Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAccepted-AOC | ₹5.0 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹5.5 Cr+₹50.1 L (10.1%)Rejected-AOC | ₹5.5 Cr+₹50.1 L (10.1%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹5.6 Cr+₹64.1 L (12.9%)Rejected-AOC 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | ₹5.6 Cr+₹64.1 L (12.9%) | L3 | Rejected-AOC NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹4.6 L
Closing Date
29 Nov 2024, 6:00 pmClosed
COL MANOJ NEGI
CWE AF NORTH BANGALORE BELLARY ROAD JC NAGAR POST BANGALORE 560006
PROVISION OF PERMANENT BUILDING FOR URC AND ASSOCIATED FACILITIES AT HQTC BANGALORE
2024_MES_654172_3
87434CWEAFNBAN
Open Tender
Civil Works
Lump-sum
540 days
GE (AF) BANGALORE
AS PER NIT
7 documents required · 7 mandatory
₹2,000
GE (AF) BANGALORE
₹4.6 L
Yes
20 Jan 2025
28 Oct 2024
2 Dec 2024
29 Oct 2024
29 Nov 2024
15 Nov 2024
29 Oct 2024 - 6 Nov 2024
Amount
BOQ Dated
GENERAL SUMMARY NOTE : Schedule 'A' Part I to XVI are prepriced by MES under Ser No. 2 to 17. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by Contractor for "BUILDING WORKS" as listed in Schedule Á' Part I
Lumpsum price worked out by Contractor for "COMPOUND WALL" as listed in Schedule Á' Part II
Lumpsum price worked out by Contractor for "FENCING AND GATE" as listed in Schedule Á' Part III.
Lumpsum price worked out by Contractor for "INTERNAL ELECTRIC SUPPLY AND AC" as listed in Schedule Á' Part IV.
Lumpsum price worked out by Contractor for "EARTHWORK, SITE CLEARANCE AND DEMOLITION" as listed in Schedule Á' Part V.
Lumpsum price worked out by Contractor for "ROAD/ PATH/ CULVERT/HARDSTANDING" as listed in Schedule Á' Part VI.
Lumpsum price worked out by Contractor for "AREA DRAINAGE" as listed in Schedule Á' Part VII.
Lumpsum price worked out by Contractor for "SEWAGE DISPOSAL" as listed in Schedule Á' Part VIII.
Lumpsum price worked out by Contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule Á' Part IX.
Lumpsum price worked out by Contractor for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule Á' Part X.
Lumpsum price worked out by Contractor for "INTERNAL WATER SUPPLY" as listed in Schedule Á' Part XI.
Lumpsum price worked out by Contractor for "LIGHTNING PROTECTION" as listed in Schedule Á' Part XII.
Lumpsum price worked out by Contractor for "FIRE FIGHTING SYSTEM" as listed in Schedule Á' Part XIII.
Lumpsum price worked out by Contractor for "SOLAR PV PANEL" as listed in Schedule Á' Part XIV.
Lumpsum price worked out by Contractor for "AIR CURTAINS" as listed in Schedule Á' Part XV.
SCHEDULE Á' PART XVII Fittings / Fixtures and Misc Items FENCING AND GATE M & L for providing and fixing stainless steel (Grade 304) letters made of hollow tubes, channels, plates etc., thickness 1.5 mm to 1.6mm, all over height of each letter shall not be less than 150 mm including welding, grinding, buffing, polishing and making curvature (where ever required) and including engraving to granite / ACP / Metal sheets with suitable fixing arrangements like nut & bolt, screw, epoxy etc complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY AND AC S & F of vertical type VTPN including FP MCCB 125 Amps DB, 4 ways, Double door type complete all as specified and as directed
S & F of wall mounting fan of size 400mm sweep, 100 W power Air delivary complete all as specified and as directed
Supply and install inverter type hi wall split AC units indoor & outdoor complete with cordless remote control unit and with Alexa or Hey Google, with in built air ioniser and plasma filter for better indoor air quality with 5 star rating of capacity 2.0 TR, anti freeze thermostat, self diagnosis, 7 in 1 convertible with addtional AI mode, 4 way swing, anti microbial self clean tech, blue fin anti corrosive, condenser coiled and connected pipe are made of 100% copper, anti dust filter, with zero ozone depletion potential and low global warming potential with and including MS wall mounted bracket complete etc all as specified and directed
S & F of Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC and designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 5 KVA complete all as specified and as directed
EXTERNAL WATER SUPPLY S & F of Gun-metal, globe or gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked) of size 80 mm dia complete all as specified and as directed
M & L for extension of existing CI/DI pipe of any dia bore/size in position for insertion of 01 No of CI/DI TEE of required size and bore connecting pieces/flanged/socketed/spigoted of suitable bore and making run lead/flanged joint complete all as speciffied and directed.
M & L for earthing complete with Galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directly in the ground vertically to a depth not less than 3 metre below the ground level with top edge of the earth plate not less than 2.25 metre below the ground level connected to GI earth strip of 32mmx6mm size by means of bolts, nuts and washers protected by GI tubing light grade 40mm dia upto test point and GI watering pipe medium grade 20mm dia with funnel and wire mesh, PCC pit in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) chamber 40mm thick RCC cover slab (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) complete all as specified and shown in electrical plate No. 3 including earth work in any type of soil, removal of surplus soil and providing charcol dust and salt layers all around the earth plate upto 15cm and testing on completion complete all as specified and as directed by Engineer-in-Charge. (i) GI pipe of 40 mm dia upto 7.5 mtr length and GI strip of 32X6 mm shall deem to be included in the quoted rate.
EXTERNAL ELECTRIC SUPPLY M & L for removing and re-erection of 82 KVA DG Set with AMF panel from the working place and shifted to another place including transportion/shifting charges etc as required complete all as specified and directed.
LIGHTNING PROTECTION S & F Air termination, single pointed aluminium rod 12mm dia 300mm long extended with GI Pipe 25mm dia medium grade 1.5 mtr with insulator and PCC pit 1:2:4, B1 for fixing purpose of Air termination rod including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed
M & L for Earthing complete with Galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directly in the ground vertically to a depth not less than 3 metre below the ground level with top edge of the earth plate not less than 2.25 metre below the ground level connected to GI earth strip of 32mmx6mm size by means of bolts, nuts and washers protected by GI tubing light grade 40mm dia upto test point and GI watering pipe medium grade 20mm dia with funnel and wire mesh, PCC pit in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) chamber 40mm thick RCC cover slab (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) complete all as specified and shown in electrical plate No. 3 including earth work in any type of soil, removal of surplus soil and providing charcol dust and salt layers all around the earth plate upto 15cm and testing on completion complete all as specified and directed. (i) GI pipe of 40 mm diaupto 7.5 mtr length and GI strip of 32X6 mm shall deem to be included in the quoted rate.
FIRE FIGHTING SYSTEM S & F for fire hydrant stand post with provn of single outlet 100 mm dia confirming to IS 908 including all fittings and fixtures complete all as specified and directed.
S & F for fire hydrant landing valve type A (Single head outlet) of 63 mm dia confirming to IS 909 including tees, elbows etc all fittings, fixtures and support complete all as specified and directed.
S & F for 63 mm dia gun metal branch pipe with 12.5 mm nozzle conforming to IS 903 including all fittings and fixtures complete all as specified and directed.
S & F for hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle, MS sheet 2 mm thickness including all fittings and fixtures complete all as specified and directed.
S & F for hose reel of 20 mm dia and 30 meter length conforming to IS 5132 including tees, elbows etc all fittings, fixtures and support complete all as specified and directed.
S & F for branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 including tees, elbows etc all fittings, fixtures and support complete all as specified and directed.
S & F for 63 mm dia, 15 meter long hose reinforced rubber lined (RRL) type "A", ISI marked (IS-636) woven jacketed hose pipe fungus resistant tested to bursting pressure 32 kg/Sq cm complete with male and female coupling conforming to IS 903 including tees, elbows etc fittings and fixtures and support complete all as specified and directed.
S & F for pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm complete all as specified and directed.
S & F for gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built-in check valves and 100mm dia flanged outlet complete with all accessories complete all as specified and directed.
S & F for MS cabinet (approx 750mm x 600mm x 450mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete including tees, elbows etc all fittings and fixtures and support complete all as specified and directed.
S & F for automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete including tees, elbows etc all fittings and fixtures and support complete all as specified and directed.
M & L for Earthing complete with Galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directly in the ground vertically to a depth not less than 3 metre below the ground level with top edge of the earth plate not less than 2.25 metre below the ground level connected to GI earth strip of 32mmx6mm size by means of bolts, nuts and washers protected by GI tubing light grade 40mm dia upto test point and GI watering pipe medium grade 20mm dia with funnel and wire mesh, PCC pit in PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) chamber, 40mm thick RCC cover slab (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) complete all as specified and shown in electrical plate No. 3 including earth work in any type of soil removal of surplus soil and providing charcol dust and salt layers all around the earth plate upto 15cm and testing on completion complete all as specified and as directed (i) GI pipe of 40 mm dia upto 7.5 mtr length and GI strip of 32X6 mm shall deemed to be included in the quoted rate.
S & F for above and below false ceiling bulb type gun metal sprinkler head, pendent type set to operate at 57 degree C with response indicator complete all as specified and directed.
S & F for Strainer Y type conforming to IS, size 50 mm (2”) dia. including tees, elbows etc all fittings and fixtures and support complete all as specified and directed.
S & F for Strainer Y type conforming to IS, size 80 mm (3”) dia. including tees, elbows etc all fittings and fixtures and support complete all as specified and directed.
S & F for Foot Valve conforming to IS 4038, 150 mm (6”) dia. including all fittings and fixtures complete all as specified and directed.
S & F for Alarm Valve 100mm including all fittings and fixtures complete all as specified and directed.
S & F for Air Relief Valve 25mm including all fittings and fixtures complete all as specified and directed.
S & F hume Pipe 250mm dia including tee, elbow etc all fittings and fixtures and support as per site requirement and specified as directed by Engr-in-Charge and change the corresponding SSR unit rate and amount please.
S & F air pressure vessel 150mm dia including all fittings and fixtures complete all as specified and directed by Engr-in-Charge
S & F MS flanged pipe 150mm NB heavy duty (C Class) for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer including tees, elbows etc all fittings and fixtures and support as per site requirement and specified and directed
All as per item No. 1 but for 100mm NB heavy duty (C class) MS flanged pipe
Supply and Install Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings, suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V, 3 phase, 50 Hz AC supply, 70 m Head. 1620 LPM discharge, air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows, Mild Steel class 'C' diesel pump exhaust pipe 150mm dia with one layer of10mm thick asbestos rope insulation and including all fitting clamp/ structural steel supports complete and all accessories complete all as specified and directed.
SOLAR PV PANEL Supply, Install, Test, synchronise and Commissioning of Roof top solar power plant of capacity 10 KWP, On-grid type complete with following components :-
Supply, Install, Test, synchronise and Commissioning of Roof top solar power plant of capacity 10 KWP, On-grid type complete with following components :- (I) Solar PV Modules with corrosion resistant aluminum frame, inter connecting cables, diodes etc - Qty as required to generate 10 KWP. Note : Following information should be found mentioned on each module.a. Name of the manufacture of the PV module (b) Name of the manufacturer of Solar Cells. (c) Month & year of the manufacture (separate for solar cells and modules) (d) Country of origin (separately for solar cells and module) (e) I-V curve for the module Wattage, Im, Vm and FF for the module (f) Unique Serial No and Model No of the module (g) Date and year of obtaining IEC PV module qualification certificate. (h) Name of the test lab issuing IEC certificate. (II) Module Mounting structure (i) It shall be made of Hot dip galvanised MS or aluminium (ii) Suitable fastening arrangement, grouting and coping to be provided to secure modules against wind. (III) Array Junction Box (AJB) : (i) AJB's shall be made of GRP/FRP with dust, water & vermin proof arrangement with IP 65 protection with transperant covers. (ii) It shall have SPD and Reverse blocking diodes.
(IV) Solar on grid Inverter with MPPT charge controller : (i) It shall be enclosed in weatherproof enclosure with minimum IP 65 protection (ii) It shall have features like wake up, synchronisation, shut down etc (ii) It should have Anti-Islanding protection and also Internal protection arrangement against various electrical faults (iii) Nominal Output power 3 Phase, 415V, AC, 50 Hz (iv) THD shall be less than 3% (v) PF more than 0.9 (V) AC Distribution Box (ACDB) : It shall be made of GRP/FRP with dust, water & vermin proof arrangement with IP 65 protection with transperant covers. (ii) It shall have SPDs, control gears etc. (VI) Cabling, wiring and conduiting (i) Interconnections to be provided all as per OEM recommendations complete for AC and DC supply from Solar PV modules to Existing State Grid panel which is existed at site. (ii) All wires / cables must be terminated through cable lugs. (iii) The input & output termination can be made through suitable cable glands. (VII) Independent Lighning Protection System comprising Aluminium Air Termination Rod 12mm dia 300mm length Qty-04 No, Aluminium strip 20x3mm from Air Termination rod to Test Point - Upto 20RM, Test point-01 No, GI Earthing pit with Earth Resistance Value less than 5 Ohms - 01 No
Note : (i) The rate quoted shall inclusive of all the material and labour cost of PV Modules, Solar inverter, Main Junction box with brackets, Array junction box with brackets, installation kit for power pack, Hardware kit for structure, MC4 cable couplers, necessary earthing and Lightning arrester as per manufacturer specfication and necessary cable connection using suitable size multi stranded aluminium conductor cable for ACDB to LT Panel (ii) PCC foundation and necessary internal wiring for segregation of light circuits in the existing DB circuits and not paid separately under relevant items. Make of OEM :- TATA/Solar/BHEL/Vikram Solar equivalent (iii) Grid connect solar inverter (10Kw Three phase 50 Hz MPPTDC:AC=1.2 Max 01 Nos (iv) Solar PV Module 330 Wp multicystalline silicon with module mounting structure, module mouting clamps and rails Make TATA Power Solar or equivalent (v) Array juction box ( Input-6 Output with MOV &Fuses) - 01 No (vi) AC Distribution board with multifunctional meter and breakers - 01 (vii) 1 Core x 4 sqmm EB XLPE copper cable (Array inter connection) to inverter 960 meter (viii) 4 core x 10sqmm XLPE Aluminium cable (inverter to ACDB) - 70 Mtr (ix) 3.5 Core x 25 sqmm XLPE aluminium cable ACDB to LT Panel -70 Mtrs (x) Necessary safety earthing kits Earthing strip (25mm x 5mm) and lightning arrrester as per IS 3043 (xi) MC4 cable couplers (Male & Female pairs) (xii) Installation kit (communication cable, invertor canopy, Tool kit)
S & F for bracket suitable for street light, made out of 40 mm dia 1.5 mtr length GI pipe medium grade bend to shape fixed with 40 x 6mm MS flat iron clamp, bolts, nuts and washers incl painting MS clamp with one primer coat and two coat of aluminum paint complete all as specified and directed.
CCTV CAMERAS Supply, installation testing and commissioining of SECURUS SS-NC20L2XP-SXF-M5(S) 5.0 MP AI outdoor network bullet cemara with built-in audio with the following accessories:- (i) 32 Channel vedio/audio 5 amp recording NVR -01 No (ii) Ultra HD 4 AM IP bullet cemara -12 Nos (iii) 8 port POE switch - 02 Nos (iv) 6 TB Hard Disk - 02 Nos (v) Cat 6 cable with white conduit - 600 mtr (vi) 6U Rack (with tray) - 01 No (vii) 40" inch TV - 01 No (viii) Cemara stands and Angles - 01 No Note: Rate quoted under this item also includes installation of all camers and maintenance of complete network for one year.
Sri Lakshmi Constructions (BID ID -3174953)
RAVI ENTERPRISE (BID ID -3174880)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .