| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.0 L+₹2.5 L (8.06%)Rejected-Finance 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L2 | Rejected-Finance Not Lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not recommendation due to not enlished in a(i) category | |
| 4 | Rejected-Technical | - | Rejected-Technical Not recommendation due to not enlished in a(i) category |
Tender Value
₹42.3 L
EMD Value
₹84,640
Closing Date
14 Jul 2021, 6:00 pmClosed
CWE PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
81702 OUTSOURCING FOR MAINTAINENCE OF SWIMMING POOL AND PIPE LINE, VALVE INCL MISC WORK AT NDA KHADAKWASLA.
2021_MES_446707_2
81702 Outsourcing for Swimming Pool NDA
Open Tender
Civil Works
Item Rate
334 days
GE NDA Khadakwasla
As per tender
9 documents required · 9 mandatory
₹500
GE NDA Khadakwasla
₹84,640
Yes
17 Sept 2021
29 Jun 2021
16 Jul 2021
29 Jun 2021
14 Jul 2021
30 Jun 2021
Amount
Providing outsourcing services for manning and operation of Swimming Pool No-1, Swimming Pool No-2 & Swimming Pool No-3, at NDA Khadakwasla comprising of three Nos Pools, each pool have 02 to 03 motor and pumps for diffirent capacity etc for diffrent size, LT panels etc. Including daily routine cleaning of beds through suction sweeper properly as per direction of Engr-in-Charge, maintenance of all the electrical equipments like physical checking of metering system, tightening nut-bolts, routine fill the chemical as site requirement, greasing of pump motor contact points etc in order to ensure its healthiness and all time serviceability and trouble free operation of swimming pools beds and storage tank by deploying technically qualified and competent manpower, not less than one FGM, including Sundays/ Holidays in two shifts of 8 hours each pool all as specified and directed by Engr-in-Charge. The FGM shall fill up and maintain daily log sheets as per standard format made available at Raw Water. Shift Timings Swimming Pool No 1 Shift I : 0600 Hrs to 1400 Hrs (01 FGM) Shift II : 1400 Hrs to 2200 Hrs (01 FGM) Swimming Pool No 2 Shift I : 0600 Hrs to 1400 Hrs (01 FGM) Shift II : 1400 Hrs to 2200 Hrs (01 FGM) Swimming Pool No 3 Shift I : 0600 Hrs to 1400 Hrs (01 FGM) Shift II : 1400 Hrs to 2200 Hrs (01 FGM)
Note: (i) The FGM should be well Experienced and ITI (FGM) qualified and the contractor should submit the copy of their qualification and experience certificate. (ii) Contractor will employ standby /additional FGM for rest/ leave/ Holidays. (iii) Penalty Rs 1500/ shall be imposed on absent of operator per shift which will be recovered from the amount due to him through RAR/ Final Bill. (iv) The contractor is responsible for providing all the safety equipments including T&P to the FGM (v) Cleaning of workplace instrument/ machinery/ rest room shall be responsibility of contractor. (vi) Insurance of all operator / FGM shall be contractors responsibility. Deptt will not be responsible for any accident. (vii) Log Sheets of installation and attendance book shall be maintained and submitted weekly by the contractor. (vii) Technicians / tradesmen shall be in possession of requisite tools & safety gears like rubber hand gloves, rubber shoes etc and contractor shall cater adequate allowances on this account and quote the rates accordingly.
Providing outsourcing services for manning and operation of Valves at NDA Khadakwasla comprising Ten Valve at different location (Booster Pump House, Raw Water Pump House and NCOs Qtr) from time to time as per direction of Engr-in-Charge including daily routine clening of Valve properly as per direction of Engr-in-Charge, maintenance of all the water line and valve equipments like physical checking of metering system, tightening nut-bolts, greasing of Valve contact points etc in order to ensure healthness and all time serviceability and trouble free operation of all valve location by deploying technically qualified and competent manpower, not less than one Valve Man, including Sundays/ Holidays in two shifts of 8 hours each all as specified and directed by Engr-in-Charge. Shift Timings Booster Pump House Shift I : 0600 Hrs to 1400 Hrs (01 Valve Man) Shift II : 1400 Hrs to 2200 Hrs (01 Valve Man) Raw Water Pump House Shift I : 0600 Hrs to 1400 Hrs (01 Valve Man) Shift II : 1400 Hrs to 2200 Hrs (01 Valve Man)
Note : (i) The Valve Man shall be 10th pass and well experienced not less than 05 year in this field. (ii) Contractor will employ standby /additional Valve Man for rest/ leave/ Holidays. (iii) Penalty Rs 1500/ shall be imposed on absent of operator per shift which will be recovered from the amount due to him through RAR/ Final Bill. (iv) The contractor is responsible for providing all the safety equipments including T&P to the valveman. (v) Cleaning of workplace instrument/ machinery/ rest room shall be responsibility of contractor. (vi) Insurance of all operator shall be contractors responsibility. Deptt will not be responsible for any accident. (vii) attendance book shall be maintained and submitted weekly by the contractor. (vii) Technicians / tradesmen shall be in possession of requisite tools & safety gears like rubber hand gloves, rubber shoes etc and contractor shall cater adequate allowances on this account and quote the rates accordingly
M&L for brickwork with subclass 'B' Bricks straight or curved on plan exc 6m means redlius built in CM 1:6 complete all as specified and directed.
M&L for cement concerete 1:3:6, type C2 (using 40mm stone aggregate) as in foundation/resting platform in foundation filling and mass concrete
M&L for mild steel rolled section connected with each other with welding (angle, tee, channel, beam, hollow sections etc) as in main and cross beams, hip verticle hollow sections and jack rafters, purlins where connected to common rafters and running rils where verticle suctions and fixed in welded in wallsin wall surface with plates and other verticle sections are fixed in ground level embedded in concrete fixed and horizontal sections fixed in wall with bolt completly, fixed with angle, cleats or other connecting plates conforming to Gde Fe-410-W (Gde E-250) quality-B complete all as specified and directed by Engr-in-Charge.
All as per item No 5 above but plates (plain or chequered channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
M&L for pre painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall tixed with self tapping screws as specified and directed
M&L for new steel surfaces over 10cm width or girth and applying two coats of syntetic enamalled paint over and including red oxide primer complete all as specified and directed.
Supply and fix heavy duty, metal body. exhust fan 450mm sweep 1400RPM, single phase including all connecting accessories, complete all as specified and directed.
M&L for renewing of Glazed tiles in patches, area not exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new tiles of approved colour to match with the existing colour of tiles fitted at site complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in gray cement slurry with pigment in floors complete all as specified and directed.
M&L for sand/ stone dust filling under floors or in foundations, well ramming including watering and consolidation complete all as specified and directed.
M&L for 75mm thick cement concrete 1:2:4 type D-2, (using 40 MM graded stone aggregate) as in base concrete for chequered tiles.
M&L in repair/replacement for MS Pipes heavy duty as per IS 3589, Including specials, Supplied and laid complete, on column incl jointing by means of electric arc welding of nominal dia 250mm, thickness 5mm for connecting pumping delivery line incl necessary bends, Tees, short pieces, jointing flanges etc as per site requirement complete all as specified and directed by Engr-in-Charge
Taking down old and unserviceable Roational moulded polyethylene water storage tanks and S & F new Rotational moulded plyethylene water storage tanks double layer (cylindrical vertical with closed top) of capacity 5000 ltrs, hoisted and fixed in position and connecting to water incomming pipe line including all fittings such as top cover, all as specified and directed.
Supply & Fix in repairs Non reciving valve with ball arrangement and flanged type of size 450mm size heavy grade completet all specified & directed by Engr-in-Charge.
Supply & Fix in repairs Non reciving valve with ball arrangement and flanged type of size 150mm size heavy grade complete all specified & directed by Engr-in-Charge.
S&F taflon gland packing not less than 15mm dia as per existing size complete all as specified and directed by Engr-in-Charge
Dismantling and taking out from its position existing unservicable sluice valve of any size (80mm to 150mm) by unscrewing of nut & bolts rectified the defect like that up and down of gate, tightely operated of spindle etc complete and after reftified the defect re-installed at the same as per direction of Engr-in-Charge
M&L for precast cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) block massonry with sollid block exc 10cm thick in width and setting in cement mortar 1:6 complete in wall all as specified.
Cutting cast iron/ Ductile iron pipes in position and reducing to required length for insertion of new tees, branches, Machanical Joints etc, all as directed. Size of pipe 300/450/400mm bore.
Supply and fix mechanical flanged joint including follower gland, gaskets, nuts and bolts for MJ ends of size 450/300mm for repairs to CI/ DI pipeline damaged during breakdown all as sepcified and directed by Engr-in-Charge
Deccan Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .