Loading…
Loading…
| Sl No | Description | Qty | Unit | Subash L1 | R SUJATHA L2 |
|---|---|---|---|---|---|
| 1.00Part 1: Supply & Laying of House Service Connection and pipeline in Vinayagapuram - Kovilambakkam Panchayat Estimate amount; 9.35 Lakhs | |||||
| 2.00 | HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm | 247 | Each | - | - |
| 3.00 | Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm) | 247 | Each | - | - |
| 4.00 | Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm) | 247 | Each | - | - |
| 5.00 | Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 247 | Each | - | - |
| 6.00 | Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 247 | Each | - | - |
| 7.00 | Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm | 247 | Each | - | - |
| 8.00 | MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-39x8 | 1,976 | Each | - | - |
| 9.00 | Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-39x8 | 1,976 | Each | - | - |
| 10.00 | Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -39x8 | 1,976 | Each | - | - |
Tender Value
₹1.8 Cr
EMD Value
₹1.8 L
Closing Date
14 Sept 2020, 3:00 pmClosed
PROJECT DIRECTOR
DRDA CHENGALPET
Implementation of Jal Jeevan Mission to Provide Functional Household Tap Connection to Rural Household in Kovilambakkam Panchayat in St.Thomas Mount Panchayat Union in Chengalpattu District for the Year 2020 - 2021
2020_RDTN_178557_1
506/2020/A3/DATE 5.09.2020
Open Tender
Civil Works - Water Works
Lump-sum
120 days
KOVILAMBAKKAM
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹1.8 L
Yes
DRDA CHENGALPET
15 Sept 2020
8 Sept 2020
14 Sept 2020
8 Sept 2020
14 Sept 2020
9 Sept 2020
9 Sept 2020
Amount
Part 1: Supply & Laying of House Service Connection and pipeline in Vinayagapuram - Kovilambakkam Panchayat Estimate amount; 9.35 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-39x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-39x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -39x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
Part 2: Supply & Laying of House Service Connection and pipeline in Max work nagar - Kovilambakkam Panchayat Est.Amt-8.55 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-40x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-40x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber 40x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
Part 3: Supply & Laying of House Service Connection 60000lit OHT(1no),Pipeline and Borewell(2nos) in Engineering avenur - Kovilambakkam Panchayat . Under JJM Scheme.Est.Amt:33.60 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-66x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-66x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -66x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
60000lit OHT-Earthwork excavation and depositing on bank with an initial lead of 10m and lift of 2m in the following classification of soils as directed by department officers. Hard stiff clay, block cotton, hard red earth shales, murram, ordinary gravel, stoney eart
First depth of 2m
Second depth of 1m
Sand filling for foundation with clear river sand including cost of sand watering, ramming and consolidation etc complete as directed by TWAD Board officers.
Cement concrete 1:4:8 (one cement four sand and eight aggregates) using 40mm HBGS for levelling course for foundation including the cost of mixing concrete, ramming, curing etc., complete as directed by TWAD Board officers.
RCC 1:1.5:3 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
For items 1.5m to 4.5m below GL
For items 0 to 1.50m below GL
For items 0m to 1.5m above GL
For items 4.51m to 7.32m above GL
For items 7.32m to 10.98m above GL
For items 10.98m to 14.64m above GL
For items above 14.64m & up to 18.30m from GL
Supplying and erecting steel centering for sides and soffits I including necessary supports' and shuttering to the required height for RCC items using MS sheets of suitable size of BG.10 stiffened with welded MS angles of size 25mm x 25mm x3mm of boarding
PLANE SURFACES Below GL
ABOVE G.L. to 3.30m
FROM FLOOR 3.30 TO 4.30 M
Curved Surface
0 to 3.30m from floor level
3.30 to 4.30m from floor level
Square column
Below G.L.
Ground level to 3.30 m
Painting two coats with approved Exterior Emulsion paint over one coat of priming coat over cement plastered exposed surface of the Reservoir including cleaning, preparing the surface and curing etc., complete
Supplying, fabricating and placing in position of HSD steel rods for Reinforcement including the cost of steel and binding wire etc., complete and as directed by TWAD Board officers.
Supply delivery and fixing of staircase with M30 grade concrete for landings, MS ladder of 0.45m wide using 50x50x5mm MS angles for sides and steps at 0.30m c/c, with GI pipe handrails using 32mm GI pipes for railings and verical support at 0.45m C/c, MS flats (Size 40mm x 5mm ) for horizontal ties at 0.3m c/c and at bottom with Anchor fastener bolts of size 12mm x 75mm including cost of materials labour for fabrication of handrails fixing, painting etc., complete.
Providing and fixing of RCC inner access ladder in RCC 1:1.5:3 (one cement, one and half sane! and three aggregates) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete cu
Providing PVC ventilating arrangements mosquito proof nylon net with 110 mm PVC pipes and cowl and as directed by TWAD Board officers
Providing cut stone slab in CM 1:3 and as directed by RD officers
Providing manhole cover of size 1x1 0.60 X 0.60M in RCC 1: 1.5:3 with suitable reinforcement and 5O x 5O x 6mm MS angle fixed along edges and as directed by RD officers.
65mm Ø GI pipes for inlet connection
65mm Ø GI pipes for over flow pipe
65mm Ø GI pipes for scour pipe
65mm Ø GI pipe for delivery pipe
Refilling the foundation with excavated earth including consolidation as directed by the TWAD Board officers.
Labour charges for GI pipe connection to the OHT, for inlet, outlet, overflow and scour arrangements including cutting and threading, earth work excavation & refilling.
Borewell;Provision for Geological Survey Scketch.
Drilling of 150 mm dia borewell hard rock area to any depth including labour charges for inserting casing pipe assembly in the drilled hole including transporting charges for the rig and supporting vehicles from one place to another place
Supply and delivery of 150 mm dia pvc casing pipes as followsa.150mm OD PVC plain casing pipe(CS)
Supply and Following of 5Hp Submersible Motor 75lpmx75m Including Cost and Conveyance etc Complete.
Supply and Following of 5Hp Submersible Motor Control Panel Board Including Cost and Conveyance etc Complete.
Supply & Delivery of Block Hose Including all charges etc Complete
Supply and fixing of the following materials:
a) G.M Non return valve 50mm
b) G.M Gate Valve 50mm
Supply & Laying of 3core 4.00 sq.mm submersible cable
Erection charges to new submersible pump etc fixing of panel board.
Earth work excavation in all types of soil lead And lift ss 20 B etc complete Including All Labour Charges Including Cost and Conveyance etc Complete.
Supply and Following of 90mm dia PVC Pipe Including Cost and Conveyance etc Complete. 6KSC
Supply and Fixing of PVC Pipe Including Cost and Conveyance etc Complete.
Refilling excavated earth Including All Labour Charges Including Cost and Conveyance etc Complete.
Part 4:Supply & Laying of House Service Connection and Pipeline in Katithapuram - Kovilambakkam Panchayat . Est.Amount: 13.45 lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-692x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-692x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -692x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
Part 5: Supply & Laying of House Service Connection 60000lit OHT(1no),Pipeline and Borewell(1no) in Kureunji nagar - Kovilambakkam Panchayat . Under JJM Scheme. Est.Amt: Rs 23.00 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-538x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)538x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber 538x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
60000lit OHT-Earthwork excavation and depositing on bank with an initial lead of 10m and lift of 2m in the following classification of soils as directed by department officers. Hard stiff clay, block cotton, hard red earth shales, murram, ordinary gravel, stoney eart
First depth of 2m
Second depth of 1m
Sand filling for foundation with clear river sand including cost of sand watering, ramming and consolidation etc complete as directed by TWAD Board officers.
Cement concrete 1:4:8 (one cement four sand and eight aggregates) using 40mm HBGS for levelling course for foundation including the cost of mixing concrete, ramming, curing etc., complete as directed by TWAD Board officers.
RCC 1:1.5:3 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
For items 1.5m to 4.5m below GL
For items 0 to 1.50m below GL
For items 0m to 1.5m above GL
For items 4.51m to 7.32m above GL
For items 7.32m to 10.98m above GL
For items 10.98m to 14.64m above GL
For items above 14.64m & up to 18.30m from GL
Supplying and erecting steel centering for sides and soffits I including necessary supports' and shuttering to the required height for RCC items using MS sheets of suitable size of BG.10 stiffened with welded MS angles of size 25mm x 25mm x3mm of boarding
PLANE SURFACES Below GL
ABOVE G.L. to 3.30m
FROM FLOOR 3.30 TO 4.30 M
Curved Surface
0 to 3.30m from floor level
3.30 to 4.30m from floor level
Square column
Below G.L.
Ground level to 3.30 m
Painting two coats with approved Exterior Emulsion paint over one coat of priming coat over cement plastered exposed surface of the Reservoir including cleaning, preparing the surface and curing etc., complete
Supplying, fabricating and placing in position of HSD steel rods for Reinforcement including the cost of steel and binding wire etc., complete and as directed by TWAD Board officers.
Supply delivery and fixing of staircase with M30 grade concrete for landings, MS ladder of 0.45m wide using 50x50x5mm MS angles for sides and steps at 0.30m c/c, with GI pipe handrails using 32mm GI pipes for railings and verical support at 0.45m C/c, MS flats (Size 40mm x 5mm ) for horizontal ties at 0.3m c/c and at bottom with Anchor fastener bolts of size 12mm x 75mm including cost of materials labour for fabrication of handrails fixing, painting etc., complete.
Providing and fixing of RCC inner access ladder in RCC 1:1.5:3 (one cement, one and half sane! and three aggregates) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete cu
Providing PVC ventilating arrangements mosquito proof nylon net with 110 mm PVC pipes and cowl and as directed by TWAD Board officers
Providing cut stone slab in CM 1:3 and as directed by RD officers
Providing manhole cover of size 1x1 0.60 X 0.60M in RCC 1: 1.5:3 with suitable reinforcement and 5O x 5O x 6mm MS angle fixed along edges and as directed by RD officers.
65mm Ø GI pipes for inlet connection
65mm Ø GI pipes for over flow pipe
65mm Ø GI pipes for scour pipe
65mm Ø GI pipe for delivery pipe
Refilling the foundation with excavated earth including consolidation as directed by the TWAD Board officers.
Labour charges for GI pipe connection to the OHT, for inlet, outlet, overflow and scour arrangements including cutting and threading, earth work excavation & refilling.
Borewell;Provision for Geological Survey Scketch.
Drilling of 150 mm dia borewell hard rock area to any depth including labour charges for inserting casing pipe assembly in the drilled hole including transporting charges for the rig and supporting vehicles from one place to another place
Supply and delivery of 150 mm dia pvc casing pipes as followsa.150mm OD PVC plain casing pipe(CS)
Supply and Following of 5Hp Submersible Motor 75lpmx75m Including Cost and Conveyance etc Complete.
Supply and Following of 5Hp Submersible Motor Control Panel Board Including Cost and Conveyance etc Complete.
Supply & Delivery of Block Hose Including all charges etc Complete
Supply and fixing of the following materials:
a) G.M Non return valve 50mm
b) G.M Gate Valve 50mm
Supply & Laying of 3core 4.00 sq.mm submersible cable
Erection charges to new submersible pump etc fixing of panel board.
Earth work excavation in all types of soil lead And lift ss 20 B etc complete Including All Labour Charges Including Cost and Conveyance etc Complete.
Supply and Following of 90mm dia PVC Pipe Including Cost and Conveyance etc Complete. 6KSC
Supply and Fixing of PVC Pipe Including Cost and Conveyance etc Complete.
Refilling excavated earth Including All Labour Charges Including Cost and Conveyance etc Complete.
Part 6: Supply & Laying of House Service Connection andPipeline in Suseela nagar - Kovilambakkam Panchayat .Under JJM Scheme. Est.Amt: 7.50 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-429x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-429x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -429x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
Part 7: Supply & Laying of House Service Connection and Pipeline in PMD nagar - Kovilambakkam Panchayat . Under JJM Scheme.Est.Amt:3.02 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-166x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) -166x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -166x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline:Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
Part 8: Supply & Laying of House Service Connection and pipeline in Muthaiya nagar - Kovilambakkam Panchayat Estimate amount; Rs 3.00 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-166x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm) -166x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -166x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline:Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
Part 9: Supply & Laying of House Service ,Borewell(2nos),Pipeline in Rose nagar - Kovilambakkam Panchayat . Under JJM scheme. Est.Amount: 18.12 lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-692x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-692x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -692x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
Borewell;Provision for Geological Survey Scketch.
Drilling of 150 mm dia borewell hard rock area to any depth including labour charges for inserting casing pipe assembly in the drilled hole including transporting charges for the rig and supporting vehicles from one place to another place
Supply and delivery of 150 mm dia pvc casing pipes as followsa.150mm OD PVC plain casing pipe(CS)
Supply and Following of 5Hp Submersible Motor 75lpmx75m Including Cost and Conveyance etc Complete.
Supply and Following of 5Hp Submersible Motor Control Panel Board Including Cost and Conveyance etc Complete.
Supply & Delivery of Block Hose Including all charges etc Complete
Supply and fixing of the following materials:
a) G.M Non return valve 50mm
b) G.M Gate Valve 50mm
Supply & Laying of 3core 4.00 sq.mm submersible cable
Erection charges to new submersible pump etc fixing of panel board.
Earth work excavation in all types of soil lead And lift ss 20 B etc complete Including All Labour Charges Including Cost and Conveyance etc Complete.
Supply and Following of 90mm dia PVC Pipe Including Cost and Conveyance etc Complete. 6KSC
Supply and Fixing of PVC Pipe Including Cost and Conveyance etc Complete.
Refilling excavated earth Including All Labour Charges Including Cost and Conveyance etc Complete.
Part 10: Supply & Laying of House Service Connection 60000lit OHT(1no),Bore well(2nos),Pipeline in Rajam nagar - Kovilambakkam Panchayat Under JJM Scheme.Est.Amt: 24.00 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-538x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)538x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber 538x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
60000lit OHT-Earthwork excavation and depositing on bank with an initial lead of 10m and lift of 2m in the following classification of soils as directed by department officers. Hard stiff clay, block cotton, hard red earth shales, murram, ordinary gravel, stoney eart
First depth of 2m
Second depth of 1m
Sand filling for foundation with clear river sand including cost of sand watering, ramming and consolidation etc complete as directed by TWAD Board officers.
Cement concrete 1:4:8 (one cement four sand and eight aggregates) using 40mm HBGS for levelling course for foundation including the cost of mixing concrete, ramming, curing etc., complete as directed by TWAD Board officers.
RCC 1:1.5:3 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
For items 1.5m to 4.5m below GL
For items 0 to 1.50m below GL
For items 0m to 1.5m above GL
For items 4.51m to 7.32m above GL
For items 7.32m to 10.98m above GL
For items 10.98m to 14.64m above GL
For items above 14.64m & up to 18.30m from GL
Supplying and erecting steel centering for sides and soffits I including necessary supports' and shuttering to the required height for RCC items using MS sheets of suitable size of BG.10 stiffened with welded MS angles of size 25mm x 25mm x3mm of boarding
PLANE SURFACES Below GL
ABOVE G.L. to 3.30m
FROM FLOOR 3.30 TO 4.30 M
Curved Surface
0 to 3.30m from floor level
3.30 to 4.30m from floor level
Square column
Below G.L.
Ground level to 3.30 m
Painting two coats with approved Exterior Emulsion paint over one coat of priming coat over cement plastered exposed surface of the Reservoir including cleaning, preparing the surface and curing etc., complete
Supplying, fabricating and placing in position of HSD steel rods for Reinforcement including the cost of steel and binding wire etc., complete and as directed by TWAD Board officers.
Supply delivery and fixing of staircase with M30 grade concrete for landings, MS ladder of 0.45m wide using 50x50x5mm MS angles for sides and steps at 0.30m c/c, with GI pipe handrails using 32mm GI pipes for railings and verical support at 0.45m C/c, MS flats (Size 40mm x 5mm ) for horizontal ties at 0.3m c/c and at bottom with Anchor fastener bolts of size 12mm x 75mm including cost of materials labour for fabrication of handrails fixing, painting etc., complete.
Providing and fixing of RCC inner access ladder in RCC 1:1.5:3 (one cement, one and half sane! and three aggregates) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete cu
Providing PVC ventilating arrangements mosquito proof nylon net with 110 mm PVC pipes and cowl and as directed by TWAD Board officers
Providing cut stone slab in CM 1:3 and as directed by RD officers
Providing manhole cover of size 1x1 0.60 X 0.60M in RCC 1: 1.5:3 with suitable reinforcement and 5O x 5O x 6mm MS angle fixed along edges and as directed by RD officers.
65mm Ø GI pipes for inlet connection
65mm Ø GI pipes for over flow pipe
65mm Ø GI pipes for scour pipe
65mm Ø GI pipe for delivery pipe
Refilling the foundation with excavated earth including consolidation as directed by the TWAD Board officers.
Labour charges for GI pipe connection to the OHT, for inlet, outlet, overflow and scour arrangements including cutting and threading, earth work excavation & refilling.
Borewell;Provision for Geological Survey Scketch.
Drilling of 150 mm dia borewell hard rock area to any depth including labour charges for inserting casing pipe assembly in the drilled hole including transporting charges for the rig and supporting vehicles from one place to another place
Supply and delivery of 150 mm dia pvc casing pipes as followsa.150mm OD PVC plain casing pipe(CS)
Supply and Following of 5Hp Submersible Motor 75lpmx75m Including Cost and Conveyance etc Complete.
Supply and Following of 5Hp Submersible Motor Control Panel Board Including Cost and Conveyance etc Complete.
Supply & Delivery of Block Hose Including all charges etc Complete
Supply and fixing of the following materials:
a) G.M Non return valve 50mm
b) G.M Gate Valve 50mm
Supply & Laying of 3core 4.00 sq.mm submersible cable
Erection charges to new submersible pump etc fixing of panel board.
Earth work excavation in all types of soil lead And lift ss 20 B etc complete Including All Labour Charges Including Cost and Conveyance etc Complete.
Supply and Following of 90mm dia PVC Pipe Including Cost and Conveyance etc Complete. 6KSC
Supply and Fixing of PVC Pipe Including Cost and Conveyance etc Complete.
Refilling excavated earth Including All Labour Charges Including Cost and Conveyance etc Complete.
Part 11: Supply & Laying of House Service Connection and Pipe line in Karumariamman nagar - Kovilambakkam Panchayat .Under JJM Scheme. Est.Amt: 7.20 Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-429x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-429x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -429x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
Part 12: Supply & Laying of House Service Connection,60000lit OHT(1no),Bore well(2nos),Pipeline in Ponniamman nagar - Kovilambakkam Panchayat . Under JJM Scheme.Est.Amt:30.85Lakhs
HSC Connection in DI Mains for Water Supply Scheme - Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around - 20mm
Common Items for HSC Connection - Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS:1554 BSPT, ISO:7-1 to suit the corresponding bore sizes of 15mm, 20mm and 25mm dia size ( 1/2", 3/4" and 1") in the saddle Connection as per IS :1554 BSPT, ISO:7-1 (20mm)
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (20mm)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Female Threaded Elbow with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes - 20mm
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK - 20mm-66x8
Earthwork Excavation for 20mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)-66x8
Labour Charges for Laying & Jointing 20 mm pipe in Excavated Trench in Proper Camber -66x8
Supply & Laying & Jointing 20 mm PVC Elbow (Mould) BIS 7834/1975 Part V for Tap Connection
Supply & Jointing 20 mm PVC Tap (Local rate)
U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID - 20mm
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.
Pipeline-Earthwork Excavation for 90mm PVC pipe laying work including cost of Refilling work as per Standard Specifications 20B (in Rm)
Supply & Delivery of 90mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Delivery of 63mm OD PVC Pipe as per IS 4985/2000 4.00 kg per Sqcm including cost & Conveyance of all materials & all Labour charges etc complete
Labour Charges for Laying & Jointing 90 mm & 63mm pipe in Excavated Trench in Proper Camber
Supply & Fixing of 80mm Dia GM Gate valve including cost & Conveyance of all materials & all Labour charges etc complete
Supply & Fixing of 80mm Dia GM Tee including cost & Conveyance of all materials & all Labour charges etc complete
60000lit OHT-Earthwork excavation and depositing on bank with an initial lead of 10m and lift of 2m in the following classification of soils as directed by department officers. Hard stiff clay, block cotton, hard red earth shales, murram, ordinary gravel, stoney eart
First depth of 2m
Second depth of 1m
Sand filling for foundation with clear river sand including cost of sand watering, ramming and consolidation etc complete as directed by TWAD Board officers.
Cement concrete 1:4:8 (one cement four sand and eight aggregates) using 40mm HBGS for levelling course for foundation including the cost of mixing concrete, ramming, curing etc., complete as directed by TWAD Board officers.
RCC 1:1.5:3 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
For items 1.5m to 4.5m below GL
For items 0 to 1.50m below GL
For items 0m to 1.5m above GL
For items 4.51m to 7.32m above GL
For items 7.32m to 10.98m above GL
For items 10.98m to 14.64m above GL
For items above 14.64m & up to 18.30m from GL
Supplying and erecting steel centering for sides and soffits I including necessary supports' and shuttering to the required height for RCC items using MS sheets of suitable size of BG.10 stiffened with welded MS angles of size 25mm x 25mm x3mm of boarding
PLANE SURFACES Below GL
ABOVE G.L. to 3.30m
FROM FLOOR 3.30 TO 4.30 M
Curved Surface
0 to 3.30m from floor level
3.30 to 4.30m from floor level
Square column
Below G.L.
Ground level to 3.30 m
Painting two coats with approved Exterior Emulsion paint over one coat of priming coat over cement plastered exposed surface of the Reservoir including cleaning, preparing the surface and curing etc., complete
Supplying, fabricating and placing in position of HSD steel rods for Reinforcement including the cost of steel and binding wire etc., complete and as directed by TWAD Board officers.
Supply delivery and fixing of staircase with M30 grade concrete for landings, MS ladder of 0.45m wide using 50x50x5mm MS angles for sides and steps at 0.30m c/c, with GI pipe handrails using 32mm GI pipes for railings and verical support at 0.45m C/c, MS flats (Size 40mm x 5mm ) for horizontal ties at 0.3m c/c and at bottom with Anchor fastener bolts of size 12mm x 75mm including cost of materials labour for fabrication of handrails fixing, painting etc., complete.
Providing and fixing of RCC inner access ladder in RCC 1:1.5:3 (one cement, one and half sane! and three aggregates) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete cu
Providing PVC ventilating arrangements mosquito proof nylon net with 110 mm PVC pipes and cowl and as directed by TWAD Board officers
Providing cut stone slab in CM 1:3 and as directed by RD officers
Providing manhole cover of size 1x1 0.60 X 0.60M in RCC 1: 1.5:3 with suitable reinforcement and 5O x 5O x 6mm MS angle fixed along edges and as directed by RD officers.
65mm Ø GI pipes for inlet connection
65mm Ø GI pipes for over flow pipe
65mm Ø GI pipes for scour pipe
65mm Ø GI pipe for delivery pipe
Refilling the foundation with excavated earth including consolidation as directed by the TWAD Board officers.
Labour charges for GI pipe connection to the OHT, for inlet, outlet, overflow and scour arrangements including cutting and threading, earth work excavation & refilling.
Borewell;Provision for Geological Survey Scketch.
Drilling of 150 mm dia borewell hard rock area to any depth including labour charges for inserting casing pipe assembly in the drilled hole including transporting charges for the rig and supporting vehicles from one place to another place
Supply and delivery of 150 mm dia pvc casing pipes as followsa.150mm OD PVC plain casing pipe(CS)
Supply and Following of 5Hp Submersible Motor 75lpmx75m Including Cost and Conveyance etc Complete.
Supply and Following of 5Hp Submersible Motor Control Panel Board Including Cost and Conveyance etc Complete.
Supply & Delivery of Block Hose Including all charges etc Complete
Supply and fixing of the following materials:
a) G.M Non return valve 50mm
b) G.M Gate Valve 50mm
Supply & Laying of 3core 4.00 sq.mm submersible cable
Erection charges to new submersible pump etc fixing of panel board.
Earth work excavation in all types of soil lead And lift ss 20 B etc complete Including All Labour Charges Including Cost and Conveyance etc Complete.
Supply and Following of 90mm dia PVC Pipe Including Cost and Conveyance etc Complete. 6KSC
Supply and Fixing of PVC Pipe Including Cost and Conveyance etc Complete.
Refilling excavated earth Including All Labour Charges Including Cost and Conveyance etc Complete.
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}12%
R SUJATHA
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_214061.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .