| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 CrAdmitted-Finance | ₹30.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹32.8 CrAdmitted-Finance 44 TARUN NAGAR GUWAHHATI P O CHRISTIAN BASTI PS BHANGAGARH KAMRUP METRO PIN 781005 | KAMRUP METRO | ASSAM | 781005 | ₹32.8 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VERSHA TECHNOTRADE PVT LTD L2 | hitech construction L1 |
|---|---|---|---|---|---|
| 1.00 | CIVIL WORKS (A)
EARTH WORK IN EXCAVATION
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
Up to a depth of 2.00m below the existing ground level.
(a) In ordinary soil | 1,779.36 | Cum | 146 ₹2.6 L | 120 ₹2.1 L |
| 2.00 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.
(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | 1,131 | Cum | 462 ₹5.2 L | 400 ₹4.5 L |
| 3.00 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete.
In prop 1cement: 3 sand :6 coarse aggregate by volume | 49.5 | Cum | 5,742 ₹2.8 L | 5,150 ₹2.5 L |
| 4.00 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete.
In prop 1cement: 4 sand :8 coarse aggregate by volume | 6 | Cum | 5,204 ₹31,224 | 4,700 ₹28,200 |
| 5.00 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
c) 100mm thick | 1,256 | SqM | 658 ₹8.3 L | 530 ₹6.7 L |
| 6.00 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | 86 | SqM | 243 ₹20,898 | 200 ₹17,200 |
| 7.00 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(I) Using Mixer Machine
(A) In substructure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
N) Without using admixture, plasticiser
a) M15 grade concrete or Prop. 1:2:4 | 1.2 | Cum | 7,352 ₹8,822.40 | 6,470 ₹7,764 |
| 8.00 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(I) Using Mixer Machine
(A) In substructure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
N) Without using admixture, plasticiser
b) M20 grade concrete or Prop. 1:1.5:3 | 52 | Cum | 8,110 ₹4.2 L | 7,600 ₹4.0 L |
| 9.00 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(I) Using Mixer Machine
(A) In substructure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
N) Without using admixture, plasticiser
c) M25 grade concrete | 720 | Cum | 8,832 ₹63.6 L | 8,200 ₹59.0 L |
| 10.00 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(I) Using Mixer Machine
(B) In super structure from plinth level up to 1st floor level.
Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc.
N) Without using admixture, plasticiser
c) M25 grade concrete | 94 | Cum | 9,076 ₹8.5 L | 8,400 ₹7.9 L |
Tender Value
₹26.2 Cr
EMD Value
₹52.4 L
Closing Date
5 Feb 2021, 2:00 pmClosed
C.E. PWD (Roads), Assam, Chandmari, Guwahati, 7810
O/o the C.E. PWD (Roads), Assam, Chandmari, Guwahati, 781003
SOPD_G_20_21_15 Construction of Auditorium Building at Amingaon under SOPD(G) for the year 2020-21.
2021_PWD_20353_1
CE/DEV/TB/93/2020-21/45
Open Tender
Civil Works
730 days
Jalukbari
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,000
Empowered Officer, Assam State Road Board
₹52.4 L
Yes
O/o the C.E. PWD (Roads), Assam, Chandmari, Guwaha
13 Feb 2021
22 Jan 2021
5 Feb 2021
22 Jan 2021
5 Feb 2021
28 Jan 2021
22 Jan 2021 - 5 Feb 2021
27 Jan 2021
Amount
CIVIL WORKS (A) EARTH WORK IN EXCAVATION Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete. In prop 1cement: 3 sand :6 coarse aggregate by volume
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete. In prop 1cement: 4 sand :8 coarse aggregate by volume
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser a) M15 grade concrete or Prop. 1:2:4
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser c) M25 grade concrete
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In super structure from plinth level up to 1st floor level. Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. N) Without using admixture, plasticiser c) M25 grade concrete
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In super structure from plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser c) M25 grade concrete
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
TIMBER SHUTTERING (FORMWORK) Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut Circular or curved in plan (Using 38mm thick plank)
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.1 & 3.1.3(b).
PLYBOARD SHUTTERING (FORMWORK) Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.2.1 & 3.2.3(b).
MASONARY WORK Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.
Extra cost for lifting of brickbats and sand for filling of sunk floor for each subsequent floors above the ground floor as directed and specified.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure upto plinth level including dewatering if necessary (d) In proportion 1:6.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Superstructure above plinth level up to 1st floor level. (b) In proportion 1:4.(1 cement:4 sand)
Extra over item no. 4.1.4 above for brick work in each subsequent floor or part thereof above 1st floor level.
1st class brick wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level. (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall
CEMENT CONCRETE FLOORING 40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
CERAMIC TILES ON WALLS Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). c) Deluxe range (Somany/Orient/Nitco/Vermora Make) iv) Of size 300mm x 900mm and above
VITRIFIED TILES A) ON FLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). c) Deluxe Range (Somany / Orient /Nitco / Varmora / Jhonson Make i) Of size 1000mm x 1000mm
CONCRETE TILES (A) FLOOR TILES Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (b) MULTIWYN TILES Legato, Ribbera, Matrix, Esquire, Enigma, Flora, Little Flora, Nirvana, Purl, Contoura, Cobble, Canaletta, Nexus, Koral
GRANITE FLOORING Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey /Sika /Pedelite /Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (i) Normal Quality (ii) With White cement
ANTISKID TILES Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC ii) Executive range-2 (Sizes 600 mm x 600mm and above) (a) Somany made- VC Shield (Group- 25) (605 x 605) mm Deluxe -VC
CEMENT PLASTERING 10mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises , internal rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
15mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises , internal rounded angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
15mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises , internal rounded angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
Neat Cement Punning
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. a) On Single coat plaster
Extra over item no. 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. a) On Single coat plaster
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed. a) On Single coat plaster
15 mm thick plain cement mortar bands in cement mortar 1:4 in width including curing complete as directed. A) Up to 300 mm width c) Raised band
POINTING Pointing on brick work with cement mortar including curing complete as directed. (Measurement shall be taken on surface area of the wall). B) Cement mortar prop. 1:4 b) Ruled pointing
CELLING LINING AND PARTITION Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) pre-coated G.I. angle size 24mmx24mmx80mm thick fixed to the brick wall/ partition at the perimeter of ceiling with nylon sleeves and screws, at 610mm c/c. Then suspending main 'T' section (bottom pre-coated) size 24mmx38mmx0.70mm and 3600mm long from the soffit in one direction with the help of metal Rawl Plug. Soffit cleat and G.I. Rod 4mm diameter with galvanised level clip 1220mm c/c G.I. cross. BPB Grid ceiling system with Fabric Based Sound absorb Panel (595mmx595mm).
ROOFING & ROOF TREATMENT Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) Dyna roof / Wonder Roof /JSW Steel / Spectrum or equivalent as directed by the Departement. (iii) 0.50 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. Dyna roof / Wonder Roof /JSW Steel / Spectrum or equivalent as directed by the Departement. (iii) 0.50 mm thick
WOOD WORKS Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately). B) With 1st class local wood (Gamari /Hollock /Bonsum ) (ii) 35 mm thick.
Providing, fitting and fixing fully glazed wooden door shutters with necessary butt hinges, screws etc. complete as per approved drawing as directed and specified at all levels.(fittings e.g. tower bolt, door handle, aldrop, glass panes etc. should be measured and paid seperately). (a) With Teak or Sissu Wood (II)35mm thick
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core. (ii) 35 mm thick .
GRILL WORKS Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I . Plain grill (c) Fixed to Brickwork/P.C.C/R.C.C.
PVC, uPVC, FRP DOORS & DOOR FRAMES uPVC Doors & Windows Fixed Windows Supplying and installing uPVC- Fixed Windows made out of Lead free, UV resistant green profile of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with galvanized steel 1.5/2mm including glazing bead , grooving bead, drain cap, fisher screws, packing pieces, necessary stainless steel screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of Silicon sealant from inside / outside of dowcorning / GE or equivalent. With 5mm clear glass. (a) Fixed window using uPVC sections of size 58mm x 52mm x 2.4mm thick wall for frame and 58mm x 68mm having 2.4mm thick wall for glass sash having reinforcement of 1.5mm thick in both frame & sash. (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
Supplying and installing uPVC- Sliding Windows made out of Lead free UV resistant green profile of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass. (b) 2 Track Sliding Window without Flyscreen using uPVC section of size 58mm x 53mm x 2.4mm thick wall for frame, 37mm x 61mm x 2.4mm thick wall for glass sash having 1.5mm thick reinforecement for both frame & sash, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT) (i) 2-Panel with 5mm clear float glass
Supplying and installing uPVC- Sliding Windows made out of Lead free UV resistant green profile of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass. (b) 2 Track Sliding Window without Flyscreen using uPVC section of size 58mm x 53mm x 2.4mm thick wall for frame, 37mm x 61mm x 2.4mm thick wall for glass sash having 1.5mm thick reinforecement for both frame & sash, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT) (ii) 4-Panel with 5mm clear float glass
Casement Windows Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel atleast 1.5/2mm thick including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ ENCRAFT / WINSTA KOMMERLING). a) Single leaf Side hung Window using uPVC section of size 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash. With 5mm clear float glass (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel atleast 1.5/2mm thick including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ ENCRAFT / WINSTA KOMMERLING). (d) Single leaf Top hung Window using uPVC section of size 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash With 5mm clear float glass (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
Supplying and installing uPVC- sliding door made out of Lead free UV resistant green profile of BIS standard uPVC multichambered sections of wall thickness 2.8mm with corners fusion welded, fully reinforced with Galvanized steel 2mm including interlock profile, glazing bead, grooving bead, brush seal, locking arrangement, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. (I) 2 Track Sliding door with Flyscreen using uPVC section of size 88mm x 50mm x 2.8mm thick wall for frame, 37mm x 75mm x 2.8mm thick wall for glass sash, 25mm x 49mm x 2.8mm thick wall for flyscreen sash, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT) (a) 2-Panel i) Using 5mm clear float glass
Supplying and installing uPVC- Casement Door made out of Lead free UV resistant green profile of BIS standard uPVC sections of wall thickness 2.4mm, multichambered with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, locking arrangement, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (b) Double leaf Side hung Door with a Dummy Mullion - French Door using uPVC section of size 58mm x 69mm x 2.4mm thick wall for frame, 58mm x 109mm x 2.4mm thick wall for glass sash, 58mm x 61mm x 2.4mm thick wall for dummy mulion, Aluminium threshold at bottom. (WINSTA KOMMERLING/ FINESTA/ ENCRAFT) i) Using 5mm clear glass
PAINTING WALL PAINTING Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a). Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing old/ new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish of Sandex Matt brand of Snowcem India Ltd. of required shade after clering and clearing the surfaces etc.including scaffolding complete as directed at all levels (two coats)
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i). Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PAINTING ON STEEL AND OTHER METAL SURFACE Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
DOOR AND WINDOW FITTING BRASS FITTINGS Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). a) Sliding door bolts ii) 300mm X 16mm
Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). b) Tower bolts iii) 300mm X 12mm
Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). c) Door handles : iii) 150mm
Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). n) Mortice Lock vertical type : ii) 75mm
Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). t) Door stopper with rubber stopper
Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. A) Godrej b) Double Speed Door Closer( size 140mm x 39mm x 60mm)- Model Number C 752
GLASS FITTINGS Providing and fixing clear sheet glass beded in putty and fixed with/without wooden bidding including necessary cutting and glass to be required sized(payment for wooden bead shall be made separately). (2). Area of glass panes exceeding 0.15m2 but not exceeding 0.52m2. (c). 5.00mm thick.
STEEL AND IRON WORKS REINFORCEMENT Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level). a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level). b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works, retaining wall & boundary wall etc.)
Extra over item 18.1.1 for each subsequent floor or part thereof above first floor level.
Structural steel work in sigle sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. a) In beams and joists fitted independently without connecting plates.
ROOF TRUSS Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube
DOOR FRAMES Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). (a) 1.25mm thick sheet (iii) Size 125mm x 60mm (Single rebate)
STEEL RAILING Providing and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge. (For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered).
MANHOLE COVER Supplying and fixing C.I. cover without frame for manholes: 455x610mm rectangular C.I. cover (light duty), the weight of the cover to be not less than 23k.g.
FIRE RESISTANT DOORS Cost of steel fire check door of 120 minutes fire rating confirming to BS 476 with steel frame and 46 mm thick steel shutter including all necessary fixtures etc.
C.C. BALUSTER RAILING Providing fitting and fixing C.C. Baluster of required size and design with cement concrete coping and base including all fitting and fixtures as directed by the engineer in charge. ( For payment total length of the railing to be considered).
PLINTH PROTECTION WORKS Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in prop. 1:5 with half brick thick side walls and 100 mm thick CC(1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trances and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
PILING WORKS MACHINE DRIVEN PILES Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1) C) UNIFORM PILE (II) Concrete Grade M25 v) Pile dia 500 mm
Extra for using admixture & plasticiser (b) RCC grade M25 vi) Pile Dia 500 mm
Empty boring for specified diameter piles from ground level to cut-off level. f) Pile Dia 500 mm
REINFORCEMENT Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) (A) TMT bar made of Primary producer (From Primary producer)
PILE TESTS Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
WATERPROOFING SURFACE PREPARATION Preparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.
Applying 2 coats of 1mm thick acrylic polymer modified cementitious waterproofing coating Brushbond of Fosroc Chemicals/Dr. Sealkit Flexbond AP 121 C (Asian Chemicals)/ MASTERSEAL 550 of BASF for waterproofing structures like roof slabs, basement, sunken slabs, chajjas, tunnels, water tank etc. after proper surface preparation and soaking the surface with water prior to application complete as specified and directed by the Department at all levels.
ANTI-TERMITE TREATMENT Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution.
SANITARY & WATER SUPPLY WORKS (B) SANITARY FIXTURES EUROPEAN TYPE WATER CLOSET (WC) Providing fitting and fixing Vitreous china wall hung water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make/(vi) Geneve walvit Pan set (inclusive of seat cover and fittings) (white/coloured) (Cat. No. C8498)
CONCEALED CISTERN Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (C) Jaquar Make Concealed Cistern (Cat.No.CIB-WHT-31801011X) with Control Plate (CP) (Cat. No. CIS-CHR-31191510X)
URINAL Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (C) Jaquar Make (a) White (ii) Compact (Cat. No. URS - WHT - 0701)
AUTOMATIC FLUSHING CISTERN Supplying, fiting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (ii) Hindware make (a) White Auto Cister 10 Litre (Cat. No. C 61002)
DIVISION PLATE (FOR URINAL) Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. (ii) Hindware Make (a) White (ii) New Division Plate (Cat. No. 61005)
WASH BASIN Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) UNDER COUNTER BASIN (A) Parryware Make/ (i) Chester 550 x 445 (Cat. No.C8469) (White or Coloured)
KITCHEN SINK (STAINLESS STEEL) Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (B) Nirali (vi) Grace Deluxe Medium (Bowl Size - 445 x 368 x 190) Glossy
FITTINGS & ACCESSORIES MIRROR Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware make a) Size 800 mm x 600 mm
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware make b) Size 600 mm x 450 mm
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat. No. CAN-1331N)
Providing, fitting and fixing Liquid Soap dispenser and Liquid Soap container complete as directed and specified. (i) Jaquar Make (a) Continental (Cat. No. ACN-1135N) with Glass Bottle
TOWEL RAIL,TOWEL RACK & TOWEL RING Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (iv) Queen's (450mm long) (Cat.No.AQN-7711A)
ROBE HOOK Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. (a) Jaquar make (iii) Kubix (Cat. No. AKB - 35791)
TOILET PAPER HOLDER Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified. (a) Jaquar make (i) Continental toilet paper holder (Cat.No. ACN-1151N)
WASTE COUPLING Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar make (i) 32 mm (HT / FT) (Cat. No. ALD - 705 / 709)
BOTTLE TRAP Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (ii) Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
BIB COCK Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Essco make (Delux/Sumthing spl./Tropical) (a) Bib cock short body
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Essco make (Delux/Sumthing spl./Tropical) (b) Long body bib cock with wall flange
STOP COCK Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately). Jaquar/(a) Continental / Clarion/(ii)15mm dia( Angular stop cock )
PILLAR COCK Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaguar make (b)Long neck with aerator
SINK COCK Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) Sona brand a) Sink cock upper/ lower spout 15mm
HEALTH FAUCET Providing and fixing health faucet with 1.0 m PVC tube and swivel hook including all fittings complete.
GRAB BAR Fixing grab bar fabricated from 32 mm dia seamless stainless steel tube in washroom facilities for physically handicapped, with non-slip gripping surface complete including cutting and making good the walls and floors where required.
SHOWER Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) Jaquar make b) Queen's collection (i) Overhead rose shower with revolving joint & 150 mm long swivel shower arm
BASIN MIXTURE Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed. Crabtree Frattini make (For VIP use.) a) Florence i)Central hole basin mixer without pop-up Cat No.21051 for wash basin
DIVERTOR Supplying, fitting and fixing Chrome Plated (C.P.) divertor of approved brand complete as directed. Jaquar make b) Queen's Collection - 4-way divertor for concealed fitting with built in non return valves (For VIP use only. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) Cat No.7421
PVC PIPES,BENDS,JUNCTIONS,TEES ETC. Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 75mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (vi) 50mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (v) 50mm dia
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 75 mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (v) 50mm dia
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 110 mm x 75mm
Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iii) 110 mm x 75mm
COWEL Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110mm dia. PVC cowel of ISI make
GRATING Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. (a) 110mm dia
C.P. Grating (ii) 110mm dia
MANHOLE COVER Providing fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
SOAK PIT AND INSPECTION CHAMBER Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
PIPING Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (A) Exposed or in trenches b) 20 mm nominal outer dia pipe
PIPING Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (A) Exposed or in trenches c) 25 mm nominal outer dia pipe
PIPING Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (A) Exposed or in trenches d) 32 mm nominal outer dia pipe
PIPING Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (A) Exposed or in trenches e) 40 mm nominal outer dia pipe
PIPING Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (A) Exposed or in trenches f) 50 mm nominal outer dia pipe
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (B) Concealed pipe with cutting chases & making good the walls a) 15 mm nominal outer dia pipe
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (B) Concealed pipe with cutting chases & making good the walls b) 20 mm nominal outer dia pipe
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (B) Concealed pipe with cutting chases & making good the walls c) 25 mm nominal outer dia pipe
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (B) Concealed pipe with cutting chases & making good the walls d) 32 mm nominal outer dia pipe
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (B) Concealed pipe with cutting chases & making good the walls e) 40 mm nominal outer dia pipe
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermel stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00m spacing.This includes joint of pipe. (B) Concealed pipe with cutting chases & making good the walls f) 50 mm nominal outer dia pipe
VALVE Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. a) 50 mm dia.
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 40 mm dia.
Supplying and fitting ball valve as specified and directed.. a) 25 mm dia. (gun metal)
WATER TANK Supplying and placing plastic Cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. 2000 Lt capacity (a) Sintex make
ELECTRICAL WORKS (C) SUB HEAD 1 : POINT WIRING , TV, TELEPHONE AND DATA Wiring for light/ fan/ call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including ceiling rose etc. complete Short point up to 3.00 metre Length.
Medium point up to 6.00 metre Length.
Long point up to 10.00 metre Length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) cable in surface/ recessed PVC 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 3 x 1.5 sq. mm. cable in 20 mm dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) with earth continuity in surface/ recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit wiring system. (a) with 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit.
b) with 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. in 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit
c) with 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. in 25 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit
With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. b) with 4 x 4 sq. mm. + earth continuity with 2x2.5 sq. mm. cable in 25 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit
c) with 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit
With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit.
With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit.
Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. 120 watt electronic modular step speed control 2 - module type
Supplying with fitting fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp two way modular clip in switch , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 1-2 module type Metal
3 module type Metal
4 module type Metal
6 module type Metal
8 module type Metal
9 module type Metal
12 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 1 module
2 module
3 module
4 module
6 module
8 module
9 module
12 module
Supplying including fitting and fixing of TV SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing of RJ-11 Telephone jack , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing of CAT 6 RJ-45 Computer jack in one module , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing of 25A Modular Motor Starter 2M , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying ,installation, testing & commissioning of 2 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.
Supplying installation testing of UTP CAT6 Cable without PVC conduit
Wiring for Co - axial Jelly Flooded (Unarmoured) (FINOLEX /RR KABEL /NICCO / ANCHOR make) cable in existing surface conduit wiring system including connection etc as required. Co - axial Jelly Flooded (Unarmoured) RG 6 (Copper)
Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:
Supply and fixing 32 mm mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:
Supply and fixing 25 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required:
Supply and fixing 32 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required:
Supplying ,installation, testing & commissioning of Distribution Box 20 pairs with Krones ( SIEMENS or equivalent as approved by the Deptt.)
Supplying ,installation, testing & commissioning of Distribution Box 50 pairs with Krones ( SIEMENS or equivalent as approved by the Deptt.)
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet near the AC unit including connections, painting etc. as required.LEGRAND (ARTEOR or other equivelent approved by engineer)
SUB HEAD 2 : DISTRIBUTION BOARD Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager make) 8 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof reversible Double door IP-43 double door surface mounting horizontal TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) double door
6 way TPN (4+18) double door
8 way TPN (4+24) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 25A
Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 20A Capacity. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.) make)
Supplying fitting and fixing industrial Plug & Socket in surface mounting TPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of 4P MCB complete with making necessary connection etc. as specified and directed by the Deptt. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 20 A Capacity.
30/32A Capacity.
Supplying and fixing weather proof IP56 box (Hensel make) including supplying and fixing of 1 no. 25A TPN MCB.
Supplying and fixing weather proof IP56 box (Hensel make) including supplying and fixing of 1 no. 40A TPN MCB. (for electrical vehicle charging sockets)
Supplying and fixing weather proof IP56 box (Hensel make) including supplying and fixing of 1 no. 63A TPN MCB. (for electrical vehicle charging sockets)
Supplying and fixing weather proof IP56 box (Hensel make) including supplying and fixing of 1 no. 25A DP MCB
HT CABLE Supplying and laying under ground heavy duty 11KV (E) grade 3c 185 sqmm XLPE insulated & PVC sheathed aluminium conductor as per IS: 8130 Class-2 armoured cable, inner/ outer sheath- Extruded FRLS type PVC ST-2 as per IS:5831 including providing & fixing of necessary cable clamp on wall and laying in existing Hume pipe/ built trenches/ risers/ cable racks etc.
Supplying, terminating, testing and commissioning of outdoor type heat shrinkable terminations for 11kV(E) grade 3c 185 sqmm XLPE insulated & PVC sheathed armoured aluminium conductor cable.
SUB HEAD 4 : DIESEL GENERATOR SET Design, manufacturing, assembly, supply at site, erection, installation, testing and commissioning of following rating Diesel Generating sets with all required accessories to meet the specifications, indicative drawings and the requirements as given below and complete in all respects as per Specifications including preparation of all detailed arrangement drawings, all necessary co-ordination for civil works like Genset foundation and padestral, supply and commissioning of all related and required equipments and accessories to commission each of the following sets: Radiator cooled DG set outdoor type, PT fuel pump with STC injectors, fuel cooler and spin-on type fuel filters. , Oil pump, strainer, filters and all required piping, Exhaust manifold with stainless steel flexible connection to "Critical" grade silencer suitable for vertical / horizontal mounting Electronic/ digital Governer with Genset Controller, DC starter with battery charging alternator and built-in regulator, All required batteries as specified with all connecting leads and terminations, All specified and required safety systems including LLOP, HWT, Overspeed and Low Coolant, Power Control Panel with governor module, AVR module, PTCT module, Suitably rated set of CTs and all mounting hardware, Seperately excited brushless Alternator with Class H insulation should be designed for parallel operation with damper winding and should be suitable to deliver 110% for 1 hour in any 12 hours of operation NOTES : Cable termination is envisaged for connecting 380kVA DG Sets to the Main LT Panel. Required terminals control wiring for AMF, synchronising or load sharing operations, CTs as specified are required to be provided in the adaptor box of DG Set. Rates shall include all these accessories as per agreement. DG Sets shall be with PC3.3 power command controller with auto start, auto load management, auto active and reactive load sharing, auto/ manual synchronising by means of automated process with PLC as well as by manual operation. DG Set supplier shall provide microprocessor based controller mounted on the engine with all electrical/ mechanical parameters monitering facility including major electrical & mechanical protections should be inbuilt in the genset controller and fault indication with provision for its remote indications & control. Genset controller should be compatible for remote operations. 380kVA DG Sets comprising of turbo charger, after cooler diesel fired radiator cooled (Natural air cooled type) engine designed to deliver minimum 487BHP (nominal) at 1500 rpm coupled with 415V 50Hz alternator designed to deliver 500kVA at 0.8 power factor with microprocessor based PC 3.3 power controller with kW, Power factor, Frequency,Current, Voltage - Remote HMI AMF control panel, Battery charger, Remote/Auto start panel, Auto/ Manual synchronizing panel, Audio/Visual annunciationfor faults, Auxiliary output relays, fuel tank's level sensor with controller and remote annunciators- providing voltage regulation, engine protection, alternator protection, operator interface and isochronous governing and both mounted on common base frame with anti-vibration pads.
SUB HEAD 5 : FLOOR BOARDS Designing, fabricating, Wiring, Testing and delivering to site the following sheet steel cubicle type fully compartmentalized panels fabricated from 1.6mm thick CRCA sheet, dust and vermin proof, indoor type TPN Panels with hinged lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3 phase 4 wire 50Hz AC supply and cable alley should be suitable for cable entry from top or bottom and with segregated bus-bar chamber with bus bars as specified below and including supplying and fixing following switchgears, meters and accessories, inter-connections, bonding to earth, powder coated painting and marking as specified. Switch boards complete as per schematic diagram: Type of construction: Form 3 Indoor IP classification: 42 Colour: Siemens Gray Powder Coated, as per approved sample. The BOQ shall be read in conjuction with general notes, specification and single line diagram (attached for ref.) In case of any disrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/ Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered. All MCCB shall be with door interlocked rotary handle with ON/TRIP/OFF position indicator, continuous variable thermal magnetic O/C and S/C releases. MCCB 250A & above rating shall be provided with microprocessor based releases (settable at site) and shall be provided with O/C, S/C and E/F release. All microprocessor based MCCB having E/F releases should have neutral CT's. All feeder doors shall have pad locking arrangement. All TP Feeders shall have solid isolatable neutral link. All MCCB used in starter feeder shall be suitable for motor duty applications. (curve 'X' type) All switchgear used in starter feeder shall be type-2 coordinated. Manufacture is required to submit manufacture' type-2 coordinated chart for the make used. Removable lifting hook shall be provided in all transportation sections. All bus bar shall be insulated with coloured PVC sleeve i.e. Red, Yellow, Blue and Black as per colour code. Internal wiring of panel shall be with size 2.5sqmm flexible copper conductor for Cast Resin Type CT circuit and control wiring with 1.5sqmm. All indicating light shall be LED type. The contractor shall prepare proper GA drawings and shall seek approval for these from the project manager / electrical consultant prior to construction of all panels and boards. All live accessible parts shall be shrouded with 3mm thick polycarbonate /FRP sheet and all equipment shall be finger touch proof . MAIN LT PANEL INCOMER (For Transformer) 1no 1250A, 50kA FP electrically operated draw-out type ACB with reverse power relay and microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type indication, with three phase indicating lamps, 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current, Frequency, Power, Energy, Power factor with RS 485 port and set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB. 1250/5A CT's for capacitor panel INCOMER (For DG Set-1) 1no 630A, 36kA FP Motorized MCCB with reverse power relay and microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type indication, with three phase indicating lamps, 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current, Frequency, Power, Energy, Power factor with RS 485 port and set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB. Busbar: Equally sized three phase & neutral Aluminium conductors busbar suitably sized to carry 1600A current having a maximum current density of 0.1 amp per sq.mm and suitably insulated with colour coded heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 40A HRC fuse with Class "I" cordinated encapsulated spark gap surge arrestors, less than 1.3 kV, 50kA, 10/350 micro second, as per specification. Outgoings: 1no. 630A,36kA TP with isolatable neutral link MCCB with rotary operating handle with door interlock, with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type indication with and ON/ TRIP/OFF indication. 2nos. 400A,36kA TP with isolatable neutral link MCCB with rotary operating handle with door interlock, with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type indication with and ON/ TRIP/OFF indication. 2no. 250A,36kA TP with isolatable neutral link MCCB with rotary operating handle with door interlock, with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type indication with and ON/ TRIP/OFF indication. 1no. 200A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1nos. 160A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 3nos. 125A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no. 100A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. Bus coupler 1no 630A, 36kA FP Motorized MCCB (Ics=Icu upto 415V) with microprocessor-based relay for O/L, S/C protection with time delay facility and fault type indication, with ON/OFF indication and suitable number of auxiliary contacts for electrical interlocking as described above. INCOMER (For DG Set-2) : 1no 630A, 36kA FP Motorized MCCB with reverse power relay and microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type indication, with three phase indicating lamps, 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current, Frequency, Power, Energy, Power factor with RS 485 port and set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB. Busbar: Equally sized three phase & neutral Aluminium conductors busbar suitably sized to carry 1000A current having a maximum current density of 0.1 amp per sq.mm and suitably insulated with colour coded heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 40A HRC fuse with Class "I" cordinated encapsulated spark gap surge arrestors, less than 1.3 kV, 50kA, 10/350 micro second, as per specification. Outgoings: 4nos. 160A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 3nos. 125A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 3nos. 100A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. ELECTRICAL INTERLOCKING: Electrical interlocking between 2nos.DG sets incomers, 1no., Transformer incomer and one nos. bus couplers as shown in interlocking chart given on SLD drawing. In Built PLC Control Panel SCADA System Auto start/ Auto stop Automatic Synchronisation System. Automatic active and reactive load sharing among D.G. Sets. Auto load sharing and management. Controller and Local fuel tank's level sensor operation & monitoring 2nos. 24V Battery Charger for 380kVA DG sets Potential free contacts for Engine interfacing as per PCC-3.3 engine control circuit drawing provided by respective vendor and for AMF Panel. 2nos.16A TPN RCBO 30mA (For 415V AC Load bus sensing to PCC) Potential free contacts for feedback of synchronizing breaker to PCC and PCC will provide breaker closing/ tripping command to LT Panel. NOTES: PLC Control Panel should be suitable to control the 2nos. 380kVA DG sets. All required devices for inputs to and outputs from the PLC whether digital or analog required to operate the DG Sets and accessories as specified should be included in design and costing. BOQ given above does not limit the bidder from including all such components as are necessary for proper and safe Fuel operation system, AMF, synchronising and load sharing in both manual as well as Auto & PLC mode. Each DG supply breaker shall be provided with 1nos 12 window audio/ visual annunciator system complete with hooter, Acknowledge, Test and Reset PBs and for Annunciation of engine over speed, Electrical Protection trip, Engine fail to start, low fuel level faults etc. 1No. 40x10 mm Aluminium Earth Bus strip across the width of the Panel . Main LT Panel complete as above
Ground Floor MDB ( Light and Power) INCOMER : 1no. 160A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 200A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 3nos. 63A TPN MCB (10kA) (C Curve) 7nos. 40A TPN MCB (10kA) (C Curve) 2nos. 25A TPN MCB (10kA) (C Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Ground Floor MDB complete as above
Ground Floor AHU MDB INCOMER : 1no. 100A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 160A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 2nos. 40A TPN MCB (10kA) (D Curve) 8nos. 16A TPN MCB (10kA) (D Curve) Inbuilt VRV indoor unit DB Incomer: 1no 25A DP MCB Outgoing: 3 nos 25A DP ELCB's 100mA 12 nos 16A SP MCB's 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Ground Floor AHU MDB complete as above Ground Floor Air Conditioning Panel
Ground Floor Air Conditioning Panel INCOMER 1no. 160A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 200A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 8nos. 40A TPN MCB (10kA) (D Curve) 2nos. 25A TPN MCB (10kA) (D Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Ground Floor Air Conditioning Panel complete as above
First Floor MDB ( Light and Power) INCOMER : 1no. 125A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 160A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 2nos. 63A TPN MCB (10kA) (C Curve) 5nos. 40A TPN MCB (10kA) (C Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . First Floor MDB complete as above
First Floor AHU MDB INCOMER : 1no. 100A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 160A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 3nos. 40A TPN MCB (10kA) (D Curve) 5nos. 16A TPN MCB (10kA) (D Curve) Inbuilt VRV indoor unit DB Incomer: 1no 25A DP MCB Outgoing: 3 nos 25A DP ELCB's 100mA 12 nos 16A SP MCB's 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . First Floor AHU MDB complete as above
First Floor Air Conditioning Panel INCOMER 1no. 160A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 200A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 8nos. 40A TPN MCB (10kA) (D Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . First Floor Air Conditioning Panel complete as above
Second Floor MDB ( Light and Power) INCOMER: 1no. 125A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 160A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 2nos. 63A TPN MCB (10kA) (C Curve) 7nos. 40A TPN MCB (10kA) (C Curve) 3nos. 40A DP MCB (10kA) (C Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Second Floor MDB complete as above
Second Floor AHU MDB INCOMER 1no. 160A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 200A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 6nos. 40A TPN MCB (10kA) (D Curve) 6nos. 16A TPN MCB (10kA) (D Curve) Inbuilt VRV indoor unit DB Incomer: 1no 40A DP MCB Outgoing: 3 nos 40A DP ELCB's 100mA 24 nos 16A SP MCB's 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Second Floor AHU MDB complete as above
Second Floor Air Conditioning Panel INCOMER 1no. 400A,36kA TP with isolatable neutral link MCCB with rotary operating handle with door interlock, with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type indication with and ON/ TRIP/OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 630A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 2nos. 63A TPN MCB (10kA) (D Curve) 16nos. 40A TPN MCB (10kA) (D Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Second Floor Air Conditioning Panel complete as above
Smoke Exhaust Panel INCOMER 1no. 250A,36kA TP with isolatable neutral link MCCB with rotary operating handle with door interlock, with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type indication with and ON/ TRIP/OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 400A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 1no. 40A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 2nos. 63A TPN MCB (10kA) (C Curve) 7nos. 40A TPN MCB (10kA) (C Curve) 9nos. 25A TPN MCB (10kA) (C Curve) 8nos. 16A TPN MCB (10kA) (C Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Smoke Exhaust Panel complete as above
Pressurisation MDB INCOMER 1no. 63A, 25kA TPN MCB with ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 125A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 5nos. 25A TPN MCB (10kA) (C Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Pressurisation MDB complete as above
Lift Panel Incomer: 1no. 125A 4P On-Load changeover switch connected as shown in the diagram. 1no. 125A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication. 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current, Frequency, Power, Energy, Power factor with RS 485 port and set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB 1 set of three phase indicating lamps with suitable protection. Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 160A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. 4nos. 16A HRC fuse with Class "II" surge arrestors, less then 1.5 kV, 40kA, 8/20 micro second, as per specification. Outgoings: 5nos. 40A TPN MCB (10kA) (C Curve) 5nos. 25A TPN MCB (10kA) (C Curve) 1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel . Lift Panel complete as above
External Lighting Feeder Pillar Designing, fabricating,testing and commissioning outdoor duty free standing IP54 feeder pillar made of 2mm thick CRCA sheet with double door (lockable outer door), sloping roof with water drip protection channel, suitable compression gaskets around all outer doors and MS angle stand as per approved drawing with switchgear and controls as required. Incomer : 1no 40A 25kA TP with accessible, isolatable neutral link thermal magnetic MCCB with rotary operating handle with door interlock, with O/L & S/C protection with time delay facility and fault type indication and ON /TRIP/ OFF indication 1nos DIN rail mounted 24hr dual channel analog timer with 3nos 40A DP contactors each connected to 40A DP MCB and 40A DP ELCBs (100mA) as shown in feeder pillar schematic diagram. BUS BAR: Bus bar: Equally sized three phase & neutral aluminium conductors busbar suitably sized to carry 125A current having a maximum current density of 1.0 amp per sq.mm and suitably insulated with coloured heat shrinkable PVC Sleeve i.e. RYB, BK as per colour code. Outgoings: 18nos 10A DP MCBs, 10kA (C Curve) 2 nos 25A TPN MCBs, 10kA (C curve) 1No. 25x6 mm GI earth Strip across the width of the panel. External Lighting Feeder pillar completed as above
SUB HEAD 6 : LT CABLE, CABLE TRY AND HUME PIPE Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . Core - 3.5 A2XFY 300 Sq.mm 3 and 1/2 core armoured cable
240 Sq.mm 3 and 1/2 core armoured cable
185 Sq.mm 3 and 1/2 core armoured cable
150 Sq.mm 3 and 1/2 core armoured cable
95 Sq.mm 3 and 1/2 core armoured cable
70 Sq.mm 3 and 1/2 core armoured cable
50 Sq.mm 3 and 1/2 core armoured cable
35 Sq.mm 3 and 1/2 core armoured cable
25 Sq.mm 3 and 1/2 core armoured cable
Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 4 Core, 2XWY 2XFY 4.00 Sq. mm.4 Core armoured
6.00 Sq. mm.4 Core armoured
10.00 Sq. mm.4 Core armoured
16.00 Sq. mm.4 Core armoured
SUPPLYING FITTING AND FIXING OF (DOWELLS/ COMET make) DOUBLE compression BRASS GLANDS WITH NICKEL - PLATED WEATHERPROOF (CBW) Size: 60.5 - 66, 3 "
WEATHERPROOF (CBW) Size: 52.5 - 56, 2 -1/2 "
WEATHERPROOF (CBW) Size: 46.5 - 52, 2 "
WEATHERPROOF (CBW) Size: 41.5 - 46, 2 "
WEATHERPROOF (CBW) Size: 33.5 - 37, 1- 1/2 "
WEATHERPROOF (CBW) Size: 30.5 - 33, 1- 1/2 "
WEATHERPROOF (CBW) Size: 26.5 - 30, 1- 1/2 "
WEATHERPROOF (CBW) Size: 23.5 - 26, 1- 1/4 "
WEATHERPROOF (CBW) Size: 20.5 - 23, 1 "
WEATHERPROOF (CBW) Size: 18.5 - 20, 1 "
WEATHERPROOF (CBW) Size: 16.5 - 18, 1 "
WEATHERPROOF (CBW) Size: 16.5 - 18, 3/4 "
WEATHERPROOF (CBW) Size: 12.5 - 16, 3/4 "
Supplying and fixing of following sizes of GI pre galvanized, 80-120 micron zinc coting, perforated/ Ladder type cable trays as specified including supports made from mild steel angles, 2nos 12mm threaded down rods located maximum 1000mm apart, fasteners and all hardware including proper finishing all supports with 2 coats of aluminium paint as required: (Note:- Cable tray load barring capacity should be as per IEC-61537) 40 x 150 x 40 x 2mm (Perforated).
40 x 300 x 40 x 2mm (Perforated).
40 x 450 x40 x 2mm (Perforated).
40 x 600 x40 x 2mm (Perforated).
450mm wide (Runner - 75x15x2mm, Rungs 35x15x2 mm, Spacing 250 mm center to center)
750mm wide (Runner - 100x20x2.5mm, Rungs 40x20x2.5 mm, Spacing 250 mm center to center)
1000mm wide (Runner - 100x20x2.5mm, Rungs 40x20x2.5 mm, Spacing 250 mm center to center)
Providing and laying of the following types & sizes of pipes including excavation and backfilling of trenches with proper base levelling and preparation with PCC where required in external spaces (excluding the cost of making suitably sized manholes) as specifed with brick plastered with water-proof compound and all required accessories for coupling, fixing and supports where required for internal use: 250/215 mm HDPE Double wall corrugated (DWC) pipe (Specification as per IS:14930) (laid underground in external spaces)
180/155 mm HDPE Double wall corrugated (DWC) pipe ( Specification as per IS:14930) (laid underground in external spaces)
125/105 mm HDPE Double wall corrugated (DWC) pipe (Specification as per IS:14930) (laid underground in external spaces)
SUB HEAD 7 : CEILING FAN, EXHAUST FAN & CABIN FAN Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Ventilator DX 250 mm sweep Louver type (ORIENT make), Brisk Air 250 mm sweep Louver type/ Trans Air 150 mm sweep (Crompton make), Ventil Air DX 150 mm sweep Louver type (Havells make)
SUB HEAD 8 :ELECTRICA STORAGE WATER HEATER (GEYSER) Supplying and fitting fixing of Electric storage water heater [Geyser] of Bajaj/Crompton/Racold/V. Guard or equivalent make including necessary connection cable, as approved by the Deptt.)etc. as required complete and as directed by the Department. Horizontal Type 15.00 litres. Capacity (5 Star Model) (Crompton/Racold/V. Guard or equivalent make)
SUB HEAD 9: LUMINARIES Supplying, installation, testing and commissioning of the following prewired CFL/ Flourescent/ LED luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection with 1.5 sq. mm PVC insulated single core copper conductor as required and directed by the Deptt. 40W, Recessed LED Downlight fixture with 4000 Lumen output, cool white/ warm white (as per client approval) color temperature Philips RS 271B LED 40 / 840 PSU-E WB 40W COB Wide beam LED recessed downlighter or approved equivalent..
20W, Recessed LED Downlight fixture with 4000 Lumen output, cool white/ warm white (as per client approval) color temperature Philips RS 271B LED 40 / 840 PSU-E WB 20W COB Wide beam LED recessed downlighter.
22W Surface, Ceiling/ Wall mounted or suspended type LED fixture with 2500 Lumen output, warm white (4000K) color temperature Philips Cat no.smart bright extra batten,BN 021 LED 25S PSU GR S1 or approved equivalent.
6W, Surface mounted LED Downlight fixture with 750 Lumen output, warm white (4000K) color temperature Philips Cat no. SM250C LED 7S or approved equivalent..
12W, Surface mounted LED Downlight fixture with 1200 Lumen output, warm white (4000K) color temperature Philips Cat no. SM250C LED12S.or approved equivalent..
12W, Recessed mounted LED Downlight fixture with 1200 Lumen output, cool white color temperature Philips Cat no. DN193B LED12S.or approved equivalent..
12W/m LED tape with aluminium profile with PC clear/ Opal matte diffuser with end cap and metal clips,cool white/ warm white (as per client approval) color temperature K-Lite Cat no.3084 ( for aluminium profile) and 7281( for 12W/m tape) or equivalent make.
3W LED step light cool white/ warm white (as per client approval) color temperature K-Lite Cat no. 2749 or equivalent make.
SUB HEAD 10 : EARTHING Supply, installation & testing of G.I. Plate earth station with 600 mmx600 mmx6 mm heavy duty G.I. earth plate with necessary 40 mm dia. G.I. watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm hinged cover C.I. cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 25 X 5 mm size G.I strips drawn on surface from earth electrode to electrical switch gears, machineries etc complete with supply of G.I nuts & bolts ,screws etc including riveting , soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing 20 mmx3 mm Copper strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of Brass Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode copper strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
SUB HEAD 11 : FIRE DETECTION & SECURITY SYSTEM Supplying, installing, testing and commissioning of Microprocessor based 10 loop capacity having 4 loop working in present and should be expendable upto 10 loop in future if required, Networkable analogue addressable type fire alarm control panel with 640 character LCD display, each loop shall have a minimum capacity of 100 analog addressable detectors in one loop. The panel shall have integrated QWERTY Keypad, 4000 History logging event, Four access levels, capable of taking Flash Scan devices, flash EPROM, sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, The Panel shall have Integrated Digital Voice Emergency Evacuation, Digital 2 Way communication & BACKNET CARD for integration. 240 volts AC power supply, automatic supervised battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 Minutes in emergency conditions as required. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers.
Supplying, installing, testing and commissioning of GUI based main network software capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems and/ or sensors’ locations. The GUI software shall be located in control room and shall be capable of monitoring fire detectors & devices and operating Digital Voice Evacuation & 2 Way Communication for all the blocks System connected with each other. The software shall be capable of monitoring 100 Nodes with 100 MB baud Transmission rate on Fibre Optics Network. (UL 9th Edition Listed)
Supplying, installing, testing and commissioning of Web Server to connect Fire Alarm Control Panels via Internet/Intranet and/or dialup to Internet Explorer Web Server. (One TCP / IP address and one email ID is required)
Supplying, Installation, Testing and Commissioning of Network Repeater Panel with 6 inch or 640-characters; The LCD shall Display all events / detectors, devices status of complete systems in the networked, The NRP shall be equipped with QWERTY Keypad. Mounting options include an annunciator box, and blank modules are required for mounting.
Supplying, Installation, Testing and Commissioning of Fibre Optics Network Card for Fire Network. The card shall have minimum 100 Mb Baud Transmission Rate to accomadate Fire detection, Digital Voice & Fire Fighters Telephone network (UL Listed) (To be used with panels, Software, Repeators, DVC and other Nodes required as per system) Shall be UL Listed and same make of panel.
Supplying, Installation, Testing and Commissioning of Repeater Panel with 6 inch or 640-characters; The LCD shall Display all events / detectors, devices status of complete systems in the networked, The repeator panel shall be equipped with QWERTY Keypad. Mounting options include an annunciator box, and blank modules are required for mounting.
Supplying, Installation, Testing and Commissioning of Multi-criteria Cooperative Sensing Type Analog addressable Photoelectric smoke & heat detector with mounting based LED, Address Switch from 01-159 , complete as required.
Supplying, Installation, Testing and Commissioning of Multi Cooperative Sensing Type Analog addressable Photoelectric smoke detector with mounting based LED, Address Switch from 01-159 , complete as required.
Supplying, Installation, Testing and Commissioning of Automatic Floating Sensitivity type Analog addressable Acclimate Photo thermal smoke detector with mounting based LED, Address Switch to programme the detectors, complete as required. (In Changing Environment Area).
Supplying, Installation, Testing and Commissioning of Addressable type fault for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model).
Supplying, Installation, Testing and Commissioning of Addressable control modules for Hooters / Sounders / Strobes etc.
Supplying, Installation, Testing and Commissioning of Addressable control modules for Fire Fighters Telephone circuit.
Supplying, Installation, Testing and Commissioning of Addressable control relay modules for AHU & lift and stairs Pressurization Fan.
Supplying, Installation, Testing and Commissioning of Addressable control relay modules for Access control Integration.
Supplying, Installation, Testing and Commissioning of Addressable monitor modules for Sprinkler Flow Switch and Door Holders.
Supplying, Installation, Testing and Commissioning of Response indicator - Local Approved.
Supplying, Installation, Testing and Commissioning of Addressable Manual Pull Station .
Supplying, Installation, Testing and Commissioning of Directional Sounders with strobe light 110cd & 20 hz to 20 khz operating frequency with minimum 8 distinct sound patterns to indicate corridors, Exit doors, Move upward, move down ward etc. to direct Occupants for fast & safe Evacuation as specified in NFPA 72 - 2007 edition.
Supplying, Installation, Testing and Commissioning of Fire panel supervised 70db-84db Wall Mounted Hooter Cum strobe as specified & same make as of panel.(For outdoor area)
Supplying, Installation, Testing and Commissioning of Addressable Digital 100 W, total output power at 70.7 Vrms Amplifier with inbuilt 8 Addressable zone circuits and one Addressable Fire Fighters Telephone Circuits. The amplifier shall have inbuilt battery charger. The amplifiers shall be placed in the field on different designated floors with all acessories like cabinet etc required to complete the installation
Supplying, Installation, Testing and Commissioning of Fire panel supervised 70db-84db Ceiling Mounted Hooter Cum Speakers as specified & same make as of panel.
Supplying, Installation, Testing and Commissioning of 2 way communication Fire Fighter's Telephone Jack
Supplying, Installation, Testing and Commissioning of 2 way communication Fire Fighter's Handset
Supply and drawing of 2 C X 1.5 Sq mm twin twisted shielded, HPSR Insulated copper Unarmoured fire survival cable, complete with termination and testing as per requirement as per BS-7629.
Supply and drawing of 2 C X 1.5 Sq mm multi-strand twin twisted shielded, Mica Tape Insulated, copper Armoured fire survival cable, complete with termination and testing as per requirement as per BS-7846.
Supply and drawing of 2 C X 2.5 Sq mm twin twisted shielded, HPSR Insulated copper Unarmoured fire survival cable, complete with termination and testing as per requirement as per BS-7629.
Providing & laying the following armoured fiber cable: 62.5/125 micrometers (multi-mode); 50/125 micrometers (multimode), or 9/125 micrometers (singlemode). Maximum attenuation is 10 dB with 62.5/125 μm cable, The single/Multimode fibre optics network shall be used for Fire detection, Digital Voice & Fire fighters Telephone for data transfer (100 Mb). The Cable shall be layed under ground from one block to another block underground with all accessories.
SUB HEAD 12 : CCTV SURVEILLANCE Supplying, Installation, Testing and Commissioning of IR-DOME CAMERA: 1/3" 4 MP progressive scan imager 2688 x 1520 resolution 2.8 mm fixed lens True day/night (IR-cut filter) Wide Dynamic Range up to 120 dB Low-light performance down to 0.01 lux (color) or 0 lux with IR LEDs on Up to 98 ft (30 m) IR illumination, depending on scene reflectance H.265 Smart Codec Dual stream support PoE (802.3af) or 12 VDC support IP66 and IK10-rated rugged housing with all acessories as required to complete the installation.
Supplying, Installation, Testing and Commissioning of IR-BULLET CAMERA: 1/3" 4 MP progressive scan imager 2688 x 1520 resolution 3.6 mm Fixed lens True day/night (IR-cut filter) Wide Dynamic Range up to 120 dB Low-light performance down to 0.08 lux (color) or 0 lux with IR LEDs on Up to 98 ft (30 m) IR illumination, depending on scene reflectance H.265 Smart Codec Dual stream support PoE (802.3af) or 12 VDC support IP66 and IK10-rated rugged housing with all acessories as required to complete the installation.
Supplying, Installation, Testing and Commissioning of IR-BULLET CAMERA Varifocal with Motersied Zoom 1/3” 4 MP progressive scan image 2688 x 1520 resolution 3.7 - 13.5 mm MFZ lens True day/night (IR-cut filter) Wide Dynamic Range up to 120 dB Low-light performance down to 0.03 lux (color) or 0 lux with IR LEDs on Up to 164 ft (50 m) IR illumination, depending on scene reflectance H.265 Smart Codec Dual stream support Support up to 128GB Micro SDHC card class 10 PoE (802.3af) or 12 VDC support IP66 - rated housing with all acessories as required to complete the installation.
Supplying, Installation, Testing and Commissioning of 32 channel NVR with H.265/H.264/MJPEG/MPEG4 codec decoding 2 HDMI/VGA simultaneous video outputs UL listed Supports up to 32 alarm input channels and 6 alarm relay output channels Supports sending notifications through email, FTP, and/or HTTP Supports recording a video clip of events for distribution Supports uploading still images at the time of the event through email and/or FTP Configurable to automatically detect and respond to motion in the scene, alarm inputs, and network failure or tampering Maximum incoming bandwidth of 320 Mbps Supports.
Supplying, Installation, Testing and Commissioning of Water proof Junction Box for Outdoor Camera with all acessories as required to complete the installation.
Supplying, Installation, Testing and Commissioning of 6 TB HDD with all acessories as required to complete the installation.
Supplying, Installation, Testing and Commissioning of 24 PORT POE SWITCH with all acessories as required to complete the installation.
Supplying, Installation, Testing and Commissioning of 10 PORT POE SWITCH with all acessories as required to complete the installation.
Supplying, Installation, Testing and Commissioning of 15U Rack with all acessories as required to complete the installation.
Supplying installation testing of UTP CAT6 Cable without PVC conduit
Supply and fixing 25 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required:
SUB HEAD 13 : APDCL CLEARANCE Preparation of drawings/documents in required sets to be submitted to APDCL Office for sanction and obtaining the required load, all required clearance and approvals from APDCL prior to connect the Transfomer.
FIRE FIGHTING WORKS (D) FIRE ALARM SYSTEM (CONVENTIONAL TYPE) 4 - ZONE Conventional type fire Alarm Control Panel with 240 volts AC power supply, 24 volts sealed battery, battery charger complete in all respect. MAKE-SYSTEM SENSOR/AGNI
Conventional type Manual call point with necessary suports, chipping, chasing / civil work, concealed work of cabling/conduit, cable termination, gland. MAKE-SYSTEM SENSOR/AGNI
Electronic Hooter cum speaker 6 watts capacity including base as required. MAKE-SYSTEM SENSOR/AGNI
Conventional type Smoke Detector with necessary suports, chipping, chasing / civil work, concealed work of cabling/conduit, cable termination, gland. MAKE-SYSTEM SENSOR/AGNI
Conventional type Heat Detector with necessary suports, chipping, chasing / civil work, concealed work of cabling/conduit, cable termination, gland. MAKE-SYSTEM SENSOR/AGNI
Conventional type Beam Detector with necessary suports, chipping, chasing / civil work, concealed work of cabling/conduit, cable termination, gland. MAKE-SYSTEM SENSOR/AGNI
2C X 1.5 sq. mm copper conductor PVC insulated flexible FR wires MAKE - FINOLEX, HEVELLS.
20 mm dia PVC rigid conduit and necessary tee, bend, saddle, elbow etc fittings as required.
FIRE PUMP HOUSE Supply, installation, testing and commissioning of electrically driven high pressure centrifugal fire hydrant pump, suitable for automatic operation consisting of the following: FIRE HYDRANT PUMPS Electric driven main Fire Pump for manual / automatic operation as per specifications as required and consisting of the following : complete in all respect as required. 1 No. horizontal centrifugal fire pump capable of delivering 2280 LPM of water against a total head of 70 mtrs. 1 No. squirrel cage induction motor conforming to IS : 325 with class F insulation, TEFC type conforming to relevant protection class of IS: 4691 synchronous speed of 2900 RPM Common bed plate fabricated out of MS channel of suitable size for assembling the pump and the motor, flexible coupling and with coupling guard for protection / safety. Vibration isolation by providing cushy mount pads as necessary, foundation bolts, brackets, clamps, fixtures, grouting in accordance with manufacturer's design etc. complete as reqd.
JOCKEY PUMP (pressurisation pump) comprising of the following: Electric driven Jockey / Pressurisation pump set (Vertical type) for Wet Riser system suitable for manual / automatic operation as per specification as required and consisting of the following : complete in all respect as required. 1 No. horizontal pressurisation pump having 10% rated discharge of the main fire pump at a head of 70 mtrs (Same of the main fire pump). 1 No. squirrel cage induction motor conforming to IS: 325 with class F insulation TEFC type conforming to relevant protection/safety class of IS:325, synchronous speed of 2900 RPM. Common bed plate fabricated out of MS channel of suitable size for assembling the pump and the motor, flexible coupling and with coupling guard for protection/safety. For pump defined above duty as follows: For Hydrant & Sprinkler System Flow : 180 LPM and Head : 70 mts
Supply, erection, testing & commissioning of compartmentalised common control panel for Electrical Motor driven pumps as per technical specification attached with this tender document. All components shall be housed in a common cubicals made of 16 swg. M.S. sheet with required stiffners(if required). The panel shall be powder quoted of approved colour both inside and out side. The panel shall have both bottom and top cable entry provisions and panel shall be mounted on pedestal of 300mm height. The panel should have sufficient (min. 3 nos per pump set) NO / NC contacts for extending the status of fire pumps to the fire alarm panel.
Supply, laying, testing & commissioning of FRLS, PVC outer sheath, steel armoured, aluminium / copper conductor, 1100 Volt Grade power cables with gland etc. 3C x 50 sq.mm for main pump
3C x 6 sq.mm for Jockey Pump
12C x 2.5 Sq.mm for Diesel Engine
2C x 1.5 sq.mm for instrumentation
Supply and fixing of 150 mm x 75 mm GI perforated cable tray with necessary angle iron suspension supports, anchor fasteners etc complete.
Supply and fixing of 75 mm x 50 mm GI perforated cable tray with necessary angle iron suspension supports, anchor fasteners etc complete.
GI earthing strips of 25mm x 6mm thick, strips shall run on floor / ceiling / walls, from pump to control panel with necessary accessories as required.
Supply and installation of Pressure gauge, 1/2 inch bottom entry, of suitable range for pump set with ball valves and other accessories.
Supply and installation of Pressure switches, SPDT type, of suitable range for pump sets with ball valves and other accessories.
Supply, erection, fabrication, testing of MS black steel pipe Heavy grade conforming to IS : 1239 Part -1 /3589 including all fittings viz. Elbows, tees, flanges, etc. reduces clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the complete with cutting and making good the walls, floors or any other surface. 200 NB
Supply, installation, testing & commissioning of CI Butterfly valve as per BS :5155 (Wafer type) matching flanges complete with nuts & bolts. 150 NB
Supply, installation, testing & commissioning of CI Wafer type, Duel plate Non return Valve as per IS:5312 (PN16 ) including matching flanges, nuts & bolts complete. 150 NB
Providing and fixing of CI Foot valve with flanged end, rubber seat as per IS 4038. 150 NB
Providing and fixing of the following for Pipe supports, Battery Stand, Panel Stand, etc. ISA (65X65X6)
M.S. Flat (75x8)
M.S. Plate 8 mm. thickness
Providing and fixing of 500 Ltrs. PVC Type Priming tank with necessary pipe and fittings. 500 Ltrs.
Supply, installation, testing & commissioning of CI Wafer type, Duel plate Non return Valve as per IS:5312 (PN16 ) including matching flanges, nuts & bolts complete. 25 NB
Providing and installation of GM Ball Valve, IS-318 LTB-2 SS Stem AISI 410, Ball SS 304/CF8, teflon gland packing, screwed female threads to IS-554. 50 NB
HYDRANT SYSTEM Supply, erection, fabrication, testing of MS black steel pipe Heavy grade conforming to IS : 1239 Part -1 /3589 including all fittings viz. Elbows, tees, flanges, etc. reducers clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the complete walls, floors or any other surface. 150 NB
Providing & fixing SS Single headed fire hydrant valve with 80 mm N.B. flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS:5290 standards. Including fixing with anchor fastner and flanged tapping from wet riser complete as required.
Providing & fixing controlled percolation fire hose pipe (as per IS:8423) of 63 mm dia and 7.5 meter length rated for brust pressure of 35.7 Kg/sqcm. The hose shall be tested for flame resistance test in accordance to IS:8423. Hose shall be complete with ISI marked brass male & female coupling (IS:903) bound & riveted to hose pipe with copper rivets & 1.5 mm copper wire.
Providing and Fixing 63 mm dia instantaneous pattern Stainless Steel branch short Pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
Providing and Installation of Fire Hose cabinet wall mounted type made out of 18 SWG MS sheet with front glass and key to accommodate two hoses of 15m long and one clamp for fitting branch pipes and fixing hooks with louvers. 750mm. X 600mm. x 250mm. For Internal
Providing & fixing swinging type First Aid hose reel in red colour drum with 30 mts long and 20 mm dia heavy duty rubber water hose including 20 mm dia ball valve, terminating with G.M. coupling & nozzle of 6mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastner, bolts & nuts conforming to IS:884-1969 complete as required.
Providing and fixing gunmetal single acting Air release valve with screwed inlet 25 mm dia as per IS 12992 rated for 20 Kg/Sq.cm incluing 25 mm dia GM Ball Valve as per IS-318 LTB2.
Providing & fixing dial type (100 mm dia) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.
Providing & fixing SS fire brigade inlet connection consisting of 4 Nos. 63 mm dia instantaneous type male couplings with built-in check valves, 1 No. 150 mm dia Butter Fly valve and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as required and as per IS standards.
Providing and fixing of the following for Pipe supports: ISA (65X65X6)
Supply, installation, testing & commissioning of CI Butterfly valve as per BS :5155 (Wafer type) matching flanges complete with nuts & bolts. 150 NB
Supply, installation, testing & commissioning of CI Wafer type, Duel plate Non return Valve as per IS:5312 (PN16 ) including matching flanges, nuts & bolts complete. 150 NB
SPRINKLER SYSTEM Supply, fabrication, erection & testing of MS black steel pipe Heavy grade conforming to IS : 1239/3589 including all fittings viz. Elbows, tees, flanges, etc. reducers, clamps, MS support dash fasteners etc. including painting the pipe with two coats of approved red oxide primer and two coats of approved red enamel paint and welded joints complete with cutting and making good the complete walls, floors or any other surface. 150 NB
Supply, installation, testing & commissioning of CI Butterfly valve as per BS :5155 (Wafer type) matching flanges complete with nuts & bolts. 150 NB
Providing & Fixing of Installation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer's specifications complete as required. 150 NB
15mm dia. Chrome finished sprinkler head as per IS:9972 with standard response 5mm quartz bulb complete. Pendent sprinkler 68 deg C
Sidewall sprinkler 68 deg C
Kitchen sprinkler 79 deg C
Providing and fixing gunmetal single acting Air release valve with screwed inlet 25 mm dia as per IS 12992 rated for 20 Kg/Sq.cm incluing 25 mm dia GM Ball Valve as per IS-318 LTB2.
Providing & fixing dial type (100 mm dia) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.
HVAC WORKS (E ) LOW SIDE AC AIR HANDLING UNITS (AHUs) Floor Mounted Horizontal AHUs - With Thermal Break Profile and Mixing Chamber Supply, Installation, Testing and Commissioning of DX type double skin air handling units (AHUs) each comprising of following as per the specifications : Casing of air handling units shall be in double skin construction. Inner skin shall be constructed out of 24 gauge plain GS sheet & outer skin in 24 gauge pre-plasticized GS sheet sandwitched between 50mm thick injected PU foam insulation of density not less than 40 Kg /CuM and complete with inspection doors and marine light, limit switch including control wiring as required. AHUs shall be provided with thermal break profile. Fan section complete with backward curved DIDW type centrifugal fan/s, IP-55, IE3, TEFC squirrel cage induction motor suitable to operate on 415+10%V, 50Hz,3 phase AC power supply and belt drive package. Fan outlet velocity shall not be more than 1600 FPM (8.13MPS). Motors shall be VFD compatible. All fans should be AMCA certified. Fan section should be completed with 25mm thick Armasound acoustic insulation. Coil section with multirows deep DX type coil of copper tube & copper header and aluminium fins construction having wall thickness of tubes not less than 0.5mm. Drain pan shall be made out of 18 gauge stainless steel duly insulated. Face velocity across cooling coil shall not exceed 500 FPM. Pre-Filter (EU-4) section complete with 50mm thick washable synthetic fibre filters. Velocity across the filters shall not exceed 500 FPM. Fine filter section complete with fine filters. Velocity across fine filters shall not exceed 500FPM. Filters shall have efficiency not less than 95% down to 1 Micron (EU-8/MERV-14). AHUs shall be provided with mixing chamber with R/A & F/A openings with dampers as per approved shop drawing. Multiblade box type zero leakage manually operated extruded aluminium volume control dampers shall be factory fitted at outlet of each AHU. In addition to the above, air handling units shall be provided with spring type vibration isolators and fire retardent flexible canvass connections made out of canvass sleeve. Sizes of air handling units shall not exceed as mentioned in the design drawings and air handling units shall conform to the design parameters mentioned in specifications. The Air Handling Units (AHUs) shall be of following duty parameters : AHU No Capacity S.P Motor Rows of Area to AH-2/Audi-GF 17.6/6000 70-75 7.5 6 Audi-1,GF
AH-6/Audi-FF 32/9500 70-75 10 6 Audi-2,FF
AH-11&12/Audi-SF 35.2/11500 70-75 10 6 Audi-3,SF
Ceiling Suspended AHUs - With Thermal Break Profile and Mixing Chamber Supply, Installation, Testing and Commissioning of double skin air handling units (AHUs) each comprising of following as per the specifications : Casing of air handling units shall be in double skin construction. Inner skin shall be constructed out of24 gauge plain GS sheet & outer skin in 24 gauge pre-plasticized GS sheet sandwitched between 25mm thick injected PU foam insulation of density not less than 40 Kg /CuM and complete with inspection doors and marine light,limit switch including control wiring as required. AHUs shall have access for all parts Fan section complete with forward curved DIDW type centrifugal fan/s, EFF1 TEFC squirrel cage induction motor suitable to operate on 415+10%V, 50Hz, 3 phase AC power supply and belt drive package. Fan outlet velocity shall not be more than 1800 FPM (9.2MPS). Fan section should be completed with 25mm thick Armasound acoustic insulation. Coil section with multirows deep chilled water coil of copper tube & copper header and aluminium fins construction having wall thickness of tubes not less than 0.5mm. Drain pan shall be made out of 18 gauge stainless steel duly insulated. Face velocity across cooling coil shall not exceed 500FPM. Pre-Filter section complete with 50mm thick washable synthetic fibre filters. Velocity across the filters shall not exceed 500 FPM. AHUs shall be complete with suspension arrangement,it shall also include spring type vibration isolators and rubber groomets etc. to make the installation totally vibration free. AHUs shall have separate compartment for housing of all valves or extended insulated auxiliary drain tray. In addition to the above, air handling units shall be provided with fire retardant flexible canvass connections made out of canvass sleeve. Sizes of air handling units shall not exceed as mentioned in the design drawings and air handling units shall conform to the design parameters mentioned in specifications. Multiblade box type zero leakage manually operated extruded aluminium volume control dampers shall be factory fitted at outlet of each AHU. AHUs shall be provided with mixing chamber with R/A & F/A openings as per approved shop drawing. The Air Handling Units (AHUs) shall be of following duty parameters : AHU No Capacity S.P Motor Rows of Area to (TR/Cfm) (mmWG) Rating coil be fed (HP) AH-1/Passage-GF 11.2/4500 36-38 3 6 Passage,GF
AH-3/Lobby-GF 9.6/4000 36-38 3 6 Reception/Lobby,GF
AH-4/Restaurant-GF 14.4/4000 36-38 3 6 Restaurant,GF
AH-5/Passage-FF 11.2/4500 36-38 3 6 Passage,FF
AH-7/Lobby-FF 9.6/4000 36-38 3 6 Lobby,FF
AH-8/Passage-SF 11.2/5000 36-38 3 6 Passage,SF
AH-9/Lobby-SF 9.6/4000 36-38 3 6 Lobby,SF
AH-10/Passage-SF 12.8/5000 36-38 3 6 Passage,SF
KIT FOR AHUs Supply, Installation, Testing and Commissioning of VRV Kits for AHUs having all controllers & Electonic Expansion Valve (EEV) and temperature set arrangment. It Shall have cut off arrangement after a particular set value of Supply air Temperature. Price should include all control cabling etc./ accessories and all necessary arrangements whether mentioned or not to make the system working For 10HP
For 12HP
For 14HP
For 16HP
For 18HP
For 20HP
VARIABLE FREQUENCY DRIVES Supply, Installation, Testing and Commissioning of variable frequency drives for following Air Handling Units. Variable frequency drives shall be provided with necessary sensors and transmitters complete with control wiring in all respect as required and as per specifications. VFDs shall have built-in harmonic filters. The drives shall be suitable for the following motor rating. VFDs shall be housed in precoated, IP-55, vandal proof enclosure with On/Off Push Buttons, Phase indication lights, A/M Switch and with adequate provisions for ventilation using a fan. The VFDs shall be able to receive the signals from multiple/combination of duct static pressure sensors/Temp. sensors and to ramp the speed of the motor.VFDs shall be suitable to take feed back and connectivity from all the DPS as mentioned below against each motor rating to facilitate averaging activity by VFD. Quoted price shall be inclusive of return air temperature sensor and necessary electrical switches including change over switch & copper cabling for integration with the AHU panel. VFDs shall be installed within Electrical panels as described under Section 'Electrical Works'. (i) Sensing Range : 10mm to 50 mm WG (ii) Output Signal : 4 mA to 20 mA OR 0 V to 10 V DC 10HP
Ceiling Suspended type FFU for Fresh Air Supply, Installation, Testing & Commissioning of Fan Filter Units (FFU) comprising of following as per the specifications : Casing of air handling units shall be in double skin construction. Inner skin shall be constructed out of 24 gauge plain GS sheet & outer skin in 24 gauge pre-plasticized GS sheet sandwitched between 25mm thick injected PU foam insulation of density not less than 40 Kg /CuM and complete with inspection doors including control wiring as required.FFUs shall have access for all parts. FFUs shall be provided with thermal break profile. Fan section complete with forward curved DIDW type centrifugal fan/s, IP-55, EFF1 TEFC squirrel cage induction motor suitable to operate on 415+10%V, 50Hz, 3 phase AC power supply and belt drive package. Fan outlet velocity shall not be more than 1800 FPM (9.2MPS). Fan section should be completed with 25mm thick Armasound acoustic insulation. Motors shall be VFD compatible. All fans should be AMCA certified. Pre-Filter section complete with 50mm thick washable synthetic fibre filters. Velocity across the filters shall not exceed 500 FPM. FFUs shall be provided with mixing chamber with F/A openings as per approved shop drawing. FFUs shall be complete with suspension arrangement, it shall also include spring type vibration isolators and rubber groomets etc. to make the installation totally vibration free. Multiblade box type zero leakage manually operated extruded aluminium volume control dampers shall be factory fitted at outlet of each FFU. In addition to the above, Fan Filter Units shall be provided with fire retardant flexible canvass connections made out of canvass sleeve. Sizes of Fan Filter Units shall not exceed as mentioned in the design drawings and air handling units shall conform to the design parameters mentioned in specifications. FFU shall be provided with mixing chamber & thermal break profile. The Fan Filter Unitss (FFUs) shall be of following duty parameters : AHU No Capacity S.P Motor Area to (Cfm) (mmWG) Rating be fed (HP) FFU-1 1700 25-26 1.5 Ground Floor
FFU-2&3 700 25-26 1.0 1st & 2nd Floor
FFU-4 800 25-26 1.0 2nd Floor Upper deck
VENTILATION FANS INLINE FANS (Single Phase) Supply, Installation,Testing & Commissioning of circular /rectangular inline fans for exhaust air complete with sheet metal casing, direct driven centrifugal fan, motor with proper protection and inspection door. Fan shall be suitable for operation on 220±6 % volts, 50 Hz,1phase AC power supply. Flanges to be provided on both sides to facilitate duct connections. Fan shall be installed as shown in the drawings and will be of following characteristics : All single phase inline fans shall be provided with factory fitted speed regulators. All Fans Should be complete with Plug Top & necessary power cable. Fan Capacity S.P Area to No. (Cfm) (mmWG) to be exhausted Ground Floor IF-1(Rect) 1200 12-13 G-Rest Room
IF-2(Circular) 850 12-13 L-Rest Room & Handi. Toi.
IF-3(Circular) 400 12-13 Washing Area
IF-4(Circular) 250 12-13 Electrical Room
IF-5(Circular) 200 12-13 Toilet adj. Store
First Floor IF-1(Rect) 1250 12-13 G-Rest Room & Handi. Toi.
IF-2(Circular) 900 12-13 L-Rest Room
IF-3(Circular) 250 12-13 Electrical Room
IF-4(Circular) 200 12-13 Toilet adj. Pantry
IF-5(Circular) 100 12-13 Pantry
Second Floor IF-1(Rect) 2200 12-13 G-Rest Room
IF-2(Rect) 1600 12-13 L-Rest Room & Handi. Toi.
IF-3(Circular) 250 12-13 Electrical Room
IF-4(Circular) 200 12-13 Toilet adj. Pantry
IF-5(Circular) 100 12-13 Pantry
Second Floor Upper Deck IF-1(Circular) 150 12-13 Toilet adj. Guest Room
IF-2(Circular) 250 12-13 Electrical Room Note : All major equipment shall be compatible with BMS.
PIPING COPPER REFRIGERANT PIPING Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications.MS sleeves of requisite size shall be provided at wall crossing. Quoted price shall be inclusive of necessary glass cloth and minimum two layers of UV protection paint to be applied over insulation for all exposed pipes of approved make. Piping shall be of following sizes : Internal Refrigerant piping in exposed ceiling area & external refrigerant piping shall be laid on Ladder type cable trays. Cable trey used for external refrigerant piping shall be covered with cover. Pipe Size Thickness of CSE (O.D.) Insulation 41.3 mm 19 mm
CONDENSATE DRAIN PIPING-GI Supply, Installation , Testing and Commissioning of GI medium class (Class 'B') pipes cut to requird lengths and installed with all screwed joints for condensate drain. Quoted price shall be inclusive of supply and fixing in position the necessary fittings like elbows, tees reducers etc. and supporting arrangement in accordance with the approved shop drawings and specifications. Pipes shall be insulated with 9mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form . Pipes shall be of following sizes : 50mm dia
40mm dia
32mm dia
25mm dia
CONDENSATE DRAIN PIPING -cPVC Supply, Installation, Testing and Commissioning of cPVC pipes cut to required lengths and installed for condensate drain. Quoted price shall be inclusive of supply and fixing in position the necessary fittings like elbows, tees reducers etc. and supporting arrangement in accordance with the approved shop drawings and specifications. Pipes shall be insulated with 9mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form . Pipes shall be of following sizes : 50mm dia
40mm dia
32mm dia
25mm dia
900mm to 1200mm -- 24G GSS with TDC Joints
1201mm to 1800mm - 22G GSS with TDC Joints
1801mm to 2100mm - 20G GSS with TDC Joints
2101mm to 2700mm - 18G GSS with TDC Joints Notes: Ducting associated with Auditorium Hall shall be 24G minimum.
SITE FABRICATED DUCTING Supply, Fabrication, Installation and Testing of sheet metal ducts complete with vanes, splitter dampers, hanging arrangement including check nuts in accordance with the approved shop drawings and specifications. a. 0.63mm (24 gauge) GSS
b. 0.8 mm (22 gauge) GSS
c. 1.0mm (20 gauge) GSS
d. 1.25mm (18 gauge) GSS
FLEXIBLE CANVASS CONNECTIONS Supply, Installation, Testing of 125mm deep antivibration flexible joints at the outlet of air handling units/ductable split units/inline fans. Flexible connections shall be constructed using imported fire retardant fabric with extruded aluminium frame/flange on both sides of approved make.
LINEAR GRILLES Supply, Installation , Testing and Balancing of one way blow linear supply cum return air grilles complete with fixed core as per approved shop drawings and specifications. The grilles shall be of approved colour & shade. Powder coated aluminium grilles of extruded sections with integral flanges on both sides & ends as required complete with corner pieces. i. 100/150/200/250 mm High grilles
AIR TRANSFER GRILLES Supply, Installation and Testing of extruded aluminium powder coated air transfer grilles to be provided at the door of toilets/pantry.
SUPPLY AIR DIFFUSERS Supply, Installation, Testing and Balancing of square supply air diffusers with removable key operated volume control dampers with opposed blades as per the approved shop drawings and specifications.The diffusers shall be anti-smudge ring type/flat type as approved by the interior designer. Diffusers shall be with removable core for the following neck sizes. The diffusers shall be suitable for fixing in the gypsum/grid ceiling. The diffusers shall be of regular type and with outer dimension of 450 x 450mm, 375mmx375mm & 300mmx300mm. Powder coated extruded aluminium diffusers of approved colour & shade.
Supply, Installation, Testing and Balancing of square supply air diffusers with removable key operated volume control dampers with opposed blades & 150mm high GSS plenum as per the approved shop drawings and specifications.The diffusers shall be anti-smudge ring type/flat type as approved by the interior designer. Diffusers shall be with removable core for the following neck sizes. The diffusers shall be suitable for fixing in the gypsum/grid ceiling. The diffusers shall be of regular type and with outer dimension of 600 x 600mm. 600x600 Powder coated extruded aluminium diffusers of approved colour & shade suitable for fixing in grid ceiling.
RETURN AIR DIFFUSERS Supply, Installation,Testing and Balancing of square return air diffusers same as supply air diffusers but without volume control dampers as per the approved shop drawings and specifications. The diffusers shall be anti -smudge ring type. Powder coated extruded aluminium diffusers of approved colour & shade.
Supply, Installation, Testing and Balancing of square return air diffusers same as supply air diffusers but without volume control dampers as per the approved shop drawings and specifications. The diffusers shall be anti -smudge ring /flat type. 600x600 Powder coated extruded aluminium diffusers of approved colour & shade suitable for fixing in grid ceiling.
ROUND DIFFUSERS Supply, Installation, Testing and Balancing of round supply air diffusers with removable key operated butterfly volume control dampers as per the approved shop drawings and specifications.The diffusers shall be anti-smudge flush type as approved by the interior designer. Diffuser shall be complete with GI cone with circular connection at the rear. Powder coated extruded aluminium diffusers of approved colour & shade suitable for fixing in exposed duct or in grid/gypsum ceiling as per approved shop drawing. With Volume Control Dampers 200mm dia Neck Size round diffuser with GI cone
Supply, Installation, Testing and Balancing of round supply air diffusers with removable key operated butterfly volume control dampers as per the approved shop drawings and specifications.The diffusers shall be anti-smudge flush type as approved by the interior designer. Diffuser shall be complete with GI cone with circular connection at the rear. Powder coated extruded aluminium diffusers of approved colour & shade suitable for fixing in exposed duct or in grid/gypsum ceiling as per approved shop drawing. Without Volume Control Dampers 200mm dia Neck Size round diffuser with GI cone
Supply, Installation, Testing and Balancing of linear slot diffusers with Hit & Miss type extruded aluminium volume control dampers at supply air outlets as per the approved shop drawings and specifications. 3 slot/2slot, powder coated extruded aluminium diffusers of approved colour & shade for supply air with Hit & Miss type dampers
Supply, Installation, Testing and Balancing of linear slot diffusers with Hit & Miss type extruded aluminium volume control dampers at supply air outlets as per the approved shop drawings and specifications. 3 slot/2slot, powder coated extruded aluminium diffusers of approved colour & shade for return air without Hit & Miss type dampers
Supply, Installation,Testing and Balancing of flexible ducting comprising of inner as well as outer skin constructed out of aluminium & fibre glass insulation 25mm thick of minimum 16 kg/cu.m density insulation sandwitched in between. Duct should confirm to fire rating standards BS-476 part 5, 6 & 7. Flexible Ducts of following sizes as per approved shop drawings, specifications : 250 mm dia
200 mm dia
150 mm dia
100 mm dia
Supply, Installation and Testing of single piece GI round spigot made out of spinning process with 50mm height and having grooves on both sides and circular flanges. Spigots shall be installed on main ducts to facilitate connection of flexible ducts. 250 mm dia
200 mm dia
150 mm dia
100 mm dia
Supply, Installation and Testing of Butterfly damper of aluminium sheet construction with two flap with sleeve as per thespecifications and shop drawings. 100 mm dia
150 mm dia
200 mm dia
250 mm dia
Supply, Installation and Testing of GI box type volume control dampers as per the specifications and shop drawings.
Supply, Installation and Testing of Aluminium multi blade type louver dampers as per the specifications and shop drawings of approved colour & shade.
Supply, Installation,Testing and Commissioning of motorised fire dampers suitable for at least 120 minutes fire rating as per the specifications and approved shop drawings. Quoted price shall be inclusive of copper control wiring as required. Bare Fire Dampers
Spring return action type actuator complete with control panel and temperature sensor. Torque not less than 16NM
Supply, Installation and Testing of fresh air grilles of powder coated / anodised extruded aluminium with GI wire mesh, inlet louvers, Box type VCD & bird screen, as per the approved shop drawings and specifications.
Supply, Installation and Testing of Bird Screens with GI wire mesh to be installed at the suction of fresh air/discharge of Exhaust air as per the specifications and shop drawings.Sample of bird screen to be got approved from consultants and Clients prior to procurement.
Supply, Installation and Testing of non return dampers. NRDs to be installed in the ducts as per the specifications and shop drawings. Sample of NRDs to be got approved from consultants and Clients prior to procurement.
SOUND ATTENUATORS Supply , Installation & Testing of approved makes sound attenuators for supply/return air ducts of following sizes. The sound attenuators shall be suitable for minimum 18dB reduction at 250Hz octave band. Size Length Air Qty. Max. allowable Location (WxH in mm) (mm) (Cfm) pressure drop Ground Floor 1250x450 1500 6000 8mm Supply duct
1050x500 1500 6000 8mm Return duct
First Floor 1200x350 1500 4750 8mm Supply duct
1400x600 1500 9500 8mm Return duct
Second Floor Upper deck 1250x450 1500 5750 8mm Supply duct
1500x650 1500 11500 8mm Return duct
INSULATION ACOUSTIC LINING OF DUCTS Using Open Cell Nitirile Rubber with perforated aluminium foil covering Supply and Application of internal acoustic lining of supply/ return air ducting using open cell nitrile rubber insulation with density within 140-180 Kg/m3 as per the approved shop drawings and specifications. Insulation material shall be bonded with the ducts using metal screw and washers to facilitate grip to the GI sheet. 15mm thick lining
Using Fibre Glass Supply and Application of internal acoustic lining of supply/ return air ducting using resin bonded fibre glass insulation of density not less than 32Kg/CuM as per the approved shop drawings and specifications. Quoted price shall be inclusive of GSS channel, metal screws, washers, fibre glass tissue, perforated aluminium sheet of 24G etc. as required for complete installation. 25mm thick lining - For AHU Plenums/Baffles etc.
THERMAL INSULATION OF DUCTS (Using Class 'O' Fire Retardant Properties Closed Cell Elastomeric insulation with aluminium foil) Supply and Application of external thermal insulation of supply /return air ducting using closed cell elastomeric nitrile rubber insulation with class 'O' fire retardant properties and aluminum foil as per the specifications and drawings. Cladding shall provide protection from mechanical impact, and Scratches etc. Both insulation & cladding should have built in antimicrobial protection. Adhesive - AC Duct King Eco Fresh 6mm thick insulation -
9mm thick insulation - For R/A air duct in Audi Hall & S/A ducts surrounded by returm air
13mm thick insulation- For Supply Air ducts surounding by return air
16mm thick insulation - For S/A Duct in Auditorium & in Non AC Area
19mm thick insulation - For fresh air duct
25mm thick insulation - For S/A Duct where S/A & R/A both ducted
"VARIABLE REFRIGERANT VOLUME SYSTEM (HEAT PUMPS) " Supply, Installation, Testing and Commissioning of Variable Refrigerant Volume type multi unit air-conditioning system complete with indoor and outdoor units with individual controller for cooling & heating application as per the specifications and drawings. The quoted price should include clearances charges, local taxes, freight etc. VRV Shall have cut off arrangement after a particular set value of Supply air Temperature for AHUs. Quoted price shall also be inclusive of loading, unloading, lifting & shifting on Terrace or other suitable locations as per drawing, positioning charges besides including charges towards structural steel supports, MS base frame duly painted & vibration isolation arrangement etc. OUTDOOR UNITS Supply, Installation, Testing and Commissioning of air cooled variable refrigerant flow modular type cooling & heating application, each comprising of energy efficient multiple scroll compressors, full charge of R-410a refrigerant gas and all accessories as per the specifications. All compressors shall be inverter type. The condensing units shall be suitable to work on cooling as well as heating mode. The condensing units shall be suitable for operation on 415 ±10% volts, 50Hz, 3 phase AC power supply and complete with auto check function for connection error, auto address setting, etc. The outdoor units shall be low noise type. Quoted price shall be inclusive of epoxy coating (to prevent erosion of tubes & fins) of Outdoor units. The outdoor units shall be of following capacities : "VRV ODUs shall be capable of operating in follwing range : i. For Cooling : (-)5degC to 50degC ii. For Heating : (-)20degC to 15.5degC" 44HP (16HP+14HP+14HP) nominal capacity high COP outdoor unit comprising of 3 modules of requisite capacity.
40HP (20HP+20HP) nominal capacity high COP outdoor unit comprising of 2 modules of requisite capacity.
28HP (14HP+14HP) nominal capacity high COP outdoor unit comprising of 2 modules of requisite capacity.
22HP (12HP+10HP) nominal capacity high COP outdoor unit comprising of 2 modules of requisite capacity.
18HP nominal capacity high COP outdoor unit.
16HP nominal capacity high COP outdoor unit.
14HP nominal capacity high COP outdoor unit.
12HP nominal capacity high COP outdoor unit.
10HP nominal capacity high COP outdoor unit.
8HP nominal capacity high COP outdoor unit.
INDOOR UNITS Supply, Installation, Testing and Commissioning of variable refrigerant volume modular type indoor units comprising of EEV & all accessories as per the specifications. The indoor units shall be suitable to work on cooling mode. The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply except floor standing units suitable for operation on 415 ±10% volts, 50Hz, 3 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork as shown in the design drawings and dehumidified air quantity as mentioned in the heat load summary sheet under "Special Conditions" and the indoor units shall be of following capacities. All Indoor Units shall have inbuilt Drain Pumps. Quoted price shall be inclusive of Plug Top & necessary power cable. 2830Cfm Ductable Type (8.0 TR)
2290Cfm Ductable Type (6.4 TR)
1130Cfm Ductable Type (3.2 TR)
880Cfm Ductable Type (2.6 TR)
680Cfm Ductable Type (2.0 TR)
700Cfm Ductable Type (2.0 TR) - Mid Static
790Cfm Cassette Type (2.6TR) - Round Flow
700Cfm Cassette Type (2.0TR) - Round Flow
610Cfm Cassette Type (1.6TR) - Round Flow
530Cfm Cassette Type (1.3TR) - Round Flow
CASSETTE PANELS Supply, Installation, Testing and Commissioning of decorative panels for cassette type indoor units.
REMOTE CONTROLS Supply of Cordless handset type remote controls for the above indoor units.
Supply, Installation, Testing and Commissioning of Corded remote controls for the above indoor units.
CENTRALISED CONTROLLER Supply, Installation, Testing and Commissioning of main Intelligent Touch Manager with plus adapter type centralised controller as per specifications to hook up indoor units as mentioned above. Controller shall however be suitable for minimum 48 groups of indoor units. Centralised controller shall act as master controller for controlling of outdoor units and their associated indoor units. Controller shall be suitable of Remote Access with computer and shall have web access. Controller shall be suitable to configured the inside temperature as per temperature set point on controller. Controller shall have time schedulling arrangement & temperature setting for Indoor Units as well as Outdoor Units. Quoted price shall be inclusive of all necessary cabling as required from ODU & IDUs to controller & other accessories as required to make the system proper fucntional.
FITTINGS Supply, Installation,Testing & Commissioning of following imported copper fittings to be provided in refrigerant pipe line. Refnet Joints (Y- Joints)
"VRV SYSTEM FOR UPS ROOM VARIABLE REFRIGERANT VOLUME SYSTEM" (HEAT PUMP) Supply, Installation, Testing and Commissioning of Variable Refrigerant Volume type multi unit air-conditioning system complete with indoor and outdoor units with individual controller for cooling & heating application as per the specifications and drawings. The quoted price should include clearances charges, local taxes, freight etc. Quoted price shall also be inclusive of loading, unloading, lifting & shifting on Terrace or other suitable locations as per drawing, positioning charges besides including charges towards structural steel supports, MS base frame duly painted & vibration isolation arrangement etc. OUTDOOR UNITS Supply, Installation,Testing and Commissioning of air cooled variable refrigerant flow modular type cooling application, each comprising of energy efficient multiple scroll compressors, full charge of R-410a refrigerant gas and all accessories as per the specifications. All compressors shall be inverter type. The condensing units shall be suitable to work on cooling as well as heating mode. The condensing units shall be suitable for operation on 415 ±10% volts, 50Hz, 3 phase AC power supply and complete with auto check function for connection error, auto address setting, etc. The outdoor units shall be low noise type. Quoted price shall be inclusive of Power Cable from MCCB to Outdoor unit & MS frame duly applied with 2 coat of primer & one coat of black enamel paint. Quoted price shall be inclusive of epoxy coating (to prevent erosion of tubes & fins) of Outdoor units. The outdoor units shall be of following capacities : "VRV ODUs shall be capable of operating in follwing range : i. For Cooling : (-)5degC to 50degC ii. For Heating : (-)20degC to 15.5degC" 10HP nominal capacity high COP outdoor unit.
INDOOR UNITS Supply, Installation, Testing and Commissioning of variable refrigerant volume modular type indoor units comprising of EEV & all accessories as per the specifications. The indoor units shall be suitable to work on cooling mode. The indoor units shall be suitable for operation on 220 ±6% volts, 50Hz, 1 phase AC power supply except floor standing units suitable for operation on 415 ±10% volts, 50Hz, 3 phase AC power supply. Ductable indoor units shall be suitable to handle extent of ductwork as shown in the design drawings and dehumidified air quantity as mentioned in the heat load summary sheet under "Special Conditions" and the indoor units shall be of following capacities. All Indoor Units shall have inbuilt Drain Pumps. Quoted price shall be inclusive of Plug Top & necessary power cable. 670Cfm Wall Mounted Type (2.0TR)
REMOTE CONTROLS Supply of Cordless handset type remote controls for the above indoor units.
CENTRALISED CONTROLLER Supply, Installation, Testing and Commissioning of main Intelligent Touch Manager with plus adapter as per specifications to hook up indoor units as mentioned above. Controller shall however, be suitable for minimum 64 groups of indoor units.Centralised controller shall act as master controller for controlling of cooling mode of outdoor units and their associated indoor units. Controller shall be suitable of Remote Access with computer and shall have web access. Controller shall be suitable to autosequence the outdoor as well as indoor units catering to 24x7 operated areas as required/mentioned under sub head "System Design" of tender document. Controller shall be suitable to configured the inside temperature as per temperature set point on controller. Controller shall have time schedulling arrangement for Indoor Units as well as Outdoor Units. Controller shall be BMS Compatible & suitable for BMS integration. Quoted price shall be inclusive of all necessary cabling as required from ODU & IDUs to controller.
DRAIN PUMP Supply, Installation, Testing & Commissioning of Condensate Drain Pump with adequate Sump for Hi-wall units complete with water level sensor and accessories as required. Quoted price shall be inclusive of controller, NRVs & water sensors and associated wiring etc. to make installation complete. Drain Pump shall be suitable for operation on 220+6 % volts 50 Hz, 1phase AC power supply. Drain pumps shall automatically ON/Off based on water level. Drain pump for Hi-wall units Drain pump for Hi-wall units
COPPER REFRIGERANT PIPING Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications.MS sleeves of requisite size shall be provided at wall crossing. Quoted price shall be inclusive of necessary glass cloth and minimum two layers of UV protection paint to be applied over insulation for all exposed pipes of approved make. Piping shall be of following sizes : Internal Refrigerant piping in exposed ceiling area & external refrigerant piping shall be laid on Ladder type cable trays. Cable trey used for external refrigerant piping shall be covered with cover. Pipe Size Thickness of CSE (O.D.) Insulation 22.2 mm 19 mm
FITTINGS Supply, Installation,Testing & Commissioning of following imported copper fittings to be provided in refrigerant pipe line. Refnet Joints (Y- Joints)
CONDENSATE DRAIN PIPING-GI Supply, Installation , Testing and Commissioning of GI medium class (Class 'B') pipes cut to requird lengths and installed with all screwed joints for condensate drain. Quoted price shall be inclusive of supply and fixing in position the necessary fittings like elbows, tees reducers etc. and supporting arrangement in accordance with the approved shop drawings and specifications. Pipes shall be insulated with 9mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form . Pipes shall be of following sizes : 32mm dia
25mm dia
CONDENSATE DRAIN PIPING -cPVC Supply, Installation, Testing and Commissioning of cPVC pipes cut to required lengths and installed for condensate drain. Quoted price shall be inclusive of supply and fixing in position the necessary fittings like elbows, tees reducers etc. and supporting arrangement in accordance with the approved shop drawings and specifications. Pipes shall be insulated with 9mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form . Pipes shall be of following sizes : 40mm dia
32mm dia
25mm dia
TUBE AXIAL FANS Supply, Installation, Testing and Commissioning of axial flow fans (tube axial type) complete with MS casing, impeller, flame proof motor with class 'F" insulation for make - up air system and class "H" insulation for normal and smoke evacuation of basement as shown in the drawings and as per the specifications. Fans with class "H" motors should be suitable for operating for mimimum 2 Hrs at 250-300 degC temp. Axial fans shall be suitable for operation on 415±10% volts, 50Hz, 3 phase AC power supply. Axial flow fans shall be provided with necessary vibration isolation arrangement including spring type vibration isolators and rubber groumet etc. as required. Fans shall be IP-55 rated. All fans should be AMCA certified. Motor shall be IE-2 type. Fan Capacity S.P Motor Area being Fan No. (Cfm) (mmWG) Rating/Class fed Dia/RPM (HP) (mm) Smoke Evacuation TAF-1 6300 26-28 3.0 Audi-1 at GF 630/1450 Class'H' Smoke Exhaust
TAF-2 6300 26-28 3.0 Audi-1 at GF 630/1450 Class'F' Make up air
TAF-3 3000 26-28 2.0 Restaurant at GF 450/2850 Class'H' Smoke Exhaust
TAF-4 3000 26-28 2.0 Restaurant at GF 450/2850 Class'F' Make up air
TAF-5&6 5000 28-30 3.0 Lobby/ Passage at GF 630/1450 Class'H' Smoke Exhaust
TAF-7 12000 28-30 7.5 Audi-2 at 1F 800/1450 Class'H' Smoke Exhaust
TAF-8 12000 28-30 7.5 Audi-2 at 1F 800/1450 Class'F' Make up air
TAF-9&10 5000 28-30 3.0 Lobby/ Passage at 1F 30/1450 Class'H' Smoke Exhaust
TAF-11&12 5200 28-30 3.0 Lobby/ Passage at 2F 630/1450 Class'H' Smoke Exhaust
TAF-13&14 16500 28-30 10 Audi-3 at 2Upper F 800/1450 Class'H' Smoke Exhaust
TAF-15&16 16500 28-30 10 Audi-3 at 2Upper F 800/1450 Class'F' Make up air
TAF-17 6500 28-30 5.0 Lobby/ Passage at 1F 630/1450 Class'H' Smoke Exhaust
TAF-18to20 8500 28-30 5.0 Lift wells 710/1450 Class'F' Pressurization
900mm to 1500mm -- 22G GSS with TDC Joints
1501mm to 2100mm - 20G GSS with TDC Joints
2101mm to 2700mm - 18G GSS with TDC Joints
SITE FABRICATED DUCTING Supply, Fabrication, Installation and Testing of sheet metal ducts complete with vanes, splitter dampers, hanging arrangement including check nuts in accordance with the approved shop drawings and specifications a. 0.63mm (24 gauge) GSS
b. 0.8 mm (22 gauge) GSS
FLEXIBLE CANVASS CONNECTIONS Supply, Installation , Testing of 125mm deep antivibration flexible joints at the outlet of packaged units/inline fans. Flexible connections shall be constructed using imported fire retardant fabric with extruded aluminium frame/flange on both sides of approved make.
Supply, Installation and Testing of multiblade box type zero leakage extruded aluminium dampers for ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per the approved shop drawing and specifications.
Supply and fixing of actuators of suitable rating of torque complete with copper wiring from the junction box and actuator associated with the above VCDs. Actuator shall be suitable for duct size as shown in the drawing.
Supply, Installation and Testing of Bird Screens with GI wire mesh to be installed at the suction of fresh air/discharge of Exhaust air as per the specifications and shop drawings. Sample of bird screen to be got approved from consultants and Clients prior to procurement.
ACOUSTIC LINING OF AHU ROOMS Using Fibre Glass Supply and Application of acoustic/ thermal lining of walls/ ceiling of AHU rooms using resin bonded fibre glass insulation of density not less than 32Kg/CuM as per the approved shop drawings and specifications. Quoted price shall be inclusive of GSS channel, metal screws, washers, fibre glass tissue, perforated aluminium sheet of 24G etc. as required for complete installation. 50mm thick lining
Supply and Application of acoustic/ thermal lining of walls/ ceiling of AHU rooms using resin bonded fibre glass insulation of density not less than 32Kg/CuM as per the approved shop drawings and specifications. Quoted price shall be inclusive of GSS channel, metal screws, washers, fibre glass tissue, perforated aluminium sheet of 24G etc. as required for complete installation. 75mm thick lining
UNDERDECK INSULATION Shifting & Application of 50mm thick TF quality expanded polystyrene (EPS) insulation for ceiling/exposed roof towards underdeck insulation. Thermocole insulation to be fixed with 5 GI screws & GI washers in grid of 1 m x 1m to the underside of the slab. All four corners & center screw will be tied with G.I binding wires. Quoted price shall be inclusive of Low VOC adhesive as required and as per the specifications. Density of insulation shall not be less than 24Kg/CuM.
Supply and Application of 19mm thick Class 'O' closed cell nitrile rubber elastomeric insulation exposed roof towards underdeck insulation. Quoted price shall be inclusive of Low VOC adhesive as required and as per the specifications. Metal screws shall be fixed with dash fasteners at centre & Corners of each piece of insulation with a GI cleat at bottom to give extra precaution in fixing of insulation. Adhesive based tapes shall be applied on all longitudinal and transverse joints.
ACOUSTIC TREATMENT & FURNISHING (F) AUDITORIUM - ACOUSTIC TREATMENT / AV / FURNISHING Cost of Auditorium Acoustic Ceiling : Armstrong Mineral fibre Acoustical suspended ceiling system with optra FG (board / tegular) edge tiles with armstrong XL 24mm exposed grid 600x600x15)mm
For Auditorium Wall Acoustic upto 2.10 m : Corded Fabric wrapped Acoustical wood wool board (1200mm x 600) x 20mm thick of 400kg /cum density fixed over a framework of GI frame from 2.10 m height above floor level to ceiling level. (Make : Himalayan Acoustics, Fibercrete, Hera Design).
For Auditorium Acoustic above 2.10 m height to ceiling Lvel : 1.5mm thick Laminate with 12mm thick waterproof termite resistant ply panels secured over GI frame consisting Of 50mm th. GI Stud wall channels & floor channels with filling of 50 mm th. fibreglass resin bonded insulation of density 32kg/cum with covering of GI netting. (Plywood: Greenply, Mayur, Century; Laminate: Greenlam, Century).
Cost of wooden Porscenium in front of stage including framing and all fixtures.
Cost of Theatre Acoustic Doors : Accoustic Doors made using 100mm thick hard wood hollow framing filled with 24Kg / M3 desnity fibre glass wool, fixed with 8mm water proof ply wood on both sides, finally pasted with teak vineer on both sides duly polished.
Supply and installation of 100mm thick underdeck insulation made out of 48kg/m3x 50mmx 2 layers of fibre glass wool below metal roof with a covering of 12.5/13 mm gypsum plaster boardof size 1200X1800mm
Cost of Stage Floor area Framing : Sal wood plank of 38 mm thick, joined anf fitted on sal wood joist of size 100mm x 125mm, spaced not more than 900mm apart fitted with 16mm dia bolt and nuts.
Auditorium Acoustic Floor : PUR Vinyl Sheet flooring manufactured by Armstrong World Industries, having a nominal thickness of 2mm, width 1.83m. The nominal thickness of the wear layer should be 2mm. The wear surface shall consists of homogeneous mixure of PVC, Polyurethane, Plasticisers, Urethane, colour pigments and filler calendered to form a sheet.
Carpet flooring for Auditorium - (melliken or armstrong make)
Cost of Auditorium : Led Foot Lights with Seat Nos & Directions including neceaasry wiring on the floor complete in all respect as directed by the consultant.
FURNITURES & FIXTURES : Installation of Auditorium - 21" C/C push back tip up chairs - makes : Theatre solution, earcon or equivalent.
Cost of Furnitures for canteen, staff Offices, Green rooms, Pantry, Guest rooms etc. (considering 60% coverage by furnitures)
PASSENGER ELEVATOR Supply, Installation, Testing & Commissioning of Passenger Elevators with automatic door 13 Passenger capacity
Supply, Installation, Testing & Commissioning of Passenger Elevators with automatic door 20 Passenger capacity
VERSHA TECHNOTRADE PVT LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.65 MB
SBD.pdf
Tender Documents • 2.61 MB
FOB.pdf
Additional Documents • 0.10 MB
BOQ_31590.xls
BOQ • 0.73 MB
Download all tender documents and submit your bid