| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹37.5 L+₹27,466 (0.74%)Rejected-AOC 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹37.6 L+₹33,896 (0.91%)Rejected-AOC 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹39.4 L+₹2.2 L (5.85%)Rejected-AOC | L4 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
24 Sept 2022, 6:00 pmClosed
GE SOUTH PUNE
NO. 1 GENERAL BHAGAT MARG PUNE 411040
8365 MAINTENANCE / REPAIRS TO UPS, BATTERY, OT LIGHT, STREET LIGHT FITTINGS, FLOOD LIGHT FITTING, PANELS, EARTHING AND MISC WORKS AT NEW COMMAND HOSPITAL WITH CONNECTED MD / OTM ACCN AREA UNDER GE SOUTH PUNE
2022_MES_546839_1
8365 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹96,000
12 Nov 2022
22 Aug 2022
26 Sept 2022
22 Aug 2022
24 Sept 2022
12 Sept 2022
Amount
Attending urgent complaints of UPS 160 KVA of Schneider electric (APC) microprocessor controlled -03 Nos, 100 KVA- 02 Nos and 60 KVA-02 Nos with isolation transformer dedicated for each UPS as per capacity installed at LGF of main building / Civ OPD of new CH(SC) on call basis immediately by OEM ONLY, issues may be due to faults in various distribution box / LT panel / copper & aluminium cable/ finding of fault of UPS supply upto OT/ICU/Medical Eqpt or where ever UPS supply has been provided, UPS Battery discharge, various switchgear fault, overload, short cct, earth fault, neutral fault, over heating, high voltage or any other fault to be rectified immediately by OEM including replacement of defective & worn out parts by new spares as directed by engineer-in Charge. (Note : - 1. Spares will be measured and paid separately 2. Room temparature of UPS room to be maintained strictly without fail)
Attending urgent complaints of Operation Theatre Shadowless type Lights provided in all OTs room for direct /reflection free illumination of new CH with dual control panel and two domes LED light with various capacity of Make - Dr Mach including replacement of accessories of OT lights. Fault may be due to various switchgear defect, overload, short cct, earth fault, neutral fault, over heating, high voltage or any other fault to be rectified immediately by OEM of respective make as per site including replacement of defective & worn out parts by new spares as directed by engineer-in Charge. (Note : - Spares will be measured and paid separately )
Attending day to day complaints of street light / flood light of any make/type/ capacity and repairing for proper functioning including replacing small parts. One electrician to be present daily during the contract period for attending the complaints of street light / flood light / Cable fault of any size & type / earth leakage/ short circuit / neutral break mains / substations / internal circuits of existing system of main building / block, making continuous electric supply including carrying out minor repairs etc as required to make the system in order / functional including replacing fuse wire, copper cable, copper thimbles, glands, earthing wire, cable jointing complete all as specified and directed.
[Note for Ser. Item No. 03.00 above : (i) Rate of Fuse wire, copper cable, copper thimbles, glands, earthing wire are deemed to be considered in this item (ii) Zone-1 and Zone-2 area of new CH(SC) as well as residential accn under GE(South) Pune AOR as directed by Engr in Charge. One electrician to be present daily round the clock or any emergent complaints assigned for complete period of contract. (iii) Contractor will provide ladder for attending complaints of street light / flood light at any height without any extra cost in this respect. (iv) Necessary insurance coverage should be taken for their all staff by the bidder before commencement of the works. (v) All rates for the above are deemed to be included in Sch 'A'(BOQ) items (vi) Attending two number of complains shall be measured as one job.]
Preventive Maintenance of UPS 160 KVA of Schenider electric (APC) make microprocessor controlled with isolation transformer installed at LGF of main building/ Civ OPD of new CH(SC) by OEM ONLY by disconnecting main supply and opening the top / side cover/ dust filter of the UPS as well as isolation transformer by opening nut & bolts, removing auxillary control cables/power cables, fans, capacitors, cleaning of each and every hard ware items of the UPS/Isolation transformer by using high speed air blower like cooling fans, mother board, capacitors, transformer, IGBT, PCB cards, battery etc for healthy functioning of UPS including replacement of defective & worn out parts by new spares and testing after complete servicing as directed by engineer-in Charge. (Note : - 1. Spares will be measured and paid separately 2. Room temparature of UPS room to be maintained strictly without fail)
Preventive Maintenance of UPS 100 KVA of Schenider electric (APC) make microprocessor controlled with isolation transformer installed at LGF of main building/ Civ OPD of new CH(SC) by OEM ONLY by disconnecting main supply and opening the top / side cover/ dust filter of the UPS as well as isolation transformer by opening nut & bolts, removing auxillary control cables/power cables, fans, capacitors, cleaning of each and every hard ware items of the UPS/Isolation transformer by using high speed air blower like cooling fans, mother board, capacitors, transformer, IGBT, PCB cards, battery etc for healthy functioning of UPS including replacement of defective & worn out parts by new spares and testing after complete servicing as directed by engineer-in Charge. (Note : - 1. Spares will be measured and paid separately 2. Room temparature of UPS room to be maintained strictly without fail)
Preventive Maintenance of UPS 60 KVA of Schneider electric (APC) make microprocessor controlled with isolation transformer installed at LGF of main building/ Civ OPD of new CH(SC) by OEM ONLY by disconnecting main supply and opening the top / side cover/ dust filter of the UPS as well as isolation transformer by opening nut & bolts, removing auxillary control cables/power cables, fans, capacitors, cleaning of each and every hard ware items of the UPS/Isolation transformer by using high speed air blower like cooling fans, mother board, capacitors, transformer, IGBT, PCB cards, battery etc for healthy functioning of UPS including replacement of defective & worn out parts by new spares and testing after complete servicing as directed. (Note : - 1. Spares will be measured and paid separately 2. Room temparature of UPS room to be maintained strictly without fail)
S&F in repair Integral LED Street Light Luminaire 25 W comprising of epoxy powder coated pressure die cast aluminium housing, including GI Pipe 1.2 mtr long and 40 mm or suitable for new fitting complete with accessories conforming to make Cat Part No Halonix-HLSLD-14-25-CWDL-R01 or of equivalent in Bajaj/ Havells/Philips/HPL all as specified here-in-after.
S&F in repair Integral LED Street Light Luminaire 30 W comprising of epoxy powder coated pressure die cast aluminium housing, including GI Pipe 1.2 mtr long and 40 mm or suitable for new fitting complete with accessories conforming to make Cat Part No Halonix-HLSLD-14-30-CWDL-R01 or of equivalent in Bajaj/ Havells/Philips/HPL all as specified here-in-after.
S&F in repair Integral LED Street Light Luminaire 36 W comprising of epoxy powder coated pressure die cast aluminium housing, including GI Pipe 1.2 mtr long and 40 mm or suitable for new fitting complete with accessories conforming to make Cat Part No Halonix-HLSLD-14-36-CWDL-R01 or of equivalent in Bajaj/ Havells/Philips/HPL all as specified here-in-after.
S&F in repair Integral LED Street Light Luminaire 60 W comprising of epoxy powder coated pressure die cast aluminium housing, including GI Pipe 1.2 mtr long and including 40 mm or suitable for new fitting complete with accessories conforming to make Cat Part No Halonix-HLSLD-14-60-CWDL-R01 or of equivalent in Bajaj/ Havells/Philips/HPL all as specified here-in-after.
S&F in repair Integral LED Street Light Luminaire 70 W comprising of epoxy powder coated pressure die cast aluminium housing, including GI Pipe 1.2 mtr long and 40 mm or suitable for new fitting size complete with accessories conforming. Make Cat Part No Halonix-HLSLD-01-70-CWDL-R01 or of equivalent in Bajaj/ Havells/Philips/HPL all as specified here-in-after.
S&F in repair Integral LED Street Light Luminaire 90 W comprising of epoxy powder coated pressure die cast aluminium housing, including GI Pipe 1.2 mtr long and including 40 mm or suitable for new fitting complete with accessories conforming to make Cat Part No Halonix-HLSLD-15-90-CWDL-R01 or of equivalent in Bajaj/ Havells/Philips/HPL all as specified here-in-after.
S&F in repair Integral LED Street Light Luminaire 120 W comprising of epoxy powder coated pressure die cast aluminium housing, including GI Pipe 1.2 mtr long and including 40 mm or suitable for new fitting complete with accessories conforming to make Cat Part No Halonix-HLSLD-01-120-CWDL-R or of equivalent in Bajaj/ Havells/Philips/HPL all as specified here-in-after.
S&F in repair Integral LED Street Light Luminaire 150 W comprising of epoxy powder coated pressure die cast aluminium housing, including GI Pipe 1.2 mtr long and including 40 mm or suitable for new fitting complete with accessories conforming to make Cat Part No Halonix-HLSLD-06-150-CWL-R or of equivalent in Bajaj/ Havells/Philips/HPL all as specified here-in-after.
S&F in repair LED flood lights fitting 40 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system conforming to Halonix CAT Part No HLFLD-ML27-40-CW-R01 or equivalent in Bajaj/ Havells / WIPRO / HPL
S&F in repair LED flood lights fitting 60 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-60-CW-R01 or equivalent in Bajaj/ Havells/WIPRO/HPL
S&F in repair LED flood lights fitting 70 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-70-CW-R01 or equivalent in Bajaj/ Havells/WIPRO/HPL
S&F in repair LED flood lights fitting 100 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-100-CW-R01 or equivalent in Bajaj/ Havells/WIPRO/HPL
S&F in repair LED flood lights fitting 150 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-150-CW-R01 or equivalent in Bajaj/ Havells/WIPRO/HPL
S&F in repair LED flood lights fitting 200 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-200-CW-R01 or equivalent in Bajaj/ Havells/WIPRO/HPL
S&F in repair LED flood lights fitting 250 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system. Halonix CAT Part No HLFLD-ML27-250-CW-R01 or equivalent in Bajaj/ Havells/WIPRO/HPL
S&F In repair driver suitable for LED street light/flood light fitting of 25 to 36 wattage Wipro CAT Part No LPV-35-12/24 or equivalent in Bajaj/ Havells/ Halonix / HPL complete all as directed by Engineer-in-Charge.
S&F In repair driver suitable for LED street light/flood light fitting of 50 to 60 wattage Wipro CAT Part No LPV-60-12/24 or equivalent in Bajaj/ Havells/ Halonix/ HPL complete all as directed by Engineer-in-Charge
S&F In repair driver suitable for LED street light/flood light fitting of 70 to 75 wattage Wipro CAT Part No ELG-75-24/48 or equivalent in Bajaj/ Havells/ Halonix/HPL complete all as directed by Engineer-in-Charge
S&F In repair driver suitable for LED street light/flood light fitting of 90 to 100 wattage Wipro CAT Part No ELG-100-24/48 or equivalent in Bajaj/ Havells/Halonix/HPL complete all as directed by Engineer-in-Charge
S&F In repair driver suitable for LED street light/flood light fitting of 120 to 150 wattage Wipro CAT Part No ELG-150-24/48 or equivalent in Bajaj/ Havells/Halonix/HPL complete all as directed by Engineer-in-Charge
S&F In repair driver suitable for LED street light/flood light fitting of 200 wattage Wipro CAT Part No ELG-200-24/48 or equivalent in Bajaj/ Havells/Halonix/HPL complete all as directed by Engineer-in-Charge
S&F In repair driver suitable for LED street light/flood light fitting of 250 wattage Wipro CAT Part No ELG-240-24/48 or equivalent in Bajaj/ Havells/Halonix/HPL complete all as directed by Engineer-in-Charge
Supply and errect in true vertical position steel tubular swaged pole swan neck type single arm 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, including painting with anti corrosive black bituminous paint internally complete and externally up to planting depth and exposed portion with Aluminium paint two coats over a coat of red oxide primer including taking down unsv/ damaged pole all as directed by Engr-in-charge. (Note : Excavation and earth work, PCC for foundation and coping shall be measured paid seperately under respective item of this schedule.)
Supply and fix in repair Power Supply unit for OT Light of Dr. Mach ( LED 3 SC) and testing for its funtional state and producing test certificate for the same complete all as directed by Engr-in-charge.Make- Dr. Mach or equivalent.
Supply and fix in repair Display unit for OT Light of Dr. Mach ( LED 3 SC) and testing for its funtional state and producing test certificate for the same complete all as directed by Engr-in-charge.Make- Dr. Mach or equivalent.
Supply and fix in repair Sterilizable handle for OT Light of Dr. Mach (LED 3 SC) and testing for its funtional state complete all as directed by Engr-in-charge.Make- Dr. Mach or equivalent.
Supply and fix in repair Cluster board for OT Light of Dr. Mach (LED 3 SC) and testing for its funtional state complete all as directed by Engr-in-charge.Make- Dr. Mach or equivalent.
Supply, lay, test connecting and commissioning UG cable LT 1100 volt grade heavy duty XLPE insulated armoured with copper stranded conductor complete laid in trenches/fixed to poles /drawn through pipes with suitable size cable glands criping type cable lugs etc all as specified and directed of size 150 Sqmm 1 Core,including takind down old unserviceable cable.
All as per Ser. Item No. 34.00 above but 70 sq mm 1 core complete all as specified and as directed.
All as per Ser. Item No. 34.00 above but 35 sq mm 1 core complete all as specified and as directed.
All as per Ser. Item No. 34.00 above but 25 sq mm 4 core complete all as specified and as directed.
All as per Ser. Item No. 34.00 above but 16 sq mm 4 core complete all as specified and as directed.
All as per Ser. Item No. 34.00 above but 10 sq mm 4 core complete all as specified and as directed.
All as per Ser. Item No. 34.00 above but 10 sq mm 2 core complete all as specified and as directed.
All as per Ser. Item No. 34.00 above but 6 sq mm 2 core complete all as specified and as directed.
Supply, laying, testing and commissionnig of LT cable of size 35 Sqmm 3.5 core laid in trenches/fixed to poles/drawn through pipes of 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc complete
All as per Ser. Item No. 42.00 above but 25 sq mm 3.5 core complete all as directed
All as per Ser. Item No. 42.00 above but 16 sq mm 4 core complete all as directed
All as per Ser. Item No. 42.00 above but 10 sq mm 2 core complete all as directed
All as per Ser. Item No. 42.00 above but 6 sq mm 2 core complete all as directed
Supply and fix junction boxes out door type weather proof with fixing accessories made out of moulded PVC size 250x200x80 mm to be fixed at the height of 1 M from bottom of street light pole complete with wiring, arrangement for MS Clamp, cable entery/exit, 01 No. MCB SP 6 Amps, 4 pole connector for fixing cable etccomplete all as specified and directed by Engr-in-charge.
M&L for bringing Cable testing van (Fault Finder) for detecting the location of fault in the LT UG cable 1.1 KV of any size complete all as specified and as directed
S & F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 70 to 150 Sqmm single core copper cable including all accessories required. [Make :- Denson/M Seal/Siemens.]
S & F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 10 to 25 Sqmm four core copper cable including all accessories required. [Make :- Denson/M Seal/Siemens.]
S & F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 6 to 10 Sqmm two core copper cable including all accessories required. [Make :- Denson/M Seal/Siemens.]
S & F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 16 to 35 Sqmm 3.5/4 core aluminium cable including all accessories required. [Make :- Denson/M Seal/Siemens.]
S & F in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 6 to 10 Sqmm 2 core aluminium cable including all accessories required. [Make :- Denson/M Seal/Siemens.]
M&L for plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations of poles complete all as specified and directed by Engr-in-charge
M&L for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping, bed block etc including necessary form work complete all as specified and directed by Engr-in-charge
M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate etc including necessary form work complete all as specified and directed by Engr-in-charge
S&F in repair PVC insulated sheathed wire with copper conductor flexible 2 core 2.5 sqmm with one core 1.5 sq mm earth wire PVC insulated fixed to FRP junction box of street light fitting with suitable clamp as required for 8.5/9 mtr long pole for fixing to existing pole and conduit including suitable size of lugs for looping all as specified and directed by Engineer-in-Charge.
S&F in repair on wall/ceiling/panel single core flexible copper conductor PVC insulated cable 4 sqmm, 1100 volt confirming to IS : 694 connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material including taking down unsv cable of any type all as specified and directed.
S&F in repair on wall/ceiling/panel single core flexible copper conductor PVC insulated cable 6 sqmm, 1100 volt confirming to IS : 694 connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material including taking down unsv cable of any type all as specified and directed.
S&F in repair on wall/ceiling/panel single core flexible copper conductor PVC insulated cable 10 sqmm, 1100 volt confirming to IS : 694 connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material including taking down unsv cable of any type all as specified and directed.
S&F in repair on wall/ceiling/panel single core flexible copper conductor PVC insulated and cable 16 sq mm , 1100 volt confirming to IS : 694 connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material including taking down unsv cable of any type all as specified and directed.
M&L for Reinforced concrete pipes, class NP2 with one collar per lengh of pipe of dia 100 mm, half round (02 Nos for top & bottom) complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 m in depth for foundation and getting out in Soft /Loose Soil complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and not exc 1.5 m in depth for foundation and getting out in Hard/Dense soil complete all as specified and as directed.
Returning filling in incluiding spreading levelling watering and well ramming in layers not exc 25 mm complete all as specified and as directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
Taking down carefully defective street light fitting 70/150/250/ 400W any type from pole/bldg for repairs and refixing the same after replacing defective accessories with new accessories of any type & PVC insulated sheathed copper conductor cable of existing size complete to entire satisfaction of Engr-in-Charge.
M&L Cutting of branches of tree of various length to keep a clear distance 2 mtr from the Street light pole and remaining the cut branches upto a distance of 50 mtr away from the LT/HT/ overhead line/ Transformer complete all as spd and directed by engrs in charge. (Note :- Each span between pole to pole shall be measured one job)
M&L for earthing complete with GI earth plate electrode of size 60cmx60cmx6.3mm thick burried directly in ground to a depth not less than 2.25 m and top edge of the plate not less than 1.5 mtr below normal ground level including connecting GI earth strip 32x6 mm by GI nut, bolt, washers all as shown in electrical plate No. 3 of SSR Part I of 2009 including funnel for watering, PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in pit / chamber, RCC 1:2:4 type B0 using 12.5mm graded stone aggregates and 6mm dia mild steel bats at 100mm c/c as in chamber cover, charcoal, salt, MS funnel etc complete including excavation and earth work in any strata, test point and testing on completion including filling up the earth pit with black cotton soil for best result and removal of excavated material from site all as specified and directed by Engineer-in-charge. (Note : Rate is inclusive of GI strip upto 7.5mtr length and beyond 7.5 mtr shall be measured and paid separately).
M&L for galvanised iron strip of size 32 x 6mm earth continuity conductor on wall / floor and connected to equipment including nut & bolt of suitable size complete all as specified and as directed.
Supply and fixing Bracket for Pole Flood Light Fitting round shape suitable for four to six flood light fitting mounted at any height or as per site requirement, made of iron rod of suitable size as per existing shape complete all as specified & directed by Engr-In-Charge.
Supply and Fix in replacement of MCCB 63 Amps to 100 Amps, 16 KA, 3 Pole, 415V complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement of MCCB 125 Amps,16 KA,3 Pole,415Vcomplete all as specified and directed by Engr-in-Charge
Supply and Fix in replacement of MCCB 200 Amps,25 KA,3 Pole,415Vcomplete all as specified and directed by Engr-in-Charge.
Supply only 11 KV grade EN- 13319-2000 Rubber insulating seamless rubber Hand safety gloves Item Part No- JG of Jyot manufacturer or equivalent make complete all as specified and directed by Engr-in-Charge.
Supply only 22 KV grade insulating seamless natural latex rubber Hand safety gloves Item Part No- 33kv jyot of Jyot manufacturer or equivalent make complete all as specified and directed by Engr-in-Charge.
S&F LED Fantasy Bollard LB14 of 11 Watt IP 65 protection,corrosion resistance better optics for uniform distribution all as specified and directed by Engn-in-charge. (Make :- WIPRO cat part No. LB14-131-XXX-65-05 or equivalent in Crompton/Bjajaj/ HPL/Halonix.)
Supply and Fix LED post top lantern 35 to 45 watts including taking down existing any type of fitting complete all as specified and as directed. [Make - WIPRO cat part No. LP07-431-XXX-57-CL or equivalent in Crompton/Bjajaj/ HPL/Halonix.]
S&F in replacement MCB SP 6-32 Amps,10KA,'C' series complete all as specified and as directed.
S&F in replacement MCB SPN 20-40 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
S&F in repair, IP-43, MCB DB 8 way, double door, with 100 amp rated busbar 240 V, SPN concealed / surface on wall as directed by Engr in charge including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing completer all as specified and as directed.
Supply and fixing in repairs PVC fresh air fan 250mm sweep complete all as specified and as directed.
M&L for Mild steel chequered plate 5 mm thick Fe-410 W (Gde-E-250) quality B complete all as directed and specified.
Supply and fix MCB TP 63 Amps, 415 volts complete all as specified and as directed
Supply and fix MCB TP 40 Amps, 415 volts complete all as specified and as directed
M&L for single pointed air termination aluminium rod, 12 mm dia, 300 mm long and tightening with screws complete all as specified and as directed
M&L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75X75X25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and as directed.
S & F in replacement of 12 volt 100 AH SMF battery complete as directed by Engineer-in-charge
S & F in replacement of 12 volt 150 AH SMF battery complete as directed by Engineer-in-charge
Design, supply,install, test and comissioning of free standing floor mounted, dust and vermin proof Panel of suitable size for out door installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted with epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 600, Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkable sleeves, with 600 mm depth of the panel. The panel shall be modular/cubical trype with bus chamber cable allyand provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door, front and rear openable with locking arrangement and suitable for 1100 Volts grade, 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 .
Ser. Item No. 91.00 Contd... The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc INCOMING :- (a) MCCB 4 pole 400 Amps capacity rup cap 36 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No incoming OUTGOING :- (a) MCCB 4 pole 250 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release typewith rotary handle - 02 Nos Out going (b) MCCB 4 pole125 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going (c) MCCB 3 pole 63 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going (d) LT Danger notice plate -01 No (e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables
RELIABLE ENTERPRISES
A K ENTERPRISES
SUNIT TRADING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .