Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹38.8 L+₹2.8 L (7.81%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹39.0 L+₹2.9 L (8.14%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | L4₹43.1 L+₹7.1 L (19.7%)Accepted-Finance F 67 SHIV NAGAR BEHIND A G OFFICE JAMMU JAMMU JAMMU KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | L4 | Accepted-Finance L4 |
Tender Value
₹39.2 L
EMD Value
₹80,000
Closing Date
4 Dec 2023, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Supply, Installation, Testing Commissioning of HVAC System and allied works for construction of Auditorium and Cafeteria including parking, store lifts and Ramps etc. at Govt. Chest Diseases Hospital, Jammu
2023_PWDJK_237700_1
MHDJ/e-NIT 180 of 2023-24
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
60 days
CD HOSPITAL JAMMU
AS PER E NIT
2 documents required · 2 mandatory
₹1,000
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹80,000
20 Dec 2023
21 Nov 2023
5 Dec 2023
21 Nov 2023
4 Dec 2023
27 Nov 2023
21 Nov 2023 - 4 Dec 2023
Amount
Supply Installation, Testing & Commissioning of Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll/Twin Rotary Compressor(s), microprocessor based Controller, Minimum 2 Compressors above 14HP Module, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .
Supply, installation testinga nd commissioning of following minimum capacity 4-wayflow VRV/VRF CassetteType Indoor ceiling mounted unit equipped with synthetic washable media pre-filter,fan section with low noise fan/dynamically balanced blower,multi speed motor,coil section with DXCoppercoil,electronic expansion valve, outer cabinet,drain pump,grill, necessary supports, vibration isolation,cordless remote control etc., suitable for operation on single phase 230V±10%,50Hz AC supply,complete,as required.The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree CDB and 19 Degree CWB temperature. 3.2 TR
Supply, Installation,Testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system,complete with fittings, with suitable adjustable ring type hanger supports,jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. as required : 9.5 mm dia (OD) (Soft drawn) with tube thickness 0.8 mm with 13 mm thick insulation
Supply, Installation,Testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system,complete with fittings, with suitable adjustable ring type hanger supports,jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. as required : 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.0 mm with 19 mm thick insulation
Supply, Installation,Testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system,complete with fittings, with suitable adjustable ring type hanger supports,jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. as required : 19 mm dia (OD) (Hard drawn) with tube thickness 1.0 mm with 19 mm thick insulation
Supply, Installation,Testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system,complete with fittings, with suitable adjustable ring type hanger supports,jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. as required : 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.0 mm with 19 mm thick insulation
Supply, Installation,Testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system,complete with fittings, with suitable adjustable ring type hanger supports,jointing/brazing including accessories,insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. as required : 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.1 mm with 19 mm thick insulation
Supply, installation, testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated. 32 mm dia
Supply, installation, testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated. 25 mm dia
Proviing and laying of control cum transmission wiring of 2 core x 1.5 sqmm copper cable in PVC conduits between indoor and outdoor units.
Supplying,Installation,Testing and Commissioning of Cubical Type HVAC PANEL Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars,Interlocking ,Synchronising etc. as required as per the Following Description.(IP:55).Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet.Gland Plates to be 3.0 mm Thick.(For Details Refer SLD)
INCOMER MCCB 125 A F.P 36 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%
Electronic Timer
Power Contactor 140 A 415 Volts 4P AC-3 Duty
Single Phase Preventor
OUTGOINGS F.P M.C.B 63 A 10 KA
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying ,Laying and Testing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/Cable Tray as required. 3.5C x 50 mm² LT XLPE (A2XFY)
Supplying ,Laying and Testing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/Cable Tray as required. 3.5 C X 300 Sq.mm Aluminium Armoured
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) 3½ X 50 sq. mm (35mm)
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) 3.5 C X 300 Sq.mm Aluminium Armoured
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Design, Supply, installation, testing and commissioning of a 200KVA Servo Controlled Automatic Voltage Stabilizer, 3 phase, oil cooled . AS PER SCOPE OF WORK SERIAL NO 17
SKYLINE AIR CONDITIONING ENGINEERS PVT LTD
RM Controls & Automations
M/S GLOBUS POWER SYSTEMS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .