Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.6 LAccepted-AOC | 1 | Accepted-AOC The lowest tenderer | |
| 2 | 2₹35.3 L+₹4.6 L (15.1%)Rejected-Finance | 2 | Rejected-Finance Not the lowest tenderer | |
| 3 | 3₹35.3 L+₹4.7 L (15.2%)Rejected-Finance | 3 | Rejected-Finance Not the lowest tenderer | |
| 4 | 4₹39.0 L+₹8.4 L (27.4%)Rejected-Finance | 4 | Rejected-Finance Not the lowest tenderer | |
| 5 | 5₹42.9 L+₹12.3 L (40.1%)Rejected-Finance | 5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
14 Apr 2021, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINT OF LEAKAGE AND SEEPAGE NEAR CPH LEFT SIDE AT OLD NAVY NAGAR UNDER AGE BRI OF GE NW NAVY NAGAR COLABA MUMBAI
2021_MES_433053_1
8460/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D and category a(i)
7 documents required · 7 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹98,000
5 May 2021
25 Mar 2021
15 Apr 2021
25 Mar 2021
14 Apr 2021
8 Apr 2021
25 Mar 2021 - 14 Apr 2021
Amount
M&L for providing and applying micro concrete, blend of Portland cement, graded fillers and chemical aditives which impart controlled expansion and should be ready to use and can fill convoluted voids, compensates shrinkage at both plastic and Hardened states , if more than 40% of cross-section area of structure is under distress, then the area shall be repaired. Notes: (a) Minimum thickness to be used is 50mm with addition of 10mm down aggregates of 25% of the weight of mix ready to use powder with water- powder ratio of 0.18. Strength of 1 day to be 20N/mm2. Time of expansion to start after 20min of mixing and finish in 120 min of mixing. Epoxy bonding agent having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-25 Mpa at 7 days & bond strength (ASTM C 881)-11 N/mm2 at 7 days, having an over lay time of 3 hrs at 30°C. shall be mixed with cement as per manufacturer's instructions and covering capacity (b) The covering capacity of chemicals indicated is as per manufacturer's instructions. It may vary as per the substrate on plus side and contractor shall have no claim whatsoever on this account, complete all specified and directed by Engineer-in-charge. (Make- Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.)
M&L for providing and applying two coats of acrylic polymer based cementitious composite water proof coating system. It shall be non- flammable, non - combustible. It shall give tough and hard waterproofing surface. It shall allow entrapped vapour to escape preventing peeling and blistering. It shall have excellent bond to building materials. It shall be highly durable in continuous wet condition. Coating to be applied after proper surface preparation to remove loose dust, cleaning, mixing using slow speed electric drill and application of two coats of two components ie. liquid and powder in proportion as per manufacturer instructions, thickness of each coat not less than 1mm (1.50-2.00kg/Sqm), and applying curing of the surface using low viscosity emulsion which incorporate a special alkali reactive emulsion breaking system on the protection screed. It shoud be non-penetrating continuous film complies with the internationally recognized ASTM C309-90 standards.Product should have daylight Reflectance of 70% as per ASTM E-1347 , complete all specified and directed by Engineer-in-charge. Make :Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for providing and applying two coats of water based Aliphatic acrylate -Anti-Carbonation coating for concrete surfaces over a coat of acrylic polymer primer. The coating to be applied on surface shall be liquid applied highly durable waterproof coating system for surface , based on high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides. It shall have properties that provide features like crack bridging ability, breathability, flexibility & exterior durability and resists micro-organism growth.It shall cover hairline cracks up to 0.5 mm effectively. It shall have excellent crack bridging ability and shall bridge cracks up to 2 mm width. The elongation at break is approx. 220 %. The tensile strength is 0.7 Mpa. It has a hardness shore ‘A’ scale of 80, with an adhesion strength of 3.4 Mpa. The coating is UV resistant, algae and fungus resistant, and has a water vapor permeability of 40 gm/m²/day and a crack bridging ability of 1-2 mm. The coating must be applied with temperature above 5°C and below 45°C. The coating shall be applied in two coats of by roller or brush application at the interval of 4-6 hours.Allow applied coating to dry or cure for 7 days. Before applying coating one coat of Water based Acrylic polymer primer cum sealer coating for concrete surfaces primer cum sealer must be applied, complete all specified and directed by Engineer-in-charge. (Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.)
M&L for applying two coats of solvent free, epoxy resin based material of two componets applied @0.10lit/Sqm/Coat on the cured surface. The concrete substrate must be sound and of sufficient compressive strength (minimum 20 N/mm2) with a minimum pull off strength of 1.5 N/mm2. The substrate must be clean, dry and free of all contaminants such as dirt, oil, grease etc.Moisture content of substrate surface should not be more than 5% complete all specified and directed by Engineer-in-charge. (Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.)
M&L for applying one coat of two component amine cured solvent free apoxy resin based epoxy mastic coating (application 2.00 to 2.50 Sqm/lit) using Light brush blasting using nonmetallic abrasive leaving a clean, rough and even pattern.it should be based on a 100% epoxy formulation and contains no solvents or water diluents. Apply two coats with brush or squeeze to the existing surface, working well into the substrate.it should achieve Compressive Strength of >70 MPa after 14days, having pot life, minutes at 27⁰C, 100 g >40 mass, complete all specified and directed by Engineer-in-charge. (Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.)
M&L for applying amine cured epoxy coating cum primer of film thickness of approx. 1 to 2mm should be built up in two coats, should achieve Adhesion bond strength 1 N/mm2, pot life of 30 minutes@30 C. Before applying primer Concrete / steel surface should be cleaned by any suitable method (like sand blasting, water jetting etc.) to remove old coatings, grease, oil, curing compounds, loose particles, weld spatter, flux, rust etc, complete all specified and directed by Engineer-in-charge. Make :Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for protecting and plastering of waterproofed surface Using cement based, micro- silica restoration mortar.The product needing only addition of water at site which can be applied by trowel.cement, sand can be used for finishing purpose. It is reinforced with specially designed bean shaped, alkali resistant synthetic fibers for exceptional resistance to cracking. It is recommended for repair situations requiring application of mortar up to 10 mm thickness in one layer.The product shall achieve a compressive strength of 11 MPa in 1 day & 30 MPa in 28 days and a minimum flexural strength of 6 MPa @ 7 days. It shall have a tensile strength of minimum 2 MPa. It shall have a minimum bond strength of 2 MPa, complete all specified and directed by Engineer-in-charge. Make: Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
M&L for providing and applying the treated surface with high quality repair mortar with polymer and fibre content (mixed with cement, special additives and sand).water cement ratio of which shall be 0.16, 28 days compressive strength shall be 30 MPa,mixed density shall be 2.18 kg/ltr, flexural strength shall be 6 MPa for 7 days and tensile strength for 7 days shall be more than 2MPa.Its adhesion bond strength shall be greater than 2 MPa with creep strain reduction of 8%. The modulus of elasticity of this product shall be 23-26 KN/mm². It shall not bleed / segregate on adding water and shall provide dual shrinkage compensation i.e – both plastic & hardened. It shall be capable of being applied in thicknesses of 20 mm without sagging or falling and shall have minimum adhesive bond strength of 2 MPa.All cementitious systems have to be cured for a minimum period of 15 days by water curing. Note : The mortar should be sprayed using gunitting machine.the nozzle of the spray should be held approximately 450mm from the concrete surface and should be passed back and forth to ensure complete and even coverage. The pump pressure should be maintained at a level to produce a fine spray ensuring complete coverage of the surface,complete all specified and directed by Engineer-in-charge. (Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.)
M & L for providing and applying a layer of high solids resin based pigmented concrete compound (application 4.00 to 5.00Sqm/lit). It forms a continuous membrane that controls hydration for strong and durable concrete .It should have specific gravity of 1.02. It can be applied by brush or can be sprayed, If sprayed the nozzle of the spray should be held approximately 450mm from the concrete surface and should be passed back and forth to ensure complete and even coverage. The pump pressure should be maintained at a level to produce a fine spray ensuring complete coverage of the surface, complete all specified and directed by Engineer-in-charge. (Make : Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.)
M&L for providing and crack sealing cementitious material in powder form. It is easy to apply and can be finished or smoothened off with a putty blade or a damp sponge. It sets quickly on application and can be over coated with common paints / coatings, white coloured with setting time of 15min and Compressive strength as per ASTM C 109 of 22N in 7 days. Mixing Ratio to 1: 2.5 (Water: Powder) Cutting groove of less than 6mm X 6mm. complete all as specified and directed by Engr-in-Charge. Make :Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.
Material and labour for removing the cavities, roughening the smooth surfaces, scrapping out / removing corrosion all loose/scale/rust etc from the visible reinforcement by applying rust remover @ 200ml per sqm and cleaning the steel reinforcement properly, and then applying single component cementitious corrosion inhibiting primer as per manufacturers instructions of exposed and new steel reinforcement complete all as specified and directed by Engineer-in-Charge. (Make :Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.)
M&L machinary for removal of water and cleaning of existing water tank from inside surfaces of the tank by scraping down walls & bottom surafce using steel wire brushes to remove all disputation/fungus,other micro-organisms etc. Using light hammer & wire brushes, taking out and removing sediment loose dirt/mud sludge,vegetation and other foreign materials completely from the internal and external surface of tank disposal of all the waste/spoil out side of the MD land, washing repeatedly the inside surfaces of tank with water and washing with clean water thoroughly and preparation of the surface to review new plaster complete all specified and directed by Engineer-in-charge.
M&L for drilling hole chemical anchoring of reinforcement on existing columns/chajja/beams with Hilti HIT-HY 70 minimum hole depth 100mm, steel bar 12mm dia and drill bit dia 14mm, complete all as specified and directed by Engineer-in-Charge. Note : This item shall be undertaken by the authorised rep of Hilti india Pvt Ltd/Carlisle Syntec Middle Cast/ SNI Infra Tech Pvt Ltd/Thermax Ltd/Kryton Build Mat Co Pvt Ltd.
M&L for MS TMT bars 6mm to 8mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge
Steel form work to sides and soffits of lintels, beams, columns, shelves, chajjas including overhangs etc for fair finished flat surface, complete all as specified and directed by Engr-in-charge
M&L for repair to damaged existing surfaces of upto 15 m height from plinth level by structural strengthening using epoxy injection grouting as under :- (a) High strength epoxy resin based Injection, Automatic NRV packers in all column and beams from all access side Distance of injections will be 500 m c/c in matrix pattern until column is submerged in dampness of chemical. (b) Injection grouting using two component grouting polymer having low viscosity, high molecular weight, thermosetting to reach very deep pores, voids, cracks and honeycomb in the concrete, specific gravity of which shall be 0.95, pH of 2-4,viscosity of 20-25 Sqm/sec by B/4 ford cup and having curing time of 30-90 minutes area by suitable gun/pump at required pressure (100 bar to 150 Bar, including cutting of nipples after curing etc and sealing the nozzles with Epoxy Filler and preparing the surface to match with the existing surfaces all as directe, complete all specified and directed by Engineer-in-charge. (Make :- Carlisle Syntec Middle Cast, SNI Infra Tech Pvt Ltd,Thermax Ltd, Kryton Build Mat Co Pvt Ltd.)
M&L for providing and fixing welded MS wire mesh weighing not less than 1 kg/sqm on the prepared surface which should be cleaned and should be removed from dirt, fungus and all foreign material
Note: (a) The work for item Ser No 1.00 to 17.00 to shall be executed directly by company or their authorized applicator. Application shall be authorized in writing by company and guarantee/responsibility of work executed shall be owned by company in writing. (b) Quoted rate shall be inclusive of material all labors tools and plants scaffolding and working upto 15 mtr height. (c) Adoption of necessary safety arrangement like safety belts. ropes. helmets, netting etc. which are required for safety of working at height etc. which are required for safety of working at height exceeding 3 to 25 mtr height shall be mandatary and deemed to be inclusive on quoted rates.
LOKESH AND CO.
Diamond Construction
M/s Raghav Traders
M/s R.D. Company
M/S DURGA ASSOCIATES
M/S MUKESH AGARWAL
S Balwinder Singh
M/s Manish Contractor
M/s Ratan Lal Jain and Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .