box of 6 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
&F modular metal flush box of 4 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular metal flush box of 3 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular white cover plate of 6 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular white cover plate of 4 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F modular white cover plate of 3 module complete all as specified and directed. [MAKE:-ANCHOR / LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Taking down old unserviceable sub main wiring including service connections, of any size and any description including conduit pipe complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 2.5 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 2.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. [Make of Cable : Polycab/ Plaza/ Havells/KEI/V-MARC as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, TPN( Triple pole and neutral), 415 Volts, 200 amps rated busbar, 4 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
Supply and fixing factory made epoxy powder coated Distribution Board TP & N 4 ways ( VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCCB shall be measured and paid seperatly.
S&F sheet metal enclosure for SPN( single pole and neutral) DB single door type surface mounted concealed in wall 8 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE] NOTE:- MCB shall be measured and paid separately.
S&F MCCB 160 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 6 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE:(L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SP suitable for 240 volts, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in repairs MCB SPN suitable for 240 volts, AC supply 32 Amps, C Curve , with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S & F in repairs MCB SPN suitable for 240 volts, AC supply 40 to 63 Amps, C curve , with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S & F in repairs MCB TPN suitable for 415 volts, AC supply 40 to 100 Amps, C curve, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. [MAKE: (L&T)/ Siemens/ Legrand/HAVELLS as approved by GE]
S&F in replacement 3 pin plug top AC-230 V, 5 Amp, complete all as specified and directed. Make : Anchor/LEGRAND/HAVELLS
S&F in replacement 3 pin plug top AC-230 V, 15 Amp complete all as specified and directed. Make : Anchor/LEGRAND/HAVELLS
S&F in replacement sheet metal earth plug & socket, single pole and neutral with and including 1no. single pole MCB 20 Amps 240 volts complete all as specified and directed. [Make:-Legrand Cat No. 607841 or equivalent in L&T/C&S/Havells as approved by GE].
S&F in replacement PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC, 240 V complete all as specified and directed. Make Havells/ Palza/ Polycab/Anchor
S&F non metallic rigid PVC casing and caping ISI marked of 20mm size complete all as specified and directed.
S&F non metalic PVC conduit ISI marked of size 20mm dia complete all as specified and directed.
S&F LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified and directed. [Make :- Havells Cat no VENUSNEOHE2X2R36WLED840PIRSENSOR or Equivalent in crompton/syska
Supply and fix in repairs Coral post top lantern fitting 25 Watt (for Gate light) , energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories complete all as specified and directed. [Make: Havells , Cat NO: RUBYPT25WLED757PSYMTOPC or equivalent in Bajaj as approved by GE]
S&F building security light fitting 30 Watt made up of pressure die cast alluminium housing with high efficient LED as lighting source and pc over having top opening separate driver compartment with IP-66 Protection and impact resistance of IK07 including suitable galvanized iron pipe "light grade" brackets 1 mtr length bent to shape to obtain required shape including clamps ,nuts/bolts/washers etc connecting with suitable copper wire of size 23/0.0076 complete including all accesories ( bracket, clamps for fitting on wall) complete all as specified and directed. [Make: Bajaj Cat No: ENXTP30LWHCRPCSD or equivalent in Havells /C&G as approved by GE]
S&F in replacement flexible wire twin core copper conductor of size 23/0.0076 for ceiling fans, light fittings etc complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of size 25X 4 mm galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
S&F PVC insulated unsheathed, FRLS, copper cable 1.5 sq mm, AC, 230V, complete all as specified and directed
S&F PVC insulated unsheathed, FRLS, copper cable 2.5 sq mm, AC, 230V, complete all as specified and directed
Excavation in trenches, foundation in soft/disintegrated soil not exc. 1.5 metre wide and n. exc. 1.50m deep for HT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated material in soft/loose soil n. exc 50 M and depositing where directed at a level n. exc1.5M above the starting point, complete all as specified and directed.
M&L for sand cushioning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Punned layers shall be measured.
Supplying and laying reinforced precast concrete cable cover, class LV, flat of size 250mmx150mmx40mm all as specified and directed . Make: Mehtab tiles / Sukhi Enterprises
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall with the help of shadel of size 150 sqmm, 3.5 core, complete all as specified and directed . Make : Polycab / Havells India Ltd/ RPG cables Ltd as approved by GE.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor on wall with the help of shadel of size 95 sqmm, 3.5 core, complete all as specified and directed . Make : Polycab / Havells India Ltd/ RPG cables Ltd as approved by GE.
M&L for Providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping to poles & the like etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete for repair to existing pole/transformer foundation, complete all as specified and directed.
Supply, replacement & straining the ACSR conductor, including binding wire, tape and jumper complete all as specified and directed. Make: Bharat conductors/ Nicco/ Ujala/ VK conductors
S&F in replacement of MCCB 4 pole, 415 Volts, adjustable type,160 Amps, 50Hz 36KA, complete all as specified and directed. Make : Havells / Legrand / ABB / C & S/ GE power
S&F in replacement of MCCB 4 pole,415 Volts,adjustable type ,200 Amps, 50Hz 36KA, complete all as specified and directed. Make : Havells / Legrand / ABB / C & S/ GE power
S&F in replacement of MCCB 4 pole,415 Volts,adjustable type ,250 Amps, 50Hz 36KA, complete all as specified and directed. Make : Havells / Legrand / ABB / C & S/ GE power
S&F in replacement of MCCB 4 pole,415 Volts,adjustable type ,400 Amps, 50Hz 36KA, complete all as specified and directed. Make : Havells / Legrand / ABB / C & S/ GE power
S&F in replacement of MCCB 4 pole,415 Volts,adjustable type ,630 Amps, 50Hz 36KA, complete all as specified and directed. Make : Havells / Legrand / ABB / C & S/ GE power
Supply and jointing heat shrinkable outdoor type LT Straight through joint kits for XLPE/PVC insulated LT armoured cable 3.5 core complete with lugs of size 25 sqmm to 50 sqmm, complete all as specified and directed. Make: 3M, Raychem, Denson as approved by GE
Supply and jointing heat shrinkable outdoor type LT Straight through joint kits for XLPE/PVC insulated LT armoured cable 3.5 core complete with lugs of size 70 sqmm to 95 sqmm, complete all as specified and directed. Make: 3M, Raychem, Denson as approved by GE
Supply and jointing heat shrinkable outdoor type LT Straight through joint kits for XLPE/PVC insulated LT armoured cable 3.5 core complete with lugs of size 150 sqmm, complete all as specified and directed. Make: 3M, Raychem, Denson as approved by GE
Supplying & laying including taking down old GI Pipe in trenches, in road cutting and along pole 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying including taking down old GI Pipe in trenches, in road cutting and along pole 50 mm nominal bore, Medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earthing strip of dimension 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Deduct schedule of credit (calculation will be done off line) Rs. 62,236.00
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .